Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Comparison of copper and aluminum as the thermal link material for conduction-cooled accelerator cavities

Cryocooler conduction-cooling has recently emerged as a new frontier for cryogenic cooling for superconducting radiofrequency (SRF) cavities. In this scheme, an SRF cavity is mechanically coupled to a closed-cycle cryocooler using linkages made of high thermal conductivity metals. In this note, we compare the thermal transport properties of high purity aluminum and high purity copper as applied to SRF cavity conduction cooling. We show that copper can enable faster cooldown than aluminum from room temperature to the base temperature near 4 K and behave equally well or better during steady state cavity operation near the base temperature.

36 MATERIALS SCIENCE↗

Simulating Superconducting Devices in Novel Materials Using the G4CMP Simulation Toolkit

Understanding the kinematics of phonons and charge propagation in superconducting devices is crucial for conducting low-threshold dark matter searches and minimizing correlated errors in superconducting qubits. For nearly a decade, the Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, has been limited to simulating charge and phonon transport in silicon and germanium materials. In this work, we have expanded the capabilities of G4CMP to include novel substrate materials such as sapphire (Al2O3), Gallium Arsenide (GaAs), Lithium Fluoride (LiF), Calcium Tungstate (CaWO4), and Calcium Fluoride (CaF2). We demonstrate the use of this toolkit in generating phonon transport properties for these materials and compare the results with experimentally determined values where available. Additionally, we explore the performance of superconducting devices utilizing these materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗

Spectroscopic study of the coupling effect between the two gaps of magnesium diboride on its RF properties

This program studied the two-gap nature of magnesium diboride and its possible effects on the superconducting rf properties of this material. Magnesium diboride (MgB 2 ) is a BCS superconductor with a superconducting critical temperature of 39 K, high critical current density and no weak link behavior across the grain boundary. These properties make this material ideal for both power applications and electronic devices. In particular, the high superconducting critical temperature and high thermodynamic field suggests that MgB 2 could be an ideal material also for superconducting radio frequency (SRF) cavities operating at a much higher temperature than Nb cavities and, therefore, reducing noticeably the cryogenics costs. However, MgB 2 is a two gap superconductor and it has been suggested that the RF properties are dominated by the smaller gap, which would make this material not competitive with Nb and especially Nb 3 Sn. The main problem does not seem to be the double-gap nature of this material but rather the weak-coupling of the two gaps that in the presence of an RF field suppresses superconductivity all together at fields much lower than the thermodynamic field. The main goal of this proposal is to address the fundamental question of the coupling between the two gaps in MgB 2 and understand if it is possible to control it and ultimately improve the RF performance of MgB 2 . The project studied these questions by measuring the density of states in the presence of an in-plane current and focused on the effect of controlled disorder. Disorder, indeed, provides an important knob to tune the properties of MgB2 and provides the possibility of changing the coupling between the two bands, making this material a competitive material for SRF applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Sodium–Antimony–Telluride Intermetallic Allows Sodium-Metal Cycling at 100% Depth of Discharge and as an Anode-Free Metal Battery

In this work, repeated cold rolling and folding is employed to fabricate a metallurgical composite of sodium–antimony–telluride Na 2 (Sb 2/6 Te 3/6 Vac 1/6 ) dispersed in electrochemically active sodium metal, termed “NST-Na.” This new intermetallic has a vacancy-rich thermodynamically stable face-centered-cubic structure and enables state-of-the-art electrochemical performance in widely employed carbonate and ether electrolytes. NST-Na achieves 100% depth-of-discharge (DOD) in 1 m NaPF 6 in G2, with 15 mAh cm –2 at 1 mA cm –2 and Coulombic efficiency (CE) of 99.4%, for 1000 h of plating/stripping. Sodium-metal batteries (SMBs) with NST-Na and Na 3 V 2 (PO 4 ) 3 (NVP) or sulfur cathodes give significantly improved energy, cycling, and CE (>99%). An anode-free battery with NST collector and NVP obtains 0.23% capacity decay per cycle. Imaging and tomography using conventional and cryogenic microscopy (Cryo-EM) indicate that the sodium metal fills the open space inside the self-supporting sodiophilic NST skeleton, resulting in dense (pore-free and solid electrolyte interphase (SEI)-free) metal deposits with flat surfaces. The baseline Na deposit consists of filament-like dendrites and “dead metal”, intermixed with pores and SEI. Density functional theory calculations show that the uniqueness of NST lies in the thermodynamic stability of the Na atoms (rather than clusters) on its surface that leads to planar wetting, and in its own stability that prevents decomposition during cycling.

36 MATERIALS SCIENCE↗

Ambient-Temperature Hydrogen Storage via Vanadium(II)-Dihydrogen Complexation in a Metal-Organic Framework

In this report, the widespread implementation of H 2 as a fuel is currently hindered by the high pressures or cryogenic temperatures required to achieve reasonable storage densities. In contrast, the realization of materials that strongly and reversibly adsorb hydrogen at ambient temperatures and moderate pressures could transform the transportation sector and expand adoption of fuel cells in other applications. To date, however, no adsorbent has been identified that exhibits a binding enthalpy within the optimal range of -15 to -25 kJ/mol for ambient-temperature hydrogen storage. Here, we report the hydrogen adsorption properties of the metal-organic framework (MOF) V 2 Cl 2.8 (btdd) (H 2 btdd, bis(1 H -1,2,3-triazolo[4,5- b ],[4',5'- i ])dibenzo[1,4]dioxin), which features exposed vanadium(II) sites capable of backbonding with weak π acids. Significantly, gas adsorption data reveal that this material binds H 2 with an enthalpy of -21 kJ/mol. This binding energy enables usable hydrogen capacities that exceed that of compressed storage under the same operating conditions. The Kubas-type vanadium(II)-dihydrogen complexation is characterized by a combination of techniques. From powder neutron diffraction data, a V-D 2 (centroid) distance of 1.966(8) Å is obtained, the shortest yet reported for a MOF. Using in situ infrared spectroscopy, the H-H stretch was identified, and it displays a red shift of 242 cm -1 . Electronic structure calculations show that a main contribution to bonding stems from the interaction between the vanadium d π and H 2 σ* orbital. Ultimately, the pursuit of MOFs containing high densities of weakly π-basic metal sites may enable storage capacities under ambient conditions that far surpass those accessible with compressed gas storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗

Neutron imaging of hydrogenous gases in porous-carbon materials around phase transitions

Focus herein is on hydrogenous gases interacting with porous-carbon materials on activated biochar at pressures ranging from 0 to 100 bar and temperatures from room (ambient) to cryogenic. Neutron radiography was conducted using a custom-made cell system to simultaneously image pure gas and gas interacting with the porous carbon. From neutron attenuation, the cross sections of methane and ethane and number concentrations were determined for different pressures and temperatures and compared with corresponding reference data. Sorption properties of the porous materials were investigated in situ with methane, ethane, and propane.

Ossler, Frederik [Lund University, Sweden]↗

Electrified Operando -Freezing of Electrocatalytic CO 2 Reduction Cells for Cryogenic Electron Microscopy

The ability to freeze and stabilize reaction intermediates in their metastable states and obtain their structural and chemical information with high spatial resolution would be very powerful to unravel the fundamentals in many important materials technologies such as catalysis and batteries. Here, we develop an electrified operando-freezing methodology for the first time to preserve these metastable states under electrochemical reaction conditions for cryogenic electron microscopy (cryo-EM) imaging and spectroscopy. Using Cu catalysts for CO 2 reduction as a model system, we observe restructuring of the Cu catalyst in a CO 2 atmosphere while the same catalyst remains intact in an air atmosphere at the nanometer scale. Furthermore, we discover the existence of single valance Cu (1+) state and C-O bonding at the electrified liquid-solid interface of the operando-frozen samples, which are key reaction intermediates that traditional ex situ measurements fail to detect. Finally, this work highlights our novel technique to study the local structure and chemistry of electrified liquid-solid interfaces, which has broad impact for many electrochemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. In this article, we detail the CUPID-Mo detector concept, assembly, installation in the underground laboratory in Modane in 2018, and provide results from the first datasets. The demonstrator consists of an array of 20 scintillating bolometers comprised of $^{100}$Mo-enriched 0.2 kg Li$_2$MoO$_4$ crystals. The detectors are complemented by 20 thin cryogenic Ge bolometers acting as light detectors to distinguish $\alpha$ from $\gamma$/$\beta$ events by the detection of both heat and scintillation light signals. We observe good detector uniformity, facilitating the operation of a large detector array as well as excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Based on the observed energy resolutions and light yields a separation of $\alpha$ particles at much better than 99.9\% with equally high acceptance for $\gamma$/$\beta$ events is expected for events in the region of interest for $^{100}$Mo $0\nu\beta\beta$. We present limits on the crystals' radiopurity ($\leq$3 $\mu$Bq/kg of $^{226}$Ra and $\leq$2 $\mu$Bq/kg of $^{232}$Th). Based on these initial results we also discuss a sensitivity study for the science reach of the CUPID-Mo experiment, in particular, the ability to set the most stringent half-life limit on the $^{100}$Mo $0\nu\beta\beta$ decay after half a year of livetime. In conclusion, the achieved results show that CUPID-Mo is a successful demonstrator of the technology - developed in the framework of the LUMINEU project - selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale cryogenic $0\nu\beta\beta$ experiment.

100Mo↗

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics↗

Advanced Characterization Techniques for Overcoming Challenges of Perovskite Solar Cell Materials

Abstract In the last 10 years, organic–inorganic hybrid perovskite solar cells have achieved unprecedented advances, to the point where they now exhibit extremely high efficiency. However, long‐term stability and areal scalability limitations impede the commercial application of perovskite materials, and appropriate diagnosistic tools have become necessary to evaluate perovskite materials. Characterization of perovskite materials is regularly misinterpretated, due to unique intrinsic and extrinsic factors: degradation from the measurement source, ion migration, phase transition, and separation. Herein, studies on perovskites are reviewed that have used advanced characterization tools to overcome characterization challenges. Cryogenic temperature assisted measurements mitigate degradation or phase transitions induced by the measurement source. In situ measurements can track the variation of perovskite materials depending on external stimuli. Spatial material properties are able to be evaluated by the use of multidimensional mapping techniques. An overview of these advanced characterization tools that can overcome the challenges associated with established tools provides the opportunity for further understanding perovskite materials and solving the remaining challenges on the road to commercialization.

Kim, Min‐cheol↗

Aluminum scandium nitride films for piezoelectric transduction into silicon at gigahertz frequencies

Recent advances in the growth of aluminum scandium nitride films on silicon suggest that this material platform could be applied for quantum electromechanical applications. Here, we model, fabricate, and characterize microwave frequency silicon phononic delay lines with transducers formed in an adjacent aluminum scandium nitride layer to evaluate aluminum scandium nitride films, at 32% scandium, on silicon interdigital transducers for piezoelectric transduction into suspended silicon membranes. We achieve an electromechanical coupling coefficient of 2.7% for the extensional symmetric-like Lamb mode supported in the suspended material stack and show how this coupling coefficient could be increased to at least 8.5%, which would further boost transduction efficiency and reduce the device footprint. The one-sided transduction efficiency, which quantifies the efficiency at which the source of microwave photons is converted to microwave phonons in the silicon membrane, is 10% at 5 GHz at room temperature and, as we discuss, there is a path to increase this toward near-unity efficiency based on a combination of modified device design and operation at cryogenic temperatures.

36 MATERIALS SCIENCE↗