Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Superconducting thermometer for cryogenics

Digital electronic device uses superconducting filaments as sensors. Simple solid-state circuitry combined with filaments comprise highly-reliable temperature monitor. Device has ability to track very fast thermal transients and "on/off" output is adaptable to remote sensing and telemetry.

White, F. A.↗

Development of isothermal rigs

The results of the Resonant Infrasonic Gauging System (RIGS) development program are reported. The RIGS is a gauging system that is capable of measuring propellant quantity under zero-G as well as under accelerated (one-G) conditions. With the exception of liquid hydrogen, it can be used to gauge virtually any propellant in liquid form including cryogenics. The gauge consists of a sensor unit which is attached to the propellant tank and electronic control unit which may be positioned separately from the sensor. The control unit receives the signals from the sensor as well as the ullage gas pressure and propellant temperature measurements, and computes the propellant quantity remaining in the tank. During the course of this program two prototype RIGS sensors were designed and constructed. The sensors were tested first in the laboratory using water as the simulated propellant and, later, using LN2 in a 100-gallon tank. The system tests proved that the gauge operates virtually as predicted by theory and yielded an accuracy better than 1%.

Kaminskas, R. A.↗

Augmented RIGS

The results of the Phase 2 Resonant Infrasonic Gauging System (RIGS) development program are presented. The program consisted of design, fabrication, and testing of an "augmented" RIGS concept. The RIGS is a gauging system capable of measuring propellant quantities in zero-g as well as under accelerated conditions. Except for hydrogen, it can be used to gauge virtually any propellant in liquid form, including cryogenics. The gage consists of a sensor unit which is attached to the propellant tank and an electronic control unit which may be positioned separately from the sensor. The control unit receives signals from the sensor as well as the propellant temperature measurement and the ullage gas pressure, and computes the propellant quantity in the tank.

Kaminskas, R. A.↗

Optimized Geometry for Superconducting Sensing Coils

An optimized geometry has been proposed for superconducting sensing coils that are used in conjunction with superconducting quantum interference devices (SQUIDs) in magnetic resonance imaging (MRI), magnetoencephalography (MEG), and related applications in which magnetic fields of small dipoles are detected. In designing a coil of this type, as in designing other sensing coils, one seeks to maximize the sensitivity of the detector of which the coil is a part, subject to geometric constraints arising from the proximity of other required equipment. In MRI or MEG, the main benefit of maximizing the sensitivity would be to enable minimization of measurement time. In general, to maximize the sensitivity of a detector based on a sensing coil coupled with a SQUID sensor, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. Simply making the coil larger may increase its self-inductance and does not necessarily increase sensitivity because it also effectively increases the distance from the sample that contains the source of the signal that one seeks to detect. Additional constraints on the size and shape of the coil and on the distance from the sample arise from the fact that the sample is at room temperature but the coil and the SQUID sensor must be enclosed within a cryogenic shield to maintain superconductivity.

Eom, Byeong Ho↗

On DESTINY Science Instrument Electrical and Electronics Subsystem Framework

Future space missions are going to require large focal planes with many sensing arrays and hundreds of millions of pixels all read out at high data rates'' . This will place unique demands on the electrical and electronics (EE) subsystem design and it will be critically important to have high technology readiness level (TRL) EE concepts ready to support such missions. One such omission is the Joint Dark Energy Mission (JDEM) charged with making precise measurements of the expansion rate of the universe to reveal vital clues about the nature of dark energy - a hypothetical form of energy that permeates all of space and tends to increase the rate of the expansion. One of three JDEM concept studies - the Dark Energy Space Telescope (DESTINY) was conducted in 2008 at the NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. This paper presents the EE subsystem framework, which evolved from the DESTINY science instrument study. It describes the main challenges and implementation concepts related to the design of an EE subsystem featuring multiple focal planes populated with dozens of large arrays and millions of pixels. The focal planes are passively cooled to cryogenic temperatures (below 140 K). The sensor mosaic is controlled by a large number of Readout Integrated Circuits and Application Specific Integrated Circuits - the ROICs/ASICs in near proximity to their sensor focal planes. The ASICs, in turn, are serviced by a set of "warm" EE subsystem boxes performing Field Programmable Gate Array (FPGA) based digital signal processing (DSP) computations of complex algorithms, such as sampling-up-the-ramp algorithm (SUTR), over large volumes of fast data streams. The SUTR boxes are supported by the Instrument Control/Command and Data Handling box (ICDH Primary and Backup boxes) for lossless data compression, command and low volume telemetry handling, power conversion and for communications with the spacecraft. The paper outlines how the JDEM DESTINY concept instrument EE subsystem can be built now, a design; which is generally U.S. Government work not protected by U.S. copyright IEEEAC paper # 1429. Version 4. Updated October 19, 2009 applicable to a wide variety of missions using large focal planes with lar ge mosaics of sensors.

Kizhner, Semion↗

SIRENA Software for Athena X-IFU Event Reconstruction

The X-ray Observatory Athena was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESAs Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard Athena is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by an international consortium led by IRAP (PI), SRON (co-PI) and IAPS/INAF (co-PI) and involving ESA Member States, Japan and the United States. In Spain, IFCA (CSIC-UC) has an anticipated contribution to X-IFU through the Digital Readout Electronics (DRE) unit, in particular in the Event Processor Subsytem. For this purpose and in collaboration with the Athena end-to-end simulations team, we are currently developing the SIRENA package as part of the publicly available SIXTE end-to-end simulator. SIRENA comprises a set of processing algorithms aimed at recognizing, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, to lately reconstruct their energy, position and arrival time. This poster describes the structure of the package and the different algorithms currently implemented as well as their comparative performance in the energy resolution achieved in the reconstruction of the instrument events.

M T Ceballos↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Arrays of Nano Tunnel Junctions as Infrared Image Sensors

Infrared image sensors based on high density rectangular planar arrays of nano tunnel junctions have been proposed. These sensors would differ fundamentally from prior infrared sensors based, variously, on bolometry or conventional semiconductor photodetection. Infrared image sensors based on conventional semiconductor photodetection must typically be cooled to cryogenic temperatures to reduce noise to acceptably low levels. Some bolometer-type infrared sensors can be operated at room temperature, but they exhibit low detectivities and long response times, which limit their utility. The proposed infrared image sensors could be operated at room temperature without incurring excessive noise, and would exhibit high detectivities and short response times. Other advantages would include low power demand, high resolution, and tailorability of spectral response. Neither bolometers nor conventional semiconductor photodetectors, the basic detector units as proposed would partly resemble rectennas. Nanometer-scale tunnel junctions would be created by crossing of nanowires with quantum-mechanical-barrier layers in the form of thin layers of electrically insulating material between them (see figure). A microscopic dipole antenna sized and shaped to respond maximally in the infrared wavelength range that one seeks to detect would be formed integrally with the nanowires at each junction. An incident signal in that wavelength range would become coupled into the antenna and, through the antenna, to the junction. At the junction, the flow of electrons between the crossing wires would be dominated by quantum-mechanical tunneling rather than thermionic emission. Relative to thermionic emission, quantum mechanical tunneling is a fast process.

Son, Kyung-Ah↗

Non-intrusive speed sensor

In Phase I of the Non-Intrusive Speed Sensor program, a computerized literature search was performed to identify candidate technologies for remote, non-intrusive speed sensing applications in Space Shuttle Main Engine (SSME) turbopumps. The three most promising technologies were subjected to experimental evaluation to quantify their performance characteristics under the harsh environmental requirements within the turbopumps. Although the infrared and microwave approaches demonstrated excellent cavitation immunity in laboratory tests, the variable-source magnetic speed sensor emerged as the most viable approach. Preliminary design of this speed sensor encountered no technical obstacles and resulted in viable and feasible speed nut, sensor housing, and sensor coil designs. Phase II of this program developed the variable-source magnetic speed sensor through the detailed design task and guided the design into breadboard fabrication. The speed sensor and its integral speed nut were evaluated at both unit and system level testing. The final room-temperature and cryogenic spin testing of the hardware demonstrated that the sensor was capable of generating sufficient output signal to enable remote speed sensing from 1500 to 40000 rpm over a speed nut/sensor separation of 3.5 inches.

Wyett, L.↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

Ionic Polymer-Metal Composites (IPMCs) as Biomimetic Sensors, Actuators and Artificial Muscles: A Review

This paper presents an introduction to ionic polymer-metal composites and some mathematical modeling pertaining to them. It further discusses a number of recent findings in connection with ion-exchange polymer-metal composites (IPMCS) as biomimetic sensors and actuators. Strips of these composites can undergo large bending and flapping displacement if an electric field is imposed across their thickness. Thus, in this sense they are large motion actuators. Conversely by bending the composite strip, either quasi-statically or dynamically, a voltage is produced across the thickness of the strip. Thus, they are also large motion sensors. The output voltage can be calibrated for a standard size sensor and correlated to the applied loads or stresses. They can be manufactured and cut in any size and shape. In this paper first the sensing capability of these materials is reported. The preliminary results show the existence of a linear relationship between the output voltage and the imposed displacement for almost all cases. Furthermore, the ability of these IPMCs as large motion actuators and robotic manipulators is presented. Several muscle configurations are constructed to demonstrate the capabilities of these IPMC actuators. This paper further identifies key parameters involving the vibrational and resonance characteristics of sensors and actuators made with IPMCS. When the applied signal frequency varies, so does the displacement up to a critical frequency called the resonant frequency where maximum deformation is observed, beyond which the actuator response is diminished. A data acquisition system was used to measure the parameters involved and record the results in real time basis. Also the load characterizations of the IPMCs were measured and it was shown that these actuators exhibit good force to weight characteristics in the presence of low applied voltages. Finally reported are the cryogenic properties of these muscles for potential utilization in an outer space environment of a few Torrs and temperatures of the order of - 140 degrees Celsius. These muscles are shown to work quite well in such harsh cryogenic environments and thus present a great potential as sensors and actuators that can operate at cryogenic temperatures.

Shahinpoor, M.↗

An Advanced Loop Heat Pipe for Cryogenic Applications

A loop heat pipe (LHP) is a very versatile heat transfer device which can transport a large heat load over a long distance with a small temperature difference. All LHPs currently servicing orbiting spacecraft are designed to operate in the room temperature range. Future space telescopes and space-based Earth resource imaging satellites require passive cryogenic heat transport devices that can thermally couple remote cryocoolers to sensor or instrument of interest while providing the capability of payload vibration/jitter isolation, implementation of redundant coolers, and coupling of multiple sensors to a common heat sink. All of these requirements can be satisfied by using a cryogenic LHP (CLHP). Although the development of CLHPs faces several technical challenges, NASA Goddard Space Flight Center has devoted extensive efforts in developing CLHP technology over the past decade and has made significant progress. In particular, the combination of the innovative ideas of using a secondary capillary pump to manage the parasitic heat gain and using a hot reservoir to reduce the system pressure under the ambient condition has led to the successful development of the CLHP. Several CLHPs charged with nitrogen and hydrogen were built and tested in thermal vacuum chambers. These CLHPs demonstrated reliable start-up and robust operation during power cycle and sink temperature cycle tests.

Loop Heat Pipes↗

An Advanced Loop Heat Pipe for Cryogenic Applications

A loop heat pipe (LHP) is a very versatile heat transfer device that can transport a large heat load over a long distance with a small temperature difference. All LHPs currently servicing orbiting spacecraft are designed to operate in the room temperature range. Future space telescopes and space-based Earth resource imaging satellites require passive cryogenic heat transport devices that can thermally couple remote cryocoolers to sensor or instrument of interest while providing the capability of payload vibration jitter isolation, implementation of redundant coolers, and coupling of multiple sensors to a common heat sink. All of these requirements can be satisfied by using a cryogenic LHP (CLHP). Although the development of CLHPs faces several technical challenges, NASA Goddard Space Flight Center has devoted extensive efforts in developing CLHP technology over the past decade and has made significant progress. In particular, the combination of the innovative ideas of using a secondary capillary pump to manage the parasitic heat gain and using a hot reservoir to reduce the system pressure under the ambient condition has led to the successful development of the CLHP. Several CLHPs charged with nitrogen and hydrogen were built and tested in thermal vacuum chambers. These CLHPs demonstrated reliable start-up and robust operation during power cycle and sink temperature cycle tests.

Loop Heat Pipes↗

An Advanced Loop Heat Pipe for Cryogenic Applications

A loop heat pipe (LHP) is a very versatile heat transfer device that can transport a large heat load over a long distance with a small temperature difference. All LHPs currently servicing orbiting spacecraft are designed to operate in the room temperature range. Future space telescopes and space-based Earth resource imaging satellites require passive cryogenic heat transport devices that can thermally couple remote cryocoolers to sensor or instrument of interest while providing the capability of payload vibration jitter isolation, implementation of redundant coolers, and coupling of multiple sensors to a common heat sink. All of these requirements can be satisfied by using a cryogenic LHP (CLHP). Although the development of CLHPs faces several technical challenges, NASA Goddard Space Flight Center has devoted extensive efforts in developing CLHP technology over the past decade and has made significant progress. In particular, the combination of the innovative ideas of using a secondary capillary pump to manage the parasitic heat gain and using a hot reservoir to reduce the system pressure under the ambient condition has led to the successful development of the CLHP. Several CLHPs charged with nitrogen and hydrogen were built and tested in thermal vacuum chambers. These CLHPs demonstrated reliable start-up and robust operation during power cycle and sink temperature cycle tests.

Loop Heat Pipes↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Radiation Dry Bias of the Vaisala RS92 Humidity Sensor

The comparison of simultaneous humidity measurements by the Vaisala RS92 radiosonde and by the Cryogenic Frostpoint Hygrometer (CFH) launched at Alajuela, Cosla Rica, during July 2005 reveals a large solar radiation dry bias of the Vaisala RS92 humidity sensor and a minor temperature-dependent calibration error. For soundings launched at solar zenith angles between 10" and 30 , the average dry bias is on the order of 9% at the surface and increases to 50% at 15 km. A simple pressure- and temperature-dependent correction based on the comparison with the CFH can reduce this error to less than 7% at all altitudes up to 15.2 km, which is 700 m below the tropical tropopause. The correction does not depend on relative humidity, but is able to reproduce the relative humidity distribution observed by the CFH.

Vomel, H.↗

Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs

Tubes made from biaxially oriented liquid-crystal polymers (LCPs) have been developed for use as penetrations on cryogenic tanks. ( Penetrations in this context denotes feed lines, vent lines, and sensor tubes, all of which contribute to the undesired conduction of heat into the tanks.) In comparison with corresponding prior cryogenic-tank penetrations made from stainless steels and nickel alloys, the LCP penetrations offer advantages of less weight and less thermal conduction. An additional major advantage of LCP components is that one can tailor their coefficients of thermal expansion (CTEs). The estimated cost of continuous production of LCP tubes of typical sizes is about $1.27/ft ($4.17/m) [based on 1998 prices]. LCP tubes that are compatible with liquid oxygen and that feature tailored biaxial molecular orientation and quasi-isotropic properties (including quasi-isotropic CTE) have been fabricated by a combination of proprietary and patented techniques that involve the use of counterrotating dies (CRDs). Tailoring of the angle of molecular orientation is what makes it possible to tailor the CTE over a wide range to match the CTEs of adjacent penetrations of other tank components; this, in turn, makes it possible to minimize differential-thermal expansion stresses that arise during thermal cycling. The fabrication of biaxially oriented LCP tubes by use of CRDs is not new in itself. The novelty of the present development lies in tailoring the orientations and thus the CTEs and other mechanical properties of the LCPs for the intended cryogenic applications and in modifications of the CRDs for this purpose. The LCP tubes and the 304-stainless-steel tubes that the LCP tubes were intended to supplant were tested with respect to burst strength, permeability, thermal conductivity, and CTE.

Rubin, Leslie↗