Search NASA⌕ Search

SEARCH · Search NASA

Results for “customer adoption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decompose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep-learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high-level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for a one-year lead hourly load below $5\%$ MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM: Preprint

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decompose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep-learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high-level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for a one-year lead hourly load below 5% MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Deliberate Design: Creating Electricity Rates with Purpose

Today’s electricity rates often are legacy designs that do not reflect the dynamics of an evolving power grid or align with current policy objectives. Four steps will assist utilities, regulators, and industry stakeholders in modernizing outdated electricity rate designs. 1. Understand the context for rate design change: The power system is changing at a pace that the industry has not experienced for decades. It is essential to understand the implications of these changes so rates can evolve to remain consistent with changes to the underlying cost profile, customer preferences, and power system requirements. 2. Establish ratemaking objectives: Rates can do more than recover utility costs. They can be a tool for promoting desired outcomes such as improved energy affordability, flexible and efficient electricity consumption, or promoting technology adoption. First, these objectives must be clearly defined and prioritized. 3. Account for tradeoffs when designing new rates: Rate design is the art of balancing tradeoffs. It is essential to understand these tradeoffs when designing new rates, particularly if the rates are being used as a tool for accomplishing policy objectives that extend beyond the basic goal of cost reflectivity. 4. Transition to the new rates with a plan: The move to well-designed rates requires a transition plan. This will ensure that rate design changes do not happen in isolation and are consistent with a long-term, holistic vision. The report, published as an interactive web tool for which the content can be separately downloaded as a standalone document, is intended to allow state energy regulators, utility rates staff, and other industry stakeholders with an interest in rate design to selectively “drill down” on content that is relevant to their interests and situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coupled Time-Lapse Full-Waveform Inversion for Subsurface Flow Problems Using Intrusive Automatic Differentiation

We describe a novel framework for estimating subsurface properties, such as rock permeability and porosity, from time-lapse observed seismic data by coupling full-waveform inversion (FWI), subsurface flow processes, and rock physics models. For the inverse modeling, we handle the back propagation of gradients by an intrusive automatic differentiation strategy that offers three levels of user control: (1) At the wave physics level, we adopted the discrete adjoint method in order to use our existing high-performance FWI code; (2) at the rock physics level, we used built-in automatic differentiation operators from the TensorFlow backend; (3) at the flow physics level, we implemented customized partial differential equation (PDE) operators for the multiphase flow equations. The three-level coupled inversion strategy strikes a good balance between computational efficiency and programming efforts, and when the gradients are chained together, it constitutes a coupled inverse system. Our numerical experiments demonstrate that the three-level coupled inverse problem is superior in terms of accuracy to a traditional decoupled inversion strategy. Additionally, our method is able to simultaneously invert for parameters in empirical relationships such as the rock physics models. Our proposed inverted model can be used for reservoir performance prediction and reservoir management/optimization purposes.

54 ENVIRONMENTAL SCIENCES↗

Advancing Solar Innovation for Low and Moderate-Income Households (Final Technical Report)

The overarching goal of this project was to deepen the understanding of the social and economic aspects of solar adoption, with a specific eye towards any pathways or barriers that could be identified that directly impact low and moderate-income households. Specific objectives included (1) identifying and assessing significant non-economic barriers that complicate the ability of LMI households to adopt and benefit from solar, even under scenarios with low economic barriers; (2) assessing the differential ability of groups to benefit from solar adoption based on their ability to invest in different solar innovations; (3) explaining why some LMI communities nonetheless experience significantly higher rates of solar adoption and benefit than others; (4) developing a methodological model for generating data addressing key issues to the project; and (5) designing and developing an interactive web portal that aggregates existing datasets, provides researchers trend analysis capabilities, standardizes project protocols for other states and communities; provides the opportunities for researchers using the same protocol in other communities to upload their results; and engages with the general public by providing them the ability to upload their own perspectives and stories of solar technology adoption. Through a common framework for conducting semi-structured field interviews. In partnership with cooperative extension services, in conjunction with survey research and the aggregation of existing solar adoption datasets, this study has identified that currently ,there is a strong values alignment and knowledge access challenge that continues to affect solar adoption. Participants in this study – many of whom are either low or moderate-income and/or live in underserved rural communities do not believe solar is an option where they live or believe solar is appropriate for their lifestyle. This perception challenge is further exacerbated by the absolute dearth of adopters in most communities and a total lack of local marketing for solar energy. What marketing that does exist is geared towards audiences other than those in the participant's community, reinforcing a perception that 22% of survey respondents (n = 1,551) have: that solar energy is not meant for them and their community. Overcoming these serious human challenges pertaining to knowledge and marketing are critical to reducing the customer acquisition costs incurred amongst LMI communities and especially those in rural America where the opportunities solar provides to increase local energy resilience, security, all while engaging in personal stewardship of the planet could align with local values. Community-Based Social Marketing, built in partnership with community leaders and geared towards meeting local visions of ideal life, is a near term opportunity to bridge the gap between local priorities and national market and policy imperatives for solar while moving towards the administration's goals for renewable energy as part of a just and equitable decarbonization program. The tools and methods developed for this study can serve as a template for identifying other specific local challenges for solar adoption in other state, and provide the opportunity for a common data framework for understanding system-wide trends and barriers to achieving uptake of residential solar in communities that may, ultimately, benefit the most from the technology.

14 SOLAR ENERGY↗

Electric vehicle supply equipment location and capacity allocation for fixed-route networks

Electric vehicle (EV) supply equipment location and allocation (EVSELCA) problems for freight vehicles are becoming more important because of the trending electrification shift. Some previous works address EV charger location and vehicle routing problems simultaneously by generating vehicle routes from scratch. Although such routes can be efficient, introducing new routes may violate practical constraints, such as drive schedules, and satisfying electrification requirements can require dramatically altering existing routes. To address the challenges in the prevailing adoption scheme, we approach the problem from a fixed -route perspective. We develop a mixed -integer linear program, a clustering approach, and a metaheuristic solution method using a genetic algorithm (GA) to solve the EVSELCA problem. The clustering approach simplifies the problem by grouping customers into clusters, while the GA generates solutions that are shown to be nearly optimal for small problem cases. A case study examines how charger costs, energy costs, the value of time (VOT), and battery capacity impact the cost of the EVSELCA. Charger equipment costs were found to be the most significant component in the objective function, leading to a substantial reduction in cost when decreased. VOT costs exhibited a significant decrease with rising energy costs. Further, an increase in VOT resulted in a notable rise in the number of fast chargers. Longer EV ranges decrease total costs up to a certain point, beyond which the decrease in total costs is negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Hand me the franchise agreement: municipalities add another policy tool to their clean energy toolbox

A growing list of the more than 20,000 municipalities in the United States are considering pathways to achieve renewable energy goals. One emerging trend is for municipalities to incorporate energy objectives into their franchise agreements with an electric service provider. Franchise agreements are contracts between municipalities and utilities that grant the utility authority to serve customers in the municipality. In some cases, municipalities have negotiated renewable energy objectives into these agreements. It is still unclear how many municipalities have exercised this authority and to what effect. From a national dataset of 3500 franchise agreements, we selected five cities that adopted renewable energy or energy efficiency objectives into or alongside their franchise agreements for deeper analysis: Chicago, Illinois; Denver, Colorado; Sarasota, Florida; Minneapolis, Minnesota; and Salt Lake City, Utah. We generated seven key takeaways for other cities considering this pathway to achieve their energy objectives. In summary, municipalities can leverage franchise negotiations to pursue both modest and ambitious clean energy goals (i.e. 100% renewable electricity). This study provides municipalities with critical insight on how they can use this potentially formidable tool to achieve their own energy objectives.

14 SOLAR ENERGY↗

Rooftop Solar Deployment, Potential Electricity Rate Impacts, and the Timing of Revisions to State Net Metering Policy

Most U.S. states require utilities to credit residential solar photovoltaic (PV) output at the retail electricity rate, a structure known as net metering. However, 12 states have replaced net metering with alternative rate structures that reduce PV adopter bill savings. The share of households living in states that require net metering fell from around 84% in 2014 to around 57% by the end of 2023. Proponents of net metering revisions have argued that net metering can affect the electricity rates of customers without PV. This report analyzes the relationships between state PV deployment levels, potential electricity rate impacts on PV nonadopters, and the timing of revisions to net metering policy.

14 SOLAR ENERGY↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Regulatory and Technical Challenges and Barriers to Adoption of Distributed Wind Energy in Agricultural Settings

Distributed wind (DW) energy development can benefit agricultural landowners through the possibility of improved resilience of electrical service from onsite generation and associated economic benefits. DW development currently faces technical and regulatory challenges related to interconnection of projects with distribution or transmission equipment on the main electrical grid. A review was conducted of barriers to adoption for agricultural DW projects and potential roles of various stakeholders in addressing them. One major barrier is that the unique characteristics of wind energy generation such as its variability and intermittency, may require upgrades for the whole power line, which can lead to prohibitive cost burdens on individual interconnection customers. Another barrier is compliance with federal, state, or utility-level regulations that require technology-agnostic, industry-standard equipment that is often not technically realistic for DW projects. DW developers, grid infrastructure owner-operators, regulators, and standards publishers can work together to address these challenges and facilitate DW development.

17 WIND ENERGY↗

White Box Access to Quantum Testbeds for Co-Design

At Lawrence Livermore National Laboratory (LLNL), we operate and maintain the Quantum Device and Integration Testbed (QuDIT) facility, a small quantum testbed that supports about 10 active research teams (including our own) and over 50 internal and external collaborators. This testbed is designed to give remote white box access to users for research, training, and outreach. A guiding principle behind the development of our testbed infrastructure, software and user interfaces is to empower users to perform experiments at the cutting edge of quantum information science at any level of abstraction, from materials studies, device physics and control and characterization techniques to algorithm development and quantum operating system design. Our testbed targets a multilevel quantum system (qudit) to expand the accessible Hilbert space of a simple-to-manufacture quantum device and focuses on quantum simulation, typically implemented through custom gates designed with quantum optimal control methods, rather than on a universal computing framework with a fixed gate set. We leverage the Lab’s high-performance computing (HPC) program and related expertise to simulate quantum systems, develop hybrid algorithms, and generate gates optimized for given simulations. Additionally, we have adopted a co-design philosophy from the HPC community in designing new hardware, so that the systems we develop are optimized for the specific physics simulations we plan to use them for.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗