Search NASA⌕ Search

SEARCH · Search NASA

Results for “data guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Wind shear modeling for aircraft hazard definition

Mathematical models of wind profiles were developed for use in fast time and manned flight simulation studies aimed at defining and eliminating these wind shear hazards. A set of wind profiles and associated wind shear characteristics for stable and neutral boundary layers, thunderstorms, and frontal winds potentially encounterable by aircraft in the terminal area are given. Engineering models of wind shear for direct hazard analysis are presented in mathematical formulae, graphs, tables, and computer lookup routines. The wind profile data utilized to establish the models are described as to location, how obtained, time of observation and number of data points up to 500 m. Recommendations, engineering interpretations and guidelines for use of the data are given and the range of applicability of the wind shear models is described.

Frost, W.↗

Development of user guidelines for ECAS display design, volume 1

Experiment computer application software (ECAS) display design and command usage guidelines were developed, which if followed by spacelab experiments, would standardize methods and techniques for data presentation and commanding via ECAS. These guidelines would provide some commonality among experiments which would enhance crew training and flight operations. The guidelines are applicable to all onboard experiment displays, whether allocated by ECAS or a dedicated experiment processor. A brief description of the spacelab data display system characteristics and of the services provided by the experiment computer operating system is included. Guidelines concerning data presentation and layout of alphanumeric and graphic information are presented along with guidelines concerning keyboard commanding and command feedback.

Dodson, D. W.↗

Finding the forest in the trees. The challenge of combining diverse environmental data

Development of analytical and functional guidelines to help researchers and technicians engaged in interdisciplinary research to better plan and implement their supporting data management activities is addressed. An emphasis is on the projects that involve both geophysical and ecological issues. Six case studies were used to identify and to understand problems associated with collecting, integrating, and analyzing environmental data from local to global spatial scales and over a range of temporal scales. These case studies were also used to elaborate the common barriers to interfacing data of disparate sources and types. A number of lessons derived from the case studies are summarized and analyzed.

Source record↗

Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018

Ground-based transient electromagnetic (TEM) data were acquired in selected locations around Belle Creek, Montana to define the resistivity structure of the near surface. Data were acquired using the ABEM WalkTEM system (Guideline Geo Ab, Sundbyberg, Sweden). TEM data were processed and numerically inverted to derive one-dimensional resistivity structure using SPIA (Aarhus Geosoftware, Aarhus, Denmark). This release includes raw and processed TEM data and resistivity models for each data location using the following structure: Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.xml SBC_TEM_2019_SoundingLocationsModels.gdb.zip - file geodatabase with all models and plots attached. This is a mirror of the contents of the model directory. Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.zip Data SBC_USF - raw data USF_format_description.pdf - manual describing the USF file format SBC_SoundingID-USF_lookup.csv - table describing the USF file naming convention and channel mapping *.usf files - raw, unprocessed data files SBC_TEM - processed data AarhusInv_manual.pdf - manual describing the TEM file format *.tem files - processed data files Models SBC_Model_Plots - plots of the data and the models for each sounding location TEM_model_data_dictionary.csv - data dictionary describing tabulated models SBC_TEM_models.csv - tabulated models

geophysical surveying↗

High Temperature Materials Interim Data Qualification Report FY 2011

Projects for the very high temperature reactor (VHTR) Technology Development Office provide data in support of Nuclear Regulatory Commission licensing of the VHTR. Fuel and materials to be used in the reactor are tested and characterized to quantify performance in high temperature and high fluence environments. The VHTR program has established the Next Generation Nuclear Plant (NGNP) Data Management and Analysis System (NDMAS) to ensure that VHTR data are qualified for use, stored in a readily accessible electronic form, and analyzed to extract useful results. This document focuses on the first NDMAS objective. It describes the High Temperature Materials characterization data stream, the processing of these data within NDMAS, and reports the interim fiscal year (FY) 2011 qualification status of the data. Data qualification activities within NDMAS for specific types of data are determined by the data qualification category assigned by the data generator. The High Temperature Materials data are being collected under the Nuclear Quality Assurance (NQA)-1 guidelines and will be qualified data. For NQA-1 qualified data, the qualification activities include: (1) capture testing to confirm that the data stored within NDMAS are identical to the raw data supplied, (2) accuracy testing to confirm that the data are an accurate representation of the system or object being measured, and (3) documenting that the data were collected under an NQA-1 or equivalent Quality Assurance program. Currently, data from seven test series within the High Temperature Materials data stream have been entered into the NDMAS vault, including tensile tests, creep tests, and cyclic tests. Of the 5,603,682 records currently in the vault, 4,480,444 have been capture passed, and capture testing is in process for the remaining 1,123,238.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-F-304-05: Cranial TCP/NTCP Modeling Insights and Caveats

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-00: Outcomes of Hypofractionated Treatments - Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-01: Overview of the Working Group On Stereotactic Body Radiation Therapy (WGSBRT)

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-02: Recurrent HNC Treated with SBRT: TCP-Based Outcome Estimates

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

Potential role of remote sensing in disaster relief management

Baseline or predisaster data which would be useful to decision making in the immediate postdisaster period were suggested for the six areas of public health concern along with guidelines for organizing these data. Potential sources of these data are identified. In order to fully assess the impact of a disaster on an area, information about its predisaster status must be known. Aerial photography is one way of acquiring and recording such data.

Rush, M.↗

Catalytic Upgrading of Pyrolysis Products for the Production of Sustainable Aviation Fuel

The objective of this project is advance the state-of-technology for a catalytic fast pyrolysis (CFP) + hydrotreating (HT) process to produce sustainable aviation fuel and other biogenic products. Our approach focuses on performing integrated experiments using realistic biomass feedstocks and non-noble metal technical catalyst formulations. CFP is performed in an ex-situ configuration using a fluidized bed reactor without co-fed hydrogen. Research advancements over the past two years include establishing benchmark yield structures and compositional data for each step of the biomass-to-SAF process, demonstrating the ability to produce a cycloalkane-rich SAF product that meets key ASTM 4054 guidelines, generating benchmark characterization data for technical catalyst formulations with an emphasis on determining the unique composition and combustion properties of biogenic coke, and establishing bio-oil critical material attributes to mitigate the risk of plugging during down-stream hydroprocessing. Other impacts from this project include generation of broadly enabling scientific knowledge (12 publications/12 presentations since 2021), engagement with industry partners (Johnson Matthey, ExxonMobil, Phillips 66), and identification of a promising pathway to market that addresses emerging demands for biogenic refinery feedstocks.

biomass↗

Data Recipes: Toward Creating How-To Knowledge Base for Earth Science Data

Both the diversity and volume of Earth science data from satellites and numerical models are growing dramatically, due to an increasing population of measured physical parameters, and also an increasing variety of spatial and temporal resolutions for many data products. To further complicate matters, Earth science data delivered to data archive centers are commonly found in different formats and structures. NASA data centers, managed by the Earth Observing System Data and Information System (EOSDIS), have developed a rich and diverse set of data services and tools with features intended to simplify finding, downloading, and working with these data. Although most data services and tools have user guides, many users still experience difficulties with accessing or reading data due to varying levels of familiarity with data services, tools, and or formats. The data recipe project at Goddard Earth Science Data and Information Services Center (GES DISC) was initiated in late 2012 for enhancing user support. A data recipe is a How-To online explanatory document, with step-by-step instructions and examples of accessing and working with real data (http:disc.sci.gsfc.nasa.govrecipes). The current suite of recipes has been found to be very helpful, especially to first-time-users of particular data services, tools, or data products. Online traffic to the data recipe pages is significant, even though the data recipe topics are still limited. An Earth Science Data System Working Group (ESDSWG) for data recipes was established in the spring of 2014, aimed to initiate an EOSDIS-wide campaign for leveraging the distributed knowledge within EOSDIS and its user communities regarding their respective services and tools. The ESDSWG data recipe group is working on an inventory and analysis of existing data recipes and tutorials, and will provide guidelines and recommendation for writing and grouping data recipes, and for cross linking recipes to data products. This presentation gives an overview of the data recipe activites at GES DISC and ESDSWG. We are seeking requirements and input from a broader data user community to establish a strong knowledge base for Earth science data research and application implementations.

data recipe↗

Guideline requirements for serviceable spacecraft grasping/berthing/docking interfaces based on simulations and flight experience (survey paper)

As space vehicles and structures become larger and more complex, the development of systems to assist humans in assembling, operating, maintaining, and performing space rescue or retrieval of these vehicles and structures becomes increasingly important. With the diversity of international spacecraft, both manned and unmanned, planned to be in orbit in the future, a set of guidelines for berthing and docking subsystems is mandatory if servicing, resupply, and retrieval is to become practical on an international level. Successful interaction between these space systems and ground and/or space-based humans requires standardized and effective operational interface designs, particularly with respect to space grasping/berthing/docking interface mechanisms. This paper defines the spacecraft mechanical interfaces necessary to create a standard dynamic envelope for joining two free-flying spacecraft in a 'hard' berth or dock with each other in space. A review was made of past space flights and dynamics simulations dating back to 1962 to obtain necessary parameters and their values for successful manually controlled and autonomous spacecraft docking/berthing. The various spacecraft docking/berthing mechanisms and concepts are illustrated along with their dynamic capture and impact tolerances including maximum contact velocity along the approach axis and in the y-z plane; capture linear misalignment tolerances; and maximum capture roll, pitch, and yaw angles. From this data sets of recommended guidelines parameters were developed for autonomous and manual impact docking tolerances, non-impact grasping/berthing tolerances (end effectors), berthing contact conditions, and alignment tolerances after rigidizing. Also, detailed requirements were developed for mechanical design interface features, as well as latching, unlatching, and separation tolerances. This data was drafted in the form of a proposed ANSI Standard guideline, reviewed, and added to by members of the committee representing several spacecraft manufacturers, NASA, and the USAF, and a consensus was reached.

Thompson, Allen B.↗

Multi-Variable Parametric Analysis of Prototype Building Energy Performance Using Current and Future Weather Scenarios For Data-Driven Market Transformation Support

This project aimed to develop a public building simulation data set that may be used to inform building code development and guidelines for building innovation. The data set consists of several common building types and many representative locations across the United States. A parametric design of building properties was developed to create a range of building energy models that represent common building design decisions with a particular focus on fenestration options. The US Department of Energy prototype building energy models were altered according to a parametric building design and simulated using both current weather data and future weather estimates derived from global climate models. The resulting data set allows for pertinent exploration of building design parameters, including fenestration, within different environments across the United States in the broader context of climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing guideline for single event gate rupture (SEGR) of power MOSFETs

The purpose of this document is two-fold. First, the document lists and discusses many of the issues important to understand when testing power MOSFETs. Second, the recommended approach for using radiation test data to define the device application requirements is presented. These include SEE rate calculation, data analysis, and derating guidelines. A significant amount of work has been done on the basic effects of SEB and SEGR. References are supplied where seminal work has been done on the topic at hand. The reader is urged to review the references if the testing issues or mission application at hand are complex.

Scheick, Leif↗