Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Energetic ion mass spectrometer

A new type of spectrometer for space application has been developed to measure separately mass/charge and the three-dimensional velocity distribution of incident ions. The instrument has relatively high resolution and allows rapid measurement of the four-dimensional set of mass/charge, speed, elevation angle, and azimuth angle. The instrument includes a sector magnet, an electrostatic deflector, microchannel plate detectors with position sensitive readout, and a set of grids with variable applied voltage.

Neugebauer, M.↗

Investigation of Radiometric Properties of LANDSAT-4 MSS

Two full frames of radiometrically corrected (Type A) LANDSAT-4 MSS data were analyzed digitally and visually for evidence of residual calibration differences between detectors, quantization effects, and other sensor-related artifacts. Both standard statistical and Fourier analysis techniques were employed. Opportunities for coincident coverage by LANDSAT 3 and 4 were identified in the contiguous 48 states. Paired acquisitions for two scenes were obtained and analyzed to establish relatonships between signal values from common areas imaged by the MSS systems. Another pair with coverage by LANDSAT 2 and 4 was obtained and analyzed. Detector-to-detector differences, coherent noise, line length variation, and LANDSAT 4 to LANDSAT 3 calibration are discussed.

Rice, D. R.↗

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.↗

Spectral slicing X-ray telescope

Layered synthetic microstructure (LSM) X-ray optics is investigated as a system for coupling a conventional glancing incidence X-ray mirror to a high sensitivity X-ray detector. It is shown that, by the use of figured LSM optics, it is possible to magnify the X-ray image produced by the primary mirrors so as to maintain their high inherent spatial resolution. The results of theoretical and design analyses of several spectral slicing X-ray telescope systems that utilize LSM mirrors of hyperboloidal, spherical, ellipsoidal, and constant optical path aspheric configurations are presented. It is shown that the spherical LSM optics are the preferred configuration, yielding subarcsecond performance over the entire field. The Stanford/Marshall Space Flight Center Rocket X-ray Telescope, which will utilize normal incidence LSM optics to couple a Wolter-Schwarzschild primary mirror to high resolution detectors for solar X-ray/EUV studies, is discussed. Design diagrams are included.

Hoover, R. B.↗

Self-structured, current aperture approach for bubble memory

An approach to magnetic bubble memory which incorporates dual conductor current access drive with a self-structured (strongly interacting) bubble lattice is described. This is expected to provide higher operating speeds, defect tolerance, and higher bit density for a given bubble size as compared to present field access bubble devices. Bubble spacings of 2.5 bubble diameters are projected for a prototype device. Experimental work on device components including detectors, major/minor loops, and gates is described. Defect tolerance has also been demonstrated.

Nelson, G. L.↗

Performance of the FOS Detectors in a Variable External Magnetic Field

We present the results of an investigation of the in-orbit performance of the Digicon detectors in the Faint Object Spectrograph (FOS), conducted as part of the commissioning phase of the Hubble Space Telescope. This paper includes orbital results on detector background noise, sensor image stability, and photometric stability along with several typical FOS observations. New techniques for suppressing cosmic ray induced background and geomagnetic induced image motion in electron tube detectors are also discussed.

Fitch, J. E.↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

Thin Film Thermal Conductivity Measurements using Superconducting Nanowires

We present a simple experimental scheme for estimating the cryogenic thermal transport properties of thin films using superconducting nanowires. In a parallel array of nanowires, the heat from one nanowire in the normal state changes the local temperature around adjacent nanowires, reducing their switching current. Calibration of this change in switching current as a function of bath temperature provides an estimate of the temperature as a function of displacement from the heater. This provides a method of determining the contribution of substrate heat transport to the cooling time of superconducting nanowire single photon detectors. Understanding this process is necessary for successful electrothermal modeling of superconducting nanowire systems.

Shaw, M. D.↗

Compact Full-Field Ion Detector System for SmallSats Beyond LEO

NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop a Compact Full-Field Ion Detector System (CFIDS). The CFIDS is designed to be an extremely compact, low cost instrument, capable of being flown on a wide variety of deep space platforms, to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments.

Semiconductors (materials)↗

Prospects for Observing and Localizing Gravitational-Wave Transients with Advanced LIGO and Advanced Virgo

We present a possible observing scenario for the Advanced LIGO and Advanced Virgo gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We determine the expected sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron-star systems, which are considered the most promising for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and 90% credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5 sq. deg to 20 sq. deg will require at least three detectors of sensitivity within a factor of approximately 2 of each other and with a broad frequency bandwidth. Should the third LIGO detector be relocated to India as expected, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.

counterparts↗

System Design and Implementation of the Detector Assembly of the Astro-H Soft X-Ray Spectrometer

The soft x-ray spectrometer (SXS) onboard Astro-H presents to the science community unprecedented capability (less than 7 eV at 6 keV) for high-resolution spectral measurements in the range of 0.5-12 keV to study extended celestial sources. At the heart of this SXS is the x-ray calorimeter spectrometer (XCS) where detectors (calorimeter array and anticoincidence detector) operate at 50 mK, the bias circuit operates at nominal 1.3 K, and the first stage amplifiers operateat 130 K, all within a nominal 20 cm envelope. The design of the detector assembly in this XCS originates from the Astro-E x-ray spectrometer (XRS) and lessons learned from Astro-E and Suzaku. After the production of our engineering model, additional changes were made in order to improve our flight assembly process for better reliability and overall performance. In this poster, we present the final design and implementation of the flight detector assembly, show comparison of parameters and performance to Suzakus XRS, and list susceptibilities to other subsystems as well as our lessons learned.

soft x-ray spectrometer↗

An ultraviolet spectrograph using an echelle grating with cross-disperser for the measurement of stratospheric constituents

The present investigation is concerned with the development of a high resolution echelle-cross disperser grating spectrograph for application in groundbased, balloon, and Shuttle studies of the middle atmosphere and thermosphere. All the design features discussed pertain specifically to the balloon instrument. Attention is given to examples of scientific objectives for the middle atmosphere, aspects of instrument description, imaging requirements, the spectral multiplexing capability, broad wavelength coverage, sensitivity, dynamic range, scattered light, the optical configuration of the instrument, the detector system, the data system, and the results of laboratory tests and theoretical evaluations.

Torr, D. G.↗

Double passing the Kitt Peak 1-m Fourier transform spectrometer

Attention is given to a simple technique for performing the conversion of the Kitt Peak 1-m Fourier transform spectrometer's dual input/output optical configuration to a double pass configuration that improves spectral resolution by a factor of 2. The modification is made by placing a flat mirror in the output beam from each cat's eye, retroreflecting the beams back through the cat's eyes to the first beam splitter. A single detector is placed at the second input port, which then becomes the instrument's output.

Jennings, D. E.↗

Si:As BIB detector arrays

Highlights of the results obtained on arsenic-doped silicon blocked impurity band (BIB) detectors and arrays since the invention of the BIB concept a few years ago are presented. After a brief introduction and a description of the BIB concept, data will be given on single detector performance. Then different arrays that were fabricated will be described and test data presented.

Bharat, R.↗

Design and status of the detector block for the ISO-SWS

The Short Wave Spectrometer (SWS) is one of the two spectrometers for the Infrared Space Observatory (ISO). It consists of a pair of grating spectrometers and a Fabry-Perot interferometer. Together, the grating spectrometers cover the wavelength range 2.4 to 45 microns, at a resolution between 1000 and 2000. The Fabry-Perot interferometer, in series with one of the grating spectrometers, provides a resolution of about 20,000 at the wavelengths between 15 and 35 microns. The SWS is being built by the Space Research Organization of the Netherlands and the Max Planck Institute for Extraterrestrial Physics in Garching, Germany. The spectrometer has 52 discrete detectors, most of which are bulk detectors. In the design of the spectrometer, the main emphasis is on the sensitivity of the individual channels, rather than on the number of detectors. This was one of the main reasons to select non-destructive read-out circuits, with a separate heated-JFET pre-amplifier for each individual detector. The signals are amplified and filtered in parallel. The engineering tests on the SWS detector block have not yet been completed. The design of the detector block is described and the present problem areas are indicated.

Luinge, W.↗