Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Digital pixel test structures implemented in a 65 nm CMOS process

The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20–40 µm and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article. The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at + 20 °C and a detection efficiency of 99% for a DPTS irradiated with a dose of 10 15 1 MeV n eq cm -2 . Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the angular distribution of wavelength-shifted light emitted by TPB

We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to 128 nm light, which is the peak of the liquid Argon (LAr) scintillation spectrum, in vacuum. Films ranging from 250 nm to 5.5 μm in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to that produced by a detailed Monte Carlo model are also presented. The current shortcomings of the model are discussed and future plans briefly outlined.

47 OTHER INSTRUMENTATION↗

Quantum sensing for fundamental physics efforts at SQMS

One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.

Giaccone, Bianca↗

Characterization of silicon drift detectors with electrons for the TRISTAN project

Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision β-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector’s response to electrons on the final sterile neutrino sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three dimensional low-mode areal-density non-uniformities in indirect-drive implosions at the National Ignition Facility

To achieve hotspot ignition, an inertial confinement fusion implosion must achieve high hotspot pressure that is inertially confined by a dense shell of DT fuel. This requires a symmetric implosion having high in-flight shell velocity and high areal density at stagnation. The size of the driver and scale of the capsule required can be minimized by maintaining a high efficiency of energy coupling from the imploding shell to the hotspot. Significant 3D low mode asymmetries, however, are commonly observed in indirect-drive implosions and reduce the coupling of shell kinetic energy to the hotspot. To better quantify the magnitudes and impacts of shell density asymmetries, we have developed new analysis techniques and analytic models [Hurricane et al., Phys. Plasmas 27(6), 062704 (2020)]. To build confidence in the underlying data, we have also developed an analytic neutron transport model to cross-compare two independent measurements of asymmetry, which shows excellent agreement across shots for mode-1 (ℓ = 1). This work also demonstrates that asymmetry can introduce potential sampling bias into down-scattered ratio measurements causing the solid-angle-average and uncertainty-weighted-average down-scattered ratios to differ significantly. Diagnosing asymmetries beyond mode-1 (ℓ > 1) presents significant challenges. Using new diagnostic instruments and analysis techniques, however, evidence of significant Legendre mode P2 (ℓ = 2, m = 0) and additional 3D asymmetries (ℓ > 1, m ≠ 0) are beginning to emerge from the high precision activation diagnostic data (real-time nuclear activation detectors) and down-scattered neutron imaging data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring quasiparticle dynamics for particle impact reconstruction in a superconducting qubit chip

Quasiparticle poisoning following particle impacts poses a significant challenge to the development of fault-tolerant superconducting quantum computers, as a sudden excess of quasiparticles can simultaneously degrade the coherence of multiple qubits across large device arrays. In this work, we present a statistical analysis that models the time evolution of radiation-induced qubit energy relaxation through quasiparticle density dynamics. This study provides insight into quasiparticle loss processes by distinguishing between recombination and trapping decay channels and assessing their respective impact on qubit performance. We precisely measure quasiparticle recombination in multiple transmon qubits and uncover an unexpected dependence of qubit relaxation dynamics on deposited energy. By linking correlated relaxation events across qubits to ballistic phonon propagation, we introduce a statistical localization approach to extract the energy deposited in the substrate, which is in good agreement with Monte Carlo simulation. This work establishes the quantitative framework for using an arbitrary subset of superconducting transmon qubits in a QPU as energy-resolving witness particle detectors.

Celi, E. [Northwestern U.]↗

Overhaul and installation of the ICARUS-T600 liquid argon TPC electronics for the FNAL Short Baseline Neutrino program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016–2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Quantum Nature and Mass of the Neutrino. FY20 Annual Laboratory Continuation Progress Report

Over the last 100 years we have learned a much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing experiments to measure the mass and the quantum nature of the neutrino. The 2015 long range plan recommended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time project chamber called nEXO. On a longer time scale, LLNL is also developing technology to measure the neutrino mass with tritium decay experiments. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to develop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. The Project 8 effort is solely funded by LLNL LDRD, and ends this year. A second LDRD effort is focused on repurposing cyclotron radiation emission spectroscopy for eV-scale X-ray detection. This second effort, while separated from Project 8, still has scientific and technical commonalities with Project 8. The funding for this X-ray detection effort will continue for one more year. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP.We have the tools, skills, people and motivation to make nEXO a reality. The current program development dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews that lie ahead, to develop the draft plans and structure to manage the project as well as setting up an external advisory committee. The current LDRD is exploring alternatives that effect the risk profile as well as possible performance improvements. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the understanding of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. The results of this effort are reported elsewhere, but the scope of this executed at LLNL will be reported here and is primarily the engineering and construction of the LXTS experiment. The primary technical contribution of LLNL to the Project 8 concept is the formation and study of atomic tritium. Atomic tritium is necessary for Project 8 to reach the ultimate sensitivity. LLNL has considerable experience with tritium and is well suited for this crucial work. Although the focus of this work is strictly fundamental science, there has already been one significant spinoff to develop a new means to measure radio xenon in the air

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗