Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Large 0/12 GMT Differences of US Vaisala RS80 Observations

Large differences been observations taken at 0 and 12 GMT have been revealed during routine monitoring of observations at the Data Assimilation Office (DAO) at NASA's Goddard Space Flight Center (GSFC). As a result, an investigation has been conducted to confirm the large differences and isolate its source. The data clearly shows that 0/12 GMT differences are largely artificial especially over the central US and that the differences largely originate in the post processing software at the observing stations. In particular, the release time of the rawinsonde balloon may be misspecified to be the synoptic time which would lead to the miscalculation of the bias correction that accounts for solar radiation effects on the thermistor.

Atlas, Robert↗

Discontinuous Spectral Difference Method for Conservation Laws on Unstructured Grids

A new, high-order, conservative, and efficient discontinuous spectral finite difference (SD) method for conservation laws on unstructured grids is developed. The concept of discontinuous and high-order local representations to achieve conservation and high accuracy is utilized in a manner similar to the Discontinuous Galerkin (DG) and the Spectral Volume (SV) methods, but while these methods are based on the integrated forms of the equations, the new method is based on the differential form to attain a simpler formulation and higher efficiency. Conventional unstructured finite-difference and finite-volume methods require data reconstruction based on the least-squares formulation using neighboring point or cell data. Since each unknown employs a different stencil, one must repeat the least-squares inversion for every point or cell at each time step, or to store the inversion coefficients. In a high-order, three-dimensional computation, the former would involve impractically large CPU time, while for the latter the memory requirement becomes prohibitive. In addition, the finite-difference method does not satisfy the integral conservation in general. By contrast, the DG and SV methods employ a local, universal reconstruction of a given order of accuracy in each cell in terms of internally defined conservative unknowns. Since the solution is discontinuous across cell boundaries, a Riemann solver is necessary to evaluate boundary flux terms and maintain conservation. In the DG method, a Galerkin finite-element method is employed to update the nodal unknowns within each cell. This requires the inversion of a mass matrix, and the use of quadratures of twice the order of accuracy of the reconstruction to evaluate the surface integrals and additional volume integrals for nonlinear flux functions. In the SV method, the integral conservation law is used to update volume averages over subcells defined by a geometrically similar partition of each grid cell. As the order of accuracy increases, the partitioning for 3D requires the introduction of a large number of parameters, whose optimization to achieve convergence becomes increasingly more difficult. Also, the number of interior facets required to subdivide non-planar faces, and the additional increase in the number of quadrature points for each facet, increases the computational cost greatly.

Liu, Yen↗

Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: real-time three-dimensional echocardiography study

BACKGROUND: This study was conducted to elucidate the geometric differences of the mitral apparatus in patients with significant mitral regurgitation caused by ischemic cardiomyopathy (ICM-MR) and by idiopathic dilated cardiomyopathy (DCM-MR) by use of real-time 3D echocardiography (RT3DE). METHODS AND RESULTS: Twenty-six patients with ICM-MR caused by posterior infarction, 18 patients with DCM-MR, and 8 control subjects were studied. With the 3D software, commissure-commissure plane and 3 perpendicular anteroposterior (AP) planes were generated for imaging the medial, central, and lateral sides of the mitral valve (MV) during mid systole. In 3 AP planes, the angles between the annular plane and each leaflet (anterior, Aalpha; posterior, Palpha) were measured. In ICM-MR, Aalpha measured in the medial and central planes was significantly larger than that in the lateral plane (39+/-5 degrees, 34+/-6 degrees, and 27+/-5 degrees, respectively; P<0.01), whereas Palpha showed no significant difference in any of the 3 AP planes (61+/-7 degrees, 57+/-7 degrees, and 56+/-7 degrees, P>0.05). In DCM-MR, both Aalpha (38+/-8 degrees, 37+/-9 degrees, and 36+/-7 degrees, P>0.05) and Palpha (59+/-6 degrees, 58+/-5 degrees, and 57+/-6 degrees, P>0.05) revealed no significant differences in the 3 planes. CONCLUSIONS: The pattern of MV deformation from the medial to the lateral side was asymmetrical in ICM-MR, whereas it was symmetrical in DCM-MR. RT3DE is a helpful tool for differentiating the geometry of the mitral apparatus between these 2 different types of functional mitral regurgitation.

Evaluation Studies↗

Sleep-wake differences in scaling behavior of the human heartbeat: analysis of terrestrial and long-term space flight data

We compare scaling properties of the cardiac dynamics during sleep and wake periods for healthy individuals, cosmonauts during orbital flight, and subjects with severe heart disease. For all three groups, we find a greater degree of anticorrelation in the heartbeat fluctuations during sleep compared to wake periods. The sleep-wake difference in the scaling exponents for the three groups is comparable to the difference between healthy and diseased individuals. The observed scaling differences are not accounted for simply by different levels of activity, but appear related to intrinsic changes in the neuroautonomic control of the heartbeat.

Flight Experiment↗

Cardiovascular responses to postural changes: differences with age for women and men

The cardiovascular responses to postural change, and how they are affected by aging, are inadequately described in women. Therefore, the authors examined the influence of age and sex on the responses of blood pressure, cardiac output, heart rate, and other variables to change in posture. Measurements were made after 10 minutes each in the supine, seated, and standing positions in 22 men and 25 women who ranged in age from 21 to 59 years. Several variables differed, both by sex and by age, when subjects were supine. On rising, subjects' diastolic and mean arterial pressures, heart rate, total peripheral resistance (TPR), and thoracic impedance increased; cardiac output, stroke volume, and mean stroke ejection rate decreased; and changes in all variables, except heart rate, were greater from supine to sitting than sitting to standing. The increase in heart rate was greater in the younger subjects, and increases in TPR and thoracic impedance were greater in the older subjects. Stroke volume decreased less, and TPR and thoracic impedance increased more, in the women than in the men. The increase in TPR was particularly pronounced in the older women. These studies show that the cardiovascular responses to standing differ, in some respects, between the sexes and with age. The authors suggest that the sex differences are, in part, related to greater decrease of thoracic blood volume with standing in women than in men, and that the age differences result, in part, from decreased responsiveness of the high-pressure baroreceptor system.

Posture/physiology↗

Gender differences in endocrine responses to posture and 7 days of -6 degrees head-down bed rest

Endocrine regulation of fluids and electrolytes during 7 days of -6 degrees head-down bed rest (HDBR) was compared in male (n = 8) and, for the first time, female (n = 8) volunteers. The subjects' responses to quiet standing for 2 h before and after HDBR were also tested. In both sexes, diuresis and natriuresis were evident during the first 2-3 days of HDBR, resulting in a marked increase in the urinary Na(+)-to-K+ ratio and significant Na+ retention on re-ambulation. After the 1st day of HDBR, plasma renin activity (PRA) was increased relative to aldosterone (Aldo), plasma volume was decreased, and the renal response to Aldo appeared to be appropriate. Circulating levels of arginine vasopressin, cortisol, and ACTH were unchanged during HDBR. Plasma testosterone decreased slightly on day 2 of HDBR in males. The ratio of early morning ACTH to cortisol was lower in females than in males because ACTH was lower in females. Urinary cortisol increased and remained elevated throughout the HDBR in males only. There were no gender differences in the responses to 7 days of HDBR, except those in the pituitary-adrenal system; those differences appeared unrelated to the postural change. The provocative cardiovascular test of quiet standing before and after HDBR revealed both sex differences and effects of HDBR. There were significant sex differences in cardiovascular responses to standing before and after HDBR. Females had greater PRA and Aldo responses to standing before HDBR and larger Aldo responses to standing after HDBR than males.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Number 14-10↗

Stomatal conductance of lettuce grown under or exposed to different light qualities

BACKGROUND AND AIMS: The objective of this research was to examine the effects of differences in light spectrum on the stomatal conductance (Gs) and dry matter production of lettuce plants grown under a day/night cycle with different spectra, and also the effects on Gs of short-term exposure to different spectra. METHODS: Lettuce (Lactuca sativa) plants were grown with 6 h dark and 18 h light under four different spectra, red-blue (RB), red-blue-green (RBG), green (GF) and white (CWF), and Gs and plant growth were measured. KEY RESULTS AND CONCLUSIONS: Conductance of plants grown for 23 d under CWF rose rapidly on illumination to a maximum in the middle of the light period, then decreased again before the dark period when it was minimal. However, the maximum was smaller in plants grown under RB, RGB and GF. This demonstrates that spectral quality during growth affects the diurnal pattern of stomatal conductance. Although Gs was smaller in plants grown under RGB than CWF, dry mass accumulation was greater, suggesting that Gs did not limit carbon assimilation under these spectral conditions. Temporarily changing the spectral quality of the plants grown for 23 d under CWF, affected stomatal responses reversibly, confirming studies on epidermal strips. This study provides new information showing that Gs is responsive to spectral quality during growth and, in the short-term, is not directly coupled to dry matter accumulation.

Light↗

Determination and Applications of Environmental Costs at Different Sized Airports: Aircraft Noise and Engine Emissions

With the increasing trend of charging for externalities and the aim of encouraging the sustainable development of the air transport industry, there is a need to evaluate the social costs of these undesirable side effects, mainly aircraft noise and engine emissions, for different airports. The aircraft noise and engine emissions social costs are calculated in monetary terms for five different airports, ranging from hub airports to small regional airports. The number of residences within different levels of airport noise contours and the aircraft noise classifications are the main determinants for accessing aircraft noise social costs. Whist, based on the damages of different engine pollutants on the human health, vegetation, materials, aquatic ecosystem and climate, the aircraft engine emissions social costs vary from engine types to aircraft categories. The results indicate that the relationship appears to be curvilinear between environmental costs and the traffic volume of an airport. The results and methodology of environmental cost calculation could input for to the proposed European wide harmonized noise charges as well as the social cost benefit analysis of airports.

Lu, Cherie↗

Three Dimensional Constraint Effects on the Estimated (Delta)CTOD during the Numerical Simulation of Different Fatigue Threshold Testing Techniques

Variation in constraint through the thickness of a specimen effects the cyclic crack-tip-opening displacement (DELTA CTOD). DELTA CTOD is a valuable measure of crack growth behavior, indicating closure development, constraint variations and load history effects. Fatigue loading with a continual load reduction was used to simulate the load history associated with fatigue crack growth threshold measurements. The constraint effect on the estimated DELTA CTOD is studied by carrying out three-dimensional elastic-plastic finite element simulations. The analysis involves numerical simulation of different standard fatigue threshold test schemes to determine how each test scheme affects DELTA CTOD. The American Society for Testing and Materials (ASTM) prescribes standard load reduction procedures for threshold testing using either the constant stress ratio (R) or constant maximum stress intensity (K(sub max)) methods. Different specimen types defined in the standard, namely the compact tension, C(T), and middle cracked tension, M(T), specimens were used in this simulation. The threshold simulations were conducted with different initial K(sub max) values to study its effect on estimated DELTA CTOD. During each simulation, the DELTA CTOD was estimated at every load increment during the load reduction procedure. Previous numerical simulation results indicate that the constant R load reduction method generates a plastic wake resulting in remote crack closure during unloading. Upon reloading, this remote contact location was observed to remain in contact well after the crack tip was fully open. The final region to open is located at the point at which the load reduction was initiated and at the free surface of the specimen. However, simulations carried out using the constant Kmax load reduction procedure did not indicate remote crack closure. Previous analysis results using various starting K(sub max) values and different load reduction rates have indicated DELTA CTOD is independent of specimen size. A study of the effect of specimen thickness and geometry on the measured DELTA CTOD for various load reduction procedures and its implication in the estimation of fatigue crack growth threshold values is discussed.

Seshadri, Banavara R.↗

Atlantic to Mediterranean Sea Level Difference Driven by Winds near Gibraltar Strait

Observations and numerical simulations show that winds near Gibraltar Strait cause an Atlantic Ocean to Mediterranean Sea sea level difference of 20 cm peak to peak with a 3-cm standard deviation for periods of days to years. Theoretical arguments and numerical experiments establish that this wind-driven sea level difference is caused in part by storm surges due to alongshore winds near the North African coastline on the Atlantic side of Gibraltar. The fraction of the Moroccan coastal current offshore of the 284-m isobath is deflected across Gibraltar Strait, west of Camarinal Sill, resulting in a geostrophic surface pressure gradient that contributes to a sea level difference at the stationary limit. The sea level difference is also caused in part by the along-strait wind setup, with a contribution proportional to the along-strait wind stress and to the length of Gibraltar Strait and adjoining regions and inversely proportional to its depth.

atmospheric pressure fluctuations↗

Nanoscale Subsurface Imaging of Nanocomposites via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. The method employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope engages the sample top surface. The cantilever is driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave at the sample surface generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create amplitude and phase-generated images of nanoscale near-surface and subsurface features. RDF-AFUM phase images of LaRC-CP2 polyimide polymer containing embedded nanostructures are presented. A RDF-AFUM micrograph of a 12.7 micrometer thick film of LaRC-CP2 containing a monolayer of gold nanoparticles embedded 7 micrometers below the specimen surface reveals the occurrence of contiguous amorphous and crystalline phases within the bulk of the polymer and a preferential growth of the crystalline phase in the vicinity of the gold nanoparticles. A RDF-AFUM micrograph of LaRC-CP2 film containing randomly dispersed carbon nanotubes reveals the growth of an interphase region at certain nanotube-polymer interfaces.

Cantrell, Sean A.↗

Gender Differences in Bed Rest: Preliminary Analysis of Vascular Function

Orthostatic intolerance is a recognized consequence of spaceflight. Numerous studies have shown that women are more susceptible to orthostatic intolerance following spaceflight as well as bed rest, the most commonly used ground-based analog for spaceflight. One of the possible mechanisms proposed to account for this is a difference in vascular responsiveness between genders. We hypothesized that women and men would have differing vascular responses to 90 days of 6-degree head down tilt bed rest. Additionally, we hypothesized that vessels in the upper and lower body would respond differently, as has been shown in the animal literature. Thirteen subjects were placed in bedrest for 90 days (8 men, 5 women) at the Flight Analogs Unit, UTMB. Direct arterial and venous measurements were made with ultrasound to evaluate changes in vascular structure and function. Arterial function was assessed, in the arm and leg, during a reactive hyperemia protocol and during sublingual nitroglycerin administration to gauge the contributions of endothelial dependent and independent dilator function respectively. Venous function was assessed in dorsal hand and foot veins during the administration of pharmaceuticals to assess constrictor and dilator function. Both gender and day effects are seen in arterial dilator function to reactive hyperemia, but none are seen with nitroglycerin. There are also differences in the wall thickness in the arm vs the leg during bed rest, which return toward pre-bed rest levels by day 90. More subjects are required, especially females as there is not sufficient power to properly analyze venous function. Day 90 data are most underpowered.

Platts, Steven H.↗

16 Weeks of Training with the International Space Station Advanced Resistive Exercise Device (aRED) Is not Different than Training with Free Weights

The advanced Resistive Exercise Device (aRED) is a resistive exercise system designed to maintain muscle mass and strength in microgravity by simulating free weight (FW) exercise. aRED utilizes vacuum cylinders and inertial flywheels to replicate the constant mass and inertial components, respectively, of FW exercise in normal gravity. PURPOSE: To compare the effectiveness of aRED and FW resistive exercise training in ambulatory subjects. METHODS: Untrained subjects were assigned to two groups, FW (6 males, 3 females) and aRED (8 males, 3 females), and performed squat (SQ), heel raise (HR), and deadlift (DL) exercises 3 d wk-1 for 16 wks. SQ, HR and DL strength (1RM) were measured using FW hardware pre-, mid- and post-training. Subjects participated in a periodized training protocol with the exercise prescription based on a percentage of 1RM. Thigh and lower leg muscle volume were assessed using Magnetic Resonance Imaging (MRI), and leg (LLM) and total body lean mass (BLM) were measured using Dual Energy X-ray Absorptiometry (DXA) pre- and post-training. RESULTS: SQ 1RM increased in both FW (48.9+/-6.1%) and aRED (31.2+/-3.8%) groups, and there was a greater training response in FW compared with aRED (p=0.01). HR and DL 1RM increased in FW (HR: 12.3+/-2.4%, DL: 23.3+/-4.4%) and aRED (HR: 18.0+/-1.6%, DL: 23.2+'-2.8%), but there were no differences between groups. Thigh muscle volume was greater following training in both groups (FW: 9.8+/-0.9%, aRED: 7.1+/-1.2%) but lower leg muscle volume increased only in the FW group (3.0+/-1.1%). Lean tissue mass increased in both FW (LLM: 3.9+/-1.1%, BLM: 2.5+/-0.7%) and aRED (LLM: 4.8+/-0.7%, BLM: 2.6 0.7%). There were no between group differences in muscle volume or lean mass in response to training. CONCLUSIONS: In general, the increase in muscle strength, muscle volume, and lean tissue mass when training with aRED was not different than when using the same training protocol with FW. The smaller increase in SQ 1RM in the aRED group may be the result of undersizing the aRED flywheels which were intended to mimic the inertial component of the SQ movement when performing FW exercises. However, the biomechanical differences observed in body position during the performance of the aRED SQ, which may have affected training and testing, cannot be excluded as a factor that may have affected SQ 1RM results. PRACTICAL APPLICATIONS: Improvements in muscle strength, muscle volume and lean mass similar to FW exercise training may be elicited using an alternative source of resistance during exercise training. The acceleration of a mass during resistive exercise may result in greater muscle tension when changing the direction of movement resulting in enhanced strength gains. Therefore, to maximize the benefits of resistive exercise, the inertial components of FW exercise should be considered during exercise selection and hardware design. ACKNOWLEDGEMENT: This investigation was supported by NASA-JSC s Exercise Countermeasures Project.

Loehr, J. A.↗

Resonant difference-frequency atomic force ultrasonic microscope

A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

Cantrell, John H.↗

Assessment of Cumulative Trauma Disorder (CTD) Risk for 3 Different Tasks Constructing and Repairing Multi-Layer Insulation (MLI) Blankets, Preparing the Dough for a Pizza, and Operating the Becton-Dickinson FACSAria Flow Cytometer

The Cumulative Trauma Disorder (CTD) risks for three different tasks using McCauley-Bell and Badiru's (1993) formula based on task, personal, and organizational factors were examined. For the Multi-Layer Insulation (MLI) blanket task, the results showed that the task, personal, and organizational risks were at about the same level. The personal risk factors for this task were evaluated using a hypothetical female employee age 52. For the pizza dough task, it was shown that the organizational risk was particularly high, with task related factors also at quite dangerous levels. On the other hand, there was a very low level of personal risk factors, based on a female age 17. The flow cytometer task was assessed with three different participants, a11 of whom had quite disparate levels of personal risk, which slightly affected the overall CTD risk. This reveals how individual difference variables certainly need to be considered. The task and organizational risks for this task were rated at about the same moderate level. The overall CTD risk averaged across the three participants was .335, indicating some risk. Compruing across the tasks revealed that the pizza dough task created the greatest overall CTD risk by far (.568), with the MLI (.325) and flow cytometer task (.335) having some risk associated with them. Future research should look into different tasks for more of a comparison

Gentzler, Marc↗

High-Order Entropy Stable Finite Difference Schemes for Nonlinear Conservation Laws: Finite Domains

Developing stable and robust high-order finite difference schemes requires mathematical formalism and appropriate methods of analysis. In this work, nonlinear entropy stability is used to derive provably stable high-order finite difference methods with formal boundary closures for conservation laws. Particular emphasis is placed on the entropy stability of the compressible Navier-Stokes equations. A newly derived entropy stable weighted essentially non-oscillatory finite difference method is used to simulate problems with shocks and a conservative, entropy stable, narrow-stencil finite difference approach is used to approximate viscous terms.

Fisher, Travis C.↗

Longitudinal Differences of Ionospheric Vertical Density Distribution and Equatorial Electrodynamics

Accurate estimation of global vertical distribution of ionospheric and plasmaspheric density as a function of local time, season, and magnetic activity is required to improve the operation of space-based navigation and communication systems. The vertical density distribution, especially at low and equatorial latitudes, is governed by the equatorial electrodynamics that produces a vertical driving force. The vertical structure of the equatorial density distribution can be observed by using tomographic reconstruction techniques on ground-based global positioning system (GPS) total electron content (TEC). Similarly, the vertical drift, which is one of the driving mechanisms that govern equatorial electrodynamics and strongly affect the structure and dynamics of the ionosphere in the low/midlatitude region, can be estimated using ground magnetometer observations. We present tomographically reconstructed density distribution and the corresponding vertical drifts at two different longitudes: the East African and west South American sectors. Chains of GPS stations in the east African and west South American longitudinal sectors, covering the equatorial anomaly region of meridian approx. 37 deg and 290 deg E, respectively, are used to reconstruct the vertical density distribution. Similarly, magnetometer sites of African Meridian B-field Education and Research (AMBER) and INTERMAGNET for the east African sector and South American Meridional B-field Array (SAMBA) and Low Latitude Ionospheric Sensor Network (LISN) are used to estimate the vertical drift velocity at two distinct longitudes. The comparison between the reconstructed and Jicamarca Incoherent Scatter Radar (ISR) measured density profiles shows excellent agreement, demonstrating the usefulness of tomographic reconstruction technique in providing the vertical density distribution at different longitudes. Similarly, the comparison between magnetometer estimated vertical drift and other independent drift observation, such as from VEFI onboard Communication/Navigation Outage Forecasting System (C/NOFS) satellite and JULIA radar, is equally promising. The observations at different longitudes suggest that the vertical drift velocities and the vertical density distribution have significant longitudinal differences; especially the equatorial anomaly peaks expand to higher latitudes more in American sector than the African sector, indicating that the vertical drift in the American sector is stronger than the African sector.

total electron content↗

The Impact of Dielectric Constant Model and Surface Reference on Differences Between SMOS and Aquarius Sea Surface Salinity

Two ongoing space missions share the scientific objective of mapping the global Sea Surface Salinity (SSS), yet their observations show significant discrepancies. ESA's Soil Moisture and Ocean Salinity (SMOS) and NASA's Aquarius use L-band (1.4 GHz) radiometers to measure emission from the sea surface and retrieve SSS. Significant differences in SSS retrieved by both sensors are observed, with SMOS SSS being generally lower than Aquarius SSS, except for very cold waters where SMOS SSS is the highest overall. Figure 1 is an example of the difference between the SSS retrieved by SMOS and Aquarius averaged over one month and 1 degree in longitude and latitude. Differences are mostly between -1 psu and +1 psu (psu, practical salinity unit), with a significant regional and latitudinal dependence. We investigate the impact of the vicarious calibration and retrieval algorithm used by both mission on these differences.

SMOS↗