Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference in differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Relating SMMR 37 GHz polarization difference to precipitation and atmospheric carbon dioxide concentration - A reappraisal

The relations of Scanning Multi-channel Microwave Radiometer (SMMR) 37 GHz polarization difference to precipitation and atmospheric carbon dioxide (CO2) concentrations are reviewed. Annual precipitation data, a surrogate for green leaf vegetation density, are compared with the coincident SMMR 37 GHz polarization difference from arid and semi-arid West Africa for 1982-85. The SMMR 37 GHz polarization difference was found to be poorly correlated with precipitation in arid and semi-arid zones, contrary to previous reports. Coincident SMMR 37 GHz polarization difference and atmospheric CO2 concentration data from July 1981 to June 1983 are also reviewed. Previously suggested relations of the SMMR 37 GHz polarization difference to atmospheric CO2 concentrations were found to be heavily biased by winter conditions in the Northern Hemisphere. The use of the SMMR 37 GHz polarization difference for determining green leaf vegetation density, net primary production, atmospheric CO2 draw-down and related processes is questioned.

Tucker, C. J.↗

Lower Stratospheric Temperature Differences Between Meteorological Analyses in two cold Arctic Winters and their Impact on Polar Processing Studies

A quantitative intercomparison of six meteorological analyses is presented for the cold 1999-2000 and 1995-1996 Arctic winters. The impacts of using different analyzed temperatures in calculations of polar stratospheric cloud (PSC) formation potential, and of different winds in idealized trajectory-based temperature histories, are substantial. The area with temperatures below a PSC formation threshold commonly varies by approximately 25% among the analyses, with differences of over 50% at some times/locations. Freie University at Berlin analyses are often colder than others at T is less than or approximately 205 K. Biases between analyses vary from year to year; in January 2000. U.K. Met Office analyses were coldest and National Centers for Environmental Prediction (NCEP) analyses warmest. while NCEP analyses were usually coldest in 1995-1996 and Met Office or NCEP[National Center for Atmospheric Research Reanalysis (REAN) warmest. European Centre for Medium Range Weather Forecasting (ECMWF) temperatures agreed better with other analyses in 1999-2000, after improvements in the assimilation model. than in 1995-1996. Case-studies of temperature histories show substantial differences using Met Office, NCEP, REAN and NASA Data Assimilation Office (DAO) analyses. In January 2000 (when a large cold region was centered in the polar vortex), qualitatively similar results were obtained for all analyses. However, in February 2000 (a much warmer period) and in January and February 1996 (comparably cold to January 2000 but with large cold regions near the polar vortex edge), distributions of "potential PSC lifetimes" and total time spent below a PSC formation threshold varied significantly among the analyses. Largest peaks in "PSC lifetime" distributions in January 2000 were at 4-6 and 11-14 days. while in the 1996 periods, they were at 1-3 days. Thus different meteorological conditions in comparably cold winters had a large impact on expectations for PSC formation and on the discrepancies between different meteorological analyses. Met Office. NCEP, REAN, ECMWF and DAO analyses are commonly used for trajectory calculations and in chemical transport models; the choice of which analysis to use can strongly influence the results of such studies.

Manney, Gloria L.↗

Alternative Perspectives on Risk: Individual Differences in Problem Structuring

Team decision making involves contributions of multiple players toward a common goal. While much has been written about the importance of developing shared mental models in order for teams to work together effectively, little has been done to determine the value of alternative perspectives on problem solving and decision making. Early studies of expertise contrasted experts with novices and noted that the two groups differ in the way they structure problems and in their selection of information as salient. Little attention has been given to differences among experts who differ in their specializations. A series of experiments was conducted to determine: (1) what dimensions of flight-related problem situations pilots judge to be most important when making flight-relevant decisions; and (2) whether pilots in different crew positions differ in the way they interpret problems relating to flight decisions. A sorting task was used to identify underlying dimensions judged as salient to individual pilots. Captains, first officers, and flight engineers from two major carriers participated in the study. Twenty-two flight scenarios were developed based on ASRS reports. Pilots were required to make judgments about how they would respond in each case and to sort the scenarios on the basis of similarity of decision factors. They were also asked to provide a verbal label that described each of their sorted categories. A second study required a different group of pilots (also captains, first officers and flight engineers) to sort on predetermined bases.

Orasanu, Judith↗

Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques

The ionization pathways were determined for sets of isomeric non-polar hydrocarbons (structural isomers, cis/trans isomers) using ion mobility spectrometry and mass spectrometry with different techniques of atmospheric pressure chemical ionization to assess the influence of structural features on ion formation. Depending on the structural features, different ions were observed using mass spectrometry. Unsaturated hydrocarbons formed mostly [M - 1]+ and [(M - 1)2H]+ ions while mainly [M - 3]+ and [(M - 3)H2O]+ ions were found for saturated cis/trans isomers using photoionization and 63Ni ionization. These ionization methods and corona discharge ionization were used for ion mobility measurements of these compounds. Different ions were detected for compounds with different structural features. 63Ni ionization and photoionization provide comparable ions for every set of isomers. The product ions formed can be clearly attributed to the structures identified. However, differences in relative abundance of product ions were found. Although corona discharge ionization permits the most sensitive detection of non-polar hydrocarbons, the spectra detected are complex and differ from those obtained with 63Ni ionization and photoionization. c. 2002 American Society for Mass Spectrometry.

Non-NASA Center↗

Team Performance and Error Management in Chinese and American Simulated Flight Crews: The Role of Cultural and Individual Differences

This report describes results of a study conducted for NASA-Langley Research Center. This study is part of a program of research conducted for NASA-LARC that has focused on identifying the influence of national culture on the performance of flight crews. We first reviewed the literature devoted to models of teamwork and team performance, crew resource management, error management, and cross-cultural psychology. Davis (1999) reported the results of this review and presented a model that depicted how national culture could influence teamwork and performance in flight crews. The second study in this research program examined accident investigations of foreign airlines in the United States conducted by the National Transportation Safety Board (NTSB). The ability of cross-cultural values to explain national differences in flight outcomes was examined. Cultural values were found to covary in a predicted way with national differences, but the absence of necessary data in the NTSB reports and limitations in the research method that was used prevented a clear understanding of the causal impact of cultural values. Moreover, individual differences such as personality traits were not examined in this study. Davis and Kuang (2001) report results of this second study. The research summarized in the current report extends this previous research by directly assessing cultural and individual differences among students from the United States and China who were trained to fly in a flight simulator using desktop computer workstations. The research design used in this study allowed delineation of the impact of national origin, cultural values, personality traits, cognitive style, shared mental model, and task workload on teamwork, error management and flight outcomes. We briefly review the literature that documents the importance of teamwork and error management and its impact on flight crew performance. We next examine teamwork and crew resource management training designed to improve teamwork. This is followed by discussion of the potential influence of national culture on teamwork and crew resource management. We then examine the influence of other individual and team differences, such as personality traits, cognitive style, shared mental model, and task workload. We provide a heuristic model that depicts the influence of national culture and individual differences on teamwork, error management and flight outcomes. The results demonstrate the usefulness of the model for future research.

Davis, Donald D.↗

Understanding Differences in Upper Stratospheric Ozone Response to Changes in Chlorine and Temperature as Computed Using CCMVal Models

Projections of future ozone levels are made using models that couple a general circulation model with a representation of atmospheric photochemical processes, allowing interactions among photochemical processes, radiation, and dynamics. Such models are known as chemistry and climate models (CCMs). Although developed from common principles and subject to the same boundary conditions, simulated ozone time series vary for projections of changes in ozone depleting substances (ODSs) and greenhouse gases. In the upper stratosphere photochemical processes control ozone level, and ozone increases as ODSs decrease and temperature decreases due to greenhouse gas increase. Simulations agree broadly but there are quantitative differences in the sensitivity of ozone to chlorine and to temperature. We obtain insight into these differences in sensitivity by examining the relationship between the upper stratosphere annual cycle of ozone and temperature as produced by a suite of models. All simulations conform to expectation in that ozone is less sensitive to temperature when chlorine levels are highest because chlorine catalyzed loss is nearly independent of temperature. Differences in sensitivity are traced to differences in simulated temperature, ozone and reactive nitrogen when chlorine levels are close to background. This work shows that differences in the importance of specific processes underlie differences in simulated sensitivity of ozone to composition change. This suggests a) the multi-model mean is not a best estimate of the sensitivity of upper ozone to changes in ODSs and temperature; b) the spread of values is not an appropriate measure of uncertainty.

Douglass, A. R.↗

Quantifying the Causes of Differences in Tropospheric OH Within Global Models

The hydroxyl radical (OH) is the primary daytime oxidant in the troposphere and provides the main loss mechanism for many pollutants and greenhouse gases, including methane (CH4). Global mean tropospheric OH differs by as much as 80% among various global models, for reasons that are not well understood. We use neural networks (NNs), trained using archived output from eight chemical transport models (CTMs) that participated in the Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols and Transport Model Intercomparison Project (POLMIP), to quantify the factors responsible for differences in tropospheric OH and resulting CH4 lifetime (Tau CH4) between these models. Annual average Tau CH4, for loss by OH only, ranges from 8.0 to 11.6 years for the eight POLMIP CTMs. The factors driving these differences were quantified by inputting 3-D chemical fields from one CTM into the trained NN of another CTM. Across all CTMs, the largest mean differences in Tau CH4 (Delta Tau CH4) result from variations in chemical mechanisms (Delta Tau CH4 = 0.46 years), the photolysis frequency (J) of O3 yields O(D-1) (0.31 years), local O3 (0.30 years), and CO (0.23 years). The Delta Tau CH4 due to CTM differences in NO(x) (NO + NO2) is relatively low (0.17 years), although large regional variation in OH between the CTMs is attributed to NO(x). Differences in isoprene and J(NO2) have negligible overall effect on globally averaged tropospheric OH, although the extent of OH variations due to each factor depends on the model being examined. This study demonstrates that NNs can serve as a useful tool for quantifying why tropospheric OH varies between global models, provided that essential chemical fields are archived.

Surface Measurements and Models↗

Suomi NPP VIIRS DNB and RSB M Bands Detector-To-Detector and HAM Side Calibration Differences Assessment Using a Homogenous Ground Target

Near-nadir observations of the Libya 4 site from the S-NPP VIIRS Day-Night Band (DNB) and Moderate resolution Bands (M bands) are used to assess the detector calibration stability and half-angle mirror (HAM) side differences. Almost seven years of Sensor Data Records products are extracted from the Libya 4 site center over an area of 32×32 pixels. The mean values of the radiance from individual detectors per HAM side are computed separately. The comparison of the normalized radiance between detectors indicates that the detector calibration differences are wavelength dependent and the differences have been slowly increasing with time for short wavelength bands, especially for M1-M4. The maximum annual average differences between DNB detectors are 0.77% in 2017 at HAM-A. For the M bands, the maximum detector differences in 2017 are 1.7% for M1, 1.8% for M2, 1.3% for M3, 1.2% for M4, 0.67% for M5, 0.75% for M7, 0.57% for M8, 13% for M9, 0.63% for M10, and 0.66% for M11. The average HAM side A to B difference in 2017 are 0.00% for DNB, 0.22% for M1, 0.17% for M2, 0.15% for M3, 0.09% for M4, -0.07% for M5, 0.02% for M7, 0.01% for M8, 1.4% for M9, 0.01% for M10, and 0.03% for M11. Results for M6 are not available due to the signal saturation and M9 results are not accurate because of the low reflectance from the desert site and the strong atmospheric absorption in this channel. The results in this study help scientists better understand each detector’s performance and HAM side characteristics. Additionally, they provide evidence and motivation for future VIIRS calibration improvements.

SNPP VIIRS↗

Differences in Tropical High Clouds Among Reanalyses: Origins and Radiative Impacts

We examine differences among reanalysis highcloud products in the tropics, assess the impacts of these differences on radiation budgets at the top of the atmosphere and within the tropical upper troposphere and lower stratosphere (UTLS), and discuss their possible origins in the context of the reanalysis models. We focus on the ERA5 (fifthgeneration European Centre for Medium-range Weather Forecasts – ECMWF – reanalysis), ERA-Interim (ECMWF Interim Reanalysis), JRA-55 (Japanese 55-year Reanalysis), MERRA-2 (Modern-Era Retrospective Analysis for Research and Applications, Version 2), and CFSR/CFSv2 (Climate Forecast System Reanalysis/Climate Forecast System Version 2) reanalyses. As a general rule, JRA-55 produces the smallest tropical high-cloud fractions and cloud water contents among the reanalyses, while MERRA-2 produces the largest. Accordingly, long-wave cloud radiative effects are relatively weak in JRA-55 and relatively strong in MERRA-2. Only MERRA-2 and ERA5 among the reanalyses produce tropical-mean values of outgoing long-wave radiation (OLR) close to those observed, but ERA5 tends to underestimate cloud effects, while MERRA-2 tends to overestimate variability. ERA5 also produces distributions of longwave, short-wave, and total cloud radiative effects at the top of the atmosphere that are very consistent with those observed. The other reanalyses all exhibit substantial biases in at least one of these metrics, although compensation between the long-wave and short-wave effects helps to constrain biases in the total cloud radiative effect for most reanalyses. The vertical distribution of cloud water content emerges as a key difference between ERA-Interim and other reanalyses. Whereas ERA-Interim shows a monotonic decrease of cloud water content with increasing height, the other reanalyses all produce distinct anvil layers. The latter is in better agreement with observations and yields very different profiles of radiative heating in the UTLS. For example, whereas the altitude of the level of zero net radiative heating tends to be lower in convective regions than in the rest of the tropics in ERAInterim, the opposite is true for the other four reanalyses. Differences in cloud water content also help to explain systematic differences in radiative heating in the tropical lower stratosphere among the reanalyses. We discuss several ways in which aspects of the cloud and convection schemes impact the tropical environment. Discrepancies in the vertical profiles of temperature and specific humidity in convective regions are particularly noteworthy, as these variables are directly constrained by data assimilation, are widely used, and feed back to convective behaviour through their relationships with thermodynamic stability.

High Clouds↗

Plausible Biological Mechanisms Underlying Sex Differences in Radiation-Induced Lung Cancer Risk

Some epidemiological studies suggest that women are at greater risk for radiation-induced lung cancer than men, but this observation is not consistent across all studies. A scientific committee formed by the National Council on Radiation Protection and Measurement evaluated evidence for a sex difference in lung cancer risk from radiation exposuresby reviewing animal studies and assessing the biological plausibility that such a difference might exist. The committee identified four mechanisms that could potentially result in greater radiogenic lung cancer risks for women. The first of these is that radiation exposure increases the relative risk for a molecular subtype of spontaneous lung cancer that occurs predominantly in women. The second is that is that sex chromosome or gene expression differences between men and women places women at greater risk. The third is that hormonal differences between men and women, particularly for estrogen levels, puts women at greater risk. The fourth mechanism is that sex differences in immune system function underlie a sex difference in radiation associated lung cancer risk.None of these mechanisms hasyet been proven to play a role in radiogenic lung cancer risk.

radiation↗

Is the A-1 Pigment in Photosystem I Part of P700? A (P700+–P700) FTIR Difference Spectroscopy Study of A-1 Mutants

The involvement of the second pair of chlorophylls, termed A-1A and A-1B, in light-induced electron transfer in photosystem I (PSI) is currently debated. Asparagines at PsaA600 and PsaB582 are involved in coordinating the A-1B and A-1A pigments, respectively. Here we have mutated these asparagine residues to methionine in two single mutants and a double mutant in PSI from Synechocystis sp. PCC 6803, which we term NA600M, NB582M, and NA600M/NB582M mutants. (P700+–P700) FTIR difference spectra (DS) at 293 K were obtained for the wild-type and the three mutant PSI samples. The wild-type and mutant FTIR DS differ considerably. This difference indicates that the observed changes in the (P700+–P700) FTIR DS cannot be due to only the PA and PB pigments of P700. Comparison of the wild-type and mutant FTIR DS allows the assignment of different features to both A-1 pigments in the FTIR DS for wild-type PSI and assesses how these features shift upon cation formation and upon mutation. While the exact role the A-1 pigments play in the species we call P700 is unclear, we demonstrate that the vibrational modes of the A-1A and A-1B pigments are modified upon P700+ formation. Previously, we showed that the A-1 pigments contribute to P700 in green algae. In this manuscript, we demonstrate that this is also the case in cyanobacterial PSI. The nature of the mutation-induced changes in algal and cyanobacterial PSI is similar and can be considered within the same framework, suggesting a universality in the nature of P700 in different photosynthetic organisms.

59 BASIC BIOLOGICAL SCIENCES↗

A Finite Difference Analysis of the Effect of Graphene Additions on the Electrical Conductivity of Polycrystalline Copper

A finite-difference method was used to explore the effect of graphene on the bulk electrical conductivity of copper-graphene composites. In this capacity, grain orientation information from pure copper and copper-graphene composites were used to generate synthetic 3D microstructures. The electrical conductivity of these microstructures were calculated using the finite difference method assuming different average grain sizes. From these calculations, we demonstrate that when high-conductivity grain boundaries are present within the microstructure arising from the presence of graphene, an increase in the bulk electrical conductivity is observed. On the other hand, the difference in textures between copper and copper-graphene composites may not account for a significant difference in bulk electrical conductivity. In comparison, the copper grain size has a considerably larger effect on electrical conductivity as previously anticipated. This is one of the first demonstrations of a physical basis for enhanced conductivity composites and presents pathways for further investigations on the effects of composite microstructural features, material interfaces and graphene content on electrical performance.

Frazier, William E.↗

The Influence of Residual Stress on Fatigue Crack Growth Rates in Stainless Steel Processed by Different Additive Manufacturing Methods

The properties and microstructure of Type 304L stainless steel produced by two additive manufacturing (AM) methods—directed energy deposition (DED) and powder bed fusion (PBF)—are evaluated and compared. Localized heating and steep temperature gradients of AM processes lead to significant residual stress and distinctive microstructures, which may be process-specific and influence mechanical behavior. Test data show that materials produced by DED and PDF have small differences in tensile strengths but clear differences in residual stress and microstructural features. Measured fatigue crack growth rates (FCGRs) for cracks propagating parallel to and perpendicular to the build directions differ between the two AM materials. To separate the influences of residual stress and microstructure, K-control test procedures with decreasing and constant stress intensity factor ranges are used to measure FCGRs in the near-threshold regime (crack growth rates ≤ 1 × 10 −8 m/cycle). Residual stress is quantified by the residual stress intensity factor, K res , measured by the online crack compliance method. Correcting the FCGR data for differences in K res brings results for specimens of the two AM materials into agreement with each other and with results for wrought specimens, when the latter are corrected for crack closure. Differences in microstructure and tensile strength have an insignificant influence on FCGRs in these tests.

additive manufacturing↗

Designing a repository in domal salt: The influence of design variants in different modelling environments

To understand the long-term environmental impact of disposing radioactive waste of in a deep geological repository and to optimise its design, performance assessments are used. In this study, four teams (COVRA, GRS, Quintessa, and DOE) modified the previously developed generic repository of DECOVALEX task F2 to identify commonalities and differences between the teams for specific changes in repository design. The teams tested six design modifications: (1) Replacing concrete abutments with run-of-mine salt; (2) Replacing the salt seal with a concrete abutment and using run-of-mine salt instead for the two concrete abutments in each drift seal; (3) Halving the size of the infrastructure area; (4) Using run-of-mine salt instead of gravel for backfilling the infrastructure area; (5) Disposal of spent nuclear fuel without the POLLUX-10 containers (6); Lower initial saturation of the spent nuclear fuel and vitrified waste disposal drifts. Despite different modelling strategies used, models agreed that a smaller infrastructure area has a limited effect on radionuclide transport. Responses to the absence of the two concrete abutments in each seal, the use of single large concrete abutments (200 m each), or the use of run-of-mine salt in the infrastructure area differ between teams due to differing modelling assumptions. Based on these results, the estimated efficacy of containment depends strongly on the model assumptions of each team. More specifically, it appears to depend on the compaction model used and therefore on the backfill material used in different areas of the repository. However, the drift seal appears to be a critical design element in all models, effectively limiting radionuclide transport by hydrologically disconnecting sections of the repository. Additional beneficial design choices include the use of dry salt in disposal drifts to limit radionuclide transport and reducing the infrastructure area costs and minimizing host rock damage.

DECOVALEX↗

How to correct relative voxel scale factors for calculations of vector-difference Fourier maps in cryo-EM

The atomic coordinates derived from cryo-electron microscopy (cryo-EM) maps can be inaccurate when the voxel scaling factors are not properly calibrated. Here, we describe a method for correcting relative voxel scaling factors between pairs of cryo-EM maps for the same or similar structures that are expanded or contracted relative to each other. We find that the correction of scaling factors reduces the amplitude differences of Fourier-inverted structure factors from voxel-rescaled maps by up to 20–30%, as shown by two cryo-EM maps of the SARS-CoV-2 spike protein measured at pH 4.0 and pH 8.0. This allows for the calculation of the difference map after properly scaling, revealing differences between the two structures for individual amino acid residues. Unexpectedly, the analysis uncovers two previously overlooked differences of amino acid residues in structures and their local structural changes. Furthermore, we demonstrate the method as applied to two cryo-EM maps of monomeric apo-photosystem II from the cyanobacteria Synechocystis sp. PCC 6803 and Thermosynechococcus elongatus. The resulting difference maps reveal many changes in the peripheral transmembrane PsbX subunit between the two species.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of CMAS viscosity on the infiltration depth in thermal barrier coatings of different microstructures

Calcium magnesium aluminum silicate (CMAS) is one of the leading concerns for the gas turbine industry. The effects of CMAS viscosity and the coating microstructure on CMAS infiltration depth were explored by conducting a time dependent interaction study. Three CMAS compositions were used from literature, and their viscosities predicted through FactSage viscosity module were drastically different. The interaction was carried out on three different TBCs synthesized using the solution precursor plasma spray process (SPPS): two of the TBCs were made of yttrium aluminum garnet (YAG) having different microstructures that promote different modes of CMAS infiltration, and one TBC was made of gadolinium zirconate (GZO). All samples had stress relieving vertical cracks and different intensities of horizontally banded porosity, (inter pass boundaries IPBs). A concentration of 100 mg/cm 2 of CMAS was applied on the TBCs which were then subjected to a 5-minute interaction at 1300 °C. Samples were analyzed using scanning electron microscopy (SEM), electron dispersive X-ray spectroscopy (EDXS), and transmission electron microscopy (TEM). Low viscosity CMAS readily penetrated the TBCs while more viscous CMAS showed less penetration. The depth of CMAS infiltration depended on the coating microstructure. In the YAG with IPBs, the CMAS spread horizontally in the IPBs before infiltrating deeper, resulting in reduced infiltration depth compared to other samples in spite of having wider vertical cracks. TEM and EDXS analysis were performed to investigate the phases present in the CMAS-TBC interaction region in YAG. Two regions were chosen, the top TBC surface in direct contact with the sea of CMAS, and the region at the CMAS penetration ended within the coating. Finally, the results showed that no secondary phases like apatite were observed in YAG, thus it can be concluded that the arrest of CMAS happened solely because of CMAS viscosity and the short infiltration time.

36 MATERIALS SCIENCE↗

Understanding Differences in Water Adsorption Isotherms: Structural Variations, Force Fields, and Monte Carlo Simulation Approaches

Accurate prediction of water adsorption in micro- and mesoporous materials with hydrophobic pores is essential for the design and characterization of advanced adsorbent materials for separation and energy applications. Here, we assess the reproducibility and consistency of water adsorption isotherms in two microporous all-silica MFI zeolite structures (MFI-K and MFI-O) using two different zeolite force fields and three simulation approaches: grand canonical Monte Carlo (GCMC), Gibbs ensemble Monte Carlo (GEMC), and transition matrix Monte Carlo (TMMC). We demonstrate that consistent treatment of the bulk fluid phase in GCMC and TMMC simulations is critical for reconciling isotherms across methods, and we construct simulation-based equations of state for the TIP4P water model to enable rigorous fugacity-to-pressure conversions. Large shifts in the isotherms are observed for two zeolite force fields developed using different parametrization strategies, with the GCS force field representing implicitly a defect-containing all-silica zeolite, whereas the TraPPE-zeo force field accurately represents an essentially defect-free all-silica zeolite. While water in the van Koningsveld structure of MFI exhibits a first-order phase transition and condensation-like step for adsorption near room temperature, water in the Olson structure of MFI displays continuous adsorption, attributed to differences in the adsorption free energy landscapes. Structural analysis reveals that small geometric variations, particularly Si–O–Si bond angles near the strongest adsorption sites, lead to these substantial differences in adsorption behavior. Furthermore, our results highlight the sensitivity of simulated water adsorption isotherms in hydrophobic frameworks to seemingly small differences in the framework structures, force field parametrization, and simulation approaches.

36 MATERIALS SCIENCE↗

Interplay of physically different properties leading to challenges in separating lanthanide cations – an ab initio molecular dynamics and experimental study

Lanthanide elements have well-documented similarities in their chemical behavior, which make the valuable trivalent lanthanide cations (Ln 3+ ) particularly difficult to separate from each other in water. Here, we apply ab initio molecular dynamics simulations to compare the free energies (Δ G ads ) associated with the adsorption of lanthanide cations to silica surfaces at a pH condition where SiO – groups are present. The predicted Δ G ads for lutetium (Lu 3+ ) and europium (Eu 3+ ) are similar within statistical uncertainties; this is in qualitative agreement with our batch adsorption measurements on silica. This finding is remarkable because the two cations exhibit hydration free energies (Δ G hyd ) that differ by >2 eV, different hydration numbers, and different hydrolysis behavior far from silica surfaces. We observe that the similarity in Lu 3+ and Eu 3+ Δ G ads is the result of a delicate cancellation between the difference in Eu 3+ and Lu 3+ hydration (Δ G hyd ), and their difference in binding energies to silica. We propose that disrupting this cancellation at the two end points, either for adsorbed or completely desorbed lanthanides ( e.g. , via nanoconfinment or mixed solvents), will lead to effective Ln 3+ separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗