Search NASA⌕ Search

SEARCH · Search NASA

Results for “dimensional analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement of J / ψ and ψ ( 2 S ) Prompt Double-Differential Cross Sections in p p Collisions at s = 7 TeV

The double-differential cross sections of promptly produced J/ψ and ψ(2S) mesons are measured in pp collisions at √s=7 TeV, as a function of transverse momentum pT and absolute rapidity |y|. The analysis uses J/ψ and ψ(2S) dimuon samples collected by the CMS experiment, corresponding to integrated luminosities of 4.55 and 4.90 fb⁻¹, respectively. The results are based on a two-dimensional analysis of the dimuon invariant mass and decay length, and extend to p T =120 and 100 GeV for the J/ψ and ψ(2S), respectively, when integrated over the interval |y|<1.2. The ratio of the ψ(2S) to J/ψ cross sections is also reported for |y|<1.2, over the range 10 T <100 GeV. These are the highest p T values for which the cross sections and ratio have been measured.

Khachatryan, V.↗

Elucidating through-plane liquid water profile in a polymer electrolyte membrane fuel cell.

In this paper, a numerical model incorporating micro-porous layers (MPLs) is presented for simulating water transport within the gas diffusion layers (GDLs) and MPLs as well as across their interfaces in a polymer electrolyte membrane (PEM) fuel cell. One-dimensional analysis is conducted to investigate the impacts of MPL and GDL properties on the liquid-water profile across the anode GDL-MPL and cathode MPL-GDL regions. Furthermore, two-dimensional numerical simulations that take MPLs into account are also carried out to elucidate liquid water transport, particularly through-plane liquid-water profile in a PEM fuel cell. Results from case studies are presented.

30 DIRECT ENERGY CONVERSION↗

Assessment of the analysis capability for core-wide PWR pellet-clad interaction screening of Watts Bar Unit 1

This report illustrates the application of the Virtual Environment for Reactor Applications simulation environment to pressurized water reactor core-wide pellet-clad interaction screening, with emphasis on the multi-dimensional analysis capabilities of the BISON fuel performance code. The Virtual Environment for Reactor Applications codes utilized in this effort include the BISON fuel performance code and the VERA-CS sub-element, which combines the MPACT neutron transport code and the COBRA-TF thermal-hydraulics code. The target reactor for this work is Watts Bar Unit 1, cycle 6 and cycle 7, selected on the basis that pellet-clad interaction failures had occurred during power start up in both cycles, despite the moderate power levels. These instances of failure at Watts Bar Unit 1 offered an interesting test of the code’s veracity and a particularly challenging condition for this assessment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unpolarized azimuthal asymmetries in SIDIS at COMPASS

The study of the spin structure of the nucleon and of the effects due to the quarks transverse momentum are part of the scientific program of COMPASS, a fixed target experiment at the CERN SPS. The azimuthal modulations which appear in the cross-section of SIDIS off unpolarised targets give insight on the intrinsic momentum structure of the nucleon and on the possible correlation between transverse spin and transverse momentum of the quarks. We present the results for the amplitudes of the cos(ϕ), cos(2ϕ), and sin(ϕ) modulatuions (where ϕ is the azimuthal hadron angle in the gamma-nucleon system) obtained from the COMPASS data collected with a 160 GeV/c positive muon beam impinging on a deuteron target. The amplitudes are measured for both positive and negative hadrons, and the results on the dependence of the relevant kinematical variables obtained after a multi dimensional analysis are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extended forward sensitivity analysis of one-dimensional isothermal flow

Sensitivity analysis and uncertainty quantification is an important part of nuclear safety analysis. In this work, forward sensitivity analysis is used to compute solution sensitivities on 1-D fluid flow equations typical of those found in system level codes. Time step sensitivity analysis is included as a method for determining the accumulated error from time discretization. The ability to quantify numerical error arising from the time discretization is a unique and important feature of this method. By knowing the relative sensitivity of time step with other physical parameters, the simulation is allowed to run at optimized time steps without affecting the confidence of the physical parameter sensitivity results. The time step forward sensitivity analysis method can also replace the traditional time step convergence studies that are a key part of code verification with much less computational cost. One well-defined benchmark problem with manufactured solutions is utilized to verify the method; another test isothermal flow problem is used to demonstrate the extended forward sensitivity analysis process. Through these sample problems, the paper shows the feasibility and potential of using the forward sensitivity analysis method to quantify uncertainty in input parameters and time step size for a 1-D system-level thermal-hydraulic safety code. (authors)

97 MATHEMATICS AND COMPUTING↗

A simple UV completion of QED in 5 dimensions

We construct a Lifshitz-like version of five-dimensional (5D) QED which is UV completed and reduces at low energies to ordinary 5D QED. The UV quantum behavior of this theory is very smooth. In particular, the gauge coupling constant is finite at all energy scales and at all orders in perturbation theory. We study the IR properties of this theory, when compactified on a circle, and compare the one-loop energy dependence of the coupling in the Lifshitz theory with that coming from the standard 5D QED effective field theory. The range of validity of the 5D effective field theory is found to agree with the more conservative version of naive dimensional analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAXS Analysis of Embedded Pt Nanocrystals Irradiated with Swift Heavy Ions

Elongated Pt nanocrystals (NCs) formed in SiO{sub 2} by ion implantation, thermal annealing and swift heavy ion irradiation were analyzed by small-angle X-ray scattering (SAXS) and transmission electron microscopy (TEM) measurements. Transmission SAXS measurements were performed in samples aligned at different angles relative to the photon beam resulting in non-isotropic scattering and thus enabling the three dimensional analysis of the NCs. Selected angular sectors of the detector were integrated and analyzed separately, leading to the individual evaluation of both the major and minor dimensions of the rod-shaped NCs. This method enables the use of well established spherical models for the SAXS data analysis and yielded excellent agreement with TEM results.

36 MATERIALS SCIENCE↗

Assessment of the Analysis Capability for Core-wide PWR Pellet-Clad Interaction (PCI) Screening

The Level 1 Milestone, L1:CASL.P13.03, “Assess the analysis capability for core-wide PWR Pellet-Clad Interaction (PCI) screening and demonstrate detailed 3-D analysis on selected sub-region.”, has been completed by the Fuels, Materials and Chemistry and Physics Integration focus areas of CASL. This report illustrates the application of VERA simulation to PWR core-wide PCI screening, with emphasis on the multi-dimensional analysis capabilities of BISON fuel performance code. The VERA codes utilized in this effort are: the fuel performance code BISON and the VERA-CS sub-element, which combines the neutron transport code MPACT and the thermal-hydraulics code COBRA-TF (CTF). The target reactor for this work is Watts Bar Unit 1, Cycles 6 and 7, selected on the basis that PCI failures had occurred during power start-up in both cycles, despite the moderate power levels, which offered an interesting test of the code’s veracity and a particularly challenging condition for this Milestone’s assessment. The analysis began by performing BISON-IN-VERA, i.e. VERA-CS + BISON, quarter-core depletion calculations, from which limiting assemblies and limiting fuel rods were selected using a four-parameter selection criterion: high power, high temperature, small gap thickness and high cladding hoop stress. The cladding material being Westinghouse Zirlo, the analysis utilized a new material model developed for this cladding by CASL’s FMC team using open literature sources. The VERA-CS + BISON analysis resulted in identifying 51 limiting rods as candidates for more detailed PCI analysis using stand-alone BISON, employing local 2D and 3D geometric models. This local-effects BISON analysis provided detailed PCI failure assessment, considering the impact of power histories on the two potential sources of PCI failure: the classical SCC-PCI and the missing pellet surface geometry MPS-PCI. The 51-rod analyses of Watts Bar Unit 1 cycle 6 and 7 revealed that the classical SCC-PCI stress levels were well below the failure threshold determined in a previous CASL study, which implicated the other mode of failure, namely MPS-PCI. Considering MPS defects to be the root cause for the failure, the local-effects calculations was repeated using MPS defect sizes equal to and larger than Westinghouse quality assurance standards. Initial results of this new analysis showed a significant increase in the cladding stress, indicating that an MPS may have been present in cycle 6 and 7 for the failure to occur. In order to determine the size of MPS needed for cycle 6 and 7 rods to fail, a sensitivity study using 2-D and 3-D models was performed. The results showed cladding hoop stresses, while remaining below the failure level for an MPS of equal size to the acceptance standard, continued to increase as the size of the MPS increased. This report has demonstrated the use of BISON, in consort with VERA’s simulation methodology, for core-wide PCI failure screening capability. Utilizing this demonstration, and emulating the PCI margin analysis methodology developed in the EPRI PCI guidelines, BISON-IN-VERA simulation can be used very effectively to develop core power histories to minimize PCI failure potential.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of GOTHIC to Groundwater Transport Analysis - 20152

Migration of pollutants and hazardous wastes, potentially containing radioactive isotopes, via groundwater transport is a concern at most waste cleanup sites. Predictive analysis can be used to evaluate mitigating actions intended to minimize impact on the environment and public exposure. GOTHIC is a multipurpose thermal hydraulics code that is used extensively in the nuclear industry for design, licensing and operation evaluations. It combines the capabilities of typical one-dimensional system codes and the essential features of Computational Fluid Dynamics (CFD) codes for three-dimensional analysis. There are other codes that are specifically developed for groundwater transport analysis and the results presented here are consistent with prior analyses. However, GOTHIC has some unique features that offer advantages for applications related to nuclear waste. Most importantly, it has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B [2] and applicable portions of ASME NQA-1 [3] since 1995. Available GOTHIC capabilities that make the code especially useful for groundwater transport of nuclear materials include: - Tracking of any number of tracer elements for contaminants and other species of interest; - Radioactive decay and progeny of tracer elements; - Adsorption/desorption of tracer elements; - Tracking of any number of dissolved gases; - Release and absorption for dissolved gases; - Vapor phase tracking; - Non-Newtonian fluid modeling. The general porous body modeling approach makes GOTHIC well suited to groundwater transport analysis. The multi-region modeling approach used by GOTHIC simplifies model construction for regions of varying hydrologic characteristics and focuses the computational effort on regions of particular interest while simultaneously capturing the macroscopic response and any feedback effects across the larger domain. The applicability of GOTHIC to groundwater transport applications is demonstrated by comparing code results with available analytic or semi-analytic solutions for groundwater behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H-Canyon Tunnel Inspection System

Cable Analysis: The crawlers is controlled remotely via a long coax cable. In order to make sure we do not damage the cable which could cut our contact (data/power/control), we had to determine the bend radius of it at certain locations. This was done with dimensional analysis in Creo and inputting the information into a MATLAB program. Engineering Drawings: Since many of the crawlers parts, such as the main body, needed to be machined, part drawings were needed to communicate the details necessary for manufacture. Project Overview: The H-Canyon Ventilation Exhaust Tunnel due both to its long service history and exposure to aggressive process offgas chemistry has experienced degradation. In order to allow visual inspection of the condition of the radioactively-contaminated tunnel, a remote crawler was designed to deliver cameras as needed to return high definition video. My involvement included Vendor Searches, Cable Analysis, Thermal Analysis, and Engineering Drawings. Thermal Analysis: In order to see if internal active cooling is needed for the crawler, simplified thermal models were designed to approximate the internal temperatures: Conduction (assumes all heat sources are thermally-coupled to the crawler body); Convection (assumes no heat sources are thermally-bonded to crawler). Going Forward: Continue refining the cable analysis as the crawler model is updated and refined. Use my knowledge gained here to further my skills in engineering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The deterministic chaos and random noise in turbulent jet

A turbulent flow is usually treated as a superposition of coherent structure and incoherent turbulence. In this paper, the largest Lyapunov exponent and the random noise in the near field of round jet and plane jet are estimated with our previously proposed method of chaotic time series analysis [T. L. Yao, et al., Chaos 22, 033102 (2012)]. The results show that the largest Lyapunov exponents of the round jet and plane jet are in direct proportion to the reciprocal of the integral time scale of turbulence, which is in accordance with the results of the dimensional analysis, and the proportionality coefficients are equal. In addition, the random noise of the round jet and plane jet has the same linear relation with the Kolmogorov velocity scale of turbulence. As a result, the random noise may well be from the incoherent disturbance in turbulence, and the coherent structure in turbulence may well follow the rule of chaotic motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Correlations on the Thermal Performance Modeling of Parabolic Trough Collectors

The influence of correlations on the thermal performance modeling of parabolic trough collectors was analyzed in this work. A versatile model for a parabolic trough collector was developed that allows one- and two-dimensional analysis and enables the use of correlations to calculate thermophysical properties and convection heat transfer coefficients. The model also allows the use of constant values for properties and/or coefficients obtained from the evaluation correlations at a specific temperature. The effect of each correlation was evaluated independently, and the results were compared with a reference case that considered a two-dimensional approach and used all the correlations. For the analyzed cases, the correlation for the absorber emittance has the strongest impact on the collector efficiency, leading to a lower error when used. Based on the results, a one-dimensional model approach considering a correlation for the absorber emittance leads to efficiency errors below 3% for collector lengths of up to 243.6 m. Compared with the reference case, a one-dimensional approach using all correlations for a collector with a length of 500 m, and operating with an inlet temperature of 773 K, can result in errors around 9%. However, using constant values for properties and heat transfer coefficients could lead to errors of up to 50%. Multiple thermal models for parabolic trough collectors proposed in the literature rely on a one-dimensional approach, estimated values for the heat transfer coefficients, and constant thermophysical properties. The errors associated with those approaches are analyzed and quantified in this work as a function of the collector length and operation temperature.

absorber emittance↗

Phase stability and microstructure of neutron-irradiated substoichiometric yttrium dihydrides

The impact of the neutron-displacement damage on phase stability and microstructure of substoichiometric yttrium dihydrides (YH x , x <2) were investigated to assess their use as solid moderator in high-temperature nuclear reactors. YH x specimens were, thus, subjected to neutron irradiations in the range of 0.1–2 displacements per yttrium atom (dpa-Y) in the temperature range of 536–878°C at the Oak Ridge National Laboratory's (ORNL's) High Flux Isotope Reactor (HFIR). YH x specimens were initially prepared at stoichiometry (H/Y) ratios of 1.69 and 1.83. HFIR-irradiated specimens were characterized by variety of techniques to investigate H retention characteristics including dimensional analysis, optical microscopy, scanning electron microscopy electron back scatter diffraction (EBSD), transmission electron microscopy, thermal desorption spectroscopy (TDS), and high-energy x-ray diffraction (HE-XRD) characterizations. Overall, YH x exhibited notable structural and phase stability under short-term neutron-irradiation, except for the samples with significant silicon carbide (SiC) interaction at high doses and temperatures. Basic dimensional and mass measurements were misleading for accurate assessment of H retention, as confirmed by EBSD phase maps, XRD line profiles, and TDS signals. Thus, it was discussed that a robust H retention metric is needed to assess irradiated hydrides. Further, nanoscale cavities were observed as a result of the neutron irradiation in all samples. Although no clear impact of dose and irradiation temperature was determined, the initial H/Y ratio had an impact on the cavity number density where low H/Y specimens had high-resistance to cavity formation. The Y-vacancy cluster formation at the collision stage of the displacement cascade and their stabilization by H were considered to be the likely underlying mechanisms for the observed cavity microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping

Purpose: This article presents a general procedural framework to assess the point-by-point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient. Methods: Dose uncertainty is obtained via a three-step process. In the first step, for each voxel in an imaging pair, a cluster of points is obtained by an iterative DIR procedure. In the second step, the dispersion of the points due to the imprecision of the DIR method is used to compute the spatial uncertainty. Two different ways to quantify the spatial uncertainty are presented in this work. Method A consists of a one-dimensional analysis of the modules of the position vectors, whereas method B performs a more detailed 3D analysis of the coordinates of the points. In the third step, the resulting spatial uncertainty estimates are used in combination with the mapped dose distribution to compute the point-by-point dose standard deviation. The process is demonstrated to estimate the dose uncertainty induced by mapping a 62.6 Gy dose delivered on maximum exhale to maximum inhale of a ten-phase four-dimensional lung CT. Results: For the demonstration lung image pair, the standard deviation of inconsistency vectors is found to be up to 9.2 mm with a mean {sigma} of 1.3 mm. This uncertainty results in a maximum estimated dose uncertainty of 29.65 Gy if method A is used and 21.81 Gy for method B. The calculated volume with dose uncertainty above 10.00 Gy is 602 cm{sup 3} for method A and 1422 cm{sup 3} for method B. Conclusions: This procedure represents a useful tool to evaluate the precision of a mapped dose distribution due to the intrinsic DIR uncertainty in a patient. The procedure is flexible, allowing incorporation of alternative intrinsic error models.

60 APPLIED LIFE SCIENCES↗

Operational characteristics of a parallel jet MILD combustion burner system

This study describes the performance and stability characteristics of a parallel jet MILD (Moderate or Intense Low-oxygen Dilution) combustion burner system in a laboratory-scale furnace, in which the reactants and exhaust ports are all mounted on the same wall. Thermal field measurements are presented for cases with and without combustion air preheat, in addition to global temperature and emission measurements for a range of equivalence ratio, heat extraction, air preheat and fuel dilution levels. The present furnace/burner configuration proved to operate without the need for external air preheating, and achieved a high degree of temperature uniformity. Based on an analysis of the temperature distribution and emissions, PSR model predictions, and equilibrium calculations, the CO formation was found to be related to the mixing patterns and furnace temperature rather than reaction quenching by the heat exchanger. The critical equivalence ratio, or excess air level, which maintains low CO emissions is reported for different heat exchanger positions, and an optimum operating condition is identified. Results of CO and NO{sub x} emissions, together with visual observations and a simplified two-dimensional analysis of the furnace aerodynamics, demonstrate that fuel jet momentum controls the stability of this multiple jet system. A stability diagram showing the threshold for stable operation is reported, which is not explained by previous stability criteria. (author)

42 ENGINEERING↗

Flow distribution analysis on the cooling tube network of ITER thermal shield

Thermal shield (TS) is to be installed between the vacuum vessel or the cryostat and the magnets in ITER tokamak to reduce the thermal radiation load to the magnets operating at 4.2K. The TS is cooled by pressurized helium gas at the inlet temperature of 80K. The cooling tube is welded on the TS panel surface and the composed flow network of the TS cooling tubes is complex. The flow rate in each panel should be matched to the thermal design value for effective radiation shielding. This paper presents one dimensional analysis on the flow distribution of cooling tube network for the ITER TS. The hydraulic cooling tube network is modeled by an electrical analogy. Only the cooling tube on the TS surface and its connecting pipe from the manifold are considered in the analysis model. Considering the frictional factor and the local loss in the cooling tube, the hydraulic resistance is expressed as a linear function with respect to mass flow rate. Sub-circuits in the TS are analyzed separately because each circuit is controlled by its own control valve independently. It is found that flow rates in some panels are insufficient compared with the design values. In order to improve the flow distribution, two kinds of design modifications are proposed. The first one is to connect the tubes of the adjacent panels. This will increase the resistance of the tube on the panel where the flow rate is excessive. The other design suggestion is that an orifice is installed at the exit of tube routing where the flow rate is to be reduced. The analysis for the design suggestions shows that the flow mal-distribution is improved significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of general power counting rules in effective field theory

We derive the general counting rules for a quantum effective field theory (EFT) in d dimensions. The rules are valid for strongly and weakly coupled theories, and they predict that all kinetic energy terms are canonically normalized. They determine the energy dependence of scattering cross sections in the range of validity of the EFT expansion. We show that the size of the cross sections is controlled by the Λ power counting of EFT, not by chiral counting, even for chiral perturbation theory (χPT). The relation between Λ and f is generalized to d dimensions. We show that the naive dimensional analysis 4π counting is related to ℏ counting. The EFT counting rules are applied to χPT, low-energy weak interactions, Standard Model EFT and the non-trivial case of Higgs EFT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗