Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗

Survey of methods for calculating sensitivity of general eigenproblems

A survey of methods for sensitivity analysis of the algebraic eigenvalue problem for non-Hermitian matrices is presented. In addition, a modification of one method based on a better normalizing condition is proposed. Methods are classified as Direct or Adjoint and are evaluated for efficiency. Operation counts are presented in terms of matrix size, number of design variables and number of eigenvalues and eigenvectors of interest. The effect of the sparsity of the matrix and its derivatives is also considered, and typical solution times are given. General guidelines are established for the selection of the most efficient method.

Murthy, Durbha V.↗

Derivatives of eigenvalues and eigenvectors of a general complex matrix

A survey of methods for sensitivity analysis of the algebraic eigenvalue problem for non-Hermitian matrices is presented. In addition, a modification of one method based on a better normalizing condition is proposed. Methods are classified as Direct or Adjoint and are evaluated for efficiency. Operation counts are presented in terms of matrix size, number of design variables and number of eigenvalues and eigenvectors of interest. The effect of the sparsity of the matrix and its derivatives is also considered, and typical solution times are given. General guidelines are established for the selection of the most efficient method.

Murthy, Durbha V.↗

Application of lightning data to satellite-based rainfall estimation

Information on lightning may improve rain estimates made from infrared images of a geostationary satellite. We address this proposition through a case from the Cooperative Huntsville Meteorological Experiment (COHMEX). During the afternoon and evening of 13 July 1986 waves of showers and thunderstorms developed over and near the lower Tennessee River Valley. For the shower and thunderstorm region within 200 km of the National Weather Service radar at Nashville, Tennessee, we measure cold-cloud area in a sequence of GOES infrared images covering all but the end of the shower and thunderstorm period. From observations of the NASA/Marshall direction-finding network in this small domain, we also count cloud-to-ground lightning flashes and, from scans of the Nashville radar, we calculate volume rain flux. Using a modified version of the Williams and Houze scheme, over an area within roughly 240 km of the radar (the large domain), we identify and track cold cloud systems. For these systems, over the large domain, we measure area and count flashes; over the small domain, we calculate volume rain flux. For a temperature threshold of 235K, peak cloud area over the small domain lags both peak rain flux and peak flash count by about four hours. At a threshold of 226K, the lag is about two hours. Flashes and flux are matched in phase. Over the large domain, nine storm systems occur. These range in size from 300 to 60,000 km(exp 2); in lifetime, from about 2 1/2 h to 6 h or more. Storm system area lags volume rain flux and flash count; nevertheless, it is linked with these variables. In essential respects the associations were the same when clouds were defined by a threshold of 226K. Tentatively, we conclude that flash counts complement infrared images in providing significant additional information on rain flux.

Martin, David W.↗

The NuSTAR Extragalactic Surveys: The Number Counts Of Active Galactic Nuclei And The Resolved Fraction Of The Cosmic X-ray Background

We present the 3-8 kiloelectronvolts and 8-24 kiloelectronvolts number counts of active galactic nuclei (AGNs) identified in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic surveys. NuSTAR has now resolved 33 percent -39 percent of the X-ray background in the 8-24 kiloelectronvolts band, directly identifying AGNs with obscuring columns up to approximately 10 (exp 25) per square centimeter. In the softer 3-8 kiloelectronvolts band the number counts are in general agreement with those measured by XMM-Newton and Chandra over the flux range 5 times 10 (exp -15) less than or approximately equal to S (3-8 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12) probed by NuSTAR. In the hard 8-24 kiloelectronvolts band NuSTAR probes fluxes over the range 2 times 10 (exp -14) less than or approximately equal to S (8-24 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12), a factor approximately 100 times fainter than previous measurements. The 8-24 kiloelectronvolts number counts match predictions from AGN population synthesis models, directly confirming the existence of a population of obscured and/or hard X-ray sources inferred from the shape of the integrated cosmic X-ray background. The measured NuSTAR counts lie significantly above simple extrapolation with a Euclidian slope to low flux of the Swift/BAT15-55 kiloelectronvolts number counts measured at higher fluxes (S (15-55 kiloelectronvolts) less than or approximately equal to 10 (exp -11) ergs per second per square centimeter), reflecting the evolution of the AGN population between the Swift/BAT local (redshift is less than 0.1) sample and NuSTAR's redshift approximately equal to 1 sample. CXB (Cosmic X-ray Background) synthesis models, which account for AGN evolution, lie above the Swift/BAT measurements, suggesting that they do not fully capture the evolution of obscured AGNs at low redshifts

nucle↗

A high accuracy all-angle gyroscope readout using quantized flux

Means are described to use SQUID magnetometer flux counting and the London moment of a spherical superconducting gyroscope to read out the gyroscope spin axis direction to an accuracy of at least 23 bits per quadrant. The system is discussed in analogy to optical fringe counting as applied to distance measurement. Several methods of applying both analog and digital SQUID magnetometers to the readout problem are given, as well as limitations on each. Described are two methods of increasing the flux available for measurement: magnetizing the gyroscope with a trapped field, and optimizing readout circuit inductances. Finally, the same principle on which the gyroscope readout is based is applied to a description of a high accuracy, flux counting, digital angle encoder.

Anderson, J. T.↗

Far-Ultraviolet Number Counts of Field Galaxies

The Number counts of far-ultraviolet (FUV) galaxies as a function of magnitude provide a direct statistical measure of the density and evolution of star-forming galaxies. We report on the results of measurements of the rest-frame FUV number counts computed from data of several fields including the Hubble Ultra Deep Field, the Hubble Deep Field North, and the GOODS-North and -South fields. These data were obtained from the Hubble Space Telescope Solar Blind Channel of the Advance Camera for Surveys. The number counts cover an AB magnitude range from 20-29 magnitudes, covering a total area of 15.9 arcmin'. We show that the number counts are lower than those in previous studies using smaller areas. The differences in the counts are likely the result of cosmic variance; our new data cover more area and more lines of sight than the previous studies. The slope of our number counts connects well with local FUV counts and they show good agreement with recent semi-analytical models based on dark matter "merger trees".

Voyer, Elysse N.↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Parametric Amplification For Detecting Weak Optical Signals

Optical-communication receivers of proposed type implement high-sensitivity scheme of optical parametric amplification followed by direct detection for reception of extremely weak signals. Incorporates both optical parametric amplification and direct detection into optimized design enhancing effective signal-to-noise ratios during reception in photon-starved (photon-counting) regime. Eliminates need for complexity of heterodyne detection scheme and partly overcomes limitations imposed on older direct-detection schemes by noise generated in receivers and by limits on quantum efficiencies of photodetectors.

Hemmati, Hamid↗

A Novel Measurement of the Anomalous Muon Spin Precession Frequency in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ Experiment operated at Fermi National Accelerator Laboratory (FNAL, or Fermilab) between 2018 and 2023 to produce the world's most precise measurement of the muon's \textit{anomalous magnetic moment}, $a_\mu = \frac{g_\mu - 2}{2}$, which expresses the relative deviation in the muon's $g$-factor from a baseline theoretical expectation that $g_\mu = 2$. In the Standard Model of particle physics, $g_\mu > 2$ and hence $a_\mu > 0$ by a calculable amount that depends on all possible interactions between the muon and all other fundamental particles, including any potentially undiscovered interactions beyond the Standard Model. For this reason, measurements of the electron anomaly $a_e$ and later the muon anomaly $a_\mu$ have helped guide the development of the Standard Model since the inception of quantum field theory, and the measured value of $a_\mu$ provides a valuable constraint for new hypotheses that extend the Standard Model. As of 2006, the leading measurement and Standard Model prediction for $a_\mu$ exhibited tension at the level of about three standard deviations, motivating an improved measurement at Fermilab that could test the tension more precisely. The experiment functions by storing a polarized beam of $\mu^+$ in a uniform magnetic field, which simultaneously induces circular motion and spin precession. As the stored muons undergo the Michel decay $\mu^+ \to e^+ + \nu_e + \bar{\nu}_\mu$, mediated by the parity-violating weak interaction, the rest-frame $e^+$ emission direction is correlated with the parent $\mu^+$ spin orientation. Boosting into the laboratory frame encodes this correlation in the decay $e^+$ energy, which is higher when the emission (i.e. $\mu^+$ spin direction) is aligned with the $\mu^+$ momentum, and lower when opposite. Detectors then count the rate of high-energy decay $e^+$, which modulates at the difference between the $\mu^+$ revolution and spin precession frequencies. This observed frequency, called the \textit{anomalous spin precession frequency} $\omega_a$, is directly proportional to $a_\mu$. The extraction of $\omega_a$ proceeds by fitting the time spectrum of detected $e^+$, which requires precise modeling of the $\omega_a$ oscillation as well as any perturbations from beam dynamics and detector acceptance. Using the $\omega_a$ analysis presented in this work, based on Runs 4 -- 6 of the Muon $g-2$ Experiment at Fermilab, we find that $a_\mu = 0.001\,165\,920\,738(162)$ with a relative uncertainty of 139 parts per billion.

Barrett, Tyler [Cornell U.]↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dust extinction and molecular gas in the dark cloud IC 5146

In this paper we describe a powerful method for mapping the distribution of dust through a molecular cloud using data obtained in large-scale, multiwavelength, infrared imaging surveys. This method combines direct measurements of near-infrared color excess and certain techniques of star counting to derive mean extinctions and map the dust column density distribution through a cloud at higher angular resolutions and greater optical depths than those achieved previously by optical star counting. We report the initial results of the application of this method to a dark cloud complex near the cluster IC 5146, where we have performed coordinated, near-infrared, JHK imaging and (13)CO, C(18)O, and CS millimeter-wave, molecular-line surveys of a large portion of the complex. More than 4000 stars were detected in our JHK survey of the cloud. Of these, all but about a dozen appear to be field stars not associated with the cloud. Star count maps at J band show a striking and detailed anticorrelation between the surface density of J-band sources and CO and CS molecular-line emission. We used the (H-K) colors and positions of nearly 1300 sources to directly measure and map the extinction and thus trace the dust column density through the cloud at an effective angular resolution of 1 min .5. We report an interesting correlation between the measured dispersion in our extinction determinations and the extinction. Modeling this relation indicates that effects of small-scale cloud structure dominate the uncertainties in our measurements. Moreover, we demonstrate that such observations can be used to place constraints on the nature of the spatial distribution of extinction on scales smaller than our resolution. In particular, we show that models in which the dust is distributed uniformly or in discrete high-extinction clumps on scales smaller than (1 min .5) are inconsistent with the observations. We have derived extinctions at the same positions and at the same angular resolution (1 min .7) as our molecular-line observations. This enabled a direct comparison of (13)CO, C(18)O, and CS integrated intensities and column densities with A(sub V) for more than 500 positions in the cloud, corresponding to a range in A(sub V) between 0 to 32 mag of extinction. We found the integrated intensities of (13)CO, C(18)O, and CS to be roughly linearly correlated with extinction over different ranges of extinction. However, for all three molecules we find the scatter in the observed relations to be larger than can be accounted for by instrumental error, suggesting that there are large intrinsic variations in the abundances or excitation of the molecules through the cloud. Mean abundances for all the molecules relative to hydrogen were directly derived from the data. The ratio of (13)CO to C(18)O abundances was found to be significantly higher than the terrestrial ratio in regions where extinction is less than 10 mag. In the same region, the dispersion in the abundance ratio is also found to be very large, suggesting that the abundances of one or both molecules are very unstable even at relatively large cloud optical depths. Beyond 10 mag of extinction the abundances of both species appear very stable with their ratio close to the terrestrial value.

Lada, Charles J.↗

Spacecraft with gradual acceleration of solar panels

A spacecraft (8) includes a movable appendage such as solar panels (12) operated by a stepping motor (28) driven by pulses (311). In order to reduce vibration andor attitude error, the drive pulses are generated by a clock down-counter (312) with variable count ratio. Predetermined desired clock ratios are stored in selectable memories (314a-d), and the selected ratio (R) is coupled to a comparator (330) together with the current ratio (C). An up-down counter (340) establishes the current count-down ratio by counting toward the desired ratio under the control of the comparator; thus, a step change of solar panel speed never occurs. When a direction change is commanded, a flag signal generator (350) disables the selectable memories, and enables a further store (360), which generates a count ratio representing a very slow solar panel rotational rate, so that the rotational rate always slows to a low value before direction is changed. The principles of the invention are applicable to any movable appendage.

Merhav, Tamir R.↗

Stopping criteria for ending autonomous, single detector radiological source searches

While the localization of radiological sources has traditionally been handled with statistical algorithms, such a task can be augmented with advanced machine learning methodologies. The combination of deep and reinforcement learning has provided learning-based navigation to autonomous, single-detector, mobile systems. However, these approaches lacked the capacity to terminate a surveying/search task without outside influence of an operator or perfect knowledge of source location (defeating the purpose of such a system). Two stopping criteria are investigated in this work for a machine learning navigated system: one based upon Bayesian and maximum likelihood estimation (MLE) strategies commonly used in source localization, and a second providing the navigational machine learning network with a “stop search” action. A convolutional neural network was trained via reinforcement learning in a 10 m × 10 m simulated environment to navigate a randomly placed detector-agent to a randomly placed source of varied strength (stopping with perfect knowledge during training). The network agent could move in one of four directions (up, down, left, right) after taking a 1 s count measurement at the current location. During testing, the stopping criteria for this navigational algorithm was based upon a Bayesian likelihood estimation technique of source presence, updating this likelihood after each step, and terminating once the confidence of the source being in a single location exceeded 0.9. A second network was trained and tested with similar architecture as the previous but which contained a fifth action: for self-stopping. The accuracy and speed of localization with set detector and source initializations were compared over 50 trials of MLE-Bayesian approach and 1000 trials of the CNN with self-stopping. The statistical stopping condition yielded a median localization error of ~1.41 m and median localization speed of 12 steps. The machine learning stopping condition yielded a median localization error of 0 m and median localization speed of 17 steps. This work demonstrated two stopping criteria available to a machine learning guided, source localization system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On the Sensitivity of the HAWC Observatory to Gamma-Ray Bursts

We present the sensitivity of HAWC to Gamma Ray Bursts (GRBs). HAWC is a very high-energy gamma-ray observatory currently under construction in Mexico at an altitude of 4100 m. It will observe atmospheric air showers via the water Cherenkov method. HAWC will consist of 300 large water tanks instrumented with 4 photomultipliers each. HAWC has two data acquisition (DAQ) systems. The main DAQ system reads out coincident signals in the tanks and reconstructs the direction and energy of individual atmospheric showers. The scaler DAQ counts the hits in each photomultiplier tube (PMT) in the detector and searches for a statistical excess over the noise of all PMTs. We show that HAWC has a realistic opportunity to observe the high-energy power law components of GRBs that extend at least up to 30 GeV, as it has been observed by Fermi LAT. The two DAQ systems have an energy threshold that is low enough to observe events similar to GRB 090510 and GRB 090902b with the characteristics observed by Fermi LAT. HAWC will provide information about the high-energy spectra of GRBs which in turn will lead to understanding about e-pair attenuation in GRB jets, extragalactic background light absorption, as well as establishing the highest energy to which GRBs accelerate particles.

Hays, E.↗

Assessing the Effect of Spaceflight on the Propensity for Astronauts to Develop Disk Herniation

BACKGROUND: A previous study [1] reported that the instantaneous risk of developing a Herniated Nucleus Pulposus (HNP) was higher in astronauts who had flown at least one mission, as compared with those in the corps who had not yet flown. However, the study only analyzed time to HNP after the first mission (if any) and did not account for the possible effects of multiple missions. While many HNP's occurred well into astronauts' careers or in some cases years after retirement, the higher incidence of HNPs relatively soon after completion of space missions appears to indicate that spaceflight may lead to an increased risk of HNP. The purpose of this study was to support the Human System Risk Board assessment of back pain, evaluate the risk of injury due to dynamic loads, and update the previous dataset which contained events up to December 31, 2006. METHODS: Data was queried from the electronic medical record and provided by the Lifetime Surveillance of Astronaut Health. The data included all 330 United States astronauts from 1959 through February 2014. Cases were confirmed by Magnetic Resonance Imaging, Computerized Tomography, Myelography, operative findings, or through clinical confirmation with a neurologist or neurosurgeon. In this analysis, astronauts who had an HNP at selection into the corps or had an HNP diagnosis prior to their first flight were excluded. The statistical challenges in using the available data to separate effects of spaceflight from those associated with general astronaut training and lifestyle on propensity to develop HNPs are many. The primary outcome is reported date of first HNP (if any), which at best is only an approximation to the actual time of occurrence. To properly analyze this data with a survival analysis model, one must also know the "exposure" time - i.e. how long each astronaut has been at risk for developing an HNP. If an HNP is reported soon after a mission, is it mission caused or general? If the former, exposure time should be counted from the time of landing (assuming the risk of HNP occurring during a mission is zero). If the latter, exposure time should be counted from the time of selection; however we can't directly know which one to use. In our analysis we take both of these possibilities into account with a competing risks model, wherein two distinct stochastic processes are going on: TG = time to HNP (general) and TS = time to HNP (spaceflight). Under this type of model, whichever of these occurs first is what we observe; in other words we don't observe TG or TS, only min(TG, TS). Here, we parameterized the model in terms of separate Weibull hazard functions for each process and estimated all parameters using maximum likelihood. In addition, we allowed for a "cured fraction" - i.e. the possibility that some astronauts may never develop an HNP. RESULTS: Results will include a depiction of the competing hazard functions as well as a probability curve for the relative likelihood that an HNP reported at a given time after a mission is actually mission caused. Other factors, such as dwell time in microgravity and vehicle landing environment will be explored. An overall assessment as to whether spaceflight truly exacerbates HNP risk will be made.

Feiveson, A. H.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗