Search NASA⌕ Search

SEARCH · Search NASA

Results for “directed energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The potential of wire arc directed energy deposition

A diverse team of materials scientists, systems engineers and computational scientists at the Manufacturing Demonstration Facility at Oak Ridge National Laboratory (ORNL) is working closely with industry to employ WA-DED to transform the current manufacturing supply chains and change industry perception of metal-AM-fabricated components.

36 MATERIALS SCIENCE↗

Ultra-fast microwave regeneration of CO 2 solid sorbents for energy-efficient direct air capture

Large-scale deployment of direct air capture (DAC) technologies has become critical for mitigating climate change. Towards this end, energy-efficient regeneration of the sorbents used in the process of carbon capture from air is very important to significantly reduce the high operational cost of DAC. Guanidine compounds can be used with environmentally friendly aqueous amino acids (e.g., potassium sarcosinate) for fast and effective CO 2 capture from air, and have a strong potential for low-energy CO 2 release and sorbent regeneration. In this process, the amino acid absorbs the CO 2 from the air, and the guanidine compounds react with the CO 2 -rich amino acid solution and crystallize as an insoluble carbonate salt. Separation and thermal regeneration of the precipitated guanidine carbonate salt leads to an overall low-temperature and low-energy direct air capture process. Effective CO 2 release from the solid guanidine compound can be achieved by mild heating at 120 °C. Here, in this study, to overcome the relatively inefficient traditional conductive heating of the crystalline solid (i.e., Methylglyoxal-bis(iminoguanidine) carbonate, MGBIG carbonate), we evaluated the feasibility of microwave heating of MGBIG carbonate in terms of power requirement, radiation time, and solids mass for efficient CO 2 desorption. The energy consumption needed by a microwave oven and a conventional oven to regenerate the same mass of the sorbent was directly measured to compare the total energy required per unit mass of regenerated sample and provide an understanding of the potential benefits of microwave regeneration. We found that microwave heating effectively regenerates MGBIG carbonate, which may be facilitated by the water molecules that are co-crystallized with carbonate in the guanidine crystals. Microwave heating at 2.54 GHz with 1250 W is up to 17 times faster than conventional conductive heating at 160 °C, resulting in 40 % electrical energy reduction. These results indicate that microwave regeneration may be an energy-efficient method for fast regeneration of solid sorbents used for direct air capture.

42 ENGINEERING↗

Test of a Novel, Commercial-Scale Wave Energy Direct-Drive Rotary Power Take-Off at the NREL National Wind Technology Center (CRADA CRD-14-571 Final Report)

The National Renewable Energy Laboratory (NREL) will work with Columbia Power Technologies [C-Power] to support work under US DOE DE-EE-0006399, “Build and Test of a Novel, Commercial-Scale Wave Energy Direct-Drive Rotary Power Take-Off Under Realistic Open-Ocean Conditions.” Work will include a review of their design for a novel wave energy direct drive generator. After review, the system will be prototyped and tested in the NREL National Wind Technology Center (NWTC) 5MW dynamometer and data will be recorded and analyzed. Conclusions from data analysis will be used to improve the design prior to completing a version of the system for ocean deployment. Additionally, NREL will work with Columbia Power Technologies [C-Power] to quantify the system levelized cost of energy (LCOE) and analyze the system in agreement with US DOE System Performance Advancement (SPA) goals 1 and 2.

16 TIDAL AND WAVE POWER↗

Envisioning the Future Renewable and Resilient Energy Grids—A Power Grid Revolution Enabled by Renewables, Energy Storage, and Energy Electronics

Today’s power grids are facing tremendous challenges because of the ever-increasing power demand, system complexity, infrastructure cost, knowledge base, and policy and regulatory issues to achieve supply–demand power balance and resiliency with respect to more frequent extreme weather events and cyberattacks. It is particularly challenging when the transition toward 100% intermittent renewable energy sources is considered. Many countries are calling for building up more transmission and distribution lines to increase power delivery capacities. This article is an attempt to answer two urgent questions: Is more transmission and distribution infrastructure really needed to meet the increasing power demand? What kind of future grid infrastructure should we envision and build? This article attempts to answer these questions and proposes the concept of community-centric asynchronous renewable and resilient energy grids. By clearly differentiating the concepts of grid resilience and reliability, the importance of building resilient power electronics’ devices and robust system-level control algorithms to achieve 100% renewable energy integrated resilient grids is presented. To identify the shortcomings and propose advancements, power electronics’ technologies are categorized using the proposed concepts of natural source frequencies (NSf), energy storage, direct energy conversion/control and fault protection (DeCaFp), and high-efficiency energy consumption and buffering (heECaB) technology. The ability of networked microgrids to greatly reduce power outages and power system restoration time is demonstrated by leveraging robust decentralized and centralized control algorithms, identified through a comprehensive literature review. Future research areas are proposed to further enhance grid stability, controllability, cybersecurity, and protection against faults in the presence of 100% renewable sources by leveraging the advanced capabilities of NSf, DeCaFp, and heECaB devices and system-level control algorithms.

14 SOLAR ENERGY↗

Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility

A platform has been developed to study laser-direct-drive energy coupling at the National Ignition Facility (NIF) using a plastic sphere target irradiated in a polar-direct-drive geometry to launch a spherically converging shock wave. To diagnose this system evolution, eight NIF laser beams are directed onto a curved Cu foil to generate Heα line emission at a photon energy of 8.4 keV. These x rays are collected by a 100-ps gated x-ray imager in the opposing port to produce temporally gated radiographs. The platform is capable of acquiring images during and after the laser drive launches the shock wave. A backlighter profile is fit to the radiographs, and the resulting transmission images are Abel inverted to infer radial density profiles of the shock front and to track its temporal evolution. Here, the measurements provide experimental shock trajectories and radial density profiles that are compared to 2D radiation-hydrodynamic simulations using cross-beam energy transfer and nonlocal heat-transport models.

47 OTHER INSTRUMENTATION↗

Determination of the regeneration energy of direct air capture solvents/sorbents using calorimetric methods

Regeneration energy and recyclability are important parameters that dictate the viability of a CO 2 direct air capture (DAC) process. In this study, differential scanning calorimetry (DSC) is used in conjunction with thermogravimetric analysis (TGA) and Fourier Transform Infrared Spectroscopy (FTIR) to evaluate the regeneration energy required for CO 2 -loaded 3 M aqueous potassium sarcosinate (K-SAR) solvent and crystalline methyl-glyoxal-bisiminoguanidine (MGBIG) sorbent. Based on calorimetric measurements, for aqueous K-SAR, the sensible heat amounts to 1.5 GJ/tCO 2 and the enthalpy of desorption is estimated at 3.68 GJ/tCO 2 . The total energy of regeneration will also include the enthalpy of solvent vaporization, which will depend on the thermodynamic conditions and the level of regeneration. For MGBIG, the total regeneration energy required was measured at approximately 7.0 GJ/tCO 2 . Further, FTIR measurements were used to observe CO 2 and H 2 O release during the thermal regeneration process. For K-SAR, CO 2 release is seen to take place at temperatures greater than 80 °C and, for MGBIG, the CO 2 release takes place at temperatures greater than 100 °C. The moderate temperatures required for K-SAR and MGBIG regenerations compared to other DAC solvents/sorbents suggest that low-cost sources of heat, such as geothermal heat, could potentially be used for regeneration to drive down the cost of direct air capture.

42 ENGINEERING↗