Search NASA⌕ Search

SEARCH · Search NASA

Results for “discharge current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Langmuir probe measurements of double-layers in a pulsed discharge

Langmuir probe measurements were carried out which confirm the occurrence of double-layers in an argon positive column. Pulsing the discharge current permitted probe measurements to be performed in the presence of the double-layer. Supplementary evidence, obtained from DC and pulsed discharges, indicated that the double-layers formed in the two modes of operation were similar. The double-layers observed were weak and stable; their relation to other classes of double-layers are discussed, and directions for future work are suggested.

Levine, J. S.↗

Langmuir probe measurements of double-layers in a pulsed discharge

Langmuir probe measurements have been carried out which confirm the occurrence of double-layers in an argon positive column. Pulsing the discharge current permitted probe measurements to be performed in the presence of the double-layer. Supplementary evidence, obtained from dc and pulsed discharges, indicated that the double-layers formed in the two modes of operation were similar. The double-layers observed were weak and stable; their relation to other classes of double-layers is discussed, and directions for future work are suggested.

Levine, J. S.↗

Numerical Simulations of a 20-kW Class Hall Thruster Using the Magnetic-Field-Aligned-Mesh Code Hall2De

This paper reports on numerical simulations of the NASA-300M, a 20-kW class Hall thruster developed at the NASA Glenn Research Center (GRC). The numerical simulations have been performed with a 2-D axisymmetric, magnetic field-aligned-mesh (MFAM) plasma solver developed at the Jet Propulsion Laboratory (JPL). The main objective of the collaborative effort is to combine physics-based simulation, plasma diagnostics and recent findings on erosion physics to design and demonstrate a high-power, high-performance Hall thruster that exceeds the life of state-of-the-art Hall thrusters by more than one order of magnitude. The thruster simulations have been carried out at a discharge voltage of 500 V and discharge current of 40 A. The results indicate that although the impact energy of ions may attain values that are comparable to the discharge voltage along the downstream portions of the channel, a withdrawn ionization region and significant ion focusing combine to sustain erosion rates below 1 mm/kh. A more extensive evaluation of the baseline NASA-300M configuration and re-design of this thruster with magnetically shielded walls constitute the main focus of our work in the coming months.

plasma simulations↗

Environmentally-induced voltage limitations in large space power systems

Large power systems proposed for future space missions imply higher operating voltage requirements which, in turn, will interact with the space plasma environment. The effects of these interactions can only be inferred because of the limited data base of ground simulations, small test samples, and two space flight experiments. This report evaluates floating potentials for a 100 kW power system operating at 300, 500, 750, and 1000 volts in relation to this data base. Of primary concern is the possibility of discharging to space. The implications of such discharges were studied at the 500 volt operational setting. It was found that discharging can shut down the power system if the discharge current exceeds the array short circuit current. Otherwise, a power oscillation can result that ranges from 2 to 20 percent, depending upon the solar array area involved in the discharge. Means of reducing the effect are discussed.

Stevens, N. J.↗

Power processor for a 20CM ion thruster

A power processor breadboard for the JPL 20CM Ion Engine was designed, fabricated, and tested to determine compliance with the electrical specification. The power processor breadboard used the silicon-controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to the ion engine. The breadboard power processor was integrated with the JPL 20CM ion engine and complete testing was performed. The integration tests were performed without any silicon-controlled rectifier failure. This demonstrated the ruggedness of the series resonant inverter in protecting the switching elements during arcing in the ion engine. A method of fault clearing the ion engine and returning back to normal operation without elaborate sequencing and timing control logic was evolved. In this method, the main vaporizer was turned off and the discharge current limit was reduced when an overload existed on the screen/accelerator supply. After the high voltage returned to normal, both the main vaporizer and the discharge were returned to normal.

Biess, J. J.↗

A lithium oxygen secondary battery

Some recent work on a lithium-oxygen secondary battery is reported in which stabilized zirconia oxygen vacancy conducting solid electrolytes were used for the effective separation of respective half-cell reactions. The electroactive material consisted of alloys possessing the general composition Li(x)FeSi2 immersed in a ternary molten salt comprising LiF, LiCl, and Li2O. The manufacture of the cell is described, and discharge-current voltage curves for partially charged cells are shown and discussed. A galvanostatic IR free-changing curve and an IR-free charge-discharge curve are also shown.

Semkow, Krystyna W.↗

Characterization of a High Current, Long Life Hollow Cathode

The advent of higher power spacecraft makes it desirable to use higher power electric propulsion thrusters such as ion thrusters or Hall thrusters. Higher power thrusters require cathodes that are capable of producing higher currents. One application of these higher power spacecraft is deep-space missions that require tens of thousands of hours of operation. This paper presents the approach used to design a high current, long life hollow cathode assembly for that application, along with test results from the corresponding hollow cathode. The design approach used for the candidate hollow cathode was to reduce the temperature gradient in the insert, yielding a lower peak temperature and allowing current to be produced more uniformly along the insert. The lower temperatures result in a hollow cathode with increased life. The hollow cathode designed was successfully operated at currents from 10 to 60 A with flow rates of 5 to 19 sccm with a maximum orifice temperature measured of 1100 C. Data including discharge voltage, keeper voltage, discharge current, flow rates, and orifice plate temperatures are presented.

VanNoord, Jonathan L.↗

The action-integral and energy to explode short gold wires in ambient air

This paper is about electrically induced explosions of short (1 mm) and thin (38 μm diameter) gold bridgewires in ambient air and contrasts this behavior with that observed for longer wires in a vacuum used in applications such as Z-pinch systems. The action-integral (the time integral of the wire current squared) and energy-to-burst are measured using high current discharge systems. It is found that in contrast to some reports, the action-integral to burst is not a constant for a specific wire geometry and material but, instead, is a function of the rate of current change in the wire around the time of burst and the related metric of the current flux at burst. Furthermore, it is found that the accuracy of the constant action-integral to burst approximation is dependent on the discharge system used. Short gold wires such as these have relevancy to exploding bridgewire detonators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of atmospheric pressure single-pulse nanosecond discharge in pin-to-pin configuration

We present an experimental study of nanosecond high-voltage discharges in a pin-to-pin electrode configuration at atmospheric conditions operating in single-pulse mode (no memory effects). Discharge parameters were measured using microwave Rayleigh scattering, laser Rayleigh scattering, optical emission spectroscopy enhanced with a nanosecond probing pulse, and fast photography. Spark and corona discharge regimes were studied for electrode gap sizes 2-10 mm and discharge pulse duration of 90 ns. The spark regime was observed for gaps < 6 mm using discharge pulse energies of 0.6-1 mJ per mm of the gap length. Higher electron number densities, total electron number per gap length, discharge currents, and gas temperatures were observed for smaller electrode gaps and larger pulse energies, reaching maximal values of about 7.5 x 10 15 cm -3 , 3.5 x 10 11 electrons per mm, 22 A, and 4,000 K (at 10 microseconds after the discharge), respectively, for a 2 mm gap and 1 mJ/mm discharge pulse energy. Initial breakdown was followed by a secondary breakdown occurring about 30-70 ns later and was associated with ignition of a cathode spot and transition to cathodic arc. Here, a majority of the discharge pulse energy was deposited into the gas before the secondary breakdown (85-89%). The electron number density after the ns-discharge pulse decayed with a characteristic time scale of 150 ns governed by dissociative recombination and electron attachment to oxygen mechanisms. For the corona regime, substantially lower pulse energies (~0.1 mJ/mm), peak conduction current (1-2 A), and electron numbers (3-5 x 10 10 electrons per mm), and gas temperatures (360 K) were observed.

42 ENGINEERING↗

Dynamic thermal behavior of polycrystalline LaB 6 hollow cathodes

Lanthanum hexaboride (LaB6) hollow cathodes have demonstrated a capability for long life operation, which is critical to many space exploration missions. Thermal characterization of LaB6 hollow cathodes has revealed lower than expected electron emitter temperatures when the cathode reaches a steady state. This phenomenon is observed at discharge currents ranging from 5 to 35 A and xenon mass flow rates of 5–25 SCCM in cathodes with three different orifice diameters. Thus, the currently accepted value of the work function for polycrystalline LaB 6 , 2.67 eV, does not describe well the emission characteristics of LaB6 hollow cathodes operating with internal gas discharges at a steady state. We use empirically measured temperatures combined with a model of the hollow cathode emitter and xenon discharge to estimate the value of the work function, yielding a value ranging from 2.1 to 2.44 eV. This lower work function value implies that LaB6 hollow cathodes are expected to have even longer lifetimes than previously anticipated, further establishing them as a more suited alternative to other conventional cathode technologies for the task of long duration travel. Direct measurements of the work function as a function of depth on a hollow cathode emitter using x-ray photoelectron spectroscopy and ion beam milling indicate that the work function decreases with depth. We postulate several mechanisms that could explain the observed work function enhancement. Altogether, our results have important implications to the design, study approach, and operation of LaB 6 cathodes and potentially other cathodes with hollow configuration. Finally, our work opens the question of why the work function is reduced upon interaction with Xe plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting Maximum Temperatures of a Li-ion Battery on a Simulated Flight Profile using a Model-based Prognostics

One of the challenges in using Li-ion packs in aeronautics is their safety, and thermal runaway (TR) is a major concern. The current engineering solutions to prevent a Li-ion pack from a catastrophic TR require additional mass and volume to isolate cells. The excess mass could be reduced by improving detection and, thus, preventing a TR event. One of the possible early warning indicators of a TR is crossing a threshold temperature. We have developed an approach, based on the Unscented Kalman Filter (UKF), to predict the likelihood of reaching the threshold temperature for simulated flight profiles. The current battery prognostics algorithms for aerospace predict state-of-charge (SOC) and end-of-life (EOL) [1]. We extended this two-level algorithm to predict the maximum temperature during discharge. The amount of heat generated in a cell depends on factors such as cell chemistry, cell packaging, total cycles, operating temperature, and abuse history [2]. Our semi-empirical thermal model depends on three phenomenological parameters which account for those factors. In addition, a two-parameter reduced-order model is developed to predict the temperature rise for short bursts of “random-walk” (RW) discharge current sequence, which simulates a flight's current-loading profile. The performance of these models on different datasets and types of current loading will be presented. To predict the maximal temperatures for future cycles we must estimate the evolution of thermal parameters as the batteries age. It is found that the parameters of the 3-parametric thermal model cannot be estimated only from the RW data. To address the issue, we will present two alternative approaches: i) expanding the datasets to include discharge profiles beyond RWs; ii) model reduction to a two-parametric model. The two approaches will be illustrated by an application to the cycling data from a commercial LG 18650 cell. References: 1. M. Daigle, C.S. Kulkarni, End-of-discharge and End-of-life Prediction in Lithium-ion Batteries with Electrochemistry-based Aging Models, in: AIAA Infotech @ Aerospace, American Institute of Aeronautics and Astronautics, San Diego, California, USA, 2016. 2. M. Börner, et. al, Correlation of aging and thermal stability of commercial 18650-type lithium ion batteries, Journal of Power Sources. 342 (2017) 382–392.

Thermal runaway↗

Proton deflectometry of a capacitor coil target along two axes

A developing application of laser-driven currents is the generation of magnetic fields of picosecond–nanosecond duration with magnitudes exceeding $B=10~\text{T}$. Single-loop and helical coil targets can direct laser-driven discharge currents along wires to generate spatially uniform, quasi-static magnetic fields on the millimetre scale. Here, we present proton deflectometry across two axes of a single-loop coil ranging from 1 to 2 mm in diameter. Comparison with proton tracking simulations shows that measured magnetic fields are the result of kiloampere currents in the coil and electric charges distributed around the coil target. Using this dual-axis platform for proton deflectometry, robust measurements can be made of the evolution of magnetic fields in a capacitor coil target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The variable magnetic baffle as a control device for Kaufman thrusters.

The variable magnetic baffle described in this paper aids in control of electron flow from the hollow cathode plasma into the main discharge region by augmenting the fringe magnetic field which impedes this electron flow in conventionally baffled Kaufman thrusters. A passive, low loss, and automatic control device is obtained by using the discharge current to excite the control winding. Used in conjunction with typical thruster control loops, stable operation has been obtained over a 10:1 throttling range with a 30 cm thruster. Discharge ignition and overcurrent recycling is also facilitated through use of this device in a permanent magnet thruster.

Poeschel, R. L.↗

Performance evaluation of the Russian SPT-100 thruster at NASA LeRC

Performance measurements of a Russian flight-model SPT-100 thruster were obtained as part of a comprehensive program to evaluate engineering issues pertinent to integration with Western spacecraft. Power processing was provided by a US Government developed laboratory power conditioner. When received the thruster had been subjected to only a few hours of acceptance testing by the manufacturer. Accumulated operating time during this study totalled 148 h and included operation of both cathodes. Cathode flow fraction was controlled both manually and using the flow splitter contained within the supplied xenon flow controller. Data were obtained at current levels ranging from 3 A to 5 A and thruster voltages ranging from 200 V to 300 V. Testing centered on the design power of 1.35 kW with a discharge current of 4.5 A. The effects of facility pressure on thruster operation were examined by varying the pressure via injection of xenon into the vacuum chamber. The facility pressure had a significant effect on thruster performance and stability at the conditions tested. Periods of current instabilities were noted throughout the testing period and became more frequent as testing progressed. Performance during periods of stability agreed with previous data obtained in Russian laboratories.

Sankovic, John M.↗

Magnetic Ignition of Pulsed Gas Discharges in Air of Low Pressure in a Coaxial Plasma Gun

The effect of an axial magnetic field on the breakdown voltage of a coaxial system of electrodes has been investigated by earlier workers. For low values of gas pressure times electrode spacing, the breakdown voltage is decreased by the application of the magnetic field. The electron cyclotron radius now assumes the role held by the mean free path in nonmagnetic discharges and the breakdown voltage becomes a function of the magnetic flux density. In this paper the dependence of the formative time lag as a function of the magnetic flux density is established and the feasibility of using a magnetic field for igniting high-voltage, high-current discharges is shown through theory and experiment. With a 36 microfarad capacitor bank charged to 48,000 volts, a peak current of 1.3 x 10( exp 6) amperes in a coaxial type of plasma gun was achieved with a current rise time of only 2 microseconds.

Thom, Karlheinz↗

Mound Spring Complexes in Central Australia: An Analog for Martian Groundwater Fed Outflow Channels?

The arid inland of Australia contains a diversity of landscapes and landscape processes, often of great antiquity, extending back to the Mesozoic and Paleozoic. The potential of this landscape as a source of Mars analogs has, however, been little explored. The few examples studied so far include radiation-tolerant microbes in thermal springs and hematite-silica hydrothermal alteration near Arkaroola in the Finders Ranges, and aeolian landforms at Gurra Gurra water hole the north east of Arkaroola. Further Australian Mars analog studies were provided by the studies of Bourke and Zimbelman of the paleoflood record of the Todd and Hale Rivers in central Australia. To facilitate study of such analogues, Mars Society Australia has embarked on a project to construct a Mars Analog Research Station near Arkaroola. The international scientific community will soon have the opportunity to participate in Mars analog studies in central Australia utilizing this facility. An area of considerable Mars analog potential is the mound spring complexes that occur at the margins of the Great Artesian Basin (GAB) which underlies 22% of the Australian continent and covers 1.7 million km2. The mound springs are formed when ground water flows to a topographic low, and subsurface strata dips up causing a hydrological head at the surface. Minerals precipitated at the spring discharge zone form low mesas or "mounds", the height of which are controlled by the hydrological head. This paper describes the Dalhousie Mound Spring Complex (DMC) in the northern part of South Australia (Figure 1), and its potential as a Mars analog. Hydrogeology: The DMC consists of a cluster of more than 60 active springs formed by natural discharge from the GAB). Total measured discharge from the GAB is 1.74 GL per day, estimated unfocussed natural leakage through the aquaclude is thought be approximately equal to this figure. Some 54 ML per day are currently discharged by the DMC, 3% of the measured total. The discharged artesian waters are of low to moderate salinity (700 - 9400 ppm), near neutral pH (6.8-7.3) and warm (20-46 C). The elevated temperatures are due to passage of the groundwater through deeply buried (up to 3 km) aquifers in an region of high heat flow, rather than magmatic heating. The waters also contain high levels of dissolved iron and H2S and less than 1 ppm dissolved oxygen. The water is carried in the Late Jurassic Algebuckina Sandstone beneath the aquaclude of the Bulldog Shale. It is brought near the surface by the mid-Cenozoic Dalhousie anticline and the ground water flow focused along a series of faults that breach the anticline's crest.

Clarke, J. D. A.↗

Integration Tests of the 4 kW-class High Voltage Hall Accelerator Power Processing Unit with the HiVHAc and the SPT-140 Hall Effect Thrusters

NASAs Science Mission Directorate is sponsoring the development of a 4 kW-class Hall propulsion system for implementation in NASA science and exploration missions. The main components of the system include the High Voltage Hall Accelerator (HiVHAc), an engineering model power processing unit (PPU) developed by Colorado Power Electronics, and a xenon flow control module (XFCM) developed by VACCO Industries. NASA Glenn Research Center is performing integrated tests of the Hall thruster propulsion system. This presentation presents results from integrated tests of the PPU and XFCM with the HiVHAc engineering development thruster and a SPT-140 thruster provided by Space System Loral. The results presented in this paper demonstrate thruster discharge initiation, open-loop and closed-loop control of the discharge current with anode flow for both the HiVHAc and the SPT-140 thrusters. Integrated tests with the SPT-140 thruster indicated that the PPU was able to repeatedly initiate the thrusters discharge, achieve steady state operation, and successfully throttle the thruster between 1.5 and 4.5 kW. The measured SPT-140 performance was identical to levels reported by Space Systems Loral.

Hall Thrusters↗

Simplified Numerical Description of SPT Operations

A simplified numerical model of the plasma discharge within the SPT-100 stationary plasma thruster was developed to aid in understanding thruster operation. A one dimensional description was used. Non-axial velocities were neglected except for the azimuthal electron velocity. A nominal operating condition of 4.5 mg/s of xenon anode flow was considered with 4.5 Amperes of discharge current, and a peak radial magnetic field strength of 130 Gauss. For these conditions, the calculated results indicated ionization fractions of 0.99 near the thruster exit with a potential drop across the discharge of approximately 250 Volts. Peak calculated electron temperatures were found to be sensitive to the choice of total ionization cross section for ionization of atomic xenon by electron bombardment and ranged from 51 eV to 60 eV. The calculated ionization fraction, potential drop, and electron number density agree favorably with previous experiments. Calculated electron temperatures are higher than previously measured.

Manzella, David H.↗