Search NASA⌕ Search

SEARCH · Search NASA

Results for “distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-F-E-02: A Feasibility Study for Application of Metal Artifact Reduction Techniques in MR-Guided Brachytherapy Gynecological Cancer with Titanium Applicators

Purpose: Utilization of Titanium Tandem and Ring (T&R) applicators in MR-guided brachytherapy has become widespread for gynecological cancer treatment. However, Titanium causes magnetic field disturbance and susceptibility artifact, which complicate image interpretation. In this study, metal artifact reduction techniques were employed to improve the image quality and reduce the metal related artifacts. Methods: Several techniques were employed to reduce the metal artifact caused by titanium T&R applicator. These techniques include Metal Artifact Reduction Sequence (MARS), View Angle Tilting (VAT) to correct in-plane distortion, and Slice Encoding for Metal Artifact Correction (SEMAC) for through-plane artifact correction. Moreover, MARS can be combined with VAT to further reduce the in-plane artifact by reapplying the selection gradients during the readout (MARS+VAT). SEMAC uses a slice selective excitation but acquires additional z-encodings in order to resolve off-resonant signal and to reduce through-plane distortions. Results: Comparison between the clinical sequences revealed that increasing the bandwidth reduces the error in measured diameter of T&R. However, the error is larger than 4mm for the best case with highest bandwidth and spatial resolution. MARS+VAT with isotropic resolution of 1mm reduced the error to 1.9mm which is the least among the examined 2D sequences. The measured diameter of tandem from SEMAC+VAT has the closest value to the actual diameter of tandem (3.2mm) and the error was reduced to less than 1mm. In addition, SEMAC+VAT significantly reduces the blooming artifact in the ring compared to clinical sequences. Conclusion: A higher bandwidth and spatial resolution sequence reduces the artifact and diameter of applicator with a slight compromise in SNR. Metal artifact reduction sequences decrease the distortion associated with titanium applicator. SEMAC+VAT sequence in combination with VAT revealed promising results for titanium imaging and can be utilized for MR-guided brachytherapy in gynecological cancer. The author is employee with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

The Hawaii Meteorology, Energy and Transmission (MET) Toolkit

Reliable long-term resource adequacy and grid planning in Hawaii require precise, multi-decadal meteorological records. This paper introduces the Hawaii Meteorology, Energy and Transmission (MET) Toolkit, a 26-year (2000-2025) high-fidelity atmospheric dataset developed by the National Laboratory of the Rockies (NLR). We present a validation study of the underlying WRF model configurations, comparing the legacy MYNN PBL scheme against an alternative YSU formulation. Using vertical lidar profiles and surface buoy data, our analysis identified a foundational geometric distortion in the legacy NOW-23 Hawaii dataset caused by an incorrect grid projection. When evaluated on a corrected, zero-distortion grid, the YSU scheme demonstrated superior performance in bias and cRMSE compared to the legacy setup. To address these findings, the MET Toolkit has been re-produced as a unified 26-year record using the optimized YSU setup and corrected geometry. This dataset offers the Hawaii power sector a robust, validated, and homogenous reference for future grid resilience and energy integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-dependent phase error correction using digital waveform synthesis

The various technologies presented herein relate to correcting a time-dependent phase error generated as part of the formation of a radar waveform. A waveform can be pre-distorted to facilitate correction of an error induced into the waveform by a downstream operation/component in a radar system. For example, amplifier power droop effect can engender a time-dependent phase error in a waveform as part of a radar signal generating operation. The error can be quantified and an according complimentary distortion can be applied to the waveform to facilitate negation of the error during the subsequent processing of the waveform. A time domain correction can be applied by a phase error correction look up table incorporated into a waveform phase generator.

42 ENGINEERING↗

Dedicated Magnetic Resonance Imaging in the Radiotherapy Clinic

Purpose: To introduce a novel technology arrangement in an integrated environment and outline the logistics model needed to incorporate dedicated magnetic resonance (MR) imaging in the radiotherapy workflow. An initial attempt was made to analyze the value and feasibility of MR-only imaging compared to computed tomography (CT) imaging, testing the assumption that MR is a better choice for target and healthy tissue delineation in radiotherapy. Methods and Materials: A 1.5-T MR unit with a 70-cm-bore size was installed close to a linear accelerator, and a special trolley was developed for transporting patients who were fixated in advance between the MR unit and the accelerator. New MR-based workflow procedures were developed and evaluated. Results: MR-only treatment planning has been facilitated, thus avoiding all registration errors between CT and MR scans, but several new aspects of MR imaging must be considered. Electron density information must be obtained by other methods. Generation of digitally reconstructed radiographs (DRR) for x-ray setup verification is not straight forward, and reliable corrections of geometrical distortions must be applied. The feasibility of MR imaging virtual simulation has been demonstrated, but a key challenge to overcome is correct determination of the skeleton, which is often needed for the traditional approach of beam modeling. The trolley solution allows for a highly precise setup for soft tissue tumors without the invasive handling of radiopaque markers. Conclusions: The new logistics model with an integrated MR unit is efficient and will allow for improved tumor definition and geometrical precision without a significant loss of dosimetric accuracy. The most significant development needed is improved bone imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alignment and evaluation of the cryogenic corrected infrared astronomical satellite /IRAS/ telescope

Room temperature alignment and evaluation techniques for the Infrared Astronomical Satellite (IRAS) telescope, which has a primary mirror figured to correct for surface distortions and the 2 K operating temperature are discussed. Interferometric cryogenic testing of the 0.6 m, f/1.5 lightweighted beryllium primary mirror at its intended operating temperature reveals surface distortions that can be modeled with Zernike polynomials. With this model, it becomes possible to derive the 'inverse' of the cryowavefront error (ideal cryo mirror) and to figure the cryo correction into the primary mirror using Perkin-Elmer's Computer Controlled Polisher. It is recognized that during room temperature assembly of the system, misalignment of the secondary mirror can introduce additional unwanted aberrations that may cancel or distort the wavefront errors purposely introduced by the cryo figuring. To avoid this possible degradation and to ensure optimum telescope performance, the system Zernike polynomial coefficients and wavefront maps generated from the in-process alignment interferograms are monitored and compared to Zernike coefficients and wavefront maps for the cryo corrected primary mirror.

Harned, N.↗

Fused silica mirror development for SIRTF

An advanced design, lightweight, fuse-quartz mirror of sandwich construction was evaluated for optical figure performance at cryogenic temperatures. A low temperature shroud was constructed with an integral mirror mount and interface to a cryostat for use in a vacuum chamber. The mirror was tested to 13 K. Cryogenic distortion of the mirror was measured interferometrically. Separate interferometry of the chamber window during the test permitted subtraction of the small window distortions from the data. Results indicate that the imaging performance of helium cooled, infrared telescopes will be improved using this type of mirror without correction of cryogenic distortion of the primary mirror.

Barnes, W. P., Jr.↗

X-ray nanofocusing by kinoform lenses: A comparative study using different modeling approaches

We conduct a comparative study on various kinoform lenses (KLs) for x-ray nanofocusing by using the geometrical theory, the dynamical diffraction theory, and the beam propagation method. This study shows that the geometrical theory becomes invalid to describe the performance of a KL for nanofocusing. The strong edge diffraction effect from individual lens element, which distorts the desired wave field, leads to a reduction in the effective numerical aperture and imposes a limit on how small a focus a KL can achieve. Because this effect is associated with a finite thickness of a lens, larger lens thickness depicts a stronger distortion. We find that a short KL where all lens elements are folded back to a single plane shows an illumination preference: if the illuminating geometry is in favor of the Bragg diffraction for a focusing order, its performance is enhanced and vice versa. We also find that a short KL usually outperforms its long version where all lens elements do not lie in a single plane because the short one suffers less the wave field distortion due to the edge diffraction. Simulation results suggest that for a long KL, an adaptive lens design is needed to correct the wave field distortion in order to achieve a better performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of minimum correction wind tunnels

Flow distortions due to wind tunnel wall interference may be accounted for if the model to tunnel ratio is small, but the theory becomes less reliable as the model becomes larger. This paper presents theoretical analysis and experimental evidence which supports a new concept of wind tunnel. The method employs active control of flow through the walls so that the model is in approximately free air conditions during the test. Practical considerations in the design of such a tunnel are presented. Results indicate that a minimum correction wind tunnel may be achieved with active walls of relatively low porosity.

Bernstein, S.↗

Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning

Purpose: The use of magnetic resonance imaging (MRI) in radiation oncology is expanding rapidly, and more clinics are integrating MRI into their radiation therapy workflows. However, radiation therapy presents a new set of challenges and places additional constraints on MRI compared to diagnostic radiology that, if not properly addressed, can undermine the advantages MRI offers for radiation treatment planning (RTP). The authors introduce here strategies to manage several challenges of using MRI for virtual simulation in external beam RTP. Methods: A total of 810 clinical MRI simulation exams were performed using a dedicated MRI scanner for external beam RTP of brain, breast, cervix, head and neck, liver, pancreas, prostate, and sarcoma cancers. Patients were imaged in treatment position using MRI-optimal immobilization devices. Radiofrequency (RF) coil configurations and scan protocols were optimized based on RTP constraints. Off-resonance and gradient nonlinearity-induced geometric distortions were minimized or corrected prior to using images for RTP. A multidisciplinary MRI simulation guide, along with window width and level presets, was created to standardize use of MR images during RTP. A quality assurance program was implemented to maintain accuracy and repeatability of MRI simulation exams. Results: The combination of a large bore scanner, high field strength, and circumferentially wrapped, flexible phased array RF receive coils permitted acquisition of thin slice images with high contrast-to-noise ratio (CNR) and image intensity uniformity, while simultaneously accommodating patient setup and immobilization devices. Postprocessing corrections and alternative acquisition methods were required to reduce or correct off-resonance and gradient nonlinearity induced geometric distortions. Conclusions: The methodology described herein contains practical strategies the authors have implemented through lessons learned performing clinical MRI simulation exams. In their experience, these strategies provide robust, high fidelity, high contrast MR images suitable for external beam RTP.

60 APPLIED LIFE SCIENCES↗

Spline function approximation techniques for image geometric distortion representation

Least squares approximation techniques were developed for use in computer aided correction of spatial image distortions for registration of multitemporal remote sensor imagery. Polynomials were first used to define image distortion over the entire two dimensional image space. Spline functions were then investigated to determine if the combination of lower order polynomials could approximate a higher order distortion with less computational difficulty. Algorithms for generating approximating functions were developed and applied to the description of image distortion in aircraft multispectral scanner imagery. Other applications of the techniques were suggested for earth resources data processing areas other than geometric distortion representation.

Anuta, P. E.↗

Screening actuator locations for static shape control

Correction of shape distortion due to zero-mean normally distributed errors in structural sizes which are random variables is examined. A bound on the maximum improvement in the expected value of the root-mean-square shape error is obtained. The shape correction associated with the optimal actuators is also characterized. An actuator effectiveness index is developed and shown to be helpful in screening actuator locations in the structure. The results are specialized to a simple form for truss structures composed of nominally identical members. The bound and effectiveness index are tested on a 55-m radiometer antenna truss structure. It is found that previously obtained results for optimum actuators had a performance close to the bound obtained here. Furthermore, the actuators associated with the optimum design are shown to have high effectiveness indices. Since only a small fraction of truss elements tend to have high effectiveness indices, the proposed screening procedure can greatly reduce the number of truss members that need to be considered as actuator sites.

Haftka, Raphael T.↗

Circuit reduces distortion of FM modulator

Correction circuit improves the linearity of a voltage-variable capacitor used to modulate a free-running oscillator. This improvement only applies to audio frequency modulation and will not correct for slowly varying dc input in some telemetry systems.

Source record↗

AVHRR image navigation - Summary and review

The navigation of imagery from polar orbiting weather satellites includes the correction for geometric distortions due to earth shape/earth rotation, satellite orbit variations, and satellite attitude along with the resampling of the satellite image to a selected geographic map projection. The routine image navigation procedure also compensates for the distortion of the satellite imagery due to the nonlinear scanning of the sensor system. This paper reviews general methods for performing this image navigation, ranging from a method that assumes no orbital information and, thus, relies on nominal orbital parameter values and image corrections computed by matching ground control points (GCPs), to a method that uses high-quality satellite ephemeris data to make the correction with a limited number of GCPs. A procedure to optimize the image navigation by using a spatial remapping, or interpolation, is introduced and outlined. Recommendations are made for people interested in the processing of AVHRR imagery.

Emery, William J.↗

Radiance profile enhancement for solar occultation measurements

It is pointed out that distortions in received signals in solar occultation measurements made from space derive from the systematic motion of the electrooptical sensor. In a wide range of cases, the motion-related signal distortions brought about by the instrument's full modulation transfer function are as important as those from the optics. It is shown through simulation that existing techniques in the field of digital-image processing can be applied directly to solar occultation experiments to correct for these distortions. The resulting enhanced radiation profile is found to be much closer to the true radiance profile than is the sampled output of the instrument.

Gomberg, R. I.↗

Limits on static shape control for space structures

This paper deals with correction of shape distortion due to zero-mean normally distributed errors in structural sizes. The concept of ideal actuators - actuators that can produce any desired displacement field - is introduced. Using this concept, a bound on the possible improvement in the expected value of the root-mean-square shape error is obtained. The shape correction associated with the ideal actuators is also characterized. An actuator effectiveness index is developed by comparing the displacement field generated by the actuator to the ideal. The results are specialized to a simple form for truss structures composed of nominally identical members. The bound and effectiveness index are tested on a 55-m radiometer antenna truss structure. It is found that previously obtained results for optimum actuators had a performance close to the bound obtained here. Also, it is found that large numbers of actuators are needed for large reductions in shape errors. Furthermore, the actuators associated with the optimum design are shown to have high effectiveness indices. Since only a small fraction of truss elements tend to have high effectiveness indices, the use of the effectiveness index can greatly reduce the number of truss members that need to be considered actuator sites.

Haftka, Raphael T.↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

Dosimetric feasibility of real-time MRI-guided proton therapy

Purpose: Magnetic resonance imaging (MRI) is a prime candidate for image-guided radiotherapy. This study was designed to assess the feasibility of real-time MRI-guided proton therapy by quantifying the dosimetric effects induced by the magnetic field in patients’ plans and identifying the associated clinical consequences. Methods: Monte Carlo dose calculation was performed for nine patients of various treatment sites (lung, liver, prostate, brain, skull-base, and spine) and tissue homogeneities, in the presence of 0.5 and 1.5 T magnetic fields. Dose volume histogram (DVH) parameters such as D{sub 95}, D{sub 5}, and V{sub 20} as well as equivalent uniform dose were compared for the target and organs at risk, before and after applying the magnetic field. The authors further assessed whether the plans affected by clinically relevant dose distortions could be corrected independent of the planning system. Results: By comparing the resulting dose distributions and analyzing the respective DVHs, it was determined that despite the observed lateral beam deflection, for magnetic fields of up to 0.5 T, neither was the target coverage jeopardized nor was the dose to the nearby organs increased in all cases except for prostate. However, for a 1.5 T magnetic field, the dose distortions were more pronounced and of clinical concern in all cases except for spine. In such circumstances, the target was severely underdosed, as indicated by a decrease in D{sub 95} of up to 41% of the prescribed dose compared to the nominal situation (no magnetic field). Sites such as liver and spine were less affected due to higher tissue homogeneity, typically smaller beam range, and the choice of beam directions. Simulations revealed that small modifications to certain plan parameters such as beam isocenter (up to 19 mm) and gantry angle (up to 10°) are sufficient to compensate for the magnetic field-induced dose disturbances. The authors’ observations indicate that the degree of required corrections strongly depends on the beam range and direction relative to the magnetic field. This method was also applicable to more heterogeneous scenarios such as skull-base tumors. Conclusions: This study confirmed the dosimetric feasibility of real-time MRI-guided proton therapy and delivering a clinically acceptable dose to patients with various tumor locations within magnetic fields of up to 1.5 T. This work could serve as a guide and encouragement for further efforts toward clinical implementation of hybrid MRI–proton gantry systems.

60 APPLIED LIFE SCIENCES↗

Effects of the preparation processes on structural, electronic, and optical properties of LaHoO{sub 3}

Highlights: • The preparation of LaHoO{sub 3} by combustion and hydrothermal techniques was performed. • The crystal structure and characterization of the synthesized oxides were carried out. • The lattice distortions have effects on Raman, luminescence and optical band gap. • Electronic properties and band structure have been carried out by DFT method. • Sample prepared by hydrothermal process gives higher emission intensities. - ABSTRACT: Lanthanum holmium oxide (LaHoO{sub 3}) was synthesized using combustion and hydrothermal processes in order to compare the effects of preparation method on structural, electronic, and optical properties. For this purpose, the as-prepared samples were characterized with infrared spectroscopy, Raman scattering, X-ray diffraction, and scanning electronic microscopy. The Rietveld refinements structure of as-prepared samples show that lattice distortions and volume expansion were obtained for LaHoO{sub 3} synthesized with hydrothermal method compared to combustion process. The luminescence properties were investigated upon 488 and 750 nm laser excitations. The emission curves show the presence of characteristic Ho{sup 3+} transitions with a higher emission intensity for a sample prepared by hydrothermal method than the one obtained by combustion process. The structures properties effects on the band structure and the density of states were realized via generalized gradient approximation functional with Hubbard correction. The lattice distortions were found to have effects on Raman, luminescence and optical band gap.

36 MATERIALS SCIENCE↗