Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed fiber sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Towards the design of a wideband reflective long period grating distributed sensor

Abstract In this paper, we computationally investigate the effects of metal coating length and coating coverage on the reflected spectrum of a long period grating (LPG) over a broad bandwidth. Simulation results indicate that coating the tail end of the fiber between the LPG and the end facet of the fiber provides a reflected spectrum that mimics the LPG transmission spectrum shape over a 400 nm bandwidth. Based on single LPG simulation results, we present the design of a distributed LPG structure containing a multiple number ( n ) of LPGs in reflection mode for the first time. Simulation results for n = 1, 2, and 3 are presented here to demonstrate the concept of a distributed reflective LPG design. It is expected that such a sensor will open a new window for distributed sensing using reflective LPGs.

Rana, Sohel (ORCID:0000000262813555)↗

Fiber-optic sensor packaging assessment and benchmarking for embedded sensing applications

Fiber optic-based sensing for non-destructive evaluation (NDE) and structural health monitoring of various infrastructure and energy assets is an increasingly important sensing scheme. Because of their immunity to electromagnetic interferences, versatility in sensing mechanisms and designs as well as capability for distributed sensing, the fiber optic sensing is of great interest for embedding within infrastructures using advanced manufacturing methods. However, the protection of fiber optic sensors during advanced manufacturing-based embedding is an important aspect for infrastructure monitoring in practice. While successful installation of fiber optic sensors has been accomplished through application of epoxy or adhesives on infrastructure surfaces, there has been only limited investigation of fiber protection packaging schemes which are compatible with in-situ repair techniques such as the metallic cold-spray. With increasing interest and importance of cold spray-based repair processes, the integration of fiber optic sensors simultaneously during the repair is equally important. In this work, we focus our efforts on investigating various types of packaging schemes for their compatibility and integrability on the surfaces of metallic structures such as oil and gas pipelines during an in-situ repair coating. First, we consider sandblasting using silica sand particles of various size for optical fibers on the surface of a metallic coupon as a useful proxy test of sensor packaging stability. Structural damage of packaging is characterized by means of optical microscopy and the optical integrity of embedded fiber optic cables is examined using optical backscatter reflectometry (OBR). In addition, initial investigation of metallic cold-spray embedded fiber optic cables under various packaging on metallic substrates is also considered with early conclusions and future directions.

Fiber-optic sensors, Sensors packaging, Metallic C↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

Distributed Sapphire Fiber Bragg Gratings Based Thermal Profiling of Submerged Entry Nozzles

This research focuses on the application of sapphire fiber Bragg gratings (FBGs) for instrumentation in submerged entry nozzles (SEN) within the steelmaking industry. The SEN is pivotal for transferring molten steel from a tundish to a mold, while preventing the infiltration of oxygen and nitrogen from the surrounding environment. Maintaining optimal flow conditions in the mold is crucial for ensuring casting process stability and maintaining high quality steel. Sapphire FBG sensors have been instrumented in SENs to enable distributed thermal mapping for monitoring the health of the SEN. The optical sensor comprises three cascaded sapphire FBGs inscribed using femtosecond laser technology into a one-meter-long sapphire crystalline fiber. The sensor underwent characterization in a laboratory setting up to 1600°C and was tested for long-term stability over 40 hours under extreme environmental conditions. The coupling between silica and sapphire fibers was investigated and implemented during sensor packaging. Here, the sensor successfully captured the pre-heat sequence of the SEN in real-world steelmaking operations. Compared to conventional thermocouples, sapphire FBG sensors demonstrated exceptional efficiency and precision. They offer potential benefits such as increased productivity, reduced energy consumption, and minimized carbon footprint in the steel industry.

Sapphire Fiber Bragg Grating↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

Distributed measurement of minimum and maximum in-situ stress in substrates

A system for performing distributed measurements of in-situ stress includes an expandable element with at least one fiber optic sensor. The expandable element can be positioned at various depths in a hole in a substrate. A pressurizing device expands (and contracts) the expandable element when the expandable element is inserted in the hole in the substrate to exert pressure on the hole wall. A pressure sensor provides a sensor output indicative of a pressure applied to the hole wall by the expandable element. The fiber optic sensor and an optical interrogator measure strain along a length of the sensor in a continuous, high spatial resolution manner Based on the measured strain and pressure sensor output, the system determines various properties of the substrate such as, minimum principal stress, maximum principal stress, and/or principal stress direction associated with one or more fractures in the substrate, as well as substrate modulus.

Ohanian, III, Osgar John↗

RIC Advanced Sensors & Controls FWP: Novel Sensors for Boilers

Overview and brief project update on 3 tasks within the RIC Advanced Sensors & Controls FWP with direct applications to coal fired boiler temperature sensing. Task 32, Field demonstration of distributed temperature measurement with optical fiber for fossil energy power generation applications. Task 47, In-situ temperature measurements via reactive particles. Task 48, Ultrafast laser measurements for power generation environments.

coal boilers↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report FY20 Q2

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (like a redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed, most primary component have been fabricated, primary components are being assembled in preparation for initial testing, and procurement is continuing with the secondary system components. Since the FY19 THETA status report, The THETA primary system components are at Argonne National Laboratory (ANL) and have been dry assembled. The secondary sodium system for heat rejection from intermediate heat exchanger has all been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger has been procured.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor system play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. Nonetheless, challenges emerge as distances grow due to signal attenuation and noise interference resulting in measurement errors. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond 10’s of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. This approach proves particularly advantageous in BOTDA systems, where accurate measurement of Brillouin scattering signals is paramount for long-range sensing, while concurrently safeguarding high spatial resolutions. In summary, this research has shown a holistic exploration of extending BOTDA's distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Date Release Report for Large Surface Explosion Coupling Experiment (LSECE) Nevada National Security Site

The DTRA sponsored 2020-2022 Large Surface Explosion Coupling Experiment (LSECE) consists of two large ground surface chemical explosions, data collection, analysis and modeling carried out in 2020-2022. The LSECE chemical explosions were carried out at the site of prior NNSA sponsored buried chemical explosions that were part of the Source Physics Experiment (SPE) Phase II in Dry Alluvium Geology (DAG). This report described the data collected under LSECE that is being made publicly available. The prior buried explosion DAG data are described in a separate report (https://www.osti.gov/biblio/1825534) and are also publicly available. The LSECE explosions, data analysis and numerical modeling work sponsored by DTRA were intended to address three objectives: 1) Generate seismo-acoustic data to test and improve numerical models of explosion energy coupling in dry alluvium geology; 2) To improve seismo-acoustic yield estimation techniques as a function of depth and medium properties; 3) To study and improve acoustic propagation modeling under two different atmospheric conditions. The LSECE data that were collected have expanded the prior DAG buried explosion dataset to include surface chemical explosions recorded on a common set of seismo-acoustic stations. They have allowed a more detailed study of above and below surface seismo-acoustic energy coupling with applications to explosion monitoring and assessment. The two approximately 1-ton TNT equivalent yield LSECE explosions were detonated at different times of the day to explore the effects of the different atmospheric conditions. The first chemical explosion “Artemis” was conducted before dawn when temperature inversions were present. The second chemical explosion “Apollo” was conducted on a sunny afternoon when the temperature gradient was more linear. The LSECE chemical explosion data were also collected across a variety of different sensor types to allow evaluation of their effectiveness in recovering useful information. The LSECE instrumentation included fiber optic or Distributed Acoustic Sensing (DAS), a dense array or Large-N array of seismometers, borehole accelerometers, DAS and a velocity meter, airborne acoustic instruments and a variety of visual and remote sensing data.

58 GEOSCIENCES↗