Search NASA⌕ Search

SEARCH · Search NASA

Results for “district planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Finding of Effect, And Mitigation Documentation for Building 23-620, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15283), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-620 was built in 1968 as office space for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons. In the 1990s, it became a maintenance facility for Reynolds Electrical & Engineering Company (REECo), and eventually, it became the Real Estate Services building in 2004. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-620 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-620 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation Report: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-620 (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) in the Mercury Historic District (MHD, SHPO Resource No. D230). This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

An Architectural Survey of the REECo Maintenance Compound, Area 6, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to install a 26.45-mile-long 138-kilovolt (kV) transmission line on the Nevada National Security Site (NNSS) in Nye County, Nevada. This new transmission line will upgrade the electrical transmission system and provide reliable power between Mercury Switching Station in Area 23 and the U1a Facility in Area 1. The proposed upgrade to the power transmission system constitutes an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. A portion of this new transmission line will cross the western perimeter of the Reynolds Electrical and Engineering Company (REECo) Maintenance Compound located in Area 6 of the NNSS. This compound with its trade shops, storage sheds, and yards served as a general construction facility that supported nuclear testing activities on the NNSS from 1967 to 1992. Although three architectural resources in the compound have previously been recorded and evaluated for the National Register of Historic Places (NRHP), other resources within it have not, nor has the compound been recorded and evaluated as a potential district. The State Historic Preservation Officer (SHPO) concurred with NNSA/NFO’s determination that the unevaluated REECo Maintenance Compound will be adversely affected by the proposed undertaking (Reed 2021). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-22NA25553 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Installation of a 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility and the Removal of the Historic 138-kilovolt Transmission Line from the Mercury Switching Station to the U1a Facility in Areas 1, 3, 5, 6, and 23 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. This architectural survey report was prepared in accordance with MOA Stipulation III.B. It describes the origins, history, layout, and functions of the REECo Maintenance Compound during the Cold War and identifies contributing and noncontributing resources. The report defines a district boundary based on archival research and the field survey and concludes with an appendix that presents digital color images of the compound with descriptions and a map key showing image viewpoints and directions. Although none of the architectural resources are recommended individually eligible, the district evaluation concludes the REECo Maintenance Compound is eligible as a historic district for listing in the NRHP under the Secretary of the Interior’s Significance Criteria A and C at the local level. The historic district retains all seven aspects of integrity and conveys its significance under the abovementioned criteria.

138 kV↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries: Preprint

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$10 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Report Series: Finding of Effect, and Mitigation Documentation for Building 23-702, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-702 in the town of Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15278), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (see Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-702 was built in 1965 as a foil handling building for the Los Alamos Scientific Laboratory (LASL), who worked on the design and engineering of nuclear weapons and other nuclear experiments. The building appeared to have secondarily functioned as a storage for radioactive sources in the 1980s and 1990s. The building was operational until 2004, then deactivated sometime between 2005 and 2014. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-702 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al.) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-702 was also identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Non-parametric projections of the net-income distribution for all U.S. states for the Shared Socioeconomic Pathways

Abstract Income distributions are a growing area of interest in the examination of equity impacts brought on by climate change and its responses. Such impacts are especially important at subnational levels, but projections of income distributions at these levels are scarce. Here, we project U.S. state-level income distributions for the Shared Socioeconomic Pathways (SSPs). We apply a non-parametric approach, specifically a recently developed principal components algorithm to generate net income distributions for deciles across 50 U.S. states and the District of Columbia. We produce these projections to 2100 for three SSP scenarios in combination with varying projections of GDP per capita to represent a wide range of possible futures and uncertainties. In the generation of these scenarios, we also generated tax adjusted historical deciles by U.S. states, which we used for validating model performance. Our method thus produces income distributions by decile for each state, reflecting the variability in state income, population, and tax regimes. Our net income projections by decile can be used in both emissions- and impact-related research to understand distributional effects at various income levels and identify economically vulnerable populations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analyzing School Bus Electrification in Richmond, Virginia

School buses are an essential component of the transportation infrastructure, serving as a lifeline for students across the globe. However, the widespread use of diesel school buses has raised concerns about the health impact on millions of students exposed to harmful emissions daily. Recognizing this issue, school districts worldwide are urgently seeking cleaner energy alternatives. Electric school buses emerge as an environmentally friendly and sustainable option, fostering a healthier environment for both students and communities. However, school bus electrification faces the challenges of high upfront cost, cumbersome charging management, and constraints from power grids. To help school bus operators address those challenges, this study presents a data-driven analysis for school bus electrification. This study considered a real-world school bus system in Richmond, VA, and developed a mathematical programming model to analyze the system design, charging strategies, and charging load profiles for the electrification scenario. The study evaluated different charging strategies based on model outcomes, aiming to optimize efficiency and effectiveness. Ultimately, this research generated electric school bus charging demand profiles under various scenarios, shedding light on the feasibility and implications of transitioning to electric-powered school buses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Energy Approaches for Mixed-Use Developments in the Front Range Urban Corridor

The primary objective of the document is to present example technical approaches and strategies that planners and developers can reference for all-electric mixed-use developments in the Rocky Mountain Front Range urban corridor that are considering advanced energy performance goals such as high levels of energy efficiency and renewable integration. The strategies are tailored toward the vision for a zero energy, all-electric, district thermal system-connected starter district. In this example, on-site solar generation is emphasized as a strategy that can be combined with electrical and thermal energy storage for enhanced community resilience and demand flexibility. Opportunities for utilizing or adapting these strategies include: sharing with vertical developers for potential integration of strategies into vertical design guidelines; incorporation into Owner Project Requirements (OPRs); providing example strategies to design teams as a starting point for design; informing structure of agenda for a building design charrette; comparing building designs to example strategies at various points in the design process to evaluate design progression. While the technical strategies outlined in this document can help inform the development of guidelines for projects in the Front Range urban corridor, this document does not set requirements for any rating, certification, program, or policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical Education Teachers’ Representations of Their Training to Promote the Inclusion of Students with Disabilities

School inclusion is based on the need to adopt and implement a holistic view of education, training, and human development embodied in the idea of everyone, for everyone. In the context of Physical Education (PE), there are still several constraints to the realization of this universal desideratum. Among these, teacher training and qualification for the inclusion of students with Specific Health Needs (SHNs) stands out. That is, students with physical and mental health problems whose impact is significantly manifested in the learning process. Thus, the objective of this study was to identify the representations of PE teachers about their training to develop inclusive processes with students with SES. Participants in this study were 151 PE teachers from different regions and districts of Portugal (Algarve, Aveiro, Castelo Branco, Lisbon, Porto, and Viseu) who had 23.6 ± 8.1 years of teaching service. Teachers answered an online questionnaire, on the Google Forms platform, with open and closed questions about their education and training to develop inclusive processes in PE. The results indicate two significant dimensions: (1) initial training for teaching inclusive PE and (2) continuous training for inclusion. Regarding initial training, a large majority of the teachers under study, at the end of their initial training, did not have the essential skills to teach PE to students with SES. It was also identified that a large majority reported not having had any contact with students with SES throughout their training process for teaching. It was also recognized that this training was not adjusted to the development of intervention skills with students with SHN. Regarding continuous training, it was identified that attendance at this training increased their skills to teach PE to students with SHN. Workshops/actions/training courses are the main training models adopted. However, it is recognized that the training provided does not respond concretely to their training needs to intervene with students with SHN, since teachers essentially seek to improve intervention in the context of inclusive physical education. We conclude that teacher training for inclusion is not yet fully adjusted to the reality of the inclusive school paradigm. In this sense, in practical terms, the following are suggested: (1) the need for reinforcement in study plans with specific and long-term curricular units; (2) the introduction of real practice components in context; and (3) supervised pedagogical practice in diverse contexts.

Celestino, Tadeu (ORCID:0000000163087981)↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Multi-timescale operations of nuclear-renewable hybrid energy systems for reserve and thermal product provision

In this paper, an optimal operation strategy of a nuclear-renewable hybrid energy system (N-R HES), in conjunction with a district heating network, is developed within a comprehensive multi-timescale electricity market framework. The grid-connected N-R HES is simulated to explore the capabilities and benefits of N-R HES of providing energy products, different reserve products, and thermal products. An N-R HES optimization and control strategy is formulated to exploit the benefits from the hybrid energy system in terms of both energy and ancillary services. A case study is performed on the customized NREL-118 bus test system with high renewable penetrations, based on a multi-timescale (i.e., three-cycle) production cost model. Both day-ahead and real-time market clearing prices are determined from the market model simulation. In conclusion, the results show that the N-R HES can contribute to the reserve requirements and also meet the thermal load, thereby increasing the economic efficiency of N-R HES (with increased revenue ranging from 1.55% to 35.25% at certain cases) compared to the baseline case where reserve and thermal power exports are not optimized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

How Time Inefficient and Uncertain are Paratransit Trips Compared to Car Trips

The Americans with Disabilities Act (ADA) stipulates that paratransit mobility be comparable to public transit. However, with just under 5% of the population relying on public transportation, transit is not a representative benchmark. To highlight this inequality, we compare trip times by paratransit to counterfactual car-based travel. Using 2.5 years of demand data from the Denver Regional Transportation District's Access-a-Ride service, we compare paratransit trip times to counterfactual car-based trips for the same origin-destination pairs, controlling for various trip characteristics. Compared to car travel, the findings indicate high variability and uncertainty associated with paratransit trip times. For the same origin-destination pairs, the mean paratransit trip time is almost twice that of the mean car travel time, with a standard deviation for paratransit trip time fourfold that of the standard deviation for car trip time. For perspective, traveling an average of 10 mi during the 7-8 a.m. morning peak can take about 16 min by car with almost no variability, while that same trip can take an average of 25 min by paratransit, with 5% of trips being outside the 95% confidence interval and thus unpredictable. Paratransit trip time inefficiency tends to be particularly worse for females; older adults; those making trips between 9 and 11 a.m.; cash-paying customers; those making shorter trips; and those traveling during inclement weather, including cold temperatures. These findings suggest a need to re-assess using public transit as a benchmark for paratransit supply as regulated by the ADA.

accessible transportation and mobility↗

Catalina Repower Feasibility Study: NREL Phases I & II Summary Report

Engineers at the National Renewable Energy Laboratory (NREL) supported Southern California Edison (SCE) and the United States Environmental Protection Agency (EPA) by conducting technical and economic analyses for energy systems at Santa Catalina (Catalina) Island, which is located 22 miles off the coast of Long Beach, California. This effort was part of a broader Repower Catalina Feasibility Study that was also supported by NV5, an engineering consulting firm and project partner to NREL for this analysis. This document describes NREL’s techno-economic modeling and optimization analysis for the first two phases of this project which focus on supply-side generation and energy storage options for Catalina. SCE’s goal for this analysis is to determine a strategy for electricity generation on Catalina Island that results in lower energy costs, improved energy resiliency, and reduced air emissions. EPA goals for this effort are to reduce emissions of air pollution and encourage renewable energy development on contaminated and formerly contaminated lands when such development is aligned with the community’s vision for the site. Currently, an on-island SCE power plant serves the Catalina Island electrical load with 6 reciprocating diesel generators totaling 9.4 MW; 23 propane-fueled microturbines totaling 1.5 MW; and a 1-MW, 7.2-MWh sodium sulfur battery energy storage system (BESS). In 2017, the electricity consumption on the island was 29.1 GWh, with an average load of 3.3 MW and peak load of approximately 5.5 MW. Considering new environmental standards on diesel generator emissions from California’s South Coast Air Quality Management District, a 60% renewable energy target for 2030 laid out in California’s Senate Bill 100, SCE’s Clean Power Electrification Pathway, and the characteristics of the island’s existing diesel generators, SCE is seeking to evaluate the technical and economic implications of different energy technology options to determine a path forward. Phases I and II of the Repower Catalina Feasibility Study, summarized in this document, evaluated the following: Interconnection with the mainland via an undersea cable; On-island fossil fuel generation, including diesel, propane, and/or liquified natural gas (LNG); On-island renewable energy (RE) technologies, including solar photovoltaics (PV), wind turbines, and wave energy devices; BESS to support the above generation technologies; Initial analysis of the potential impacts of implementing energy efficiency measures. Results indicate strong techno-economic potential for a mix of on-island diesel and/or propane generators, solar PV, BESS, and energy efficiency measures to help SCE and Catalina achieve their goals compliant with California’s emissions and clean energy standards while minimizing electricity life cycle costs (LCC) over the 30-year analysis period. This document summarizes the considerations and findings of Phases I and II, focusing on high-level takeaways from Phase I and more detailed results from Phase II, and discusses a potential path forward for Phase III.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Resilience Options for the Koolauloa Community Resilience Hub – Energy Technology Innovation Partnership Project, Cohort 2: Summary of Findings and Assessment

Hui o Hau‘ula (HoH) is a community organization dedicated to the well-being of the population of the Ko‘olauloa district on the Hawaiian island of Oahu. In response to growing concerns about challenges related to extreme weather events or natural disasters, HoH formulated the concept of the Ko‘olauloa Community Resilience Hub, or KCRH. The KCRH facility would serve as a focal point for the community during normal conditions, while also providing essential services and acting as a safe space during emergencies, natural or man-made. The concept of the KCRH was initially developed in partnership with the Hawaii Natural Energy Institute, +Lab Architects, and the City and County of Honolulu. In the fall of 2023, the U.S. Department of Energy, under the Energy Technology Innovation Partnership Project Program (ETIPP), provided support to the KCRH project, in the form of technical assistance (TA) to be provided by its National Laboratory complex. In this case, the core TA was provided by Sandia National Laboratories, and it was directed to providing options for designing an energy system based at the KCRH that could support critical loads in the event of a 30- day grid outage. The National Renewable Energy Laboratory (NREL) provided communications and logistics support in the project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ICE Calculator 2: Final Report for Phase 1 and 2 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

ICE 2.0 Phase 2 Final Report In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE Calculator 2 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE Calculator 2 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 and 2 of the ICE Calculator 2 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 2 was sponsored by six utilities: Empire District Electric Company, Evergy Missouri, Pacific Gas & Electric, San Diego Gas & Electric, Southern California Edison, and Union Electric. Phase 1 and 2 involved 15 customer interruption cost survey activities representing a total of 30 electricity distribution service territories. ICE Calculator Version 2.0 and 2.2 Comparison This memorandum describes–at a high-level–the improvements in interruption cost estimates for the version 2.2 of the ICE Calculator (released February 2026) compared to version 2.0 (released in April 2025). Version 2.2 of the ICE Calculator corresponds to Phase 2 of the initiative, while version 2.0 corresponds to Phase 1. The improvements in version 2.2 result from both a significant increase in the number of customer responses that have been collected and the identification of seven additional factors that help estimate customer interruption costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gasification of Coal and Biomass: The Route to Net-Negative-Carbon Power and Hydrogen

One promising process that is a candidate for meeting the goals of the US Department of Energy’s 21st Century Power Plant initiative is to gasify a mixture of coal and biomass to yield a syngas, which can have CO2 removed and then be used to produce hydrogen as well as an off-gas that can be used to flexibly produce power. This concept would overall be carbon net-negative and readily meet the 21st Century Power Plant initiative targets of smaller scale MW generation, high ramp rates and turndown, feedstock flexibility, and high efficiency—at a reasonable cost. Moreover, adding the large-scale production of “ultra-green” hydrogen yields a system tailored for the coming hydrogen economy, providing long-term energy storage and an attractive co-product for sale. The objective of the work being led by the Electric Power Research Institute, Inc. (EPRI), with support by Bechtel Corporation (Bechtel), Gas Technology Institute (GTI), Hamilton Mauer International, Inc. (HMI), Nebraska Public Power District (NPPD), NexantECA, Inc. (Nexant), and Wärtsilä, is to perform a front-end design and engineering (FEED) study on an oxygen-blown gasification system coupled with water-gas shift, pre-combustion CO2 capture, and pressure-swing adsorption working off a coal/biomass mix to yield high-purity hydrogen and a fuel off-gas that can generate power. Several designs are being considered that will be capable of producing 50 MW net from a flexible generator, over 8500 kg/hr of hydrogen, and net-negative CO2 emissions, at an efficiency of 50% net HHV. The plant would be hosted at an NPPD site, where opportunities for enhanced oil recovery and sequestration have been investigated and the need for low-carbon power and hydrogen is imminent. The principal biomass to be used is corn stover—prevalent in Nebraska where the plant will be located—mixed with Powder River Basin (PRB) coal, necessitating a gasifier that can use this feedstock and be flexible to allow other types. Waste plastics will also be reviewed for use. Two oxygen-blown gasifiers have been identified as candidates that have done testing with biomass including corn stover: the GTI gasifier—a high-pressure, fluidized-bed type—and HMI’s, a lower pressure moving-bed type. Both have relative advantages that were investigated in the Phase I design study, with a resultant down select of one system for which the FEED will be performed in Phase II. The technical tasks for the project are: • Design Development: Completion of design activities necessary to provide inputs for the FEED study. Multiple design cases will be assessed with the selection of the optimal one for the FEED. • Investment Case Preparation: Development of the draft investment case for the proposed process with business cases performed for the proposed host site and two other locations. • Host Site Selection: Evaluation of the two potential host sites within NPPD’s portfolio to select the preferred candidate based on technical, economic, and environmental considerations. • Environmental Information Volume (EIV) Development: Completion of the EIV for the host site. • FEED Study: Completion of a FEED study based on the design selected in Phase I. A Greenhouse Gas Life Cycle Analysis will also be performed for the process. • Update Investment Case: Finalization of the investment case based on findings from the FEED. The advantages of the proposed project are significant. Having an engaged U.S. power utility willing to provide a host site that will produce energy from coal plus a deep and experienced team is critical; the process meets all the goals of DOE’s 21st Century Power Plant initiative at an estimated total plant cost of ~$880M and a production cost of hydrogen of ~$2/kg-H2 while producing net-negative carbon power. If developed, this process has real commercial potential in the United States—supported by EPRI’s initial review of the considerable interest from selected U.S. utilities—and elsewhere around the globe. The process has fewer environmental hurdles compared to other concepts, lowering regulatory and protest risks—providing a pathway to preserving the viability of a critical indigenous energy source by transforming its use to match a changing world. This presentation outlines the motivation for the effort, summarizes project plans, work completed to date, results of the Phase I effort and, and detailed work scope for the remainder of the project in the Phase II FEED effort.

01 COAL, LIGNITE, AND PEAT↗