Dispersion of sound in a combustion duct by fuel droplets and soot particles

Dispersion and attenuation of acoustic plane wave disturbances propagating in a ducted combustion system are studied. The dispersion and attenuation are caused by fuel droplet and soot emissions from a jet engine combustor. The attenuation and dispersion are due to heat transfer and mass transfer and viscous drag forces between the emissions and the ambient gas. Theoretical calculations show sound propagation at speeds below the isentropic speed of sound at low frequencies. Experimental results are in good agreement with the theory.

Miles, J. H.↗

Dispersion of sound in a combustion duct by fuel droplets and soot particles

Dispersion and attenuation of acoustic plane wave disturbances propagating in a ducted combustion system are studied. The dispersion and attenuation are caused by fuel droplet and soot emissions from a jet engine combustor. The attenuation and dispersion are due to heat transfer and mass transfer and viscous drag forces between the emissions and the ambient gas. Theoretical calculations show sound propagation at speeds below the isentropic speed of sound at low frequencies. Experimental results are in good agreement with the theory.

Miles, J. H.↗

Sound radiation from annular ducts/nozzles using modal decomposition of in-duct acoustic power

Using a refined acoustic impulse technique, an experimental program was carried out to determine the proper procedure for measuring the acoustic power for both incident and reflected sound fields for annular ducts with and without nozzles at various flow conditions. Several radial and azimuthal pressure measurements were made, and using these complex pressure data, the modal content of the pressure field was determined. A mathematical approach for the modal decomposition of annular duct acoustic power was developed. The acoustic power due to each individual mode and also their total sum were derived. The acoustic characteristics of annular duct-nozzle systems were studied at various flow conditions. The results derived from the experiments include the termination reflection coefficient, the normalized transmission coefficients, the power transfer functions and the power imbalance.

Salikuddin, M.↗

A theoretical model for the cross spectra between pressure and temperature downstream of a combustor

A theoretical model developed to calculate pressure-temperature cross spectra, pressure spectra, temperature spectra and pressure cross spectra in a ducted combustion system is presented. The model assumes the presence of a fluctuating-volumetric-heat-release-rate disk source and takes into account the spatial distribution of the steady-state volumetric-heat flux. Using the model, pressure, velocity, and temperature perturbation relationships can be obtained. The theoretical results show that, at a given air mass flow rate, the calculated pressure-temperature cross spectra phase angle at the combustor exit depends on the model selected for the steady-state volumetric-heat flux in the combustor. Using measurements of the phase angle, an appropriate source region model was selected. The model calculations are compared with the data. The comparison shows good agreement and indicates that with the use of this model the pressure-temperature cross spectra measurements provide useful information on the physical mechanisms active at the combustion noise source.

Miles, J. H.↗

An experimental evaluation of S-duct inlet-diffuser configurations for turboprop offset gearbox applications

A test program, utilizing a large scale model, was run in the NASA Lewis Research Center 10- by 10-ft wind tunnel to examine the influence on performance of design parameters of turboprop S-duct inlet/diffuser systems. The parametric test program investigated inlet lip thickness, inlet/diffuser cross-sectional geometry, throat design Mach number, and shaft fairing shape. The test program was run at angles of attack to 15 deg and tunnel Mach numbers to 0.35. Results of the program indicate that current design techniques can be used to design inlet/diffuser systems with acceptable total pressure recovery, but several of the design parameters, notably lip thickness (contraction ratio) and shaft fairing cross section, must be optimized to prevent excessive distortion at the compressor face.

Mcdill, Paul L.↗

Advanced liquid oxygen (LO2) propellant conditioning concept testing

Advanced methods of liquid oxygen (LO2) propellant conditioning were studied as part of an effort for increasing reliability and operability while reducing cost of future heavy lift launch vehicles. The most promising conditioning concept evaluated was no-bleed (passive recirculation) followed by low-bleed, helium injection, and use of a recirculation line. Full-scale cryogenic testing was performed with a sloped feedline test article to validate models of behavior of LO2 in the feedline and to prove no-bleed feasibility. Test data are also intended to help generate design guidelines for the development of a main propulsion system feed duct. A design-of-experiments matrix of over 100 tests was developed to test all four propellant conditioning concepts and the impact of design parameters on the concepts. Liquid nitrogen was used as the test fluid. The work for this project was conducted from October 1992 through January 1994 at the hydrogen cold flow facility of the west test area of MSFC. Test data have shown that satisfactory temperatures are being obtained for the no-bleed conditioning concept.

Perry, G. L. E.↗

International Space Station Common Cabin Air Assembly Condensing Heat Exchanger Hydrophilic Coating Failures and Lessons Learned

The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within in the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings and potential remediation techniques will also be discussed.

Balistreri, Steven F.↗

International Space Station Common Cabin Air Assembly Condensing Heat Exchanger Hydrophilic Coating Operation, Recovery, and Lessons Learned

The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX in the ISS segments, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the ISS cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings as well as remediation and recovery of the full heat exchanger will be discussed.

Balistreri, Steven F.↗

NASA’s Quiet Electric ENgines (QUEEN): Thermal Analysis and Testing of the Electronic Speed Controller (ESC)

An electric ducted fan system was tested at the NASA Glenn Research Center. Main components of the system include a commercial-off-the-Shelf (COTS) fan and motor, electronic speed controller, and cooling system. Motor speed, voltage, current, and temperatures were measured in this static ground test of the propulsor. The thermal performance of the Electronic Speed Controller (ESC) was also measured using two different methods to cool the ESC: air cooling and cold plate cooling. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Single Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large regional single-aisle aircraft. Lessons learned will be used to guide development of future QUEEN prototypes and thermal management systems.

Firas G Asfoor↗

Automated Alignment And Inspection Of Duct Welds

Machine vision system being developed for use in aligning ends of two round ducts before welding ends together and inspecting welded ducts for alignment after welding. System makes consistent, objective measurements quickly. Improves quality and reliability of welds, reduces need for rework, and reduces alignment and inspection time, thereby reducing cost of manufacture.

Cross, George S.↗

Design and development of the combustor inlet diffuser for the NASA/GE energy efficient engine

Results of an experimental investigation of the aerodynamic performance of a split duct annular combustor inlet diffuser system are presented. Several diffuser configurations were investigated in 3X-scale water table tests and the preferred design was evaluated in full-scale annular airflow model tests. Pressure recovery and flow losses were determined as a function of prediffuser inlet velocity profile, flow extraction at the prediffuser exit, and distribution of flow in the combustor. Inlet velocity profile and turbulence levels were found to have a pronounced effect on system performance. Flow extraction at the prediffuser exit was found to have little influence on system performance. Generally, the annular split duct diffuser system was found to satisfy the performance objectives for the engine.

Sabla, P. E.↗

Drive turbine systems for 20-inch turbofan simulators. 1: Duct turbine design

A study was made to evolve the turbine drive systems for 20-inch turbofan engine simulators. The fan designs used in the simulators included single-stage and two-stage configurations that covered a wide range of rotative speed and power requirement. The objective assumed for the study was to evolve one core turbine design that could drive all of the single-stage fans and, when operated in combination with one duct turbine design, drive all of the two-stage fans. The duct turbine power output is then needed to determine the make-up power required of the core turbine over the range of two-stage fan operating conditions. The duct turbine design analysis is reported and includes the selection of the duct turbine velocity diagram, a description of the blade design, and a determination of its off-design performance. Adjustable stators were found to be quite advantageous to the duct turbine off-design operation. The use of adjustable stators enabled the duct turbine to accommodate fan mass flow at all operating points and caused the duct turbine power output to increase as the total power requirement increased. This in turn resulted in a core turbine make-up power requirement that was not significantly greater than that required for driving the single-stage fans.

Whitney, W. J.↗

Aero-acoustic tests of duct-burning turbofan exhaust nozzles

The acoustic and aerodynamic characteristics of several exhaust systems suitable for duct burning turbofan engines are evaluated. Scale models representing unsuppressed coannular exhaust systems are examined statically under varying exhaust conditions. Ejectors with both hardwall and acoustically treated inserts are investigated.

Kozlowski, H.↗

Lightweight Valve Closes Duct Quickly

Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

Fournier, Walter L.↗

Composite load spectra for select space propulsion structural components

The objective of this program is to develop generic load models with multiple levels of progressive sophistication to simulate the composite (combined) load spectra that are induced in space propulsion system components, representative of Space Shuttle Main Engines (SSME), such as transfer ducts, turbine blades, and liquid oxygen posts and system ducting. The first approach will consist of using state of the art probabilistic methods to describe the individual loading conditions and combinations of these loading conditions to synthesize the composite load spectra simulation. The second approach will consist of developing coupled models for composite load spectra simulation which combine the deterministic models for composite load dynamic, acoustic, high pressure, and high rotational speed, etc., load simulation using statistically varying coefficients. These coefficients will then be determined using advanced probabilistic simulation methods with and without strategically selected experimental data.

Newell, J. F.↗

Composite load spectra for select space propulsion structural components

The objective of this program is to develop generic load models with multiple levels of progressive sophistication to simulate the composite load spectra that are induced in space propulsion system components, representative of Space Shuttle Main Engines (SSME), such as transfer ducts, turbine blades, and liquid oxygen (LOX) posts and system ducting. These models will be developed using two independent approaches. The first approach consists of using state-of-the-art probabilistic methods to describe the individual loading conditions and combinations of these loading conditions to synthesize the composite load spectra simulation. The methodology required to combine the various individual load simulation models (hot-gas dynamic, vibrations, instantaneous position, centrifugal field, etc.) into composite load spectra simulation models will be developed under this program. A computer code incorporating the various individual and composite load spectra models will be developed to construct the specific load model desired. The second approach, which is covered under the options portion of the contract, will consist of developing coupled models for composite load spectra simulation which combine the (deterministic) models for composite load dynamic, acoustic, high-pressure and high rotational speed, etc., load simulation using statistically varying coefficients. These coefficients will then be determined using advanced probabilistic simulation methods with and without strategically selected experimental data. This report covers the efforts of the third year of the contract. The overall program status is that the turbine blade loads have been completed and implemented. The transfer duct loads are defined and are being implemented. The thermal loads for all components are defined and coding is being developed. A dynamic pressure load model is under development. The parallel work on the probabilistic methodology is essentially completed. The overall effort is being integrated in an expert system code specifically developed for this project.

Newell, J. F.↗

The effects of air leaks on solar air heating systems

This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

Elkin, R.↗