Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Allosteric nanobodies reveal the dynamic range and diverse mechanisms of G-protein-coupled receptor activation

G-protein-coupled receptors (GPCRs) modulate many physiological processes by transducing a variety of extracellular cues into intracellular responses. Ligand binding to an extracellular orthosteric pocket propagates conformational change to the receptor cytosolic region to promote binding and activation of downstream signalling effectors such as G proteins and β-arrestins. It is well known that different agonists can share the same binding pocket but evoke unique receptor conformations leading to a wide range of downstream responses (‘efficacy’). Furthermore, increasing biophysical evidence, primarily using the β 2 -adrenergic receptor (β 2 AR) as a model system, supports the existence of multiple active and inactive conformational states. However, how agonists with varying efficacy modulate these receptor states to initiate cellular responses is not well understood. Here we report stabilization of two distinct β 2 AR conformations using single domain camelid antibodies (nanobodies)—a previously described positive allosteric nanobody (Nb80) and a newly identified negative allosteric nanobody (Nb60). We show that Nb60 stabilizes a previously unappreciated low-affinity receptor state which corresponds to one of two inactive receptor conformations as delineated by X-ray crystallography and NMR spectroscopy. Furthermore, we find that the agonist isoprenaline has a 15,000-fold higher affinity for β 2 AR in the presence of Nb80 compared to the affinity of isoprenaline for βA 2 R in the presence of Nb60, highlighting the full allosteric range of a GPCR. Assessing the binding of 17 ligands of varying efficacy to the β 2 AR in the absence and presence of Nb60 or Nb80 reveals large ligand-specific effects that can only be explained using an allosteric model which assumes equilibrium amongst at least three receptor states. Agonists generally exert efficacy by stabilizing the active Nb80-stabilized receptor state (R 80 ). In contrast, for a number of partial agonists, both stabilization of R80 and destabilization of the inactive, Nb60-bound state (R 60 ) contribute to their ability to modulate receptor activation. These data demonstrate that ligands can initiate a wide range of cellular responses by differentially stabilizing multiple receptor states.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-mode humidity sensing with water-soluble copper phthalocyanine for increased sensitivity and dynamic range

Aqueous solubility of copper phthalocyanine-3,4',4',4"'-tetrasulfonic acid tetrasodium salt (CuPcTs) enables fabrication of flexible electronic devices by low cost inkjet printing. We (1) investigate water adsorption kinetics on CuPcTs for better understanding the effects of relative humidity (RH) on hydrophilic phthalocyanines, and (2) assess CuPcTs as a humidity-sensing material. Reaction models show that H 2 O undergoes 2-site adsorption which can be represented by a pair of sequentially-occurring pseudo-first order reactions. Using high frequency (300–700 THz) and low frequency (1–8 MHz) dielectric spectroscopy combined with gravimetric measurements and principal component analysis, we observe that significant opto-electrical changes in CuPcTs occur at RH ≈ 60%. The results suggest that rapid H 2 O adsorption takes place at hydrophilic sulfonyl/salt groups on domain surfaces at low RH, while slow adsorption and diffusion of H 2 O into CuPcTs crystallites leads to a mixed CuPcTs-H 2 O phase at RH > 60%, resulting in high frequency dielectric screening of the film by water and dissociation of Na+ from CuPc(SO 3 -) 4 ions. Lastly, the CuPcTs-H 2 O interaction can be tracked using a combination of gravimetric, optical, and electrical sensing modes, enabling accurate ( ± 2.5%) sensing in the ~0–95% RH range with a detection limit of less than 0.1% RH.

36 MATERIALS SCIENCE↗

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high dynamic range data acquisition system for a solid-state electron electric dipole moment experiment

We have built a high precision (24-bit) data acquisition (DAQ) system capable of simultaneously sampling eight input channels for the measurement of the electric dipole moment of the electron. The DAQ system consists of two main components: a master board for DAQ control and eight individual analog-to-digital converter (ADC) boards for signal processing. This custom DAQ system provides galvanic isolation of the ADC boards from each other and the master board using fiber optic communication to reduce the possibility of ground loop pickup and attain ultimate low levels of channel cross-talk. In this paper, we describe the implementation of the DAQ system and scrutinize its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH DYNAMIC RANGE IMAGES OF THE SOLAR CORONA BETWEEN 150 AND 450 MHz

We present radio images of the quiet Sun obtained with the Nancay Radioheliograph between 150 and 450 MHz, using the latest improvements in the instrument and in the data processing techniques. We emphasize new aspects of the corona observable in this frequency range, particularly the prominence of coronal holes, and discuss implications for future studies.

99 GENERAL AND MISCELLANEOUS↗

Characterisation of the high dynamic range Large Pixel Detector (LPD) and its use at X-ray free electron laser sources

The STFC Rutherford Appleton Laboratory have delivered the Large Pixel Detector (LPD) for MHz frame rate imaging at the European XFEL. The detector system has an active area of 0.5 m × 0.5 m and consists of a million pixels on a 500 μm pitch. Sensors have been produced from 500 μm thick Hammamatsu silicon tiles that have been bump bonded to the readout ASIC using a silver epoxy and gold stud technique. Each pixel of the detector system is capable of measuring 10 5 12 keV photons per image readout at 4.5 MHz. In this paper results from the testing of these detectors at the Diamond Light Source and the Linac Coherent Light Source (LCLS) are presented. As a result, the performance of the detector in terms of linearity, spatial uniformity and the performance of the different ASIC gain stages is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

Analysis of Pulse Replicators for High-Bandwidth, High-Dynamic-Range, Single-Shot Optical Characterization

Optical pulse replicators generate multiple replicas of an optical waveform that are averaged to increase the signal-to-noise ratio of single-shot, high-bandwidth temporal measurements. Processing a replicated waveform requires that the delayed realizations of the waveform under test be retimed properly before averaging. Delay miscalibration significantly reduces the measurement bandwidth. Processing algorithms based on edge alignment, centroid matching, and minimization of the distance between replicas decrease the impact of the detrimental bandwidth reduction, and a global distance minimization, simultaneously taking into account the distance between all pairs of retimed replicas, has the best performance, even in the presence of significant measurement noise. The general impact of chromatic dispersion on the averaged waveform is derived in the framework of the temporal transport-of-intensity equation, and the measurement error is quantified for various optical signals.

Dispersion, fiber optics, frequency response, opti↗