Search NASA⌕ Search

SEARCH · Search NASA

Results for “ears”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Radiation and Risk of Liver, Biliary Tract, and Pancreatic Cancers among Atomic Bomb Survivors in Hiroshima and Nagasaki: 1958–2009

The Life Span Study (LSS) of atomic bomb survivors has consistently demonstrated significant excess radiation-related risks of liver cancer since the first cancer incidence report. Here, we present updated information on radiation risks of liver, biliary tract and pancreatic cancers based on 11 additional years of follow-up since the last report, from 1958 to 2009. The current analyses used improved individual radiation doses and accounted for the effects of alcohol consumption, smoking and body mass index. The study participants included 105,444 LSS participants with known individual radiation dose and no known history of cancer at the start of follow-up. Cases were the first primary incident cancers of the liver (including intrahepatic bile duct), biliary tract (gallbladder and other and unspecified parts of biliary tract) or pancreas identified through linkage with population-based cancer registries in Hiroshima and Nagasaki. Poisson regression methods were used to estimate excess relative risks (ERRs) and excess absolute risks (EARs) associated with DS02R1 doses for liver (liver and biliary tract cancers) or pancreas (pancreatic cancer). We identified 2,016 incident liver cancer cases during the follow-up period. Radiation dose was significantly associated with liver cancer risk (ERR per Gy: 0.53, 95% CI: 0.23 to 0.89; EAR per 10,000 person-year Gy: 5.32, 95% CI: 2.49 to 8.51). There was no evidence for curvature in the radiation dose response (P=0.344). ERRs by age-at-exposure categories were significantly increased among those who were exposed at 0–9, 10–19 and 20–29 years, but not significantly increased after age 30 years, although there was no statistical evidence of heterogeneity in these ERRs (P = 0.378). The radiation ERRs were not affected by adjustment for smoking, alcohol consumption or body mass index. As in previously reported studies, radiation dose was not associated with risk of biliary tract cancer (ERR per Gy: –0.02, 95% CI: –0.25 to 0.30). Radiation dose was associated with a nonsignificant increase in pancreatic cancer risk (ERR per Gy: 0.38, 95% CI: <0 to 0.83). The increased risk was statistically significant among women (ERR per Gy: 0.70, 95% CI: 0.12 to 1.45), but not among men.

60 APPLIED LIFE SCIENCES↗

Low Dose Ionizing Radiation Modulates Immune Function

In order to examine the effects of low dose ionizing radiation on the immune system we chose to examine an amplified adaptive cellular immunity response. This response is Type IV delayed-type hypersensitivity also called contact hypersensitivity. The agent fluorescein isothiocyanate (FITC) is a low molecular weight, lipophilic, reactive, fluorescent molecule that can be applied to the skin where it (hapten) reacts with proteins (carriers) to become a complete antigen. Exposure to FITC leads to sensitization which is easily measured as a hypersensitivity inflammatory reaction following a subsequent exposure to the ear. Ear swelling, eosinophil infiltration, immunoglobulin E production and cytokine secretion patterns characteristic of a “Th2 polarized” immune response are the components of the reaction. The reaction requires successful implementation of antigen processing and presentation by antigen presenting Langerhans cells, communication with naïve T lymphocytes in draining lymph nodes, expansion of activated T cell clones, migration of activated T cells to the circulation, and recruitment of memory T cells, macrophages and eosinophils to the site of the secondary challenge. Using this model our approach was to quantify system function rather than relying only on indirect biomarkers of cell. We measured the FITC-induced hypersensitivity reaction over a range of doses from 2 cGy to 2 Gy. Irradiations were performed during key events or prior to key events to deplete critical cell populations. In addition to quantifying the final inflammatory response, we assessed cell populations in peripheral blood and spleen, cytokine signatures, IgE levels and expression of genes associated with key processes in sensitization and elicitation/recall. We hypothesized that ionizing radiation would produce a biphasic effect on immune system function resulting in an enhancement at low doses and a depression at higher doses and suggested that this transition would occur in the dose range of 5 to 50 cGy.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Pericytes control vascular stability and auditory spiral ganglion neuron survival

The inner ear has a rich population of pericytes, a multi-functional mural cell essential for sensory hair cell heath and normal hearing. However, the mechanics of how pericytes contribute to the homeostasis of the auditory vascular-neuronal complex in the spiral ganglion are not yet known. In this study, using an inducible and conditional pericyte depletion mouse (PDGFRB-CreER T2 ; ROSA26iDTR) model, we demonstrate, for the first time, that pericyte depletion causes loss of vascular volume and spiral ganglion neurons (SGNs) and adversely affects hearing sensitivity. Using an in vitro trans-well co-culture system, we show pericytes markedly promote neurite and vascular branch growth in neonatal SGN explants and adult SGNs. The pericyte-controlled neural growth is strongly mediated by pericyte-released exosomes containing vascular endothelial growth factor-A (VEGF-A). Treatment of neonatal SGN explants or adult SGNs with pericyte-derived exosomes significantly enhances angiogenesis, SGN survival, and neurite growth, all of which were inhibited by a selective blocker of VEGF receptor 2 (Flk1). Our study demonstrates that pericytes in the adult ear are critical for vascular stability and SGN health. Cross-talk between pericytes and SGNs via exosomes is essential for neuronal and vascular health and normal hearing.

59 BASIC BIOLOGICAL SCIENCES↗

Electronic dummy for acoustical testing

Electronic Dummy /ED/ used for acoustical testing represents the average male torso from the Xiphoid process upward and includes an acoustic replica of the human head. This head simulates natural flesh, and has an artificial voice and artificial ears that measure sound pressures at the eardrum or the entrance to the ear canal.

Bauer, B. B.↗

Human operator dynamics for aural compensatory tracking

The human operator's ability to control using aural information only and using combined aural and visual displays was investigated for a simple tracking task. Tracking error was presented to the test subjects using one- and two-ear displays. For both displays the pitch of the tone represented the magnitude of the tracking error. The operator's aural control characteristics were modeled as a describing function plus a remnant. The effects on the measured describing function and remnant of different system dynamics, changes in the frequency content of the input and different displays were determined during the study. The describing function and remnant data indicate that humans can control as well with aural cues as with visual cues for the task considered. However, the reduction in operator time delays, expected because of the generally faster human response to aural stimuli, was not evident in the results. It was also determined that the operators could control equally well with either the one- or two-ear display.

Vinje, E. W.↗

Studies on Auditory and Vestibular End Organs and Brain Stem Nuclei

Cats were exposed to tones of 125, 1000, 2000, and 4000 Hz at sound pressure levels in the range 120 to 157.5 db, and for durations of one hour (1000, 2000, 4000 Hz) or four hours (125 Hz). Pure tone audiograms were obtained for each animal before and after exposure. Cochleas of animals were examined by phase-contrast microscopy. Extent of inner ear damage and range of frequencies for which hearing loss occurred increased as exposure tone was decreased in frequency. For example, exposure to 4000 Hz produced damage in a restricted region of the cochlea and hearing loss for a relatively narrow range of frequencies; exposure to 125 Hz produced wide-spread inner ear damage and hearing loss throughout the frequency range 125 to 6000 Hz.

Ades, H. W.↗

Loudness enhancement: Monaural, binaural and dichotic

It is shown that when one tone burst precedes another by 100 msec variations in the intensity of the first systematically influences the loudness of second. When the first burst is more intense than the second, the second is increased and when the first burst is less intense, the loudness of the second is decreased. This occurs in monaural, binaural and dichotic paradigms of signal presentation. Where both bursts are presented to the same ear there is more enhancement with less intersubject variability than when they are presented to different ears. Monaural enhancements as large as 30 db can readily be demonstrated, but decrements rarely exceed 5 db. Possible physiological mechanisms are discussed for this loudness enhancement, which apparently shares certain characteristics with time-order-error, assimilation, and temporal partial masking experiments.

Elmasian, R. O.↗

Loudness enhancement - Monaural, binaural, and dichotic

When one tone burst (T) precedes another (S) by 100 msec, variations in the intensity of T systematically influence the loudness of S. When T is more intense than S, S is increased; and when T is less intense, S loudness is decreased. This occurs in monaural, binaural, and dichotic paradigms of signal presentation. When T and S are presented to the same ear (monaural or binaural), there is more enhancement with less intersubject variability than when they are presented to different ears (dichotic paradigm). Monaural enhancements as large as 30 dB can readily be demonstrated, but decrements rarely exceed 5 dB. Possible physiological mechanisms are discussed for this loudness enhancement, which apparently shares certain characteristics with time-order error, assimilation, and temporal partial masking experiments.

Elmasian, R.↗

Electrochemical air revitalization system optimization investigation

A program to characterize a Breadboard of an Electrochemical Air Revitalization System (BEARS) was successfully completed. The BEARS is composed of three components: (1) a water vapor electrolysis module (WVEM) for O2 production and partial humidity control, (2) an electrochemical depolarized carbon dioxide concentrator module (EDCM) for CO2 control, and (3) a power-sharing controller, designed to utilize the power produced by the EDCM to partially offset the WVEM power requirements. It is concluded from the results of this work that the concept of electrochemical air revitalization with power-sharing is a viable solution to the problem of providing a localized topping force for O2 generation, CO2 removal and partial humidity control aboard manned spacecraft. Continued development of the EARS concept is recommended, applying the operational experience and limits identified during the BEARS program to testing of a one-man capacity system and toward the development of advanced system controls to optimize EARS operation for given interfaces and requirements. Successful completion of this development will produce timely technology necessary to plan future advanced environmental control and life support system programs and experiments.

Woods, R. R.↗

Selective attention and the auditory vertex potential. I - Effects of stimulus delivery rate. II - Effects of signal intensity and masking noise

The effects of varying the rate of delivery of dichotic tone pip stimuli on selective attention measured by evoked-potential amplitudes and signal detectability scores were studied. The subjects attended to one channel (ear) of tones, ignored the other, and pressed a button whenever occasional targets - tones of a slightly higher pitch were detected in the attended ear. Under separate conditions, randomized interstimulus intervals were short, medium, and long. Another study compared the effects of attention on the N1 component of the auditory evoked potential for tone pips presented alone and when white noise was added to make the tones barely above detectability threshold in a three-channel listening task. Major conclusions are that (1) N1 is enlarged to stimuli in an attended channel only in the short interstimulus interval condition (averaging 350 msec), (2) N1 and P3 are related to different modes of selective attention, and (3) attention selectivity in multichannel listening task is greater when tones are faint and/or difficult to detect.

Schwent, V. L.↗

JPL noise control program

Exposures of personnel to noise pollution at the Jet Propulsion Laboratories, Pasadena, California, were investigated. As a result of the study several protective measures were taken: (1) employees exposed to noise hazards were required to wear ear-protection devices, (2) mufflers and air diversion devices were installed around the wind tunnels; and (3) all personnel that are required to wear ear protection are given annual audimeter tests.

Klascius, A. F.↗

An active noise reduction system for aircrew helmets

An active noise reduction system was developed for use in aircrew flying helmets in which the acoustic noise field inside the ear defender is detected using a miniature microphone and an antiphase signal is fed back to a communications telephone within the ear defender. Performance of the active noise reduction system in a laboratory trial simulating flight conditions is shown to be satisfactory.

Wheeler, P. D.↗

Alleviation of pressure pulse effects for trains entering tunnels. Volume 1: Summary

The degree to which it is possible to attenuate the effects of pressure pulses on the passengers in trains entering tunnels by modifying the normally abrupt portal of a constant-diameter single track tunnel was investigated. Although the suggested modifications to the tunnel entrance portal may not appreciably decrease the magnitude of the pressure rise, they are very effective in reducing the discomfort to the human ear by substantially decreasing the rate of pressure rise to that which the normal ear can accommodate. Qualitative comparison was made of this portal modification approach with other approaches: decreasing the train speed or sealing the cars. The optimum approach, which is dependent upon the conditions and requirements of each particular rail system, is likely to be the portal modification one for a rapid rail mass transit system.

Dayman, B., Jr.↗

Solar rotation measurements at Mount Wilson. I - Analysis and instrumental effects

We examine the background velocity fields of the sun as observed at Mount Wilson. The method of velocity reduction of the full-disk Mount Wilson data is outlined. We describe a number of tests that have been carried out in order to find an instrumental origin for short-term rotation variations and a large-scale background line-shift - the ears. No instrumental cause can be found for this ear effect, although such a cause cannot yet be ruled out.

Howard, R.↗

Role of a decrease in body heat content in the thermoregulatory reaction of the concha auriculae vessels

At the constant ambient temperature 28-30 C the rabbit ear vessels were dilated and their temperature was 34.8/0.1 C. Administration of the 23-29 C water into the stomach entailed thermoregulatory construction of the ear vessels within 15-25 min. The response occurred at various combinations of temperature changes in different parts of the body. The heat content of the rabbit body, as calculated by the blood temperature in the aorta arc, reduced by 266.3 + or - 26.2 cal/kg at the beginning of the response. The decrease in the organism heat content seems to serve as a signal for occurrence of a corresponding thermoregulatory response.

Slepchuk, N. A.↗

A hydrodynamic model of an outer hair cell

On the model it is possible to measure the force and the force direction for each individual hair as a function of the flow direction and velocity. Measurements were made at the man flow velocity .01 m/s, which is equivalent to a flow velocity in the real ear of about 1 micrometer/s. The kinematic viscosity of the liquid used in the model was 10,000 times higher than the viscosity of perilymph to attain hydrodynamic equality. Two different geometries for the sterocilia pattern were tested. First the force distribution for a W-shaped sterocilia pattern was recorded. This is the sterocilia pattern found in all real ears. It is found that the forces acting on the hairs are very regular and perpendicular to the legs of the W when the flow is directed from the outside of the W. When the flow is reversed, the forces are not reversed, but are much more irregular. This can eventually explain the half wave rectification of the nerve signals. As a second experiment, the force distribution for a V-shaped sterocilia pattern was recorded. Here the forces were irregular both when the flow was directed into the V and when it was directed against the edge of the V.

Jacobson, B. O.↗

Locking hinge

The space station configuration currently studied utilizes structures which require struts to be hinged in the middle in the stowed mode and locked into place in the deployed mode. Since there are hundreds of hinges involved, it is necessary that they have simple, positive locking features with a minimum of joint looseness or slack. This invention comprises two similar housings hinged together with a spring loaded locking member which assists in making as well as breaking the lock. This invention comprises a bracket hinge and bracket members with a spring biased and movable locking member. The locking or latch member has ear parts received in locking openings where wedging surfaces on the ear parts cooperate with complimentary surfaces on the bracket members for bringing the bracket members into a tight end-to-end alignment when the bracket members are in an extended position. When the locking member is moved to an unlocking position, pivoting of the hinge about a pivot pin automatically places the locking member to retain the locking member in an unlocked position. In pivoting the hinge from an extended position to a folded position, longitudinal spring members are placed under tension over annular rollers so that the spring tension in a folded position assists in return of the hinge from a folded to an extended position. Novelty lies in the creation of a locking hinge which allows compact storage and easy assembly of structural members having a minimal number of parts.

Wesselski, Clarence J.↗

Comparison of speech intelligibility in cockpit noise using SPH-4 flight helmet with and without active noise reduction

Active Noise Reduction (ANR) is a new technology which can reduce the level of aircraft cockpit noise that reaches the pilot's ear while simultaneously improving the signal to noise ratio for voice communications and other information bearing sound signals in the cockpit. A miniature, ear-cup mounted ANR system was tested to determine whether speech intelligibility is better for helicopter pilots using ANR compared to a control condition of ANR turned off. Two signal to noise ratios (S/N), representative of actual cockpit conditions, were used for the ratio of the speech to cockpit noise sound pressure levels. Speech intelligibility was significantly better with ANR compared to no ANR for both S/N conditions. Variability of speech intelligibility among pilots was also significantly less with ANR. When the stock helmet was used with ANR turned off, the average PB Word speech intelligibility score was below the Normally Acceptable level. In comparison, it was above that level with ANR on in both S/N levels.

Chan, Jeffrey W.↗