At least 163 records · Page 9

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

Calibration of a 1 meter diameter normal incidence extreme ultraviolet telescope/spectrometer

A 1-meter normal incidence telescope, with a normal incidence concave diffraction grating spectrometer at its focus, has been developed. The instrument's spectral coverage is 350 to 1150A with a spectral resolution of 5A and a peak effective area of 6 sq cm at 500A. The instrument was launched on an Aries sounding rocket on November 27, 1983 in an effort to determine the hydrogen and helium abundance in the local interstellar medium. A description of this instrument, with the primary emphasis on the methods used to calibrate it, is presented.

Jelinsky, Patrick↗

The measured performance of a grazing incidence relay optics telescope for solar X-ray astronomy

The design, fabrication, and test performance of a grazing-incidence diverging magnifier (GIDM) for use in high-resolution X-ray imaging of the solar corona are described. The GIDM, designed to be mounted in front of the focus of a 30.48-cm Wolter-Schwarzschild primary, is an Ni-coated Be hyperboloid-hyperboloid structure of principal diameter 3.15 cm; the two components are mounted on a central steel plate which acts as a support and spacer. The combined instrument has overall length 1.9 m, effective focal length 5.4 m, and plate scale 26.0 micron/arcsec. In point- and line-source measurements in an 89.5-m vacuum test facility, the on-axis resolution is shown to be equal to that of the primary alone. The field of view for 1-arcsec resolution is limited to 1.25 arcmin in radius, but the effective-area limitation is less significant when CCD detectors of high quantum efficiency are used instead of film.

Moses, Dan↗

An electroformed mirror array for high energy X-ray astronomy

A design for a mirror array telescope for high energies with almost 1000 sq cm effective area at 7 keV is described. Briefly, it consists of 36 modules. Each module contains Wolter I mirrors nested 6 deep. The system is small enough to be flown on an Aries rocket. With the current mirrors, the angular resolution at high contrast is 20 arcsec and the half power diameter for images is 1.5 arcmin at 1.5 keV and 3.5 arcmin - 4 arcmin at 7 keV. Plans to improve upon this performance are discussed.

Ulmer, Melville P.↗

The project EGRET (Energetic Gamma-Ray Experiment Telescope) on NASA's Gamma-Ray Observatory (GRO)

The design, predicted performance, and scientific objectives of the 20-30,000-MeV gamma-ray telescope EGRET for the NASA GRO spacecraft (scheduled for Space Shuttle launch to a 450-km 28.5-deg orbit in 1990) are reviewed. The other GRO instruments are briefly characterized, including the burst and transient-source experiment, the oriented scintillation spectrometer, and the imaging Compton telescope. EGRET comprises an anticoincidence system, a spark chamber, a triggering telescope, an NaI total-absorption spectrometer, a gas supply capable of refilling the chamber four times, and support electronics. EGRET will operate with energy resolution about 15 percent, effective area about 2000 sq cm, sensitivity about 5 x 10 to the -8th/sq cm sec, angular resolution 0.1-0.4 deg, and FOV about 40 deg FWHM. Observations of Galactic point sources, Galactic and extragalactic diffuse emission, gamma-ray bursts, and solar flares are planned.

Kanbach, G.↗

Capabilities of GRO/OSSE for observing solar flares

The launch of the Gamma Ray Observatory (GRO) near solar maximum makes solar flare studies early in the mission particularly advantageous. The Oriented Scintillation Spectrometer Experiment (OSSE) on GRO, covering the energy range 0.05 to 150 MeV, has some significant advantages over the previous generation of satellite-borne gamma-ray detectors for solar observations. The OSSE detectors will have about 10 times the effective area of the Gamma-Ray Spectrometer (GRS) on Solar Maximum Mission (SMM) for both photons and high-energy neutrons. The OSSE also has the added capability of distinguishing between high-energy neutrons and photons directly. The OSSE spectral accumulation time (approx. 4s) is four times faster than that of the SMM/GRS; much better time resolution is available in selected energy ranges. These characteristics will allow the investigation of particle acceleration in flares based on the evolution of the continuum and nuclear line components of flare spectra, nuclear emission in small flares, the anisotropy of continuum emission in small flares, and the relative intensities of different nuclear lines. The OSSE observational program will be devoted primarily to non-solar sources. Therefore, solar observations require planning and special configurations. The instrumental and operational characteristics of OSSE are discussed in the context of undertaking solar observations. The opportunities for guest investigators to participate in solar flare studies with OSSE is also presented.

Kurfess, J. D.↗

The fatigue damage behavior of a single crystal superalloy

The uniaxial fatigue behavior of a single crystal superalloy, PWA 1480, is described. Both monotonic tensile and constant amplitude fatigue tests were conducted at room temperature, in an effort to assess the applicability of polycrystalline-based fatigue life prediction methods to a single crystal superalloy. The observed constant amplitude behavior correlated best using a stress-based life criterion. Nearly all specimens failed at surface or slightly subsurface microporosity; this is thought to be responsible for the unusually large amount of scatter in the test results. An additional term is developed in the stress-life equation for the purpose of accounting for the effect of microporosity on fatigue life. The form chosen is a function of the effective area of the failure-producing microporosity projected on a plane perpendicular to the loading axis, as well as the applied stress. This additional term correlated the data to within factors of two on life. Although speculative, extrapolation of the microporosity relation to zero micropore area indicates that approximately an order of magnitude improvement in fatigue life should result.

Mcgaw, Michael A.↗

The use of CCDs in the Space Telescope Imaging Spectrograph (STIS)

The present study describes the STIS instrument concept and the role and requirements of the CCD detectors. Specific required properties and the current status of the efforts to meet them are discussed. The goals of the STIS team include studies of the origin and evolution of the solar system, star formation, variable stellar phenomena, the nature and energy balance of the interstellar and intergalactic medium, and the origin and evolution of galaxies and their nuclear activity. The STIS operating modes (spectral range, resolving power, effective area, and angular range) and the optical arrangement to accomplish them are presented. The detective quantum efficiency of several candidate detector types are shown as a function of wavelength for the four STIS bands. Difficulties that arise in the use of CCDs are discussed. Consideration is given to the requirements imposed on STIS CCDs and to their performance.

Woodgate, Bruce E.↗

A high resolution echelle spectrometer for soft X-ray and EUV astronomy

A new design is presented for high resolution spectroscopy from 80 to 400 A. This design employs grazing incidence optics and variable line-spaced gratings to achieve high resolution. Unlike some previously proposed EUV echelles, this design employs straight groove planar gratings, which are a well-proven, easily manufactured design. The instrument delivers a peak resolution of 7500 and a peak effective area of 3 sq cm.

Green, James↗

Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

Vallerga, J. V.↗

Broadband Active Antenna

Effective area of search coil increased. Input impedance presented by operational amplifier and associated components nearly balances out impedance of search coil. Fluctuations in ambient magnetic field induce large currents in search coil.

Sutton, John F.↗

Operation and performance of the OSSE instrument

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly Compton Gamma Ray Observatory is described. An overview of the operation and control of the instrument is given, together with a discussion of typical observing strategies used with OSSE and basic data types produced by the instrument. Some performance measures for the instrument are presented that were obtained from pre-launch and in-flight data. These include observing statistics, continuum and line sensitivity, and detector effective area and gain stability.

Cameron, R. A.↗

COMPTEL: Instrument description and performance

The imaging Compton telescope (COMPTEL) is one of the four gamma ray detectors aboard the Compton Gamma Ray Observatory (GRO). COMPTEL is sensitive to gamma rays from 800 keV to 30 MeV with a field of view of approximately 1 sr. Its angular resolution ranges between 1 and 2 degrees depending on the energy and incidence angle. The energy resolution of better than 10 percent FWHM enables COMPTEL to provide spectral resolution in the regime of astrophysical nuclear lines. The effective area varies typically from 10 to 50 cm(exp 2) depending on the energy and event selections made. In its telescope mode, COMPTEL is able to study a wide variety of objects, pointlike as well as extended in space. With 0.125 msec timing resolution, pulsed emission can be studied. In the single detector mode, COMPTEL uses two of its detectors to study the temporal spectral evolution of strong gamma ray bursts or transients.

Denherder, J. W.↗

Biochemical, endocrine, and hematological factors in human oxygen tolerance extension: Predictive studies 6

The Predictive Studies VI (Biochemical, endocrine, and hematological factors in human oxygen tolerance extension) Program consisted of two related areas of research activity, integrated in design and performance, that were each based on an ongoing analysis of human organ oxygen tolerance data obtained for the continuous oxygen exposures of the prior Predictive Studies V Program. The two research areas effectively blended broad investigation of systematically varied intermittent exposure patterns in animals with very selective evaluation of specific exposure patterns in man.

Lambertsen, C. J.↗

Peeking through the picket fence - What astrophysical surprises may be present in the 100-200 A region?

In anticipation of more sensitive EUV and FUV spectroscopic instruments, spectra are simulated including interstellar absorption of solarlike, RS CVn, and flare stars as folded through the instrument parameters of the EUVE, Lyman/FUSE Phase A, and a desirable next-generation spectrometer. Even the relatively insensitive EUVE spectrometer is able to detect sufficient spectral lines from many active binary and dMe stars to determine their coronal-emission-measure distributions. The Lyman/FUSE or next-generation spectrometers are needed to study solar-type stars or flaring stars with high time resolution. The high throughput and effective area of a nex-generation spectrometer is needed for Doppler imaging studies, stellar wind and downflow measurements, and high time and spectral resolution of stellar flares.

Linsky, Jeffrey L.↗

Results from the calibration of the Extreme Ultraviolet Explorer instruments

The paper describes the main features and selected results of the calibration of the scientific instruments to be flown on the Extreme Ultraviolet Explorer in 1991. The instrument payload includes three grazing incidence scanning telescopes and an EUV spectrometer/deep survey instrument covering the spectral region 70-800 A. The measured imaging characteristics, the effective areas, and the details of spectral responses of the instruments are presented. Diagrams of the cross-sectional views of the scanning telescope and the deep-survey/spectrometer telescope are included.

Welsh, Barry Y.↗

VETA x ray data acquisition and control system

We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

Brissenden, Roger J. V.↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗