Search NASA⌕ Search

SEARCH · Search NASA

Results for “effective volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electrostatic propulsion beam divergence effects on spacecraft surfaces, volume 2

The third phase of a program to develop understanding of and tolerance-level criteria for the deleterious effects of electrostatic rocket exhaust (Cs, Cs(+), Hg, Hg(+)) and materials of rocket construction impinging on typical classes of spacecraft (S/C) surfaces was completed. Models of ion engine effluents and models describing the degradation of S/C surfaces by these effluents are presented. Experimental data from previous phases are summarized and Phase 2 data and analysis are presented in detail. The spacecraft design implications of ion engine contaminants are discussed.

Hall, D. F.↗

An Investigation of the Longitudinal Proximity Effect in Superconducting and Normal Metal TES

As the TES volume and (effective) Tc become very small - for volume < 10 micrometers x 10 micrometers x 0.5 micrometers and Tc < 90 mK - we approach a regime in which the noise equivalent power is dominated by fluctuations in power dissipating from the TES electrons to its phonons. Our ultimate goal is to build a TES bolometer that operates in this regime to be used for far-infrared and sub-mm astronomy. In this study, we characterize the R vs T behavior of small TES in order to engineer a TES bolometer that has a very low Tc. Sadleir et al found that as the distance L between two superconducting leads, with the lead Tc >> the TES Tc, connected at opposite ends of TES approaches zero, superconductivity is induced parallel to the current flow, or longitudinally, and results in a much higher effective TES Te. Here we present effective Te measurements of Mo/Au TES bounded by Nb leads as a function of L which ranges between 4 and 36 micrometer. We observe that the effective Te is suppressed for current density of order 10(exp -6) A/sq micrometers. We also explore the possibility of using a normal metal TES.

Brown, Ari-David↗

Constraint of pionless EFT using two-nucleon spectra from lattice QCD

Finite-volume pionless effective field theory (FVEFT π/ ) at next-to-leading order (NLO) is used to analyze the two-nucleon lattice QCD spectrum of Ref. [1], performed at quark masses corresponding to a pion mass of approximately 800 MeV. Specifically, the effective theory is formulated in finite volume, and variational sets of wave functions are optimized using differential programming. Using these wave functions projected to the appropriate finite-volume symmetry group, variational bounds from FVEFT π/ are obtained for the ground state, as well as excited states. By comparison with the lattice QCD GEVP spectrum, different low energy constants (LECs) are constrained. Furthermore, relativistic corrections are incorporated, allowing for the s-d-wave mixing term in the deuteron channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strategies for Effectively Visualizing a 3D Flow Using Volume Line Integral Convolution

This paper discusses strategies for effectively portraying 3D flow using volume line integral convolution. Issues include defining an appropriate input texture, clarifying the distinct identities and relative depths of the advected texture elements, and selectively highlighting regions of interest in both the input and output volumes. Apart from offering insights into the greater potential of 3D LIC as a method for effectively representing flow in a volume, a principal contribution of this work is the suggestion of a technique for generating and rendering 3D visibility-impeding 'halos' that can help to intuitively indicate the presence of depth discontinuities between contiguous elements in a projection and thereby clarify the 3D spatial organization of elements in the flow. The proposed techniques are applied to the visualization of a hot, supersonic, laminar jet exiting into a colder, subsonic coflow.

Interrante, Victoria↗

Changes in plasma volume during bed rest - Effects of menstrual cycle and estrogen administration

The effect of increased blood estrogen concentration, caused either during normal menstrual cycles or by exogenous administration of premarin, on the bed-rest (BR) induced decrease in plasma volume (PV) was investigated. In women who underwent duplicate 11-day BR without estrogen supplementation, the PV was found to decrease significantly, during the first 5 days of BR, to a lower level at which it remained for the rest of the BR period. In women who began BR in the periovulatory stage of the menstrual cycle, the loss of PV was delayed, while women who began BR during other stages of the cycle exhibited the usual trend of the PV decrease during the BR. In women who underwent a single 12-day BR period while taking premarin (1.25 mg/day), PV was found to decrease during the first 4-5 days of BR, but then returned toward the pre-BR level during the remainder of the BR, indicating that estrogens have a role in stabilizing body fluid volume.

Fortney, S. M.↗

To bin or not to bin: Does binning in multiplicity reliably suppress unwanted volume fluctuations?

Here, in this study, we examine the effect of the so-called Centrality Bin Width Correction (CBWC) on the measurement of (net-)proton number cumulants in nucleus-nucleus collisions. We present an analytically tractable model, which includes correlations between multiplicity and proton number similar to those generated by the decay of baryon resonances. Within this model, we analyze the circumstances under which the CBWC method correctly removes the undesired effects of volume or impact parameter fluctuations. Additionally, we explore situations where the method fails and produces misleading results.

Critical point↗

Effects of Mesh Irregularities on Accuracy of Finite-Volume Discretization Schemes

The effects of mesh irregularities on accuracy of unstructured node-centered finite-volume discretizations are considered. The focus is on an edge-based approach that uses unweighted least-squares gradient reconstruction with a quadratic fit. For inviscid fluxes, the discretization is nominally third order accurate on general triangular meshes. For viscous fluxes, the scheme is an average-least-squares formulation that is nominally second order accurate and contrasted with a common Green-Gauss discretization scheme. Gradient errors, truncation errors, and discretization errors are separately studied according to a previously introduced comprehensive methodology. The methodology considers three classes of grids: isotropic grids in a rectangular geometry, anisotropic grids typical of adapted grids, and anisotropic grids over a curved surface typical of advancing layer grids. The meshes within the classes range from regular to extremely irregular including meshes with random perturbation of nodes. Recommendations are made concerning the discretization schemes that are expected to be least sensitive to mesh irregularities in applications to turbulent flows in complex geometries.

Diskin, Boris↗

Flexure fatigue testing of 90 deg graphite/epoxy composites

A great deal of research has been performed characterizing the in-plane fiber-dominated properties, under both static and fatigue loading, of advanced composite materials. To the author's knowledge, no study has been performed to date investigating fatigue characteristics in the transverse direction. This information is important in the design of bonded composite airframe structure where repeated, cyclic out-of-plane bending may occur. Recent tests characterizing skin/stringer debond failures in reinforced composite panels where the dominant loading in the skin is flexure along the edge of the frame indicate failure initiated either in the skin or else the flange, near the flange tip. When failure initiated in the skin, transverse matrix cracks formed in the surface skin ply closest to the flange and either initiated delaminations or created matrix cracks in the next lower ply, which in turn initiated delaminations. When failure initiated in the flanges, transverse cracks formed in the flange angle ply closest to the skin and initiated delamination. In no configuration did failure propagate through the adhesive bond layer. For the examined skin/flange configurations, the maximum transverse tension stress at failure correlates very well with the transverse tension strength of the composites. Transverse tension strength (static) data of graphite epoxy composites have been shown to vary with the volume of material stressed. As the volume of material stressed increased, the strength decreased. A volumetric scaling law based on Weibull statistics can be used to predict the transverse strength measurements. The volume dependence reflects the presence of inherent flaws in the microstructure of the lamina. A similar approach may be taken to determine a volume scale effect on the transverse tension fatigue behavior of graphite/epoxy composites. The objective of this work is to generate transverse tension strength and fatigue S-N characteristics for composite materials using 3-point flexure tests of 90 deg graphite/epoxy specimens. Investigations will include the volume scale effect as well as frequency and span-to-thickness ratio effects. Prior to the start of the experimental study, an analytical study using finite element modeling will be performed to investigate the span-to-thickness effect. The ratio of transverse flexure stress to shear stress will be monitored and its values predicted by the FEM analysis compared with the value obtained using a 'strength of materials' based approach.

Peck, Ann Nancy W.↗

Effect of prolonged bed rest on lung volume in normal individuals

The effect of prolonged bed rest on the lung function was studied by measuring forced vital capacity (FVC) and total lung capacity (TLC) in normal subjects before, during, and after 11- to 12-day rest periods. It was found that both FVC and TLC increased during bed rest (compared with the ambulatory controls), while residual volume and functional residual capacity of the respiratory system did not change. It is concluded that the increase in TLC by prolonged bed rest is not dependent on alterations in plasma volume.

Beckett, W. S.↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗

Effects of pressure- or volume-overload hypertrophy on passive stiffness in isolated adult cardiac muscle cells

It has been hypothesized that the changes in myocardial stiffness induced by chronic hemodynamic overloading are dependent on changes in the passive stiffness of the cardiac muscle cell (cardiocyte). However, no previous studies have examined the passive constitutive properties of cardiocytes isolated from animals with myocardial hypertrophy. Accordingly, changes in relative passive stiffness of cardiocytes isolated from animals with chronic pressure- or volume-overload hypertrophy were determined by examining the effects of anisosmotic stress on cardiocyte size. Anisosmotic stress was produced by altering superfusate osmolarity. Hypertrophied cardiocytes were enzymatically isolated from 16 adult cats with right ventricular (RV) pressure-overload hypertrophy induced by pulmonary artery banding (PAB) and from 6 adult cats with RV volume-overload hypertrophy induced by creating an atrial septal defect (ASD). Left ventricular (LV) cardiocytes from each cat served as nonhypertrophied, normally loaded, same-animal controls. Superfusate osmolarity was decreased from 305 +/- 3 to 135 +/- 5 mosM and increased to 645 +/- 4 mosM. During anisosmotic stress, there were no significant differences between hypertrophied RV and normal LV cardiocytes in pressure overload PAB cats with respect to percent change in cardiocyte area (47 +/- 2% in RV vs. 48 +/- 2% in LV), diameter (46 +/- 3% in RV vs. 48 +/- 2% in LV), or length (2.4 +/- 0.2% in RV vs. 2.0 +/- 0.3% in LV), or sarcomere length (1.5 +/- 0.1% in RV vs. 1.3 +/- 0.3% in LV). Likewise, there were no significant differences in cardiocyte strain between hypertrophied RV and normal LV cardiocytes from ASD cats. In conclusion, chronic pressure-overload hypertrophy and chronic volume-overload hypertrophy did not alter the cardiocyte response to anisosmotic stress. Thus chronic overload hypertrophy did not alter relative passive cardiocyte stiffness.

Non-NASA Center↗

Charged multihadron systems in lattice QCD+QED

Systems with the quantum numbers of up to 12 charged and neutral pseudoscalar mesons, as well as one-, two-, and three-nucleon systems, are studied using dynamical lattice quantum chromodynamics and quantum electrodynamics (QCD+QED) calculations and effective field theory. QED effects on hadronic interactions are determined by comparing systems of charged and neutral hadrons after tuning the quark masses to remove strong isospin breaking effects. A nonrelativistic effective field theory, which perturbatively includes finite-volume Coulomb effects, is analyzed for systems of multiple charged hadrons and found to accurately reproduce the lattice QCD+QED results. QED effects on charged multihadron systems beyond Coulomb photon exchange are determined by comparing the two- and three-body interaction parameters extracted from the lattice QCD+QED results for charged and neutral multihadron systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ni 3 Si 2 nanowires for efficient electron field emission and limitations of the Fowler–Nordheim model

This article reports on top-down nanofabricated Ni 3 Si 2 nanowires and tests of their electron field emission capabilities. Here, the results include low turn-on electric field, E ON , moderate work function, Φ, and the field enhancement factor, β, customizable through nanofabrication. The article also reports on the issues ahead in the field of nanowires-based electron mission, as there are quantitative limitations of the applicability of the Fowler–Nordheim model, which will become increasingly apparent as we continue to optimize the field emission of electrons. To this end, we suggest adding the studies of surface-to-volume ratio effects of the nanowires as another standard for comparison in order to lead to the input form of the density of states as quantum effects becoming more prominent.

42 ENGINEERING↗