Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

LABORATORY INVESTIGATIONS OF POLYCYCLIC AROMATIC HYDROCARBON FORMATION AND DESTRUCTION IN THE CIRCUMSTELLAR OUTFLOWS OF CARBON STARS

The formation and destruction mechanisms of interstellar dust analogs formed from a variety of polycyclic aromatic hydrocarbon (PAH) and hydrocarbon molecular precursors are studied in the laboratory. We used the newly developed facility COSmIC, which simulates interstellar and circumstellar environments, to investigate both PAHs and species that include the cosmically abundant atoms O, N, and S. The species generated in a discharge plasma are detected, monitored, and characterized in situ using highly sensitive techniques that provide both spectral and ion mass information. We report here the first series of measurements obtained in these experiments which focus on the characterization of the most efficient molecular precursors in the chemical pathways that eventually lead to the formation of carbonaceous grains in the stellar envelopes of carbon stars. We compare and discuss the relative efficiencies of the various molecular precursors that lead to the formation of the building blocks of carbon grains. We discuss the most probable molecular precursors in terms of size and structure and the implications for the expected growth and destruction processes of interstellar carbonaceous dust.

79 ASTRONOMY AND ASTROPHYSICS↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-cost Retrofit Kit for Integral Reciprocating Compressors (IRCs) to Reduce Emissions and Enhance Efficiency

Methane emissions from natural gas engines within the oil and gas industry pose a significant environmental challenge, contributing approximately 34.1 MMTCO2 eq to the total of 239 MMTCO2 eq of methane emissions in 2021, according to the EPA report. In response to this pressing issue, a collaborative effort involving the University of Oklahoma and key industry partners—WAGO Automation, Mid Continental Rental, Elipsa, and Perscient—has resulted in the development of a retrofit kit designed to reduce emissions from integral reciprocating compressors (IRCs), which are integrated compressors and engines. The retrofit kit developed comprises an Air Management System (AMS), Integrated Sensors, and a Cloud-Connected Control Unit with Graphical User Interface (GUI)/Human-Machine Interface (HMI). This solution enhances operational efficiency, reduces emissions, and expands the operational envelope of IRCs in the natural gas industry. The project successfully completed all tasks, including the installation of a full-size IRC at a designated site in Oklahoma, the development of an optimized AMS, integration of sensors, and implementation of a data acquisition system. Significant achievements include a notable reduction in CH 4 emissions, up to 84% at specific loads, and the successful deployment of the retrofit kit in diverse field conditions. The system's capabilities were enhanced through the creation of a feedback control algorithm for the AMS using a correlation matrix illustrating relationships between engine parameters, and the design of a predictive and preventive maintenance platform. The project concluded with the deployment of the entire retrofit kit to another location, confirming its effectiveness in reducing emissions and enhancing IRC performance. The comprehensive solution offers valuable benefits for IRCs, making them invaluable assets in the natural gas industry.

03 NATURAL GAS↗

Modelling moisture sources due to air leakage with the HAMT extension for EnergyPlus

The moisture performance of building envelope components is one of the main challenges of energy efficient buildings. The combined Heat and Moisture Transfer (HAMT) model in EnergyPlus can provide moisture profiles through multiple material layers of an envelope assembly using a coupled, one-dimensional, finite volume model simulating the movement and storage of heat and moisture. Currently only a limited assessment of the effects of moisture sources inside an assembly to determine impacts on durability, indoor air quality, and energy performance is possible. This paper discusses different strategies to model moisture sources in building components due to air leakage. Models that enable air leakage to result in a moisture sink/source at an arbitrary location extend the existing mass transfer equation with a source term that includes water vapor deposit from air flow through an assembly. New sub-models with different levels of complexity to calculate the air flow through the assembly are developed. The air flow can be user defined, it can be computed as a result of the stack height and a user defined ventilation overpressure or completely derived from an air-flow network. We explain the model enhancements, discuss the required inputs for every option together with related limitations, showcase the model application and make the source code publicly available for external use.

Antretter, Florian↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BROADBAND EXTENDED EMISSION IN GRAVITATIONAL WAVES FROM CORE-COLLAPSE SUPERNOVAE

Immediately following their formation, black holes in the core-collapse stage of massive stars are expected to surge in mass and angular momentum by hyper-accretion. Here we describe a general framework of extended emission in gravitational waves from non-axisymmetric accretion flows from the fallback matter of the progenitor envelope. This framework shows (a) a maximum efficiency in the conversion of accretion energy into gravitational waves at hyper-accretion rates exceeding a critical value set by the ratio of the quadrupole mass inhomogeneity and viscosity, with (b) a peak characteristic strain amplitude at the frequency f{sub b} = Ω{sub b}/π, where Ω{sub b} is the Keplerian angular velocity at which viscous torques equal angular momentum loss in gravitational radiation, with h{sub char} ∝ f{sup 1/6} at f < f{sub b} and h{sub char} ∝ f{sup −1/6} at f > f{sub b}. Upcoming gravitational wave observations may probe this scaling by extracting broadband spectra using time-sliced matched filtering with chirp templates, which were recently developed for identifying turbulence in noisy time series.

79 ASTRONOMY AND ASTROPHYSICS↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

P2P: Point Cloud to Panel Layout Optimization

Building envelope retrofits, despite their benefits on enhancing energy efficiency, progress slowly due to high operating costs. Overclad panelized systems present an attractive solution to make retrofits affordable and easy to install. However, several stages of the retrofit process remain disconnected, suboptimal, and require significant human intervention. This study aims to bridge the gap between digital twin generation and overclad panel installation by automating the design of an optimal panel layout directly from a building envelope point cloud. In this end-to-end approach, the dimensional twin is generated by segmenting the facade point cloud. The facade then undergoes a three-step process to generate an optimized panel layout for integration with automated placement systems.

Philips, Nisha Deborah [ORNL]↗

Demonstration and characterization of insertable passive thermal switches for dynamic building envelopes

A dynamic building envelope integrated with thermal energy storage, such as phase change material (PCM), is an emerging technology that offers a promising solution to improve the energy efficiency of buildings. This study reports the development of insertable thermal switches, which modulate thermal resistance, thereby making building envelopes dynamic and enhancing the use of free ambient heating and cooling. The reported thermal switches are passive, meaning they work solely based on indoor and outdoor temperatures. A single switch when inserted into 10 × 10-in (0.064-m 2 ) XPS foam board insulation demonstrates effective thermal conductivity of 0.050 W/m-K in the resistive state and 0.285 W/m-K in the conductive state. Thermal switches exhibit an effective switching ratio of 5.7, with no noticeable degradation in performance over 770 cycles. Additionally, when integrated into a wall sample containing a PCM layer, switches significantly reduce the PCM solidification time by 43.2% during the cooling process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Performance Envelope of Axial Flow HEPA Filter Designs - 17466

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the Department of Energy National Nuclear Security Administration (DOE/NNSA) complex. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels and conditions that fibrous glass HEPA filters can handle. Axial Flow filters can be purchased with physical separators or embossed medium to maintain proper pleat geometry. Separator-less designs use media embossed with a corrugation pattern to retain pleat geometry. At least some versions of the separator-less filter packs have demonstrated unexpected and rapid failure under slightly elevated temperature and humidity conditions. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. Mississippi State University is conducting studies to more clearly identify the operating envelope of separator and separator-less designs of ASME AG-1 Section FC axial flow HEPA filters under a set of generic design basis conditions. A parallel study is also being conducted to evaluate the effects of age on fibrous glass HEPA filters. Activities described in this paper have been conducted under Institute for Clean Energy Technology (ICET's) NQA-1 nuclear quality assurance program approved by DOE-EM. Testing meets the requirements of EM Quality Assurance Program (QAP) EM-QA-001, Rev. 1, June 11, 2012 that includes the applicable requirements of NQA-1-2008/2009a and DOE Order 414.1D. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

Recovery Act. Advanced Building Insulation by the CO 2 Foaming Process

In this project, ISTN proposed to develop a new "3rd" generation of insulation technology. The focus was a cost-effective foaming process that could be used to manufacture XPS and other extruded polymer foams using environmentally clean blowing agents, and ultimately achieve higher R-values than existing products while maintaining the same level of cost-efficiency. In the U.S., state-of-the-art products are primarily manufactured by two companies: Dow and Owens Corning. These products (i.e., STYROFOAM and FOAMULAR) have a starting thermal resistance of R-5.0/inch, which declines over the life of the product as the HFC blowing agents essential to high R-value exchange with air in the environment. In the existing technologies, the substitution of CO2 for HFCs as the primary foaming agent results in a much lower starting R-value, as evidenced in CO2-foamed varieties of XPS in Europe with R-4.2/inch insulation value. The major overarching achievement from this project was ISTN's development of a new process that uses CO2 as a clean blowing agent to achieve up to R-5.2/inch at the manufacturing scale, with a production cost on a per unit basis that is less than the cost of Dow and Owens Corning XPS products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Embodied Carbon Reduction in New Construction: Reference Guide

The U.S. Department of Energy launched the Advanced Building Construction (ABC) Initiative in 2019 to modernize and streamline building renovation and construction processes that facilitate the integration of high-performance and low-carbon solutions in the U.S. building stock. There are four attributes of ABC that are the focus of the Initiative: affordable, fast, appealing, and low carbon. Substantial improvements have been made to reduce operational carbon emissions of buildings through efficiency and electrification. However, to achieve low-carbon new construction buildings, increased efforts to reduce the embodied carbon of buildings are needed. Embodied carbon emissions in buildings come primarily from the manufacturing of building envelope materials such as concrete, steel, lumber, and glass, among others. Recent studies show that construction and renovation of buildings account for 5% of energy use and 10% of carbon emissions globally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-linear tearing of 3D null point current sheets

The manner in which the rate of magnetic reconnection scales with the Lundquist number in realistic three-dimensional (3D) geometries is still an unsolved problem. It has been demonstrated that in 2D rapid non-linear tearing allows the reconnection rate to become almost independent of the Lundquist number (the “plasmoid instability”). Here, we present the first study of an analogous instability in a fully 3D geometry, defined by a magnetic null point. The 3D null current layer is found to be susceptible to an analogous instability but is marginally more stable than an equivalent 2D Sweet-Parker-like layer. Tearing of the sheet creates a thin boundary layer around the separatrix surface, contained within a flux envelope with a hyperbolic structure that mimics a spine-fan topology. Efficient mixing of flux between the two topological domains occurs as the flux rope structures created during the tearing process evolve within this envelope. This leads to a substantial increase in the rate of reconnection between the two domains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of radial self-field geometry for intense pulsed ion beam generation above 6 MeV on Hermes III.

We investigate the generation and propagation of intense pulsed ion beams at the 6 MeV level and above using the Hermes III facility at Sandia National Laboratories. While high-power ion beams have previously been produced using Hermes III, we have conducted systematic studies of several ion diode geometries for the purpose of maximizing focused ion energy for a number of applications. A self-field axial-gap diode of the pinch reflex type and operated in positive polarity yielded beam power below predicted levels. This is ascribed both to power flow losses of unknown origin upstream of the diode load in Hermes positive polarity operation, and to anomalies in beam focusing in this configuration. A change to a radial self-field geometry and negative polarity operation resulted in greatly increased beam voltage (> 6 MeV) and estimated ion current. A comprehensive diagnostic set was developed to characterize beam performance, including both time-dependent and time-integrated measurements of local and total beam power. A substantial high-energy ion population was identified propagating in reverse direction, i.e. from the back side of the anode in the electron beam dump. While significant progress was made in increasing beam power, further improvements in assessing the beam focusing envelope will be required before ultimate ion generation efficiency with this geometry can be completely determined.

43 PARTICLE ACCELERATORS↗