Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aircraft electric motor having a stator heat pipe cooling scheme

Aircraft electric motors are described. The aircraft electric motors include a motor unit having a rotor and a stator, wherein the stator includes a plurality of windings and cooling channels arranged to provide cooling to the plurality of windings, a drive unit configured to drive operation of the motor unit, and a cooling system. The cooling system includes an oscillating heat pipe containing a first working fluid, wherein the oscillating heat pipe is arranged to pick up heat from at least one winding, the oscillating heat pipe having an evaporator section arranged in thermal contact with the at least one winding and a condenser section arranged away from the evaporator section and a heat pickup portion arranged to receive a second working fluid to remove heat from the condenser section of the oscillating heat pipe.

Saviers, Kimberly Rae↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fluidized-bed heat exchanger for conversion of thermal energy to electricity

The present disclosure describes heat exchangers for converting thermal energy stored in solid particles to electricity. Electro-thermal energy storage converts off-peak electricity into heat for thermal energy storage, which may be converted back to electricity, for example during peak-hour power generation. The heat exchanger for converting thermal energy stored in solid particles to electricity enables the conversion of thermal energy into electrical energy for redistribution to the grid. In some embodiments, pressurized fluidized-bed heat exchangers may achieve efficient conversion of thermal energy to electricity by providing direct contact of the solid particles with a gas stream.

Ma, Zhiwen↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bench-Scale Development of a Novel Direct Air Capture Technology Using High-Capacity Structured Sorbents

The work performed under this project has resulted into development of a DAC technology utilizing a structured sorbent to capture CO 2 from ambient air with a key innovation of direct Joule heating of the sorbent for CO 2 desorption. A working SMA, fully integrated with an electrically resistive heating layer, high surface area support, and high CO 2 capacity sorbent coated onto a commercial ceramic monolithic substrate, was successfully developed and demonstrated over >200 adsorption-desorption cycles in a high-fidelity bench test unit directly using ambient air. A cordierite-based monolith was selected as a substrate owing to its high surface area, low bulk density, low heat capacity, and commercial availability. Reaction kinetics study conducted during this project led to development of a promoter for the base Na 2 CO 3 sorbent that could be incorporated into the sorbent to enhance to achieve higher CO 2 adsorption/desorption rates, greater working capacity, and reduced regeneration temperature. An accelerated aging study was conducted in a TGA to determine sorbent stability and no degradation in the sorbent performance was observed even after 250 adsorption-desorption cycles. An electrically resistive heating layer was developed with tunable electrical properties. The heating layer was coated onto the selected cordierite substrate. Aging studies performed showed the electrical properties and heating performance was stable after 500 heating and cooling cycles. The collective findings on the selected cordierite substrate, robust heating layer, promoter and sorbent selection were used to synthesize a full, 6”x6” SMA for bench-scale testing. The bench-scale DAC system was constructed to test full size SMAs using real ambient air for adsorption and joule heating for regeneration. After completing shakedown and commissioning of the 1 kg/day of CO 2 capacity DAC bench unit, an extended operation was performed to complete over 230 cycles with the full size SMA. This testing showed no observable degradation in sorbent performance. A detailed process model, TEA and LCA were developed for a conceptual 100,000 TPY CO 2 removal DAC facility. The LCA results show the net CO 2 e emissions from the DAC system are highly dependent on the electricity source. All other factors, including SMA manufacturing, materials for facility enclosure, etc., are minor cost contributors compared to the energy consumption required for CO 2 removal. With the successful development and validation of the SMA for the sustained performance for CO 2 removal from ambient air with joule heated regeneration in this project, a fully integrated 1 TPY bench-scale DAC system is currently in development with the support of DOE/FECM (DE-FE0032243). The project objective is to demonstrate the engineering design of the DAC system to produce a continuous, high purity CO 2 stream from ambient air. This project will address and validate key engineering features of the DAC system including the gas sealing mechanism and panels, enclosure and air contactor design, and automation sequence to achieve continuous CO 2 production.

42 ENGINEERING↗

Assessment of Nuclear Energy to Support Negative Emission Technologies

The feasibility and performance of nuclear energy coupled with Negative Emission Technology (NET) processes were investigated in this report. Three overarching questions from nuclear NET systems guided this research: which NET would be able to use heat and/or electricity from nuclear power plants (NPPs); what is the performance and cost of a nuclear NET system; and what would be the market outlook for this system? Among the various NETs that are actively being developed, several were found to potentially benefit from coupling with an NPP via (1) large amounts of decarbonized and constant-output electricity; (2) free waste heat or cheap low-temperature heat; or (3) high-temperature heat. NPPs were found to be compatible with Direct Air Capture (DAC) systems, and a detailed techno-economic analysis of coupled NPP&DAC systems was performed. Preliminary analysis also indicated that biomass and water-based NETs are potentially compatible with NPPs, but further work is needed to quantify the performance of these nuclear NET systems. Design and performance analyses were completed for both liquid solvent DAC (L-DAC) and solid sorbent DAC (S-DAC) technologies. A 1.0-GWth NPP coupled with L-DAC and S-DAC was found to be able to capture 12–15 Mt CO 2 /yr and 1.0–1.5 Mt CO 2 /yr, respectively. While the L-DAC process enables much greater CO 2 capture than the S-DAC process when both are sized with a 1 GWth NPP, the NPP&L-DAC system considered also requires >2 GWth natural gas oxy-combustion to reach adequate temperature in the calciner. CO 2 generated from natural gas combustion is also captured as part of the calcination process, in addition to the CO 2 captured from air, resulting in overall CO 2 sequestration of close to 30% more than what is captured from air. The cost of carbon capture calculated with the levelized cost of DAC (LCOD) had a range of $\$170–260$/tCO 2 for NPP&L-DAC systems and a range of $\$650–680$/tCO 2 for NPP&S-DAC systems. For both DAC systems, the NPP provides economic benefit when compared to previous National Energy Technology Laboratory (NETL) studies of non-nuclear DAC systems, leading to reduction of LCOD by 5–7% for L-DAC, and 8–13% for S-DAC. For the NPP&DAC systems, a preliminary market analysis reviewed potential CO 2 market prices and eligibility for incentives. The estimated potential revenues for CO 2 capture (coming from federal incentive, CO 2 commodity markets, or offset market) is in the range of $\$170–979$ tCO 2 , and the results show that because of lower LCOD, the NPP&L-DAC process would be more attractive to a market than the NPP&S-DAC process. The large investment needed for NPP&DAC processes would require long-term certainty of sufficient market size, CO 2 prices, and incentives. Enabling NPPs to ramp DAC operation up or down based on electricity market price is not expected to significantly increase revenues of the NPP&DAC system. This is because the revenues from CO 2 sequestration are required to be very high to justify the deployment and continuous operation of the very expensive DAC technologies. In this analysis, several new research questions were uncovered, and follow-up analyses are recommended for further investigation, including a detailed feasibility study of NPP coupled with other NET systems such as biomass pyrolysis and gasification with carbon capture and storage, and seawater carbon capture.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Short-term electricity load forecasting: Application-driven evaluation of machine learning models across spatial and temporal scales

As we transition towards a decarbonized economy, the integration of variable renewable energy resources and new demands (e.g., electric vehicles, heat pumps) into the electricity grid places unprecedented pressure on grid operators to effectively anticipate and manage peak load. In this context, machine learning algorithms are proving to be indispensable for accurate short-term load forecasting, a crucial task to address these challenges. This study benchmarks 6 machine learning algorithms, including three neural networks and three tree-based algorithms, across various levels of spatial aggregation and time horizons (1, 4, 8, 24, and 48 h). The central contribution of this work is the comparison and analysis of load forecasting models not only based on statistical metrics, but also based on a novel error metric, which evaluates the cost implications of forecast errors for power system stakeholders. Results show that tree-based models outperform neural networks, based on statistical metrics, and yield less skewed error distributions for most spatial scales. However, through the lens of the novel error metric, neural networks are the more competitive choice, especially for forecast horizons that exceed 8 h. The study concludes with actionable recommendations to grid operators and highlights the need for the development of error metrics that link forecasting accuracy to operational costs. To promote transparency and open science, the datasets and Python code are open-sourced via a supplementary repository.

Houben, Nikolaus↗

Air-stable, earth-abundant molten chlorides and corrosion-resistant containment for chemically-robust, high-temperature thermal energy storage for concentrated solar power

A dramatic reduction in man-made CO 2 emissions could be achieved if the cost of electricity generated from concentrated solar power (CSP) plants could become competitive with fossil-fuel-derived electricity. The solar heat-to-electricity conversion efficiency of CSP plants may be significantly increased (and the associated electricity cost decreased) by operating CSP turbines with inlet temperatures ≥750 °C instead of ≤550 °C, and by using thermal energy storage (TES) at ≥750 °C to allow for rapidly dispatchable and/or continuous electricity production. Unfortunately, earth-abundant MgCl 2 -KCl-based liquids currently being considered as low-cost media for large-scale, high-temperature TES are susceptible to oxidation in ambient air, with associated undesired changes in liquid composition and enhanced corrosion of metal alloys in pipes and tanks containing such liquids. In this paper, alternative high-temperature, earth-abundant molten chlorides that are resistant to oxidation in ambient air are identified via thermodynamic calculations. Here, the oxidation resistance, and corrosion-resistant containment, of such molten chlorides at 750 °C are then demonstrated. Such an air-tolerant strategy, involving chemically-robust, low-cost TES media paired with effective containment materials, provides a critical advance towards the higher-temperature operation of, and lower-cost electricity generation from, CSP plants.

14 SOLAR ENERGY↗

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanically-, Thermally, and Chemically-Robust High-Temperature Ceramic Composites

In an effort to lower the levelized cost of electricity generated by Concentrated Solar Power (CSP) plants, the heat-to-electricity conversion efficiency may be increased by operating such plants with higher turbine inlet temperatures using closed Brayton cycles with high-pressure, supercritical carbon dioxide (sCO 2 ) as the working fluid. For example, if the turbine inlet temperature is raised to ≥750°C, in combination with sCO2 closed Brayton cycles, the relative heat-to-electricity efficiency may be raised by more than 20% (compared to subcritical steam Rankine cycles operating with turbine inlet temperatures ≤550°C). The associated reduction in the cost of dispatchable electricity from such CSP plants (utilizing high-temperature thermal energy storage) would be an important breakthrough on the path towards direct competition with fossil-fuel-based plants. A key barrier to achieve such high-temperature efficient operation has been the limited thermomechanical performance of metal alloys used in compact, primary printed circuit- type heat exchangers (PCHEXs) for heat transfer to high-pressure sCO 2 . The maximum allowed stresses for the use of conventional stainless steels and nickel-based superalloys at high sCO 2 pressures (≥20 MPa) decline rapidly at temperatures ≥550°C. This project has been focused on demonstrating the desired high-temperature properties and attractive manufacturing characteristics of mechanically-, thermally-, and chemically-robust ceramic/metal composites (cermets), in order to allow for the use of such composites in primary PCHEXs for heat transfer to sCO 2 at ≥750°C and ≥20 MPa in CSP plants. Prior work with high-temperature, co-continuous carbide/refractory metal cermets, such as ZrC/W composites, has already demonstrated: i) the attractive combination of high-temperature properties exhibited by such materials (e.g., high values of stiffness, failure strength, and thermal conductivity at 800°C), and ii) cost-effective processes for manufacturing PCHEX plates comprised of such cermets with tailorable channel patterns. However, ZrC/W cermets were not found to be inherently corrosion resistant in sCO 2 at 750°C and 20 MPa. While the application of a Cu coating to ZrC/W surfaces, along with a modest addition (50 ppm) of CO to CO 2 , rendered such composites resistant to corrosion for 1000 h in such sCO 2 -based fluids at 750°C, such additional steps would increase the design complexity of such cermet-based components. An alternative approach (the focus of this project) is to develop mechanically-robust, cost- effective cermets that are inherently resistant to high-temperature oxidation in air and CO 2 . The overall goals of this project have been to demonstrate: i) the oxidation resistance of at least one cermet at 750°C in air and in CO 2 (i.e., with a projected annual corrosion ≤30 μm), ii) the mechanically robust nature of at least one cermet at 750°C (i.e., with an average failure strength ≥200 MPa), and iii) that the selected cermet can be manufactured via low-cost forming techniques.

14 SOLAR ENERGY↗

Dissolution of Nb(C,N) and (Ti,V)N in the Coarse-Grained Heat-Affected Zone of Electric Resistance Welded X65 Line Pipe

Nb-rich and Ti/V-rich precipitates were introduced into the X65 linepipe via thermomechanical controlled processing. Their dissolution kinetics were investigated in the coarse-grained heat-affected zone after electric resistance welding. Nb-rich precipitates were found to dissolve completely, whereas Ti/V-rich precipitates were found to dissolve partially, because of slower dissolution kinetics. In conclusion, a complete dissolution of Nb-rich precipitates was associated with significant austenite grain coarsening, which promoted bainite as a quench product, which might have reduced the impact toughness.

microstructure↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

GEOPHIRES v2.0

GEOPHIRES v2.0 is a geothermal techno-economic simulation tool upgraded from GEOPHIRES v1.2. The name stands for "GEOthermal energy for Production of Heat and electricity (“IR”) Economically Simulated". GEOPHIRES combines reservoir, wellbore, and surface plant technical models with cost correlations and levelized cost models to estimate the capital and operation and maintenance costs, instantaneous and lifetime energy production, and overall levelized cost of energy of a geothermal plant. In addition to electricity generation, direct-use heat applications and combined heat and power or cogeneration can be modeled. Various upgrades have been implemented to develop GEOPHIRES v2.0, including: updating the built-in cost correlations, coupling to the external reservoir simulator TOUGH2, enhancing the built-in wellbore simulator, converting the programming language to Python, and making the code open-source. Users are encouraged to build upon the tool, e.g. by implementing their own correlations or coupling to other simulators.

Beckers, Koenraad↗