Application Of Artificial Intelligence To Wind Tunnels

Report discusses potential use of artificial-intelligence systems to manage wind-tunnel test facilities at Ames Research Center. One of goals of program to obtain experimental data of better quality and otherwise generally increase productivity of facilities. Another goal to increase efficiency and expertise of current personnel and to retain expertise of former personnel. Third goal to increase effectiveness of management through more efficient use of accumulated data. System used to improve schedules of operation and maintenance of tunnels and other equipment, assignment of personnel, distribution of electrical power, and analysis of costs and productivity. Several commercial artificial-intelligence computer programs discussed as possible candidates for use.

Lo, Ching F.↗

Overview of environmental test plans for Space Station Freedom work package 4

The generation and distribution of electric power for Space Station Freedom (SSF) is critical to the station's success. Work Package 4 (WP-04) has the responsibility for the design, development, test, and delivery of the Electric Power System (EPS) for the SSF. During launch, assembly, and operation, the EPS will be subjected to various environments. A test and verification approach has been developed to assure that the EPS will function in these environments. An overview of that test program is presented with emphasis on environmental testing of hardware. Two key areas of the test program are highlighted in the overview. One area is the verification of the Solar Power Module (SPM) and associated cargo element hardware. This area includes detailing the plans for development and qualification testing of the SPM hardware. One series of tests, including modal and acoustic, has been completed on a development cargo element. Another area highlighted is the acceptance testing of high-power Orbital Replacement Units (ORU). The environmental test equipment plans are presented and reviewed in light of an aggressive production rate, which delivers ORU's to the WP-04 and other Space Station Work Packages. Through implementing the test program as outlined, the EPS hardware will be certified for flight and operation on the Space Station Freedom.

Peterson, Tom J.↗

[X-33 Systems]

Lockheed Martin Skunk Works has compiled an Annual Performance Report of the X-33/RLV Program. This report consists of individual reports from all industry team members, as well as NASA team centers. This portion of the report is comprised of a status report of Allied-Signal Aerospace's contribution to the program. The following is a summary of the work reviewed under their portion of the agreement: (1) Communication Systems; (2) Environmental Control Systems- Active Thermal Control System (ATCS), Purge and Vent System, Hydrogen Detection System (HDS), Avionics Bay Inerting System (ABIS), and Flush Air Data System (FADS); (2) Landing Systems; (3) Power Management and Generation Systems; (4) Flight Control Actuation System (FCAS)- Electric Power Control & Distribution System (EPCDS), and Battery Power System (BPS); and (5) Vehicle Management Systems (VMS)- VMS Hardware, VMS Software Development Activities, and System Integration Laboratory (SIL).

Source record↗

Solid freeform fabrication apparatus and methods

An apparatus for formation of a three dimensional object comprising a sealed container; an electron beam subsystem capable of directing energy within said container; a positioning subsystem contained within said container; a wire feed subsystem contained within said container; an instrumentation subsystem electronically connected to said electron beam subsystem, positioning subsystem, and wire feed subsystem; and a power distribution subsystem electrically connected to said electron beam subsystem, positioning subsystem, wire feed subsystem, and said instrumentation subsystem.

Taminger, Karen M.↗

Wind-Optimal Trajectories for Multirotor eVTOL Aircraft on UAM Missions

Distributed electric propulsion powered electric vertical takeoff and landing aircraft are expected to enable urban air mobility. Low specific energy of onboard lithium-ion polymer batteries and wind conditions impose constraints on flight endurance. Therefore, from the safety and efficiency perspective, planning and flying minimum energy trajectories are important.The primary motivation for this paper is to determine if there is an operational benefit to flying wind-optimal trajectories for short flights (less than 60 miles) in the urban environment. This study employs wind-optimal trajectories for a NASA-proposed conceptual multirotor aircraft flight in the urban environment. The optimal control model presented includes a wind model for quantifying the effect of wind on the trajectory. The optimal control problem is numerically solved using the direct method. Energy consumption and flight duration flying wind-optimal trajectories between origins and destinations in a metropolitan area are compared with energy consumption and flight duration flying on the great-circle paths between the same origin and destination pairs to determine the operational benefit of wind-optimal routing for short flights.The flight duration results for different scenarios are validated using a simulation tool designed and developed by NASA for exploring advanced air traffic management concepts. In summary,this research study suggests that for short flights in an urban environment, the wind-optimal trajectories have a very slight (insignificant) operational advantage over the great-circle trajectories in terms of energy consumption and flight duration. As expected, headwinds and tailwinds along the route of flight have a significant impact on energy consumption and flight duration.

Urban Air Mobility↗

Parametric Study of State-of-Charge for an Electric Aircraft in Urban Air Mobility

The envisioned concept of urban air mobility is anticipated to support passenger transportation, cargo delivery, and emergency services in major metropolitan areas with increasing autonomy levels in the future. Distributed electric propulsion powered electric vertical takeoff and landing aircraft are expected to enable urban air mobility. However, the low specific energy of onboard lithium-ion polymer batteries and wind conditions impose constraints on flight endurance. Therefore, to enable autonomous urban air mobility operations using electric aircraft, one of the critical steps from a safety and efficiency perspective is to understand how various operational and environmental conditions impact the state-of-charge of the onboard lithium-ion polymer batteries. This research performs a parametric study of the state-of-charge for a NASA-proposed conceptual multirotor aircraft flight in the urban environment. The parameters considered for the parametric analysis are cruise airspeed, cruise altitude, climb and descent profiles, wind conditions (wind magnitude, wind direction relative to the route, and wind magnitude uncertainty), and required time of arrival.

Urban Air Mobility↗

Parametric Study of State of Charge for an Electric Aircraft in Urban Air Mobility

The envisioned concept of urban air mobility is anticipated to support passenger transportation, cargo delivery, and emergency services in major metropolitan areas with increasing autonomy levels in the future. Distributed electric propulsion powered electric vertical takeoff and landing aircraft are expected to enable urban air mobility. However, the low specific energy of onboard lithium-ion polymer batteries and wind conditions impose constraints on flight endurance. Therefore, to enable autonomous urban air mobility operations using electric aircraft, one of the critical steps from a safety and efficiency perspective is to understand how various operational and environmental conditions impact the state-of-charge of the onboard lithium-ion polymer batteries. This research performs a parametric study of the state-of-charge for a NASA-proposed conceptual multirotor aircraft flight in the urban environment. The parameters considered for the parametric analysis are cruise airspeed, cruise altitude, climb and descent profiles, wind conditions (wind magnitude, wind direction relative to the route, and wind magnitude uncertainty), and required time of arrival.

Urban Air Mobility↗

Simulation Studies for an Urban Air Mobility Aircraft using Hardware-In-Loop Experiments

Urban Air Mobility seeks to transport passengers, deliver cargo, and provide emergency transportation in major metropolitan areas. This will be accomplished with distributed electric-powered vertical takeoff and landing aircraft. The low specific energy of the current generation lithium-ion battery packs limit the operational range of electric aircraft. Limited range impacts safety by reducing the time available for analyzing and responding to errors and failures, and limiting the ability to fly to an alternative landing area or return to base. It is therefore critical to understand flight operational and environmental conditions that impact the onboard lithium-ion polymer battery pack’s health. With this as the motivation, experimental procedure in a laboratory setting, and results of the experiments performed on battery packs subject to power draw corresponding to power required during the different phases of flight of a NASA conceptual quadrotor aircraft in simulation are described. The fully charged battery is allowed to discharge at specific C-rates based on the power draw profile and the current and voltages are recorded. Observed results under different operating conditions and mission profiles are discussed.

UAM↗

Validation of International Space Station Electrical Performance Model via On-orbit Telemetry

The first U.S. power module on International Space Station (ISS) was activated in December 2000. Comprised of solar arrays, nickel-hydrogen (NiH2) batteries, and a direct current power management and distribution (PMAD) system, the electric power system (EPS) supplies power to housekeeping and user electrical loads. Modeling EPS performance is needed for several reasons, but primarily to assess near-term planned and off-nominal operations and because the EPS configuration changes over the life of the ISS. The System Power Analysis for Capability Evaluation (SPACE) computer code is used to assess the ISS EPS performance. This paper describes the process of validating the SPACE EPS model via ISS on-orbit telemetry. To accomplish this goal, telemetry was first used to correct assumptions and component models in SPACE. Then on-orbit data was directly input to SPACE to facilitate comparing model predictions to telemetry. It will be shown that SPACE accurately predicts on-orbit component and system performance. For example, battery state-of-charge was predicted to within 0.6 percentage points over a 0 to 100 percent scale and solar array current was predicted to within a root mean square (RMS) error of 5.1 Amps out of a typical maximum of 220 Amps. First, SPACE model predictions are compared to telemetry for the ISS EPS components: solar arrays, NiH2 batteries, and the PMAD system. Second, SPACE predictions for the overall performance of the ISS EPS are compared to telemetry and again demonstrate model accuracy.

Jannette, Anthony G.↗

A study of the spatial scales of discrete polar auroral arcs

Recent theoretical works have dealt with the identification and evaluation of the physical processes that determine the characteristic scale sizes of discrete auroral arcs. It is broadly acknowledged that a characteristic spatial width of approximately 100 km (at ionospheric heights) results naturally from the ionospheric mapping of the high-altitude magnetospheric convection electric field. However, recent analysis of the spatial power spectral distributions of electric and magnetic field variations has revealed structure at much smaller spatial scales. In this analysis, precipitating auroral electron data from the J-package sensor on the Defense Meteorological Satellite Program satellite is used to study the spatial scale sizes and size distributions of polar auroral arcs. A monotonically decreasing inverse-wavelength spectrum with a slope near unity is common, with no strictly preferred scale sizes, although the scale spectrum does flatten at scales larger than approximately 100 to 200 km. Typical observed widths of the auroral arcs tend to be much smaller than the resistive scale length, and the observed widths do not have a strong dependence on local ionospheric parameters.

Gorney, David J.↗

Automated Power-Distribution System

Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

Thomason, Cindy↗

Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

Luette, J. P.↗

An architecture for object-oriented intelligent control of power systems in space

A control system for autonomous distribution and control of electrical power during space missions is being developed. This system should free the astronauts from localizing faults and reconfiguring loads if problems with the power distribution and generation components occur. The control system uses an object-oriented simulation model of the power system and first principle knowledge to detect, identify, and isolate faults. Each power system component is represented as a separate object with knowledge of its normal behavior. The reasoning process takes place at three different levels of abstraction: the Physical Component Model (PCM) level, the Electrical Equivalent Model (EEM) level, and the Functional System Model (FSM) level, with the PCM the lowest level of abstraction and the FSM the highest. At the EEM level the power system components are reasoned about as their electrical equivalents, e.g, a resistive load is thought of as a resistor. However, at the PCM level detailed knowledge about the component's specific characteristics is taken into account. The FSM level models the system at the subsystem level, a level appropriate for reconfiguration and scheduling. The control system operates in two modes, a reactive and a proactive mode, simultaneously. In the reactive mode the control system receives measurement data from the power system and compares these values with values determined through simulation to detect the existence of a fault. The nature of the fault is then identified through a model-based reasoning process using mainly the EEM. Compound component models are constructed at the EEM level and used in the fault identification process. In the proactive mode the reasoning takes place at the PCM level. Individual components determine their future health status using a physical model and measured historical data. In case changes in the health status seem imminent the component warns the control system about its impending failure. The fault isolation process uses the FSM level for its reasoning base.

Holmquist, Sven G.↗

Electric power for space satellites

The development of electric power systems for satellites is discussed as an evolutionary process requiring the integration of power generation, power storage, and power control and distribution. The growth of space electric power systems is traced. The capabilities and limitations of the various elements (i.e. silicon solar cells) are discussed together with their impact on future technological growth.

Mackenzie, C. M.↗

AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side redundancies and including emergency generators on both ac and dc sides is proposed. The generation frequency is 400 Hz mostly because of the technology maturity at this frequency in the aerospace industry. Power will be distributed to several ac load distribution buses through solid state variable speed, constant frequency converters on the ac side. A segmented dc ring bus supplied from ac/dc converters and with the capability of connecting/disconnecting the segments will supply power to multiple de load distribution buses. The system will have the capability of reverse flow from dc to ac side in the case of an extreme emergency on the main ac generation side.

Chowdhury, Badrul H.↗

Selection and development of small solar thermal power applications

The paper discusses the approach of the JPL Point Focusing Thermal and Electric Power Applications Project to selecting and developing applications for point-focusing distributed-receiver solar thermal electric power systems. Six application categories are defined. Results of application studies of U.S. utilities are presented. The economic value of solar thermal power systems was found to range from $900 to $2100/kWe in small community utilities of the Southwest.

Bluhm, S. A.↗

Multilayered Functional Insulation System (MFIS) for AC Power Transmission in High Voltage Hybrid Electrical Propulsion

High voltage hybrid electric propulsion systems are now pushing new technology development efforts for air transportation. A key challenge in hybrid electric aircraft is safe high voltage distribution and transmission of megawatts of power (>20 MW). For the past two years, a multidisciplinary materials research team at NASA Glenn Research Center has investigated the feasibility of distributing high voltage power on future hybrid electric aircraft. This presentation describes the team's approach to addressing this challenge, significant technical findings, and next steps in GRC's materials research effort for MW power distribution on aircraft.

high voltage power transmission↗