Search NASA⌕ Search

SEARCH · Search NASA

Results for “end use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Evolving Electricity Supply and Demand to Achieve Net-Zero Emissions: Insights from the EMF-37 Study

This paper explores the role of electricity in achieving economy-wide net-zero CO2 emissions by 2050 in the United States based on results from 17 models as part of the 37th Stanford Energy Modeling Forum (EMF-37). In the study's Net-Zero scenario, the models use diverse pathways to achieve net-zero emissions by 2050, with gross energy-related residual emissions ranging from 17.2 to 66.6 % of 2020 levels. Electricity consistently emerges as central to achieving net-zero, with models projecting rapid electrification of end-uses and rapidly declining CO2 intensity of electricity. However, the extent of electrification and the technology mix to decarbonize the power sector vary considerably across models. In the Net-Zero scenario, electricity is projected to evolve from ~20 % of final energy in 2020 to 17-63 % in 2050 across the models driven by electrification in all sectors-buildings, industry, and transportation-and, to a lesser extent by direct air capture. By 2050, total electricity consumption increases by 24-176 % (relative to 2020), accompanied by significant expansion in renewable electricity production. Together, solar and wind generation grows by 175-834 %, supplying 45-90 % of total electricity in 2050, with wind achieving slightly higher shares than solar. Electricity storage technologies are deployed at scale to support wind and solar generation. The electricity generation mix varies across models: some project almost complete reliance on renewables, while others see a substantial role for natural gas, often with carbon capture and storage. This paper synthesizes the rich diversity of modeling approaches and results, highlighting differing views on how key drivers of electricity demand and supply might evolve.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Data-Driven Algorithm for Enabling Delay Tolerance in Resilient Microgrid Controls Using Dynamic Mode Decomposition

The increased implementation of smart grid technologies in the power distribution grid presents unique opportunities that enable resiliency, but also brings challenges motivating needs for novel solutions and mitigation techniques. The bi-directional power and data flow allow for the grid to operate with increased resiliency, which is the ability to avoid discontinuity of service to end-use loads during extreme events. However, in applications where control of the distribution grid or microgrid relies on communication networks, the degradation of communication systems in the form of loss or high latency can cause maloperation and result in loss of end-use loads. Here this paper presents a novel framework to enable delay tolerance of centralized microgrid control schemes to mitigate communication system latency impacts and guarantee successful control action. We demonstrate the delay tolerance on a control scheme that operates a battery energy storage system (BESS) to offset the sudden loss of generation and maintain system frequency. During periods of severely degraded communication system performance, the proposed delay-tolerant algorithm compensates for the latency by utilizing a data-driven model generated at the device level using dynamic mode decomposition (DMD) to determine the performance of the communications. The DMD technique predicts the system’s frequency using device-level terminal measurements and provides updated control signals. The HELICS cosimulation platform evaluates the cyber-physical interaction of the power system model in GridLAB-D, the centralized control agent in Python, and the discrete network model in NS-3. The framework is tested and validated on the IEEE-123 node system modified to represent a networked remote microgrid model, and the results show an improvement in the dynamic performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

MEGASTAR: The Meaning of Energy Growth: An Assessment of Systems, Technologies, and Requirements

A methodology for the display and analysis of postulated energy futures for the United States is presented. A systems approach that includes the methodology of technology assessment is used to examine three energy scenarios--the Westinghouse Nuclear Electric Economy, the Ford Technical Fix Base Case and a MEGASTAR generated Alternate to the Ford Technical Fix Base Case. The three scenarios represent different paths of energy consumption for the present to the year 2000. Associated with these paths are various mixes of fuels, conversion, distribution, conservation and end-use technologies. MEGASTAR presents the estimated times and unit requirements to supply the fuels, conversion and distribution systems for the postulated end uses for the three scenarios and then estimates the aggregate manpower, materials, and capital requirements needed to develop the energy system described by the particular scenario. The total requirements and the energy subsystems for each scenario are assessed for their primary impacts in the areas of society, the environment, technology and the economy.

Source record↗

MEGASTAR: The meaning of growth. An assessment of systems, technologies, and requirements

A methodology for the display and analysis of postulated energy futures for the United States is presented. A systems approach methodology including the methodology of technology assessment is used to examine three energy scenarios--the Westinghouse Nuclear Electric Economy, the Ford Technical Fix Base Case and a MEGASTAR generated Alternate to the Ford Technical Fix Base Case. The three scenarios represent different paths of energy consumption from the present to the year 2000. Associated with these paths are various mixes of fuels, conversion, distribution, conservation and end-use technologies. MEGASTAR presents the estimated times and unit requirements to supply the fuels, conversion and distribution systems for the postulated end uses for the three scenarios and then estimates the aggregate manpower, materials, and capital requirements needed to develop the energy system described by the particular scenario.

Source record↗

Marine Renewable Energy Applications for Restorative Ocean Farming: Kelp

Kelp farming and kelp forest restoration have both been proposed as a solution to locally decrease the impacts of ocean acidification and eutrophication, often with co-benefits to other forms of aquaculture and mariculture. Compared to global markets, the kelp industry in the United States is still in its early phases, with the first commercial kelp farm founded in Casco Bay, Maine in 2010. Since then, interest and effort in kelp production has been increasing, with farms now present in Maine, New Hampshire, Connecticut, Rhode Island, Massachusetts, New York, Washington, and Alaska. Many research projects are underway in the United States to explore benefits of 3D ocean farming, tackle logistical problems of working in the ocean, autonomous farming, and explore viable end uses for kelp products. In seaweed farming, to remove the stored carbon or excess nutrients from the system, the biomass needs to be harvested at the optimal time to avoid the release of CO 2 that comes with decomposition. Timing of the harvest is also important for maximum crop yield, which can vary based on the final product. Additional monitoring needs can include a variety of water quality metrics, growth measurements, and visuals to ensure the health of the farm, comply with permits, support operations and maintenance functions. The variables measured may vary by desired end use of the product, location of farm, and operational design. Monitoring all of these parameters requires specialized devices that can be costly and challenging to maintain. Monitoring devices often face power and logistical constraints that could prevent kelp farmers from adopting these technologies or receiving accurate, efficient monitoring to assess ecosystem benefits and valuation. Marine energy has been identified as a possible power source for these devices. This project investigates the power needs for conducting kelp farm environmental monitoring compared with the available marine energy resource to evaluate if locally generated ocean energy could provide a solution to these monitoring challenges and benefit kelp farmers. This process was structured as follows: 1. Define what data is needed for farmers and their communities through desk research and interviews with end users. 2. Identify sensors and power requirements currently in use or available for commercial purchase. 3. Analyze current kelp and other mariculture farm locations for the potential marine energy resource. 4. Analyze farm designs and associated structures to make recommendations for marine energy design. 5. Quantify value that investment in sensors could provide in terms of carbon credit possibilities.

09 BIOMASS FUELS↗

Simulation and Optimization of Volatile Fatty Acid Upgrading Strategies for Sustainable Transportation Fuel Production

The multicomponent nature of and variability of biomass makes chemical upgrading via a single process stream to a single end use infeasible for most feedstocks. A more promising approach is to identify upgrading strategies (encompassing bioprocessing, catalysis, and separations) which valorize varied biomass fractions to distinct products to which each is best suited. A robust procedure to carry out this goal should incorporate comparison of various upgrading procedures as well as suitability of products to a slate of identified end uses. We applied this strategy to one biomass-derived feedstock, volatile fatty acids (VFAs) derived from wet waste arrested anaerobic digestion, by developing a computer program, VFA Upgrading to Liquid Transportation fUels Refinery Estimation (VULTURE) which evaluates VFA catalytic upgrading to liquid transportation fuels. VULTURE considers multiple separations, catalysis (ketonization, hydrogenation), and fuel application options, generating hundreds of candidate scenarios for a given VFA stream, then selects several promising strategies that optimize bio-content of products with properties best suited for target fuel types. We find that VFAs are upgraded most efficiently when separate light alcohol (C3-6) and heavy hydrocarbon or alcohol (C7-13) fractions are targeted to create gasoline and heavy-duty (diesel or jet) fuels or fuel blends. Surrogate property testing of VULTURE-recommended fuels reveals that most predictive models employed are robust, while rigorous process simulation shows that the simple unit operation assumptions used in VULTURE are largely accurate, especially for heavy-duty fuel synthesis. Techno-economic and life-cycle analyses show that VFA-derived fuels are profitable and have dramatically (=57%) lower carbon intensities than fossil analogs.

BIOMASS FUELS↗

A life cycle and product type based estimator for quantifying the carbon stored in wood products

Background: Timber harvesting and industrial wood processing laterally transfer the carbon stored in forest sectors to wood products creating a wood products carbon pool. The carbon stored in wood products is allocated to end-use wood products (e.g., paper, furniture), landfill, and charcoal. Wood products can store substantial amounts of carbon and contribute to the mitigation of greenhouse effects. Therefore, accurate accounts for the size of wood products carbon pools for different regions are essential to estimating the land-atmosphere carbon exchange by using the bottom-up approach of carbon stock change. Results: To quantify the carbon stored in wood products, we developed a state-of-the-art estimator (Wood Products Carbon Storage Estimator, WPsCS Estimator) that includes the wood products disposal, recycling, and waste wood decomposition processes. The wood products carbon pool in this estimator has three subpools: (1) end-use wood products, (2) landfill, and (3) charcoal carbon. In addition, it has a user-friendly interface, which can be used to easily parameterize and calibrate an estimation. To evaluate its performance, we applied this estimator to account for the carbon stored in wood products made from the timber harvested in Maine, USA, and the carbon storage of wood products consumed in the United States. Conclusion: The WPsCS Estimator can efficiently and easily quantify the carbon stored in harvested wood products for a given region over a specific period, which was demonstrated with two illustrative examples. In addition, WPsCS Estimator has a user-friendly interface, and all parameters can be easily modified.

54 ENVIRONMENTAL SCIENCES↗

Composition, Emissions, and Air Quality Impacts of Hazardous Air Pollutants in Unburned Natural Gas from Residential Stoves in California

The presence of hazardous air pollutants (HAPs) entrained in end-use natural gas (NG) is an understudied source of human health risks. We performed trace gas analyses on 185 unburned NG samples collected from 159 unique residential NG stoves across seven geographic regions in California. Our analyses commonly detected 12 HAPs with significant variability across region and gas utility. Mean regional benzene, toluene, ethylbenzene, and total xylenes (BTEX) concentrations in end-use NG ranged from 1.6–25 ppmv–benzene alone was detected in 99% of samples, and mean concentrations ranged from 0.7–12 ppmv (max: 66 ppmv). By applying previously reported NG and methane emission rates throughout California’s transmission, storage, and distribution systems, we estimated statewide benzene emissions of 4,200 (95% CI: 1,800–9,700) kg yr –1 that are currently not included in any statewide inventories–equal to the annual benzene emissions from nearly 60,000 light-duty gasoline vehicles. Additionally, we found that NG leakage from stoves and ovens while not in use can result in indoor benzene concentrations that can exceed the California Office of Environmental Health Hazard Assessment 8-h Reference Exposure Level of 0.94 ppbv–benzene concentrations comparable to environmental tobacco smoke. This study supports the need to further improve our understanding of leaked downstream NG as a source of health risk.

42 ENGINEERING↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

Impacts of the Inflation Reduction Act on Consumer Energy Expenditures

The Inflation Reduction Act introduced or expanded a suite of federal tax credits for clean electricity generation and customer adoption of electric (and other highly efficient) end-use equipment. These incentives are expected to drive changes in both the electricity generation mix and demand for electricity (especially for space heating and light-duty vehicles), which are highly interconnected. In this session, Caitlin Murphy, Group Manager and Senior Analyst in NREL's Strategic Energy Analysis Center, will present findings from her team's recent state-level analysis on the combined effects of various IRA incentives on customer expenditures for electricity, natural gas, and gasoline. She will present and explain the regional variations observed in their analysis, based on interactions between end-use equipment cost and performance and projections for future energy prices.

air source heat pump↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingsBench: A Benchmark for Universal Building Load Forecasting [SWR-23-51]

The residential and commercial building stock in the United States is responsible for a significant percentage of energy consumption and greenhouse gas emissions. Electrification of end-uses, as well as decarbonizing the electrical grid through renewable energy sources such as solar and wind, constitutes the pathway to zero-emission buildings. Forecasting day-ahead building energy consumption is an integral part of this solution. Currently, specialized forecasting models are hand-made for each individual building, which is time-consuming, expensive, and leads to duplicated efforts. BuildingsBench is a Python software framework for training and comparing generalized machine learning models for universal building load forecasting. This challenge tasks a single foundational model to generalize its forecasts for a wide variety of buildings, across geographic regions, building types, weather patterns, and more. This software provide code for pre-training such models and subsequently evaluating their performance on a suite of hundreds of diverse real and synthetic buildings. BuildingsBench is a platform for: - Large-scale pretraining with the synthetic Buildings-900K dataset for short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock and is extracted from the NREL End-Use Load Profiles database. - Benchmarking on two tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. We provide an index-based PyTorch Dataset for large-scale pretraining, easy data loading for multiple real building energy consumption datasets as PyTorch Tensors or Pandas DataFrames, simple (persistence) to advanced (transformer) baselines, metrics management, and more.

Emami, Patrick↗