RouteE: A Vehicle Energy Consumption Prediction Engine

The emergence of connected and automated vehicles and smart cities technologies create the opportunity for new mobility modes and routing decision tools, among many others. To achieve maximum mobility and minimum energy consumption, it is critical to understand the energy cost of decisions and optimize accordingly. The Route Energy prediction model (RouteE) enables accurate estimation of energy consumption for a variety of vehicle types over trips or sub-trips where detailed drive cycle data are unavailable. Applications include vehicle route selection, energy accounting and optimization in transportation simulation, and corridor energy analyses, among others. The software is a Python package that includes a variety of pre-trained models from the National Renewable Energy Laboratory (NREL). However, RouteE also enables users to train custom models using their own data sets, making it a robust and valuable tool for both fast calculations and rigorous, data-rich research efforts. The pre-trained RouteE models are established using NREL's Future Automotive Systems Technology Simulator paired with approximately 1 million miles of drive cycle data from the Transportation Secure Data Center, resulting in energy consumption behavior estimates over a representative sample of driving conditions for the United States. Validations have been performed using on-road fuel consumption data for conventional and electrified vehicle powertrains. Transferring the results of the on-road validation to a larger set of real-world origin-destination pairs, it is estimated that implementing the present methodology in a green-routing application would accurately select the route that consumes the least fuel 90% of the time. The novel machine learning techniques used in RouteE make it a flexible and robust tool for a variety of transportation applications.

47 OTHER INSTRUMENTATION↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Data-driven estimation of energy consumption for electric bus under real-world driving conditions

Reliable and accurate estimation of an electric bus’s instantaneous energy consumption is critical in evaluating energy impacts of planning and control of electric bus operations. In this study, we developed machine learning-based long short-term memory (LSTM) and artificial neural network (ANN) models to estimate 1 Hz energy consumption of electric buses based on continuous monitoring data of electric buses in Chattanooga, Tennessee, in 2019 and 2020. We propose a data-partitioning algorithm to separate energy charging and discharging modes before applying data-driven estimation models. Here, a K-fold cross-validation-based model selection process was conducted to identify the optimal model structure and input variables in terms of prediction accuracy. The estimation results show the predicted mean absolute percentage error rates of LSTM and ANN models were 3% and 5%, respectively. We compared the proposed models with existing models in the literature based on the same testing data to demonstrate the predictability of our models.

Artificial neural network↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling energy‐efficient manufacturing of pharmaceutical solid oral dosage forms via integrated techno‐economic analysis and advanced process modeling

Abstract The global pharmaceutical industry is a trillion‐dollar market. However, the pharmaceutical sector often lags in manufacturing innovation and automation which limits its potential to maximize energy efficiency. The integration of techno‐economic analysis (TEA) with advanced process models as part of an overarching smart manufacturing platform, can help industries create business models, which can be adapted for manufacturing to reduce energy consumption and operating costs while ensuring product quality which can further enable a more sustainable process operation. In this study, a rational design of experiment on three unit‐operations (wet granulation, drying, and milling) was performed on a batch (case 1) and continuous (case 2) pharmaceutical process to obtain experimental data. Process models for predicting product quality and energy efficiency of each of the three‐unit operations were developed. The experimental data were used to validate the models and good agreement was observed. The energy consumption of each unit operation was calculated using statistical models relating the power consumption and the process parameters. The developed process models and energy models were further integrated into a TEA framework, which quantified the energy and monetary cost of manufacturing for both batch and continuous manufacturing cases. With this integrated framework, energy costs savings of ~33% was obtained in the continuous manufacturing process (case 2) over the batch process (case 1).

Sampat, Chaitanya↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

A mathematical design framework for membrane pre-concentration in energy-efficient recovery of fermentation products

Due to the dilute nature of products manufactured via fermentation and cell-free bioprocessing, dewatering is a common unit operation in downstream processing (DSP) for bioproduct recovery, but it is typically energy intensive. To improve DSP energy efficiency for bio-based small molecules, integrating high-pressure membrane pre-concentration is a promising process option. However, this approach is typically constrained by a tradeoff between concentration factor (CF) and product recovery (PR), namely increasing the CF typically results in greater product loss, and vice versa. Here we developed a model that enables process design guidelines to: (i) identify scenarios in which the additional energy consumption and product loss from membrane pre-concentration are justified for use in DSP, and (ii) determine the optimal CF that minimizes process specific energy consumption. We compared the energy consumption of high-pressure membrane-integrated processes to evaporation-only processes and applied the model to an experimental case study for the separation and purification of butyric acid from Clostridium tyrobutyricum fermentation using an in situ product recovery (ISPR) process. The model estimated that integrating a tangential-flow reverse osmosis (RO) pre-concentration unit could reduce process energy consumption up to 45%. The use of advanced membrane pre-concentration technologies, such as negative rejection membranes and organic solvent reverse osmosis (OSRO), have the potential to further reduce the overall process specific energy consumption up to 96%, projected based on modeling. Overall, membrane pre-concentration, especially when strategically integrated prior to an evaporation step with optimized process conditions, holds significant potential for improving DSP energy efficiency, particularly in applications requiring substantial solvent removal for product recovery from dilute mixtures.

09 BIOMASS FUELS↗

Multimodal Freight Energy Model for Emerging Freight Technology Analysis

While freight movement represents a small portion of the volume in the transportation sector, they are a critical contributor for energy consumed in that sector. To reduce logistics costs, energy consumption and negative environmental impact, emerging technologies, such as digitalization of logistics and alternative powertrain, have been developed and extended applications in freight. These trends are expected to grow and provide opportunities for greater efficiencies in freight movement and corresponding energy use. Still, the complexity of freight systems present challenges in evaluating these benefits, especially in the multimodal inter-city freight. Addressing the research need, this paper develops a multimodal freight energy modeling framework for the analysis of emerging freight technology scenarios. The framework is a bi-level optimization problem: network cost minimization problem (lower-level) and energy minimization problem (upper-level). The lower-level problem is a mode-path assignment problem in multimodal inter-city freight networks, where commodity-specific congestion effects on trans-shipment links are considered. For this model, an inverse modeling approach is applied to infer parameters of the lower-level model. The upper-level problem is designed to search for an optimal scenario that has the lowest energy consumption among different levels of technology applications. The proposed model is empirically tested to analyze truck load-pooling and multimodal load-pooling scenarios through stand-alone and mixed applications using freight shipments originating from or destined to the Chicago region. This framework can be used to explore the impact of emerging freight technologies on mode-path freight flow and energy consumption in the national multimodal freight network.

ADVANCED PROPULSION SYSTEMS↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating China’s Passenger Vehicle Market under the Vehicle Policies of 2021–2023

China is well known for its determination on large-scale vehicle electrification, which currently is mainly driven by fuel economy and electric vehicle policies mixed with the extensive charging infrastructure support and monetary incentives from the government. This study adopted the New Energy and Oil Consumption Credits (NEOCC) model 2020 version, a vehicle policy analysis tool developed by the Oak Ridge National Laboratory, in order to systematically quantify the potential impacts of the “Passenger Cars Corporate Average Fuel Consumption and New Energy Vehicle Credit Regulation”, which is a revised version released in June 2020 for the timeframe 2021–2023, the so-called dual credit policy (2021–2023). It was found that, under the dual credit policy (2021–2023), the sales of hybrid electric vehicles could reach 0.91 million by the end of 2023, which would increase much faster than they did in 2018–2020. The annual sales share of plug-in electric vehicles (PEVs) could reach 11.7%, and the PEV stocks could achieve 11.70 million by the end of 2023 if it keeps the expansion to the level of how it was in 2017. In addition, the BEVs with long electric range (such as 400 km) and the plug-in hybrid electric SUVs could be the most popular PEV types.

33 ADVANCED PROPULSION SYSTEMS↗

Forecasting the Impact of Dual-credit Policy (2021-2023) on China's Electric Vehicle Market

China is well known for its ambition on large-scale vehicle electrification which currently is mainly driven by fuel economy and electric vehicle policies. This study adopts the New Energy and Oil Consumption Credits (NEOCC) model, a vehicle policy analysis tool developed by the Oak Ridge National Laboratory, to systematically quantify the potential impacts of the “Passenger Cars Corporate Average Fuel Consumption and New Energy Vehicle Credit Regulation” which was released in June 2020 for the timeframe 2021-2023, so called dual-credit policy (2021-2023). It is found that, under the dual-credit policy (2021-2023), the sales of low fuel consumption conventional vehicles will increase faster than they were in 2018-2020, and the share of plug-in electric vehicles (PEVs) could reach 11.4% by 2023 if it keeps the expansion as it was in 2017. Besides, the BEVs with long electric range (such as 400 km) and the plugin hybrid SUVs would be the most popular PEV types.

Ou, Shawn↗

Particle scale impacts on deconstruction energy of pine residues

The goal of this Case Study was to quantify the impacts of variable moisture and ash on hammer mill throughput and energy consumption and on generation of fines that are not able to be fed to conversion, as compared to a status quo Base Case system. Also considered was convertible carbon content (minimum carbon specification) and maximum ash content and the delivered feedstock cost impacts of not being able to feed residue not meeting both specifications to the conversion reactor. Laboratory data on the impacts of input particle size and moisture content on the exit particle size were received from FCIC Subtask 5.2 from their single particle impact population balance modeling study. Additional throughput and energy consumption data were obtained from FCIC Subtask 5.2 for the same grinder with a 6 mm screen in place. These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Because the ash contents in the separated fines had not been analyzed in the laboratory at the time of the model runs, we chose to assume that the ash distributed proportionally with total mass into the overs and unders in the disk screen following grinding. Key takeaways from this Case Study are that it is significantly more cost effective to hammer mill the residue prior to drying, even though the grinder throughput is lower and energy consumption is higher versus drying first before grinding. An effect of dry grinding versus high moisture grinding is the production of higher amounts of fines during dry grinding, leading to significantly more of the ground feedstock being rejected by conversion for being below a minimum particle size. With wet grinding the system is still able to produce more preprocessed feedstock meeting the minimum particle size specification even though the instantaneous throughput is lower than for the case of grinding dry feedstock. Additionally, even without the higher fines production from dry grinding, the status quo would still be more costly than wet grinding because the material is rejected after the drying energy has already been input for the dry grinding case. Finally, significant reductions in drying energy are obtained by drying after grinding, and those reductions are of far greater magnitude than the grinding energy increase.

09 BIOMASS FUELS↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Ten questions concerning energy flexibility in buildings

Demand side energy flexibility is increasingly being viewed as an essential enabler for the swift transition to a low-carbon energy system that displaces conventional fossil fuels with renewable energy sources while maintaining, if not improving, the operation of the energy system. Building energy flexibility may address several challenges facing energy systems and electricity consumers as society transitions to a low-carbon energy system characterized by distributed and intermittent energy resources. For example, by changing the timing and amount of building energy consumption through advanced building technologies, electricity demand and supply balance can be improved to enable greater integration of variable renewable energy. Although the benefits of utilizing energy flexibility from the built environment are generally recognized, solutions that reflect diversity in building stocks, customer behavior, and market rules and regulations need to be developed for successful implementation. In this paper, we pose and answer ten questions covering technological, social, commercial, and regulatory aspects to enable the utilization of energy flexibility of buildings in practice. In particular, we provide a critical overview of techniques and methods for quantifying and harnessing energy flexibility. We discuss the concepts of resilience and multi-carrier energy systems and their relation to energy flexibility. We argue the importance of balancing stakeholder engagement and technology deployment. Finally, we highlight the crucial roles of standardization, regulation, and policy in advancing the deployment of energy flexible buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling charging infrastructure impact on the electric vehicle market in China

The plug-in electric vehicle (PEV) is deemed as a critical technological revolution, and the governments are imposing various vehicle policies to promote its development. Meanwhile, the market success of PEVs depends on many aspects. The study reported herein integrates one’s use of charging infrastructure at home, public place and workplace into the market dynamics analysis tool, New Energy and Oil Consumption Credits (NEOCC) model, to systematically assess the charging infrastructure (home parking ratio, public charging opportunity, and charging costs) impact on PEV ownership costs and analyze how the PEV market shares may be affected by the attributes of the charging infrastructure. Compared to the charging infrastructure, the impact of battery costs is incontrovertibly decisive on PEV market shares, the charging infrastructure is still non-negligible in the PEV market dynamics. The simulation results find that the public charging infrastructure has more effectiveness on promoting the PEV sales in the PEV emerging market than it does in the PEV mature market. However, the improvement of charging infrastructure does not necessarily lead to a larger PEV market if the charging infrastructure incentives do not coordinate well with other PEV policies. Besides, the increase of public charging opportunities has limited motivations on the growth of public PEV fleets, which are highly correlated to the number of public fast charging stations or outlets. It also finds that more home parking spaces can stimulate more sales of personal plug-in hybrid electric vehicles instead of personal battery electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗