Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy infrastructure siting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Modeling Electric Vehicle Charging Station Siting Suitability with a Focus on Equity

As adoption of electric vehicles increases, the infrastructure to charge them must keep pace. Determining where to add new charging infrastructure is a complex process subject to many factors, including electrical service availability, vehicle dwell time, the type(s) of drivers and vehicles the stations will serve, traffic levels and timing, and land ownership. In addition, advancing social equity is a current priority of federal efforts to invest in electric vehicle charging infrastructure. Conducting Multi-criteria Decision Analysis (MCDA) within Argonne’s Energy Zones Mapping Tool (EZMT) is a useful method for analyzing many of the factors that influence how suitable a location is for potentially adding new charging infrastructure, and we show how equity metrics can be included in the analysis. However, data limitations impose challenges to using MCDA to evaluate and prioritize locations. We use three examples to demonstrate how to use publicly available data and MDCA to analyze different siting objectives. Each example starts with defining a specific objective and ends with how to use the results to identify specific potential locations that could be investigated further. This analysis demonstrates how interested stakeholders can use the EZMT to run the example MCDA models defined in this study, modify them to suit their needs, or create new MCDA models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Framework for Quantitative Evaluation of Resilience Solutions: An Approach to Determine the Value of Resilience for a Particular Site

The paper provides the approach to providing a benefit cost analysis of energy and water alternatives to provide resilience to extreme events. The approach estimates the costs and returns of providing greater resilience of water and energy infrastructure. Extreme events are defined as high impact, low-frequency events such as, but not limited to, hurricanes, floods, storm surges and earthquakes. The provides justification for hardening water and energy infrastructure. Resilience is defined as “the ability to prepare for and to withstand an extreme event with little or no damage, or to recover more quickly from an extreme event.” The approach can be summarized as follows. The approach requires the development of a baseline with which to compare alternatives. The baseline is used to evaluate the baseline’s resilience to hazards through the probability of the hazard(s), the likelihood of damage from that the hazard through a vulnerability analysis, and the consequence to calculate a cost of the damage. The approach then evaluates proposed mitigation alternatives that would improve the resilience of the system. Each alternative is evaluated based on probability of the hazard, probability of vulnerability and consequence to determine the reduced damage that each alternative presents. The approach includes any monetary and non-monetary benefits that can quantified for each of the alternatives. Non-quantifiable benefits are evaluated based on the relative importance of each alternative to the criteria used to determine how well the alternative meets the goals and objectives of the site/facility. Then, a life cycle cost analysis should be conducted for the baseline and alternatives. Finally, the results of the life cycle analysis should be presented in a decision matrix with cost, net present value, benefit/cost ratios, and any non-monetary criteria ranked to show how well the alternatives met the criteria, weighted with the decision maker’s weights and the results presented.

54 ENVIRONMENTAL SCIENCES↗

Tool-Based Case Studies on Strategic Deployment of Untapped Micro-Pumped Hydro Storage in Michigan

With most classical hydropower sites already utilized and the global push for rapid integration of renewable energy sources accelerating, there is a critical need to identify alternative energy storage solutions. Pumped hydro energy storage, which accounts for the vast majority of global grid-scale storage, remains one of the most cost-effective and long-duration storage technologies available. Hence, this study presents a novel tool designed to assess the untapped potential of inland lakes and reservoirs for micro-PSH, using Michigan’s relatively flat landscape as a case study due to its extensive but underutilized water infrastructure. To ensure accuracy and reliability, the tool incorporates extensive data gathered from authorized sources, covering more than 420 water facilities and potential reservoirs in the state. The tool evaluates key parameters such as horizontal and vertical distances, volume, and the total storage capacity of each reservoir. Its robust assessment framework integrates these metrics to evaluate each site’s potential. The tool’s intuitive interface and geospatial visualizations support actionable insights for planners and scalable deployment of distributed storage infrastructure.

13 HYDRO ENERGY↗

Integrated Hydrogen Energy Storage System (IHESS) for Power Generation (Final Report)

GTI Energy partnered with Praxair Inc., a subsidiary of Linde PLC (Praxair), the Center for Electromechanics at the University of Texas at Austin (CEM), Entergy Corporation (Entergy), Quanta Services (Quanta) and Mitsubishi Heavy Industries (MHI) to perform a feasibility study that determines the economic and technical feasibility of low-carbon hydrogen energy storage integrated with a site-specific fossil fuel asset to decarbonize electricity production using the Integrated Hydrogen Energy Storage System (IHESS). The proposed IHESS concept is novel, as it sought to leverage the existing natural gas infrastructure, hydrogen production and pipelines, existing underground hydrogen storage system and power plants in the Gulf Coast region to reduce carbon emissions and generate lowcarbon electricity. This study has shown that IHESS has a promising commercial outlook as the concept leverages existing natural gas infrastructure assets and hydrogen production and storage that are unique to the Texas gulf coast region. A key hurdle with hydrogen supply and transportation has been capital investment. By storing hydrogen in underground storage and delivering it as a fuel source during peak demand using the existing infrastructure minimizes the capital investment. Regional petrochemical producers who are actively seeking opportunities to reduce costs and lower emissions should find the IHESS concept very appealing.

03 NATURAL GAS↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EV Charging Infrastructure Energization: An Overview of Approaches for Simplifying Processes and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure and electricity. Growth in electricity demand from EV charging, coupled with growth in other sectors like data centers and electrification of other sectors, is impacting electricity infrastructure and load service request processes after two decades of relatively flat electricity demand. While most electric vehicle charging occurs at home, enroute and depot charging for medium and heavy-duty vehicles, both using high-powered EV charging, are critical to meet electric vehicle operational needs. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have expressed distress that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions.

33 ADVANCED PROPULSION SYSTEMS↗

WELLS Interactive Application

The Wellbore Exploration and Location Logistic System (WELLS) Interactive Application is an interactive tool to enable easy exploration and visualization of the living national wellbore database (WELLS Database (https://edx.netl.doe.gov/dataset/wells_database)). The tool and underlying database were created and are maintained by the National Energy Technology Laboratory (NETL), providing visualization of the more than six million public wellbore records from more than 65 authoritative state, federal, and tribal resources. The WELLS Interactive Application serves up wellbore data from oil, gas, underground injection, research, geothermal, geotechnical, groundwater, and other types of wells in a single, standardized, unified system. In addition to the surface location of these wells, the underlying database combines select key attributes for features such as well age, depth, and operating status. The system also provides users with references back to the original sources used in this unified platform. The underlying data can be accessed through the WELLS Database: https://edx.netl.doe.gov/dataset/wells_database Additional Information: The WELLS Interactive Application (formerly titled CO2-Locate) enables visualization and access to the public wellbore records through an intuitive web-based mapping tool. The WELLS Interactive Application was designed to help users visualize, query, analyze, and download wellbore records. Public wellbore points are included as a layer in the Map page, called Public Wells. Additionally, a multivariate hexagon grid summarizing well density from proprietary well data, called Well Density, is included to identify data gaps between the public and proprietary well data. Filtering functionalities in the tool allow these two layers to be spatially filtered by state, county, or basin as well as by status, type, true vertical depth, and spud year. The WELLS Interactive Application also contains a Near Me tool can be used to search and explore wellbore data within a user-defined distance of a specified location on the map, which can also be downloaded. The Query tool allows users to query the selected or filtered wells in the Public Wells layer and export the data. For additional information on these tool functionalities, see the help documentation on the About page of the tool. Notes for Consideration: The Well Density layer provided in this application is derived from proprietary wellbore data, the records of which do not always contain values for key features (status, type, true vertical depth, or spud year). Therefore, data might not be available when layers are queried for all filter combinations. Additionally, visualizing layers and applying filters may take additional time to load (i.e., draw on the map) due to the large size of the data.

ccs↗

Clear Sky Toolkit: Decision Support User Guide

The Clear Sky Decision Support Template is a Microsoft Excel-based resource that enables users to screen and prioritize critical facilities for the addition of solar + storage. The Decision Support Template consolidates and streamlines the most relevant resources from the emergency management discipline, the electric utility sector, and national energy research institutions to assist in further site analysis and decision-making. The Decision Support Template is intended for use by local government and private sector decision-makers who aim to mitigate the effects of power outages on critical infrastructure, understand the potential for deploying photovoltaic (PV) and storage solutions on critical facilities, and align emergency management planning processes and utility needs with community resilience objectives. The Decision Support Template is divided into five modules that provide a structured, step-by-step approach users can follow and apply to unique circumstances. This process guides a more thorough and accurate assessment of a site's potential to accommodate a solar + storage system, provide grid benefits to utilities, and support community resilience and disaster mitigation for the broader region. After identifying potentially viable and preferred sites for solar + storage using the Decision Support Template, users should conduct a more detailed evaluation and consultation with a solar professional.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80 °C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80°C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

Energy Storage and the Law of Averages: How Storage Can Make Electricity More Affordable

The electric grid is planned, built, and operated to satisfy peak demand. But because peak demand only occurs for a few hours per year, customers end up paying full price for grid infrastructure that is only used for a small fraction of the year—an increasingly expensive proposition as peak demand continues to grow and more infrastructure is required to meet it. The emergence of cost-competitive energy storage technologies in recent years, however, offers the potential for a grid that is planned, built, and operated based on average demand. By strategically siting and operating energy storage throughout the electric grid, excess generation in low-demand periods can be captured and stored near customers, which then reduces the amount of electricity that needs to be generated and moved through the transmission and distribution systems during high-demand periods. This paper describes these potential benefits, supported by real-world examples of energy storage projects that have created cost savings, which points to the potential for profound and far-reaching reductions in the cost of electricity if energy storage technologies are deployed at scale throughout the electric grid. These examples will be of use to system planners and operators, utility regulators, decision makers, and stakeholders in those processes as they look for opportunities to reduce the cost of electricity in their respective systems and jurisdictions.

25 ENERGY STORAGE↗

Deliver Signal Phase and Timing (SPAT) for Energy Optimization of Vehicle Cohort Via Cloud-Computing and LTE Communications

Predictive Signal Phase and Timing (SPAT) message set is one fundamental building block for vehicle-to-infrastructure (V2I) applications such as Eco-Approach and Departure (EAD) at traffic signal controlled urban intersections. Among the two complementary communication methods namely short-range sidelink (PC5) and long-range cellular radio link (Uu), this paper documents the work with long-range link: the complete data chain includes connecting to the traffic signals via existing backhaul communication network, collecting the raw signal phase state data, predicting the signal state changes and delivering the SPAT data via a geofenced service to requests over HTTP protocols. An Application Programming Interface (API) library is developed to support various cellular data transmission reduction and latency improvement techniques. An emulation-based algorithm is applied to predict the traffic signal state changes to provide adequate prediction horizon (e.g., at minimum 2 minutes) for the cohort energy optimization. In fact, the same connectivity and SPAT delivery methodology has been applied to traffic signalized intersections nationwide in the United States upon public agency approvals for access to their firewalled traffic control network and signal control systems or directly to individual controllers. This methodology proves its effectiveness and potential for rapid growth of such SPAT deliveries at mass production scale without needing infrastructure hardware retrofit or excessive communication means. To support the energy optimization of light and heavy-duty vehicle cohorts of mixed automation and propulsion systems (EV, ICE and hybrid), the connection and SPAT deliveries at two sites were completed, including public roads in Washtenaw County, Michigan and closed track test sites at American Center for Mobility (ACM) in Ypsilanti, Michigan. However, only closed test track results at ACM will be presented in this paper. A neuroevolution based optimizer is developed and implemented to control the speed of a vehicle cohort with different propulsion systems and automation levels. Closed track tests showed significant energy savings of the cohort operation.

99 GENERAL AND MISCELLANEOUS↗

CO2 Streams Captured From Industrial Processes and Corrosion of Steel Pipelines

Based on the knowledge accumulated in the last decade related to Carbon Capture and Storage (CCS) processes and the identified gaps in knowledge, our study identifies and quantifies the key issues that impact the corrosion of materials, specifically relating to the integrity of structures for the CO2 transport pipelines and provides a better understanding of the materials’ compatibility with CO2 steams with impurities. This will help to understand the corrosion risks associated with CO2 transport and injection and leverage existing infrastructure or rebuild new pipeline networks to transport CO2 with impurities for EOR or geological storage.

CO2 corrosion↗