Search NASA⌕ Search

SEARCH · Search NASA

Results for “evolved gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Developing Mass Spectrometry for Water Quantitation and Volatiles Analysis from In-Situ Regolith

With a revived focus to create a sustainable hu-man presence on the moon, and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential [1]. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable in-dependent operation of missions while reducing the dependence on the complex supply chain created between the Earth, the moon and Mars. One of the most critical resources that has been identified for ISRU on the lunar surface is water [2]. Water is a versatile resource that can be used in various space operations, such as ra-diation shielding and conversion to oxygen (O2) for propellant [3,4]. One of the most water rich resources is thought to be within the regolith lo-cated in the permanently shadowed regions (PSR) of the Moon; several upcoming missions, such as PRIME-1 and VIPER, are already sched-uled to confirm this hypothesis [5,6]. However, there are currently no missions planned to quanti-fy the abudance of water at these regions. The quantity of water contained in the ice will inform and help the development of future ISRU plants and operation. Water and other volatile gases can be detect-ed upon controlled heating of icy lunar regolith for an accurate quantification of water. This method is similar to thermogravimetric analysis, which was used to analyze Apollo lunar regolith sam-ples. However, losses via sublimation/evaporation or contamination may have occurred with the samples due to the transit and exposure to the terrestrial environment. Furthermore, water would not be expected for these samples since they were not collected from a PSR. Thus, for more accurate results, icy lunar regolith should be ana-lyzed in situ to provide the most representative composition of both water and other volatile gas-es. The Light Water Analysis and Volatile Extract (LightWAVE) project aims to address this knowledge gap. A system has been developed to collect, heat and analyze evolved gases from lu-nar regolith on the lunar surface. The gases will be analyzed by a modified commercial off the shelf (COTS) residual gas analyzer (RGA) quad-rupole mass spectrometer. Evolved gases from heated regolith samples can be identified by the observed mass-to-charge (m/z) ratios, and the peak intensities correlate to the abundances of the observed gases for quantitation. Therefore, our group is developing a calibration methodology utilizing a COTS RGA to quantitate water from in-situ regolith samples on the lunar surface. The partial pressure of water and ideal gas law will be used to quantify the total water evolved from a regolith sample. Here we present our methodol-ogy for the design and calibration for water quan-titation using a COTS RGA.

Nilab Azim↗

Characterization of the corrosion resistance of several alloys to dilute biologically active solutions

Sulfate reducing bacteria and acid producing bacteria/fungi detected in hygiene waters increased the corrosion rate in aluminum alloy. Biologically active media enhanced the formation of pits on metal coupons. Direct observation of gas evolved at the corrosion sample, coupled with scanning electron microscopy (SEM) and energy dispersive x-ray analysis of the corrosion products indicates that the corrosion rate is increased because the presence of bacteria favor the reduction of hydrogen as the cathodic reaction through the reaction of oxygen and water. SEM verifies the presence of microbes in a biofilm on the surface of corroding samples. The bacterial consortia are associated with anodic sites on the metal surface, aggressive pitting occurs adjacent to biofilms. Many pits are associated with triple points and inclusions in the aluminum alloy microstructure. Similar bacterial colonization was found on the stainless steel samples. Fourier transform Infrared Spectroscopy confirmed the presence of carbonyl groups in pitted areas of samples exposed to biologically active waters.

Walsh, Daniel W.↗

Investigation of the Ignition and Burning of Materials in Space Cabin Atmospheres. Part 2: Ignition of a Combustible Mixture by a Hot Body with the Effects of Gravity

The ignition of a combustible gas mixture by a hot cylinder under the effect of a gravity field for steady state conditions is examined. For this purpose a horizontal cylinder is considered with gravity as a parameter together with a finite chemical reacting flow generated by free convection with the additional effect of diffusion. Both mass transfer and zero mass transfer cases are considered. By defining an ignition criterion the surface temperature and species are obtained from the analysis as a function of the gravity field. It is supposed that at the point of ignition the heat evolved in the gas is sufficiently high to attain a sustained combustion without any energy from the hot cylinder.

Lew, H. G.↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Stern, J. C.↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Mars↗

Numerical Analysis of Flow Evolution in a Helium Jet Injected into Ambient Air

A computational model to study the stability characteristics of an evolving buoyant helium gas jet in ambient air environment is presented. Numerical formulation incorporates a segregated approach to solve for the transport equations of helium mass fraction coupled with the conservation equations of mixture mass and momentum using a staggered grid method. The operating parameters correspond to the Reynolds number varying from 30 to 300 to demarcate the flow dynamics in oscillating and non-oscillating regimes. Computed velocity and concentration fields were used to analyze the flow structure in the evolving jet. For Re=300 case, results showed that an instability mode that sets in during the evolution process in Earth gravity is absent in zero gravity, signifying the importance of buoyancy. Though buoyancy initiates the instability, below a certain jet exit velocity, diffusion dominates the entrainment process to make the jet non-oscillatory as observed for the Re=30 case. Initiation of the instability was found to be dependent on the interaction of buoyancy and momentum forces along the jet shear layer.

Satti, Rajani P.↗

Applications of mass spectrometry techniques to autoclave curing of materials

Mass spectrometer analysis of gases evolved from polymer materials during a cure cycle can provide a wealth of information useful for studying cure properties and procedures. In this paper data is presented for two materials to support the feasibility of using mass spectrometer gas analysis techniques to enhance the knowledge of autoclave curing of composite materials and provide additional information for process control evaluation. It is expected that this technique will also be useful in working out the details involved in determining the proper cure cycle for new or experimental materials.

Smith, A. C.↗

VAPoR - Volatile Analysis by Pyrolysis of Regolith - an Instrument for In Situ Detection of Water, Noble Gases, and Organics on the Moon

We present the Volatile Analysis by Pyrolysis of Regolith (VAPoR) instrument design and demonstrate the validity of an in situ pyrolysis mass spectrometer for evolved gas analyses of lunar and planetary regolith samples. In situ evolved gas analyses of the lunar regolith have not yet been carried out and no atmospheric or evolved gas measurements have been made at the lunar poles. VAPoR is designed to do both kinds of measurements, is currently under development at NASA's Goddard Space Flight Center, and will be able to heat powdered regolith samples or rock drill fines up to 1400 C in vacuo. To validate the instrument concept, evolved gas species released from different planetary analogs were determined as a function of temperature using a laboratory breadboard. Evolved gas measurements of an Apollo 16 regolith sample and a fragment of the carbonaceous meteorite Murchison were made by VAPoR and our results compared with existing data. The results imply that in situ evolved gas measurements of the lunar regolith at the polar regions by VAPoR will be a very powerful tool for identifying water and other volatile signatures of lunar or exogenous origin as potential resources for future human exploration.

ten Kate, I. L.↗

Volatile Detections in Gale Crater Sediment and Sedimentary Rock: Results from the Mars Science Laboratory's Sample Analysis at Mars Instrument

This chapter discusses the detection of evolved gases from Gale crater sedimentary rock and eolian sediment by the Mars Science Laboratory rover's Sample Analysis at Mars (SAM) instrument. An overview is presented of the SAM instrument along with summary of key results from previous evolved gas analyses conducted at the Viking and Phoenix landing sites. The SAM measurements of evolved water, sulfur dioxide, carbon dioxide, carbon monoxide, oxygen, and nitrous oxide from Gale crater samples are presented. The phases responsible for the evolved gas detections and the implications for their presence are then evaluated. The water deuterium to hydrogen (D/H) ratio is discussed in context of understanding the degree of water loss from Mars. In the introduction of this book, we briefly explored the history of the exploration of Mars, where we discussed a major shift in the scientific thinking and public perception of the nature of the surface of Mars as new missions explored the Red Planet. The first observations of the surface sparked speculations of Mars being inhabited by intelligent beings, inspiring fantasy, science fiction, and, of course, further exploration. The turn came when Mariner 4 returned images of a lunar-like landscape, a monotonous basaltic world with many impact craters but no water, and therefore no prospects for life to find a habitable niche. The authors of the chapters of this book show how different our understanding of Mars is today from the historical Mariner 4 perspective!

Sutter, Brad↗

Measurements of Oxychlorine species on Mars

Mars landed and orbiter missions have instrumentation capable of detecting oxychlorine phases (e.g. perchlorate, chlorate) on the surface. Perchlorate (~0.6 wt%) was first detected by the Wet Chemistry Laboratory in the surface material at the Phoenix Mars Landing site. Subsequent analyses by the Thermal Evolved Gas Analyser aboard the same lander detected an oxygen release (~465°C) consistent with the thermal decomposition of perchlorate. Recent thermal analysis by the Mars Science Laboratory’s Sample Analysis at Mars instrument has also indicated the presence of oxychlorine phases (up to 1.2 wt%) in Gale Crater materials. Despite being at detectable concentrations, the Chemistry and Mineralogy (CheMin) X-ray diffractometer has not detected oxychlorine phases. This suggests that Gale Crater oxychlorine may exist as poorly crystalline phases or that perchlorate/chlorate mixtures exist, so that individual oxychlorine concentrations are below CheMin detection limits (~1 wt%). Although not initially designed to detect oxychlorine phases, reinterpretation of Viking Gas Chromatography/Mass Spectrometer data also suggest that oxychlorine phases are present in the Viking surface materials. Remote near-infrared spectral analyses by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument indicate that at least some martian recurring slope lineae (RSL) have spectral signatures consistent with the presence of hydrated perchlorates or chlorates during the seasons when RSL are most extensive. Despite the thermal emission spectrometer, Thermal Emission Imaging System, Observatoire pour la Minéralogie, l’Eau, les Glaces et l’Activité and CRISM detection of hundreds of anhydrous chloride (~10–25 vol%) deposits, expected associated oxychlorine phases (>5–10 vol%) have not been detected. Total Cl and oxychlorine data sets from the Phoenix Lander and the Mars Science Laboratory missions could be used to develop oxychlorine versus total Cl correlations, which may constrain oxychlorine concentrations at other locations on Mars by using total Cl determined by other missions (e.g. Viking, Pathfinder, MER and Odyssey). Development of microfluidic or ‘lab-on-a-chip’ instrumentation has the potential to be the next generation analytical capability used to identify and quantify individual oxychlorine species on future landed robotic missions to Mars.

Perchlorate↗

Analytical Instrument for Determining the Composition of Surface Materials and Ices in the Solar System: Mini-CIDEX to TIDE

Exobiology experiments onboard spacecraft or space probes often require the detection and identification of a wide range of chemical species over vast concentration ranges. These experiments must be carried out under severely limited conditions utilizing minimal resources. The mini-Cometary Ice and Dust Experiment (mini-CIDEX) instrument was developed for the chemical analysis of a cometary environment. It combined a Gas Chromatograph (GC) with a helium-based Ion Mobility Spectrometer (IMS) to fulfill the analytical requirements of a cometary exobiology mission: universal response; ppb sensitivity; low mass, volume, and consumables. Mini-CIDEX has evolved into the Titan Ice and Dust Experiment (TIDE) for the chemical analysis of the surface (liquid and solid) and lower atmosphere of Titan. The complexity of the analyses will be similar to the comet application with a heavier emphasis on organic molecules. TIDE is a component of the Titan Orbiter Aero-Rover Mission (TOAM) proposed to NASA's New Visions Program. Advances to the Mini-CIDEX technology for the Titan application and the analytical capabilities of TIDE will be presented.

Kojiro, Daniel R.↗

Onion-shell model of cosmic ray acceleration in supernova remnants

A method is devised to approximate the spatially averaged momentum distribution function for the accelerated particles at the end of the active lifetime of a supernova remnant. The analysis is confined to the test particle approximation and adiabatic losses are oversimplified, but unsteady shock motion, evolving shock strength, and non-uniform gas flow effects on the accelerated particle spectrum are included. Monoenergetic protons are injected at the shock front. It is found that the dominant effect on the resultant accelerated particle spectrum is a changing spectral index with shock strength. High energy particles are produced in early phases, and the resultant distribution function is a slowly varying power law over several orders of magnitude, independent of the specific details of the supernova remnant.

Bogdan, T. J.↗

Mars aqueous chemistry experiment

Mars Aqueous Chemistry Experiment (MACE) is designed to conduct a variety of measurements on regolith samples, encompassing mineral phase analyses, chemical interactions with H2O, and physical properties determinations. From these data, much can be learned or inferred regarding the past weathering environment, the contemporaneous soil micro-environments, and the general chemical and physical state of the Martian regolith. By analyzing both soil and duricrust samples, the nature of the latter may become more apparent. Sites may be characterized for comparative purposes and criteria could be set for selection of high priority materials on future sample return missions. The second year of the MACE project has shown significant progress in two major areas. MACE Instrument concept definition is a baseline design that has been generated for the complete MACE instrument, including definition of analysis modes, mass estimates and thermal model. The design includes multiple reagent reservoirs, 10 discrete analysis cells, sample manipulation capability, and thermal control. The MACE Measurement subsystems development progress is reported regarding measurement capabilities for aqueous ion sensing, evolved gas sensing, solution conductivity measurement, reagent addition (titration) capabilities, and optical sensing of suspended particles.

Clark, Benton C.↗

The Investigation of Perchlorate/Iron Phase Mixtures as A Possible Source of Oxygen Detected by the Sample Analysis at Mars (SAM) Instrument in Gale Crater, Mars

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover detected O2 and HCl gas releases from the Rocknest (RN) eolian bedform and the John Klein (JK) and Cumberland (CB) drill hole materials in Gale Crater. Chlorinated hydrocarbons have also been detected by the SAM quadrupole mass spectrometer (QMS) and gas chromatography/mass spectrometer (GCMS). These detections along with the detection of perchlorate (ClO4-) by the Mars Phoenix Lander's Wet Chemistry Laboratory (WCL) suggesting perchlorate is a possible candidate for evolved O2 and chlorine species. Laboratory thermal analysis of individual per-chlorates has yet to provide an unequivocal temperature match to the SAM O2 and HCl release data. These detections along with the detection of perchlorate (ClO4-) by the Mars Phoenix Lander's Wet Chemistry Laboratory suggested perchlorate is a possible candidate for evolved O2 and chlorine species. Laboratory thermal analysis of pure perchlorates has yet to provide an unequivocal temperature match to the SAM O2 and HCl release data. Analog laboratory analysis of iron mineralogy detected in Gale materials that was physically mixed with Ca- and Mg-perchlorate has been shown to catalyze lower O2 release temperatures and approach some SAM O2 release data. Instead of physical mixtures used in previous work, the work presented here utilized perchlorate solutions added to Fe phases. This technique allowed for perchlorate to come in closer contact with the Fe-phase and may more closely mimic Mars conditions where humidity can increase enough to cause deliquescence of the highly hygroscopic perchlorate phases. The objective of this work is to: 1) Utilize a laboratory SAM analog instrument to evaluate the O2 release temperatures from Mg- and Ca-perchlorates solutions applied to Fephases detetected in Gale Crate; and 2) Determine if perchlorate solutions can provide improved matches with the SAM O2 temperature release profiles.

Sutter, B.↗

The Investigation of Chlorates as a Possible Source of Oxygen and Chlorine Detected by the Sample Analysis at Mars (SAM) Instrument in Gale Crater, Mars

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover detect-ed O2 and HCl gas releases from the Rocknest (RN) eolian bedform and the John Klein (JK) and Cumberland (CB) drill hole materials in Gale Crater. Chlorinated hydrocarbons have also been detected by the SAM quadrupole mass spectrometer (QMS) and gas chromatography/mass spectrometer (GCMS). These detections along with the detection of perchlorate (ClO4-) by the Mars Phoenix Lander’s Wet Chemistry Laboratory (WCL) suggesting perchlorate is a possible candidate for evolved O2 and chlorine species. Laboratory thermal analysis of perchlorates has yet to provide an unequivocal temperature match to the SAM O2 and HCl release data. Iron mineralogy found in the Rocknest materials when mixed with Ca-perchlorate does cause O2 release temperatures to be closer match to the SAM O2 release data but more work is required in evaluating the catalytic effects of Fe mineralogy on perchlorate decomposition. Chlorates (ClO3-) are relevant Mars materials and potential O2 and Cl sources. The objective of this work is to evaluate the thermal decomposition of select chlorate (ClO3-) salts as possible sources of the O2 and HCl releases in the Gale Crater materials.

Sutter, B.↗

Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP). Resource Prospector is a lunar mission to investigate 'strategic knowledge gaps' (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis. After the RP lander safely delivers the rover to the lunar surface, the science team will guide the rover team on the first traverse plan. The neutron spectrometer (NS) and near infrared (NIR) spectrometer instruments will be used as prospecting tools to guide the traverse path. The NS will map the water-equivalent hydrogen concentration as low as 0.5% by weight to an 80 centimeter depth as the rover traverses the lunar landscape. The NIR spectrometer will measure surficial H2O/OH as well as general mineralogy. When the prospecting instruments identify a potential volatile-rich area during the course of a traverse, the prospect is then mapped out and the most promising location identified. An augering drill capable of sampling to a depth of 100 centimeters will excavate regolith for analysis. A quick assay of the drill cuttings will be made using an operations camera and NIR spectrometer. With the water depth confirmed by this first auguring activity, a regolith sample may be extracted for processing. The drill will deliver the regolith sample to a crucible that will be sealed and heated. Evolved volatiles will be measured by a gas chromatograph-mass spectrometer and the water will be captured and photographed. RP is a solar powered mission, which given the polar location translates to a relatively short mission duration on the order of 4-15 days. This short mission duration drives the concept of operations, instrumentation, and data analysis towards critical real time analysis and decision support. Previous payload field tests have increased the fidelity of the hardware, software, and mission operations. Current activities include a mission level field test to optimize interfaces between the payload and rover as well as better understand the interaction of the science and rover teams during the mission timeline. This paper will include the current status of the science instruments on the payload as well as the integrated field test occurring in fall of 2015. The concept of operations will be discussed, including the real time science and engineering decision-making process based on the critical data from the instrumentation. The path to flight will be discussed with the approach to this ambitious low cost mission.

ISRU↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

Investigations Using Laboratory Testbeds to Interpret Flight Instrument Datasets from Mars Robotic Missions

The Astromaterials Research and Exploration Science Directorate at the NASA Johnson Space Center (JSC) has laboratory instrumentation that mimic the capabilities of corresponding flight instruments to enable interpretation of datasets returned from Mars robotic missions. The lab instruments have been and continue to be applied to datasets for the Moessbauer Spectrometer (MB) on the Mars Exploration Rovers (MER), the Thermal & Evolved Gas Analyzer (TEGA) on the Mars Phoenix Scout, the CRISM instrument on the Mars Reconnaissance Orbiter Missions and will be applied to datasets for the Sample Analysis at Mars (SAM), Chemistry and Mineralogy (CheMin) and Chemistry & Camera (ChemCam) instruments onboard the Mars Science Laboratory (MSL). The laboratory instruments can analyze analog samples at costs that are substantially lower than engineering models of flight instruments, but their success to enable interpretation of flight data depends on how closely their capabilities mimic those of the flight instrument. The JSC lab MB instruments are equivalent to the MER instruments except without flight qualified components and no reference channel Co-57 source. Data from analog samples were critical for identification of Mg-Fe carbonate at Gusev crater. Fiber-optic VNIR spectrometers are used to obtain CRISM-like spectral data over the range 350-2500 nm, and data for Fephyllosilicates show irreversible behavior in the electronic transition region upon dessication. The MB and VNIR instruments can be operated within chambers where, for example, the absolute H2O concentration can be measured and controlled. Phoenix's TEGA consisted of a calorimeter coupled to a mass spectrometer (MS). The JSC laboratory testbed instrument consisted of a differential scanning calorimeter (DSC) coupled to a MS configured to operate under total pressure (12 mbar), heating rate (20 C/min), and purge gas composition (N2) analogous to the flight TEGA. TEGA detected CO2 release at both low (400-680 C) and high (725-820 C) temperature and an endothermic reaction in concert with the high temperature release. The high-temperature thermal decomposition is consistent with calcite, dolomite, or ankerite, (3-6 wt.%) or any combination of these phase based upon laboratory testbed experiments. Recent laboratory experiments suggest that the low temperature CO2 release was caused by a reaction between calcium carbonate and hydrated magnesium perchlorate; although, CO2 release by the oxidation of organic materials and Fe-/Mg-rich carbonates cannot be ruled out. MSL landed in Gale crater on August 5, 2012. Although numerous analog samples have been analyzed on the JSC laboratory testbeds, no SAM, CheMin, or ChemCam analyses have been acquired by MSL to date. The JSC SAM laboratory testbed consists of a thermal analyzer coupled with a MS configured to operate under total pressure (30 mbar), heating rate (35 C/min), and purge gas composition (He) analogous to the flight SAM. The CheMin and ChemCam laboratory testbeds were developed and built by inXitu, Inc. and Los Alamos National Laboratory, respectively, to acquire datasets relevant to the MSL CheMin and ChemCam flight instruments.

Ming, D. W.↗