Search NASA⌕ Search

SEARCH · Search NASA

Results for “exit time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

159 records · Page 9

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Raw_data_Batch_I: Argonne to Shorewood via I-55

Date of collection: May 12, 2023 Location: Interstate 55, DuPage County, IL This data set contains lidar and vision data collected along a round trip between I-55 Exit 273A and Exit 253. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![argonne shorewood image](argone-shorewood.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a new control rod drive mechanism design for the ISU AGN-201M reactor

The Aerojet General Nucleonics (AGN) model 201-Modified, known as the AGN-201M reactor, plays an essential role in the educational and research activities at Idaho State University (ISU). The ISU AGN-201M's original Control Rod Drive Mechanism (CRDM) has been in operation for more than fifty years with no large-scale redesigns. The CRDM is required to eject the fuel rods within one second during a SCRAM event (also known as a 'reactor trip') and adjust the control rods' insertion speed, and keeps the rod insertion sequence correct. The existing control rod drive mechanisms meet these criteria but experience a few concerns due to aging. Concerns include complex maintenance and costly repairs for old electromechanical components, rod position feedback errors, and the impediment of the plate during a SCRAM due to binding of the lead screws of the existing mechanism. During a binding event, the drive mechanism becomes locked, preventing the control rod's magnetic plate from moving in or out under the reactor's normal and emergency operating conditions. Although, the binding has no effect on the ability of the rod to exit the core during the SCRAM. To counteract the concerns and issues with the current CRDM, a new design has been proposed using newer components and a simplified design. The new design utilizes more advanced electric and mechanical components that are commercially available. The new CRDM system is divided into four main aspects: (1) control rod movement design (motor, lead screw, guide rods), (2) control rod ejection (springs, electromagnet), (3) control rod position and feedback (position transducer, microswitches), and (4) material selection and structural analysis. The new design aims to reduce the overall complexity and probability of failure to improve the reactor's overall reliability. With proper material selection and improved structural design, the new drives are lighter with little to no change in structural integrity. The new control rod drive mechanism eliminates binding scenarios by using a single lead screw and implementing additional guide rods. An advanced linear position sensor and microswitches replace the existing and aging synchro system for accurate rod position feedback resulting in better reactivity control. The new design meets the reactor's operational limits by having an average reactivity insertion of 0.065% Δk/k per second, which corresponds to a total control rod insertion time of 19.23 s, while the control rod's ejection time remains less than one second during a SCRAM event. The new design ensures the reactor's long-term viability for educational and research activities by increasing the reliability and safety of operation for years to come.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Raw_data_Batch_I: Lisle to Waterfall Glen

Date of collection: May 11, 2023 Location: DuPage County, IL This dataset contains lidar and vision data collected between Lisle, IL, and the Waterfall Glen parking lot. The vehicle started near Cass School District 63, headed east along IL 34. The vehicle then turned south along IL 83 until Interstate 55. Finally, the vehicle turned southwest along I 55 until Exit 273A and headed toward the Waterfall Glen parking lot. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![lisle waterfall image](lisle-waterfall.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Kinetic Monte Carlo Approach for Simulating Cascading Transmission Line Failure

In this work, cascading transmission line failures are studied through a dynamical model of the power system operating under fixed conditions. The power grid is modeled as a stochastic dynamical system where first-principles electromechanical dynamics are excited by small Gaussian disturbances in demand and generation around a specified operating point. In this context, a single line failure is interpreted in a large deviation context as a first escape event across a surface in phase space defined by line security constraints. The resulting system of stochastic differential equations admits a transverse decomposition of the drift, which leads to considerable simplification in evaluating the quasipotential (rate function) and, consequently, computation of exit rates. Tractable expressions for the rate of transmission line failure in a restricted network are derived from large deviation theory arguments and validated against numerical simulations. Extensions to realistic settings are considered, and individual line failure models are aggregated into a Markov model of cascading failure inspired by chemical kinetics. Cascades are generated by traversing a graph composed of weighted edges representing transitions to degraded network topologies. Numerical results indicate that the Markov model can produce cascades with qualitative power-law properties similar to those observed in empirical cascades.

Kinetic Monte Carlo, rare events, Cascading Failur↗

Surface Roughness Effects from Additive Manufacturing in High Efficiency Gas Turbine Combustion Systems

In the past, clean combustion systems were characterized by high system development costs due to growing complexity and escalating manufacturing costs from conventional manufacturing processes. As a result, high efficiency concepts are difficult to design and more difficult to be cost-effectively manufactured. In recent years, with the introduction of additive manufacturing (AM) technologies, the rapid prototyping and mass production processes of clean combustion systems are promising to be significantly simplified with significant reduction in terms of engine manufacturing cost and engine energy cost. Compared with conventional manufacturing built parts, the AM process enabled a simpler design to be adopted for the nozzle, reducing the number of required braze and weld joints from twenty-five to just five. The resulting nozzle was 25% lighter and five times more durable and contributed to a 15% reduction in fuel burn in comparison with the previous model produced. Applying these improvements to a fleet of 5,000 turbofan engines at 150 kN thrust would result in fuel cost savings of $ \$ $6B annually (at $ \$ $5/gallon Jet-A fuel price, 700 gallon/hour fuel consumption rate, and 2,300 operational hours per year), and reduce CO2 emissions by more than 25 million tons per year. These advances support core Department of Energy (DOE) missions in energy efficiency, improving productivity, and environmental sustainability. Maximizing the benefit of these new capabilities will require high prediction capability of high speed turbulent flow with wall modeled Large Eddy Simulation (LES). GE Aviation maintains that advanced simulation technology and supercomputing is required in order to provide the appropriate boundary conditions to realize the maximum potential of AM and Ceramic Matrix Composite to reduce cooling flow, a first order penalty on the Brayton cycle. The algorithm developed using the ANSYS/Fluent software would provide the foundation for entirely new avenues of research and development with potential multi-billion dollar impact to the US economy, and significant reduction in carbon based emissions across the aerospace and power generation industries. The formulation of this iWLES (integral wall model for LES) is generic and allows to capture the changes in flow dynamics that have a significant impact on the wall bounded flow characteristics, such as swirler effective area, bulk swirl number, local pressure distribution, exit velocity profile, and turbulence kinetic energy profile. A periodic channel flow with rough flat plate is simulated using LES (Wall-Adapting Local Eddy-viscosity) model to verify the implementation of iWLES in the Fluent User Defined Function (UDF). As the flow fields are highly sensitive due to surface roughness of the wall bounded flows in the combustion systems, there is significant potential to conduct further LES studies focusing on the turbulence boundary layer interaction. Accurately capturing near wall physics will elucidate the impact of rough surfaces on combustor flow and aero-thermal interactions.

42 ENGINEERING↗

Surface Roughness Effects from Additive Manufacturing in High Efficiency Gas Turbine Combustion Systems

In the past, clean combustion systems were characterized by high system development costs due to growing complexity and escalating manufacturing costs from conventional manufacturing processes. As a result, high efficiency concepts are difficult to design and more difficult to be cost-effectively manufactured. In recent years, with the introduction of additive manufacturing (AM) technologies, the rapid prototyping and mass production processes of clean combustion systems are promising to be significantly simplified with significant reduction in terms of engine manufacturing cost and engine energy cost. Compared with conventional manufacturing built parts, the AM process enabled a simpler design to be adopted for the nozzle, reducing the number of required braze and weld joints from twenty-five to just five. The resulting nozzle was 25% lighter and five times more durable and contributed to a 15% reduction in fuel burn in comparison with the previous model produced. Applying these improvements to a fleet of 5,000 turbofan engines at 150 kN thrust would result in fuel cost savings of $6B annually (at $5/gallon Jet-A fuel price, 700 gallon/hour fuel consumption rate, and 2,300 operational hours per year),and reduce CO2 emissions by more than 25 million tons per year. These advances support core Department of Energy (DOE)missions in energy efficiency, improving productivity, and environmental sustainability. Maximizing the benefit of these new capabilities will require high prediction capability of high speed turbulent flow with wall modeled Large Eddy Simulation (LES). GE Aviation maintains that advanced simulation technology and supercomputing is required in order to provide the appropriate boundary conditions to realize the maximum potential of AM and Ceramic Matrix Composite to reduce cooling flow, a first order penalty on the Brayton cycle. The algorithm developed using the ANSYS/Fluent software would provide the foundation for entirely new avenues of research and development with potential multi-billion dollar impact to the US economy, and significant reduction in carbon based emissions across the aerospace and power generation industries. The formulation of this iWLES (integral wall model for LES) is generic and allows to capture the changes in flow dynamics that have a significant impact on the wall bounded flow characteristics, such as swirler effective area, bulk swirl number, local pressure distribution, exit velocity profile, and turbulence kinetic energy profile. A periodic channel flow with rough flat plate is simulated using LES (Wall-Adapting Local Eddy-viscosity) model to verify the implementation of iWLES in the Fluent User Defined Function (UDF). As the flow fields are highly sensitive due to surface roughness of the wall bounded flows in the combustion systems, there is significant potential to conduct further LES studies focusing on the turbulence boundary layer interaction. Accurately capturing near wall physics will elucidate the impact of rough surfaces on combustor flow and aero-thermal interactions.

99 GENERAL AND MISCELLANEOUS↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opacity on NIF: Anchor 2 Iron (Level 2 Milestone 7118 Report)

In FY2020 we fulfilled the exit criteria of milestone 7118. We fielded iron opacity experiments at higher densities and temperatures approaching anchor 2 conditions and made good progress on overcoming the problems that we found. This report describes in detail the progress that has been made. We presented the results in a LANL seminar on August 10 and we gave two talks on our results to the National Opacity Workshop Series, one on July 9 and the other on September 14. Before discussing the anchor 2 measurements, we present an update of the NIF anchor 1 data. We did a new analysis of the anchor 1 data and compared the results to a series of calculations using the LANL ATOMIC code. Figures 1 and 2 compare the data with the best-fit to calculations. This result is significantly improved over the result published in Atoms. The differences are small for the iron quasi-continuum between 8-9.5 Å and for the Mg Heα and Lyα lines. The opacities near the centers of the iron bound-bound features also match fairly well in the 9.5-12.5 Å range. However, the opacity windows between the large iron bound-bound features are deeper in the Atomic predictions than the measurement. Furthermore, large discrepancies exist for the Mg He β, γ, and δ lines and for the short-wavelength quasicontinuum. The experiment and analysis refinements described below have set the stage for unraveling these discrepancies. Specifically, we can repeat the Anchor 1 experiments using improved backlighter, hohlraum, and spectrometers to obtain reduced backgrounds and better spectral resolution. Exploiting the AlMg calibration experiments and repeating the Anchor 1 measurements multiple times will enable formal and rigorous uncertainty determination. This well-defined path gives us confidence that high quality opacity data can be obtained on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Incentivizing Cold-Climate Efficiency in Juneau (Final Report)

This is the final technical report for the DOE EERE BTO project Incentivizing Cold-Climate Efficiency in Juneau. The project implemented a community energy campaign to deploy heat pumps and efficiency for residents of Juneau, in Southeast Alaska. The project helped Juneau make progress towards its renewable energy goal of reaching 80% renewable energy for space heating by 2045. The Incentivizing Cold-Climate Efficiency in Juneau (ICE-Juneau) project began in 2020 and concluded three years later in 2023. During that time, a group of implementation partners and a research advisory team instituted a beneficial electrification campaign to promote energy savings and carbon reduction in residences of Juneau, Alaska. The campaign, Thermalize Juneau, focused on the installation of single head ductless mini-split heat pumps along with other efficiency upgrades. Thermalize Juneau was the first campaign of its kind in Alaska. After several months of planning, registration opened to the public in early 2021, and over the course of six months 164 participants enrolled. Campaign staff provided education to homeowners on heat pumps and efficiency, and each participant received a one-on-one heat pump assessment using a custom Microsoft Excel-based calculator that estimated energy savings for their residence based on building characteristics and past utility bills. Participants could also obtain a free energy audit from one of the two local energy auditors to further inform their decision. A heat pump installer, electrician, and builder were selected via a competitive RFP process. Participants who felt ready to install a heat pump or other efficiency upgrades received a site visit and custom quote from each of these contractors free of charge, and if they still felt energy upgrades were right for them, could move forward with an individual contract. Participants received a $400 heat pump installation rebate, offered by the installer if 40 heat pump installations occurred through the campaign. Overall, the campaign facilitated 75 heat pump installations (including participants that went with another contractor or heat pump model) and 30 efficiency upgrades (including participants that went with another builder or did DIY upgrades). The campaign created 3 new jobs as the heat pump installer hired an administrative assistant and two apprentices over the course of the campaign. It also helped Juneau work toward achieving its renewable energy goal of 80% renewable energy for space heating by 2045 by upgrading houses from fuel oil to heat pumps powered by the hydropower electric grid. Researchers conducted four surveys to inform Thermalize Juneau and future energy campaigns. The first surveyed existing and prospective heat pump owners in Juneau to identify barriers the campaign could address and inform recruitment efforts. Entry and exit surveys provided information on participant demographics, goals, outcomes, and suggestions for improving future campaigns. And a final survey of community members who had not participated in Thermalize Juneau gave insight on ways future campaigns could include a greater diversity of participants so they could realize similar benefits. Researchers also used pre-campaign energy modeling to predict energy savings, which was then compared to the savings estimated through aggregation of heat pump assessments and energy audits, and later to actual energy savings of 10 participants who installed a heat pump and were able to provide complete energy use data sets. In addition to energy savings, and to assist the electric utility in future planning efforts, researchers analyzed the overall change in electric use across participants with energy data and heat pump installations. They also completed a life cycle cost analysis, showing positive net present values for those displacing a fuel oil appliance, and a more mixed case for those switching from electric baseboard. This project proved the feasibility of energy campaigns, with a goal of beneficial electrification, in cold, remote locations. The Thermalize Juneau team compiled a Guidebook to Thermalize Campaigns, available online. In addition to documenting what occurred in Alaska’s first thermalize campaign, it provides tips and resources for other communities wishing to implement a similar program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗