Search NASA⌕ Search

SEARCH · Search NASA

Results for “expandable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Expanding the modular ester fermentative pathways for combinatorial biosynthesis of esters from volatile organic acids

ABSTRACT Volatile organic acids are byproducts of fermentative metabolism, for example, anaerobic digestion of lignocellulosic biomass or organic wastes, and are often times undesired inhibiting cell growth and reducing directed formation of the desired products. Here, we devised a general framework for upgrading these volatile organic acids to high‐value esters that can be used as flavors, fragrances, solvents, and biofuels. This framework employs the acid‐to‐ester modules, consisting of an AAT (alcohol acyltransferase) plus ACT (acyl CoA transferase) submodule and an alcohol submodule, for co‐fermentation of sugars and organic acids to acyl CoAs and alcohols to form a combinatorial library of esters. By assembling these modules with the engineered Escherichia coli modular chassis cell, we developed microbial manufacturing platforms to perform the following functions: (i) rapid in vivo screening of novel AATs for their catalytic activities; (ii) expanding combinatorial biosynthesis of unique fermentative esters; and (iii) upgrading volatile organic acids to esters using single or mixed cell cultures. To demonstrate this framework, we screened for a set of five unique and divergent AATs from multiple species, and were able to determine their novel activities as well as produce a library of 12 out of the 13 expected esters from co‐fermentation of sugars and (C2‐C6) volatile organic acids. We envision the developed framework to be valuable for in vivo characterization of a repertoire of not‐well‐characterized natural AATs, expanding the combinatorial biosynthesis of fermentative esters, and upgrading volatile organic acids to high‐value esters. Biotechnol. Bioeng. 2016;113: 1764–1776. © 2016 Wiley Periodicals, Inc.

Layton, Donovan S.↗

Finite Convergence of a Subgradient Projections Method with Expanding Controls

We study finite convergence of the modified cyclic subgradient projections (MCSP) algorithm for the convex feasibility problem (CFP) in the Euclidean space. Expanding control sequences allow the indices of the sets of the CFP to re-appear and be used again by the algorithm within windows of iteration indices whose lengths are not constant but may increase without bound. Motivated by another development in finitely convergent sequential algorithms that has a significant real-world application in the field of radiation therapy treatment planning, we show that the MCSP algorithm retains its finite convergence when used with an expanding control that is repetitive and fulfills an additional condition.

97 MATHEMATICS AND COMPUTING↗

Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent until the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and physicochemical characterization of graphene oxide derived from thermally expanded graphite

Graphene oxide was obtained from expanded graphite according to the modified Hummers method. The reaction time was significantly reduced (from 24 to 8 h) by applying the expanded graphite in the oxidation process. The interlayer distance in obtained samples was equal to 0.70–0.74 nm. Structural features of the material were studied by the powder X-ray diffraction, thermogravimetric analysis, scanning electron microscopy, transmission electron microscopy, XPS spectroscopy, and NMR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Range cost-effectiveness of plug-in electric vehicle for heterogeneous consumers: An expanded total ownership cost approach

Plug-in electric vehicles (PEV) appears to have sales momentum in major personal vehicle markets but are still at the early market stage. Opportunities to accelerate PEV adoption can be discovered through comprehensive total cost of ownership (TCO) analysis. Understanding the cost-effective electric ranges of PEVs for consumers, manufacturers, and the society is critical for any discussion of PEV mass markets. This study expanded the traditional TCO approach by (1) fully considering heterogeneous consumer driving patterns, (2) quantifying the charging inconvenience and range anxiety cost of battery-electric vehicles (BEVs), and (3) monetizing both tangible and intangible PEV policies. Uncertainties were handled through Monte Carlo simulation. The results suggest that BEVs with an electric range of 250–350 km have the lowest TCO in cities with government-enacted purchase limitations, and internal combustion engine vehicles (ICEVs) have the lowest TCO in cities without purchase limitations, even when considering PEV subsidies. The lowest TCO for some consumer groups is obtained by BEVs with an electric range of 400–450 km, especially in northern China, where the weather is colder. The cost-effective all-electric range for BEVs in each city in 2025 will decrease due to improved battery performance in cold environments and an expanded charging infrastructure. Finally, based on TCO, plug-in hybrid electric vehicles (PHEVs) are currently more suitable for drivers with a high average daily mileage or a large mileage variance. However, by 2025, BEVs with a long driving range may become a more cost-effective choice for these drivers.

33 ADVANCED PROPULSION SYSTEMS↗

IL-15 inhibits pre-B cell proliferation by selectively expanding Mac-1{sup +}B220{sup +} NK cells

Natural killer (NK) cells are the cells critical for inhibition of repopulation of allogenic bone marrow cells. However, it is not well known if NK cells affect autologous lymphopoiesis. Here, we observed that NK cells could inhibit pre-B cell proliferation in vitro driven by interleukin (IL)-7 in a manner dependent on IL-15. Interestingly, the great majority of expanding NK cells were Mac-1{sup +}B220{sup +}, a recently identified potent interferon (IFN)-{gamma} producer. Indeed, IFN-{gamma} was produced in those cultures, and pre-B cells lacking IFN-{gamma} receptors, but not those lacking type I IFN receptors, were resistant to such an inhibition. Furthermore, even NK cells from mice lacking {beta}2-microglobulin, which were known to be functionally dampened, inhibited pre-B cell proliferation as well. Thus, activated NK cells, which were expanded selectively by IL-15, could potentially regulate B lymphopoiesis through IFN-{gamma} beyond the selection imposed upon self-recognition.

60 APPLIED LIFE SCIENCES↗

Positioning the expanded akirin gene family of Atlantic salmon within the transcriptional networks of myogenesis

Research highlights: {yields} The expanded akirin gene family of Atlantic salmon was characterised. {yields} akirin paralogues are regulated between mono- and multi-nucleated muscle cells. {yields} akirin paralogues positioned within known genetic networks controlling myogenesis. {yields} Co-expression of akirin paralogues is evident across cell types/during myogenesis. {yields} Selection has likely maintained common regulatory elements among akirin paralogues. -- Abstract: Vertebrate akirin genes usually form a family with one-to-three members that regulate gene expression during the innate immune response, carcinogenesis and myogenesis. We recently established that an expanded family of eight akirin genes is conserved across salmonid fish. Here, we measured mRNA levels of the akirin family of Atlantic salmon (Salmo salar L.) during the differentiation of primary myoblasts cultured from fast-skeletal muscle. Using hierarchical clustering and correlation, the data was positioned into a network of expression profiles including twenty further genes that regulate myogenesis. akirin1(2b) was not significantly regulated during the maturation of the cell culture. akirin2(1a) and 2(1b), along with IGF-II and several igfbps, were most highly expressed in mononuclear cells, then significantly and constitutively downregulated as differentiation proceeded and myotubes formed/matured. Conversely, akirin1(1a), 1(1b), 1(2a), 2(2a) and 2(2b) were expressed at lowest levels when mononuclear cells dominated the culture and highest levels when confluent layers of myotubes were evident. However, akirin1(2a) and 2(2a) were first upregulated earlier than akirin1(1a), 1(1b) and 2(2b), when rates of myoblast proliferation were highest. Interestingly, akirin1(1b), 1(2a), 2(2a) and 2(2b) formed part of a module of co-expressed genes involved in muscle differentiation, including myod1a, myog, mef2a, 14-3-3{beta} and 14-3-3{gamma}. All akirin paralogues were expressed ubiquitously across ten tissues, although mRNA levels were regulated between cell-types and family members. Gene expression patterns were often highly correlated between akirin paralogues, suggesting that natural selection has maintained an intricate network of co-regulation among family members. We concluded that the Atlantic salmon akirin family performs a multifaceted role during myogenesis and has physiological functions spanning many cell-types.

60 APPLIED LIFE SCIENCES↗

In vitro expanded bone marrow-derived murine (C57Bl/KaLwRij) mesenchymal stem cells can acquire CD34 expression and induce sarcoma formation in vivo

Highlights: Black-Right-Pointing-Pointer Murine MSCs can undergo spontaneously malignant transformation and form sarcoma. Black-Right-Pointing-Pointer Acquisition of CD34 is a transformation type for MSCs into sarcoma. Black-Right-Pointing-Pointer Notch/Hh/Wnt pathways are related to the malignant phenotype of transformed MSCs. -- Abstract: Mesenchymal stem cells (MSCs) have currently generated numerous interests in pre-clinical and clinical applications due to their multiple lineages differentiation potential and immunomodulary effects. However, accumulating evidence indicates that MSCs, especially murine MSCs (mMSCs), can undergo spontaneous transformation after long-term in vitro culturing, which might reduce the therapeutic application possibilities of these stem cells. In the present study, we observed that in vitro expanded bone marrow (BM) derived mMSCs from the C57Bl/KaLwRij mouse strain can lose their specific stem cells markers (CD90 and CD105) and acquire CD34 expression, accompanied with an altered morphology and an impaired tri-lineages differentiation capacity. Compared to normal mMSCs, these transformed mMSCs exhibited an increased proliferation rate, an enhanced colony formation and migration ability as well as a higher sensitivity to anti-tumor drugs. Transformed mMSCs were highly tumorigenic in vivo, resulting in aggressive sarcoma formation when transplanted in non-immunocompromised mice. Furthermore, we found that Notch signaling downstream genes (hey1, hey2 and heyL) were significantly upregulated in transformed mMSCs, while Hedgehog signaling downstream genes Gli1 and Ptch1 and the Wnt signaling downstream gene beta-catenin were all decreased. Taken together, we observed that murine in vitro expanded BM-MSCs can transform into CD34 expressing cells that induce sarcoma formation in vivo. We assume that dysregulation of the Notch(+)/Hh(-)/Wnt(-) signaling pathway is associated with the malignant phenotype of the transformed mMSCs.

60 APPLIED LIFE SCIENCES↗

Building an expanded bio-based economy through synthetic biology

The field of synthetic biology is essential to the continued development of a bio-based economy, creating mechanisms to supply carbon needed in the economy by both converting existing end-of-life wastes as well as by creating novel, purpose-grown and sustainable feedstocks. Here, we first discuss the near- and long-term resources available for use as feedstocks for bioconversion as well as the output molecules needed for building the foundation of an expanded bio-based economy. We then outline the organisms and phenotypic traits that are needed for the performance-advantaged chassis organisms of the future. Furthermore, we detail the advances, challenges, and opportunities in both microbial and plant synthetic biology relevant to expanding the bio-based economy. Finally, we explore technologies that have and will further enable advances in synthetic biology and the greater bio-based economy.

09 BIOMASS FUELS↗

Synthesis and characterization of (H{sub 2}dab){sub 2}Cu{sub 8}Ge{sub 4}S{sub 14}{center_dot}2H{sub 2}O: An expanded framework based on icosahedral Cu{sub 8}S{sub 12} cluster

A new three-dimensional framework copper-thiogermanate, (H{sub 2}dab){sub 2}Cu{sub 8}Ge{sub 4}S{sub 14}{center_dot}2H{sub 2}O (1), was prepared under solvothermal condition and characterized by elemental analysis, single-crystal and powder X-ray diffraction, thermogravimetric analysis and UV-vis diffuse reflectance spectroscopy. Compound 1 crystallizes in the monoclinic space group P2(1)/c, a=11.444(4) A, b=12.984(4) A, c=12.455(6) A, {beta}=91.527(1) Degree-Sign , V=1850.2(3) A{sup 3}, Z=2. It contains a new three-dimensional Cu-Ge-S framework constructed from icosahedral [Cu{sub 8}S{sub 12}]{sup 16-} clusters linked by [GeS{sub 4}]{sup 4-} and dimeric [Ge{sub 2}S{sub 6}]{sup 4-} units, with diprotonated 1,4-dab (1,4-diaminobutane) and H{sub 2}O molecules located in the intersecting channels. UV-vis reflectance spectroscopy reveals the band gap of compound 1 is 2.5 eV. - Graphical abstract: Compound 1 contains a 3D expanded framework constructed from icosahedral Cu{sub 8}S{sub 12} clusters linked by GeS{sub 4} and dimeric Ge{sub 2}S{sub 6} units, with diprotonated 1,4-dab and H{sub 2}O molecules located in the channels. Highlights: Black-Right-Pointing-Pointer A new 3-D framework copper-thiogermanate was prepared under solvothermal condition. Black-Right-Pointing-Pointer The framework is built up from icosahedral Cu{sub 8}S{sub 12} clusters linked by GeS{sub 4} and dimeric Ge{sub 2}S{sub 6} units. Black-Right-Pointing-Pointer The result provides a new strategy to expand octahedral SBUs-based framework. Black-Right-Pointing-Pointer Compound 1 is a semiconductor with the band gap of 2.5 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗