At least 163 records · Page 9

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radon kinetics in a natural indoor radon chamber

An unusual 180 m 3 storage room in the basement of a two-story laboratory building is unventilated, and separated from occupiable rooms by double steel doors. The space completely borders on soil through the concrete floor and two of its concrete walls. The room also contains a separate inner chamber with 1 m thick concrete walls designed to damp vibrations in the room above it. The space boasts a relatively high radon level, 1083 Bq m –3 , which varies with local outdoor environmental conditions. Measurements were made of radon concentrations at various locations and heights within the facility. More than a year of continuous radon concentration data corresponding to a single location are also available, along with measurements of indoor and outdoor pressure, temperature, and humidity. Data were also collected with as many as five fans placed in different locations and cycled on for variable time periods. First order linear kinetic models were created to explain the observed approaches to steady state due to changing conditions and wash-out resulting from intentional ventilation. Results demonstrate a good fit between changes in the radon concentration level and the developed compartmental models. Furthermore, no significant differences were observed between radon concentration at different locations or heights in the chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Northward propagation of the Gulf of Elat-Aqaba constrained by cosmogenic burial ages and magnetostratigraphy of onshore sediments

The Gulf of Elat-Aqaba (GEA), located in the southern part of the Dead Sea Transform (DST), is one of the most active segments of the Dead Sea fault system. Yet, some fundamental details concerning its evolution in space and time are still not fully understood. To better constrain the tectonic history of this region, we study a succession of alluvial, lacustrine, and fluvial deposits in the north-western edge of the GEA, which belong to the Quaternary Eilot and Garof Fms. The Eilot Fm. represents low-energy shallow freshwater bodies and sabkhas, which predate the development of the deep part of the basin. Later, in response to the subsidence of the basin, the Garof Fm. was deposited in alluvial fans that built up following the increase in the depositional energy. Cosmogenic burial ages combined with magnetostratigraphy show that these Fms. were deposited as early as 3.03 Ma and as late as 1.65 Ma, depending on the applied age model. Considering the present depth of the northern GEA, this age indicates a maximum subsidence rate of the head of the GEA of ~1.98mm/yr. We suggest that faults along the onshore margin of the deep basin were active during the deposition of the Garof Fm. and subsequently became inactive, while the faulting activity migrated toward the center of the basin. In conclusion, closed Holocene basins north of the present seashore, such as the Elat and Evrona playas, which may represent a modern analogue to the Plio-Pleistocene morphology, raise the possibility that the GEA head is still propagating northward.

58 GEOSCIENCES↗

Model-Based Energy and Cost Analysis of Direct Air Capture Using ePTFE-Based Laminate-Structured Gas–Solid Contactors

Carbon dioxide removal (CDR) technologies will play a significant role in limiting global warming if implemented on a large scale. Direct air capture (DAC) is a scalable approach for removing atmospheric carbon, yet the true scope of its scalability remains unclear due to the early stage of technology development and high first plant costs. This study provides groundwork for understanding the technoeconomic trade-offs in developing DAC systems using laminate-structured gas–solid contactors, encompassing the analysis of both contactor and process design spaces. The robust mass transfer and process models outlined in this study provide tools for evaluating DAC processes and designing DAC plants based on cost and energy analysis. First, the key contactor geometrical parameters are identified to understand the CO 2 productivity–energy demand trade-offs, where geometries yielding higher mass transfer rates can achieve higher CO 2 productivities at the expense of energy consumption by fans and steam use. Next, a detailed process parametric study is conducted for DAC systems coupled with steam-assisted temperature-vacuum swing adsorption (S-TVSA) to visualize the trade-offs in the multidimensional design space. The main cost driver dramatically changes over different process conditions, but the operating cost prevailed on the Pareto front, with potential to operate as low as 150 $/tonne-CO 2 (within the cost range of 148–504 $/tonne-CO 2 in this study where the DAC system is coupled with industrial facilities for steam production).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Block Tectonics across Western Tibet and Multi-Millennial Recurrence of Great Earthquakes on the Karakax Fault

We report that fault slip rates are critical to quantify continental deformation. Those along the Karakax fault (northwestern Altyn Tagh Fault: ATF) have been debated, even though it is one of Tibet's most outstanding active faults. At Taersa, using LiDAR measurements of terrace and fan riser offsets (~6 to ~500 m) and 10 Be/ 26 Al dating of alluvial surfaces (<210 ka), we obtain a late Quaternary slip rate of ~2.5 ± 0.5 mm/yr. This doubles the ~2.6 ± 0.5 mm/yr rate time span found to the east and west. We interpret the ~150 km-long, free-faced rupture along the fault to be that of the M ~ 7.6 event felt in Hotan in 1882. Characteristic slip (~6 m) during four large earthquakes since ~10 ka implies a ~2500 ± 500 years return time. A ~3 mm/yr rate is consistent with the ~80 km offset of the Karakax river since uplift of the West Kunlun range and sediment deposition in the Tarim foreland accelerated, ~24 Ma ago. The faster slip rate (~10.5 mm/yr) on the central ATF matches the sum of those along the reactivated West Tibetan terrane boundaries (Karakax and Longmu-Gozha Co faults) at the Uzatagh triple junction (~36°N, 83°E). The abrupt termination and altitude drop of the Karakorum range where the Longmu Co and Karakorum faults meet (Angmong junction), also reflect triple junction kinematics. Such localized changes account for the rise of the Karakorum and West Kunlun ranges and support lithospheric block tectonics rather than diffusely distributed deformation.

58 GEOSCIENCES↗

Modeling Sequences of Earthquakes and Aseismic Slip (SEAS) in Elasto-Plastic Fault Zones With a Hybrid Finite Element Spectral Boundary Integral Scheme

We present a coupled finite element spectral boundary integral framework for modeling sequences of earthquakes and aseismic slip on a 2-D planar rate-and-state fault with off-fault visco-plastic response in the plane strain approximation. The model resolves both slow aseismic deformation and inertia effects during rapid slip. As an application, we perform two sets of simulations with different choices of cohesion to explore the co-evolution of fault slip, bulk plasticity and local stress fields. The first set implements a relatively large value of the cohesion parameter, which results in limiting inelastic strain accumulation to dynamic rupture phases. The second set implements a smaller cohesion, allowing for plastic strain to accumulate in both seismic and aseismic phases. For the first model, our results indicate that the extent and distribution of plastic strain depend on the angle of maximum compressive principal stress. At larger angles, inelastic strain accumulates on the extensional side of a dynamically propagating rupture. At smaller angles, the extent of plasticity is limited to the compressional side of the domain. At smaller cohesion values, off-fault plasticity may occur during aseismic slip, which alters the nucleation characteristics and earthquake sequence pattern. Furthermore, our results at lower cohesion values indicate that plastic strain accumulation may occur in both the extensional and compressional sides of the off-fault bulk even at higher angles of maximum compression. In conclusion, this produces damage patterns that deviate from the traditional off-fault fan-like distribution observed in dynamic rupture simulations and emphasizes the significance of long-term deformation in interpreting observations.

58 GEOSCIENCES↗

Phonon-exciton Interactions in WSe 2 under a quantizing magnetic field

Strong many-body interaction in two-dimensional transitional metal dichalcogenides provides a unique platform to study the interplay between different quasiparticles, such as prominent phonon replica emission and modified valley-selection rules. A large out-of-plane magnetic field is expected to modify the exciton-phonon interactions by quantizing excitons into discrete Landau levels, which is largely unexplored. Here, we observe the Landau levels originating from phonon-exciton complexes and directly probe exciton-phonon interaction under a quantizing magnetic field. Phonon-exciton interaction lifts the inter-Landau-level transition selection rules for dark trions, manifested by a distinctively different Landau fan pattern compared to bright trions. This allows us to experimentally extract the effective mass of both holes and electrons. The onset of Landau quantization coincides with a significant increase of the valley-Zeeman shift, suggesting strong many-body effects on the phonon-exciton interaction. Our work demonstrates monolayer WSe 2 as an intriguing playground to study phonon-exciton interactions and their interplay with charge, spin, and valley.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topological behavior and Zeeman splitting in trigonal PtBi2-x single crystals

Abstract Transition-metal dipnictide PtBi 2 exhibits rich structural and physical properties with topological semimetallic behavior and extremely large magnetoresistance (XMR) at low temperatures. We have investigated the electrical and magnetic properties of trigonal-phase PtBi 2 -x single crystals with x ~ 0.4. Profound de Haas–van Alphen (dHvA) and Shubnikov-de Haas (SdH) oscillations are observed. Through fast Fourier transformation (FFT) analyses, four oscillation frequencies are extracted, which result from α, β, γ, and δ bands. By constructing the Landau fan diagram for each band, the Berry phase is extracted demonstrating the non-trivial nature of the α, β, and δ bands. Despite Bi deficiency, we observe the Zeeman splitting in dHvA and SdH oscillations under moderate magnetic field and the moderate Landé g factor (4.97–6.48) for the α band. Quantitative analysis of the non-monotonic field dependence including the sign change of the Hall resistivity suggests that electrons and holes in our system are not perfectly compensated thus not responsible for the XMR effect.

36 MATERIALS SCIENCE↗

A measured energy use, solar production, and building air leakage dataset for a zero energy commercial building

This paper provides an open dataset of measured energy use, solar energy production, and building air leakage data from a 328 m 2 (3,531 ft 2 ) all-electric, zero energy commercial building in Virginia, USA. Over two years of energy use data were collected at 1-hour intervals using circuit-level energy monitors. Over six years of solar energy production data were measured at 1-hour resolution by 56 microinverters (presented as daily and monthly data in this dataset). The building air leakage data was measured post-construction per ASTM-E779 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization and the United States Army Corps (USACE) Building Enclosure Testing procedure; both pressurization and depressurization results are provided. The architectural and engineering (AE) documents are provided to aid researchers and practitioners in reliable modeling of building performance. The paper describes the data collection methods, cleaning, and convergence with weather data. This dataset can be employed to predict, benchmark, and calibrate operational outcomes in zero energy commercial buildings.

14 SOLAR ENERGY↗

A Global Building Occupant Behavior Database

This paper introduces a database of 34 field-measured building occupant behavior datasets collected from 15 countries and 39 institutions across 10 climatic zones covering various building types in both commercial and residential sectors. This is a comprehensive global database about building occupant behavior. The database includes occupancy patterns (i.e., presence and people count) and occupant behaviors (i.e., interactions with devices, equipment, and technical systems in buildings). Brick schema models were developed to represent sensor and room metadata information. The database is publicly available, and a website was created for the public to access, query, and download specific datasets or the whole database interactively. The database can help to advance the knowledge and understanding of realistic occupancy patterns and human-building interactions with building systems (e.g., light switching, set-point changes on thermostats, fans on/off, etc.) and envelopes (e.g., window opening/closing). With these more realistic inputs of occupants’ schedules and their interactions with buildings and systems, building designers, energy modelers, and consultants can improve the accuracy of building energy simulation and building load forecasting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗