Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Graph Identification of Proteins in Tomograms (GRIP-Tomo) 2.0: Topologically aware classification for proteins

Cryo-electron tomography (cryo-ET) enables structural characterization of biomolecules under near-native conditions. Existing approaches for interpreting the resulting three-dimensional volumes are computationally expensive and have difficulty interpreting density associated with small proteins/complexes. To explore alternate approaches for identifying proteins in cryo-ET data we pursued a Graph Network and topologically invariant approach. Here, we report on a fast algorithm that classifies particles by searching for nuances of evolutionarily conversed motifs and the geometrical characteristics of protein structure. GRIP-Tomo 2.0 is a machine-learning pipeline that extracts interpretable topological features of protein structures within noisy experimental backgrounds. Compared to version 1.0, the new pipeline includes three upgrades that significantly improve performance including synthetic tomogram generation simulating realistic noise, graph-based persistent feature extraction as protein fingerprints, and high-performance computing acceleration. GRIP-Tomo 2.0 achieves over 90% accuracy in classifying between proteins and noise using both real and synthetic datasets which represents a foundational step toward advancing cryo-ET workflows and empowering automated visual proteomics.

Li, Chengxuan↗

A low-latency graph computer to identify metastable particles at the Large Hadron Collider for real-time analysis of potential dark matter signatures

Abstract Image recognition is a pervasive task in many information-processing environments. We present a solution to a difficult pattern recognition problem that lies at the heart of experimental particle physics. Future experiments with very high-intensity beams will produce a spray of thousands of particles in each beam-target or beam-beam collision. Recognizing the trajectories of these particles as they traverse layers of electronic sensors is a massive image recognition task that has never been accomplished in real time. We present a real-time processing solution that is implemented in a commercial field-programmable gate array using high-level synthesis. It is an unsupervised learning algorithm that uses techniques of graph computing. A prime application is the low-latency analysis of dark-matter signatures involving metastable charged particles that manifest as disappearing tracks.

47 OTHER INSTRUMENTATION↗

Quasi-monoenergetic ion acceleration and neutron generation from laser-driven transverse collisionless shocks

Experiments using the OMEGA EP laser system were performed to study collisionless shock acceleration of ions driven by the interaction of a relativistically intense laser pulse with underdense plasma. The energy spectrum of accelerated ions in the direction transverse to laser propagation is measured to have several narrow-band peaks which are quasi-monoenergetic with a typical energy bandwidth of 3%. In deuterium plasmas, these ions generate a significant number of fast fusion neutrons. Particle-in-cell simulations confirm that these ions were accelerated by the interaction of transverse shocks and that the appearance of quasi-monoenergetic spectral features depends on the growth of an ion-electron two-stream instability during the interaction.

Kordell, P. (ORCID:0000000321456317)↗

Predicting the rotation profile in ITER

Determining the toroidal rotation for future tokamaks like ITER is a challenging and important problem. By combining empirical scalings for the intrinsic rotation at the top of the pedestal with the expected neutral beam torque and modeling of momentum transport, the toroidal rotation profile for ITER is predicted with TGYRO using TGLF (SAT0 and SAT1). On axis rotation exceeds 20 krad s –1 and the E x B shear is significant enough to reduce turbulent transport and significantly increase confinement and fusion power when comparing to cases that ignore the effect of rotation. Here, the prediction of the rotation at the top of the pedestal is made with increased confidence due to experiments and modeling in DIII-D that have determined the importance of fast-ion and neutral particle transport effects on intrinsic rotation at this location. In particular, the effect of neutral particles on momentum transport in the pedestal region is found to be insignificant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes↗

Energetic particle physics: Chapter 7 of the special issue: on the path to tokamak burning plasma operation

We review the physics of energetic particles (EPs) in magnetically confined burning fusion plasmas with focus on advances since the last update of the ITER Physics Basis (Fasoli et al 2007 Nucl. Fusion 47 S264). Topics include basic EP physics, EP generation, diagnostics of EPs and instabilities, the interaction of EPs and thermal plasma instabilities, EP-driven instabilities, energetic particle modes (EPMs), and turbulence, linear and nonlinear stability and simulation of EP-driven instabilities and EPMs, 3D effects, scenario optimization strategies based on EP phase-space control, EPs in reduced field scenarios in ITER before DT, and the physics of runaway electrons. We describe the simulation and modeling of EPs in fusion plasmas, including instability drive and damping as well as EP transport, with a range of approaches from first-principles to reduced models, including gyrokinetic simulations, kinetic-MHD models, gyrofluid models, reduced models, and semi-analytical approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Calibrating Bayesian generative machine learning for Bayesiamplification

Recently, combinations of generative and Bayesian deep learning have been introduced in particle physics for both fast detector simulation and inference tasks. These neural networks aim to quantify the uncertainty on the generated distribution originating from limited training statistics. The interpretation of a distribution-wide uncertainty however remains ill-defined. We show a clear scheme for quantifying the calibration of Bayesian generative machine learning models. For a Continuous Normalizing Flow applied to a low-dimensional toy example, we evaluate the calibration of Bayesian uncertainties from either a mean-field Gaussian weight posterior, or Monte Carlo sampling network weights, to gauge their behaviour on unsteady distribution edges. Well calibrated uncertainties can then be used to roughly estimate the number of uncorrelated truth samples that are equivalent to the generated sample and clearly indicate data amplification for smooth features of the distribution.

97 MATHEMATICS AND COMPUTING↗

Effect of an electric field on liquid helium scintillation produced by fast electrons

The dependence on applied electric field (0–40 kV/cm) of the scintillation light produced by fast electrons and α particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations and has a dependence on the energy of the primary ionization electron. Here, we discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of BISON Milestones: NEAMS FY2020 Report

This summary report contains an overview of work performed under the work package entitled "FY2020 NEAMS Advanced Fuels Performance'', which is focused on the development and support of the fuel performance code BISON. The second chapter lists FY20 milestones titles, completion schedule, and milestone level. Subsequent chapters summarize and demonstrate completion of the milestones. The last chapter outlines FY21 proposed future work. In FY20, the NEAMS program emphasized development of BISON for its application to advanced reactors. While there are a variety of advanced fuel concepts, based on interaction with industry and the Nuclear Regulatory Commission, the fuel types we chose to develop were metallic fast reactor, UN/UC and particle fuels. The last chapter of this report documents proposed work for FY21. We plan to continue work on metallic and particle fuel in terms of developing/calibrating models and to begin rigorous validation/assessment for both fuel types. Due to the merger of the NEAMS and CASL programs, FY21 will see a return to light water reactor model development and simulation; this time focused on advanced technology fuels. Additionally, we seek to improve BISON, fundamentally. As such, we plan improvements to BISON and MOOSE in terms of algorithmic robustness, performance, ease-of-use, and quality assurance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-3/4 TRISO Fuel Compact Ceramography

The combined third and fourth irradiation in the Advanced Gas Reactor (AGR) program (AGR-3/4) contained tristructural isotropic (TRISO)-coated particle fuel and designed-to-fail (DTF) fuel particles. The DTF particles were only coated with highly anisotropic pyrocarbon (PyC) so they would purposely fail during the AGR-3/4 irradiation and provide a source of fission products for measurement. To observe the post-irradiation morphology of these DTF particles and the TRISO-coated particles, three AGR-3/4 compacts were mounted in epoxy, sectioned above their centerlines, and ground/polished. Three rounds of grinding/polishing and optical microscopy were performed so that the particles could be observed at multiple planes. Each compact contained approximately 1,872 TRISO particles and exactly 20 DTF particles. The three AGR-3/4 compacts examined covered a wide temperature range and featured both the hottest average irradiation temperature (1375°C) and the coldest/lowest burnup (872°C and 5.5% fissions per initial metal atom) of any compacts to undergo post-irradiation examination (PIE) in the AGR program to date. A total of 29 DTF particles were located and observed via microscopy across the three compacts. All the DTF particles observed via microscopy had completely failed PyC coatings. Some different DTF kernel and PyC morphologies were observed that have been attributed to the differences in irradiation temperature and/or burnup. At low and medium irradiation temperatures (roughly 850 to 1050°C), it appears irradiation-induced dimensional changes in the DTF PyC caused it to fracture and fold in on itself, and the kernel deformed to accommodate this PyC deformation. The extent of DTF kernel deformation to accommodate DTF PyC buckling tended to be greater for the medium-temperature fuel compared to the cold fuel. In the high-irradiation-temperature compact (1375°C), the DTF PyC layer appears to have completely reacted chemically with the kernel material. The only material surrounding the DTF particles in this hot compact resembles the compact matrix material. Observations of the TRISO-coated driver fuel particles and fuel compact graphitic matrix were also made. The TRISO particle kernels in the medium-temperature compact (1047°C), and many in the high-temperature compact (1375°C), showed morphologies consistent with what was seen in AGR-1 and AGR-2. In other TRISO particles from the high-temperature compact, a spatial gradient in the kernel appearance was evident. Here the cool side of the kernel (away from the center of the compact) had a much darker appearance (like that of the buffer and pyrocarbon). This is the first observation of this kind of kernel spatial gradient in AGR fuel. It is believed that the high irradiation temperature of that compact (an average of 1375°C) activates or accelerates an unidentified chemical reaction, and the temperature gradient within the fuel causes a sharp spatial gradient. The low-temperature/low-burnup compact also showed unique kernel morphologies where the TRISO-coated particles had clearly distinguishable oxide and carbide phases at the center of the kernel, an oxide rind surrounding this, and remnants of a carbide skin surrounding the oxide rind. These are features observed in the as-fabricated fuel that are no longer present in higher burnup fuel. Occasional gaps between the outer pyrolytic carbon (OPyC) and graphitic matrix material were observed in all compacts. Gaps were most often found in the small, matrix-filled spaces between adjacent particles. Finally, buffer morphologies in AGR-3/4 TRISO particles were like those observed in AGR-1 and AGR-2, and the buffer fracture frequencies in AGR-3/4 and AGR-2 TRISO particles were plotted versus fast neutron fluence and irradiation temperature. In AGR-3/4 the buffer fracture rate was highest (23%) for an irradiation temperature of 1047°C and a fast fluence of 5.18E25 n/m 2 . Increasing the irradiation temperature to 1375°C reduced the buffer fracture rate to 14%. Reducing the irradiation temperature to 872°C and the fast fluence by a factor of 3 reduced the buffer fracture rate to 7%. The temperature and fluence dependencies observed for AGR-3/4 buffer fracture were consistent with those observed in AGR-2. Lower fluences and/or higher temperatures significantly reduced the buffer fracture frequencies. Lower buffer fracture frequencies were also observed at lower temperatures as long as the fluence was also significantly reduced. This is believed to be due to lower fluence resulting in less irradiation-induced dimensional change (shrinkage) of the buffer, and a higher temperature promoting enhanced creep relaxation of stresses within the buffer, leading to less buffer fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerating discoveries at DIII-D with the Integrated Research Infrastructure

DIII-D research is being accelerated by leveraging high performance computing (HPC) and data resources available through the National Energy Research Scientific Computing Center (NERSC) Superfacility initiative. As part of this initiative, a high-resolution, fully automated, whole discharge kinetic equilibrium reconstruction workflow was developed that runs at the NERSC for most DIII-D shots in under 20 min. This has eliminated a long-standing research barrier and opened the door to more sophisticated analyses, including plasma transport and stability. These capabilities would benefit from being automated and executed within the larger Department of Energy Advanced Scientific Computing Research program’s Integrated Research Infrastructure (IRI) framework. The goal of IRI is to empower researchers to meld DOE’s world-class research tools, infrastructure, and user facilities seamlessly and securely in novel ways to radically accelerate discovery and innovation. For transport, we are looking at producing flux matched profiles and also using particle tracing to predict fast ion heat deposition from neutral beam injection before a shot takes place. Our starting point for evaluating plasma stability focuses on the pedestal limits that must be navigated to achieve better confinement. This information is meant to help operators run more effective experiments, so it needs to be available rapidly inside the DIII-D control room. So far this has been achieved by ensuring the data is available with existing tools, but as more novel results are produced new visualization tools must be developed. In addition, all of the high-quality data we have generated has been collected into databases that can unlock even deeper insights. This has already been leveraged for model and code validation studies as well as for developing AI/ML surrogates. The workflows developed for this project are intended to serve as prototypes that can be replicated on other experiments and can be run to provide timely and essential information for ITER, as well as next stage fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Industrial scale mesofluidic particle separation

Here we explore the potential of a mesofluidic separator that fits within industrial piping and is designed to remove large aspherical particles out of an abrasive slurry at fast flow rates. Mesofluidic separators have recently demonstrated separation of spherical particles at flow rates of ~1 gallon/min (gpm) (6.3.10 -5 m 3 /s). Yet, the performance of these separators at flow rates achievable within industrial piping have not been explored. Here we evaluate the permeate flowrate fraction, large particle mass fraction, and pressure drop from approximately 35-100 gpm (2.2.10-3-6.3.10-3 m 3 /s) in a three inch tube using an abrasive and modestly non-spherical slurry. Faster flow rates may be achieved with larger pumps and larger diameters. We find the permeate fraction and pressure drop both increase with flow rate, though the pressure drop remains modest. Only two feet of inserts removed 97.6±2.1% of large particles for conditions tested. Separation was demonstrated in both vertical and horizontal orientations with the horizontal orientation benefiting marginally from gravitational settling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation study of fast ion losses associated with the rotating n = 1 resonant magnetic perturbations in KSTAR

In this work we describe a simulation framework for testing the fast ion loss mechanism associated with the experimentally observed beam ion losses when an externally applied toroidally rotating perturbed magnetic field is used to control edge localized modes in the KSTAR tokamak. The simulations reproduce the key qualitative features of neutral beam injection (NBI) ion detection by a fast ion loss detector. The NBI ion losses in the simulation mainly occur for passing particles due to orbit stochastization, which is caused by orbit resonance with the 3D field perturbations. The relative toroidal angle of NBI ion deposition to the orbit island determines the radial path of the particles between confinement or loss. The fast ion loss quantity depends on the toroidal angle rotation of the 3D field with respect to the beam deposition position. The averaged transport of toroidal canonical angular momentum reveals that linear and nonlinear resonance of the NBI ions within the 3D field are the main factors determining fast ion transport and loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗