Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Basement Fault Activation before Larger Earthquakes in Oklahoma and Kansas

Oklahoma and Kansas experienced unprecedented seismic activity over the past decade due to earthquakes associated with unconventional hydrocarbon development. The modest natural seismicity and incomplete knowledge of the fault network in the region made it difficult to anticipate the locations of earthquakes with larger magnitudes (M w ≥ 4). Here, we show that monitoring of microearthquakes at regional scale using a pretrained neural phase picker and an earthquake relocation algorithm can illuminate unknown fault structures, and deliver information that can be synthesized for earthquake forecasting. We found that 80% of the larger earthquakes that occurred in the past decade could have been anticipated based on the spatial extent of the seismicity clusters that were formed before these earthquakes occurred. We also found that once a seismicity cluster with a length scale enough to host a larger earthquake was formed, there was a ~5% chance that it would host one or more larger earthquakes within a year. This probability is nearly an order of magnitude higher than one based on Gutenberg–Richter statistics and preceding seismicity. Applying our approach in practice can provide critical information on seismic hazards for risk management and regulatory decision making.

58 GEOSCIENCES↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated End-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows

This report details recent progress for the ASCR funded project “Integrated End-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows”. We refer to the project as IPPD/2, reflecting the 2017 renewal under expanded scope and partners In IPPD/2, we increased our research scope to include data motion. We are focusing on three major aspects: a) observe how data is generated, distributed, and used; b) analyze how data is (repeatedly) consumed with a focus both on repeated patterns and anomalies; and c) explore how to optimize data motion. This new work on data motion will augment and complement IPPD/2’s research that focused on the computational aspects of tasks. We leverage and extend our existing tools and demonstrate our work on the Belle II workflow suite as well as on workflows from NSLS-II. The highlights of our work are as follows: Provenance for Workflows: Provenance is used to provide information enabling quality control, re-run computational workflows, and reproduce results. IPPD/2 has been building a scalable provenance management system that enables the capture of provenance from the high-level workflow through all relevant system levels in one integrated environment. Leveraging this work, our recent efforts have included using provenance as an enabling technique. Workload characterization: Leveraging provenance and analysis, we characterize data movement within network, storage, and memory over a variety of workloads. This characterization enables an understanding by performance analysts and application developers of the range of behaviors that could be expected. Performance Prediction for Workflows: The goal of modeling distributed workflows is to understand performance bottlenecks and enable more intelligent task scheduling to optimize selected metrics of interest (e.g., task throughput or output data rate). IPPD/2 has utilized both analytical and AI/ML modeling methodologies for performance modeling. Advanced Scheduling and Fault Modeling for Workflows: Scheduling of large-scale scientific workflows on geographically distributed resources is a challenging problem. To improve workflow throughput, we combined novel scheduling algorithms with task predictions from performance modeling and fault modeling. Dynamically Alleviating Bottlenecks in Workflows: Exploiting our provenance, analysis, and modeling efforts, we have explored and developed several techniques for dynamically detecting and alleviating bottlenecks in data movement. In particular, we have spent considerable effort demonstrating our techniques on production-like workflow configurations.

97 MATHEMATICS AND COMPUTING↗

RAPIDS: Reconciling Availability, Accuracy, and Performance in Managing Geo-Distributed Scientific Data

In modern science, big data plays an increasingly important role. Many scientific applications, such as running simulations on supercomputers or conducting experiments on advanced instruments, produce huge amount of data at unprecedented speed. Analyzing and understanding such big data is the key for scientists to make scientific breakthroughs. However, data might become unavailable for scientists to access when outages or maintenance of the storage system occur, which severely hinders scientific discovery. To improve the data availability, data duplication and erasure coding (EC) are often used. But as the scientific data gets larger, using these two methods can cause considerable storage and network overhead.In this paper, we propose RAPIDS, a hybrid approach that combines the multigrid-based error-bounded lossy compression with erasure coding, to significantly reduce the storage and network overhead required for maintaining high data availability. Our experiments show that RAPIDS reduces the storage overhead by up to 7.5x and network overhead by up to 3x to achieve the same level of availability compared to the regular EC method. We improve RAPIDS by building two models to optimize the fault tolerance configurations and data gathering strategy. We demonstrate that RAPIDS significantly improves performance when running on many CPU cores in parallel or on GPUs.

Wan, Lipeng↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Subsurface Characterization and Machine Learning Predictions at Brady Hot Springs Results

Geothermal power plants typically show decreasing heat and power production rates over time. Mitigation strategies include optimizing the management of existing wells - increasing or decreasing the fluid flow rates across the wells - and drilling new wells at appropriate locations. The latter is expensive, time-consuming, and subject to many engineering constraints, but the former is a viable mechanism for periodic adjustment of the available fluid allocations. Data and supporting literature from a study describing a new approach combining reservoir modeling and machine learning to produce models that enable strategies for the mitigation of decreased heat and power production rates over time for geothermal power plants. The computational approach used enables translation of sets of potential flow rates for the active wells into reservoir-wide estimates of produced energy and discovery of optimal flow allocations among the studied sets. In our computational experiments, we utilize collections of simulations for a specific reservoir (which capture subsurface characterization and realize history matching) along with machine learning models that predict temperature and pressure timeseries for production wells. We evaluate this approach using an "open-source" reservoir we have constructed that captures many of the characteristics of Brady Hot Springs, a commercially operational geothermal field in Nevada, USA. Selected results from a reservoir model of Brady Hot Springs itself are presented to show successful application to an existing system. In both cases, energy predictions prove to be highly accurate: all observed prediction errors do not exceed 3.68% for temperatures and 4.75% for pressures. In a cumulative energy estimation, we observe prediction errors that are less than 4.04%. A typical reservoir simulation for Brady Hot Springs completes in approximately 4 hours, whereas our machine learning models yield accurate 20-year predictions for temperatures, pressures, and produced energy in 0.9 seconds. This paper aims to demonstrate how the models and techniques from our study can be applied to achieve rapid exploration of controlled parameters and optimization of other geothermal reservoirs. Includes a synthetic, yet realistic, model of a geothermal reservoir, referred to as open-source reservoir (OSR). OSR is a 10-well (4 injection wells and 6 production wells) system that resembles Brady Hot Springs (a commercially operational geothermal field in Nevada, USA) at a high level but has a number of sufficiently modified characteristics (which renders any possible similarity between specific characteristics like temperatures and pressures as purely random). We study OSR through CMG simulations with a wide range of flow allocation scenarios. Includes a dataset with 101 simulated scenarios that cover the period of time between 2020 and 2040 and a link to the published paper about this project, where we focus on the Machine Learning work for predicting OSR's energy production based on the simulation data, as well as a link to the GitHub repository where we have published the code we have developed (please refer to the repository's readme file to see instructions on how to run the code). Additional links are included to associated work led by the USGS to identify geologic factors associated with well productivity in geothermal fields. Below are the high-level steps for applying the same modeling + ML process to other geothermal reservoirs: 1. Develop a geologic model of the geothermal field. The location of faults, upflow zones, aquifers, etc. need to be accounted for as accurately as possible 2. The geologic model needs to be converted to a reservoir model that can be used in a reservoir simulator, such as, for instance, CMG STARS, TETRAD, or FALCON 3. Using native state modeling, the initial temperature and pressure distributions are evaluated, and they become the initial conditions for dynamic reservoir simulations 4....

15 GEOTHERMAL ENERGY↗

Deep Isolation-Development of the Safety Case for Disposal of Radioactive Wastes in Horizontal Boreholes - 20028

Deep Isolation has developed a safe, secure, and permanent geological disposal method for high-level waste, including spent nuclear fuel as well as sealed sources and other highly radioactive materials. The method leverages well established directional drilling technology to create horizontal repositories deep underground. The combination of great depth (1-3 km) and the ability to precisely position repositories in a horizontal orientation provides access to geologic strata that are inaccessible for typical mined and deep vertical borehole repositories. A number of potential direct and indirect safety benefits accrue including:1) greater depth below regional freshwater aquifers; 2) increased flexibility and more geologic options for siting; 3) access to deep formations with persistent and sustained reducing conditions. In addition there are a number of safety elements related specifically to the horizontal repository geometry including: 1) passive direction of thermally driven fluid and radionuclide movement away from the vertical access hole and toward the 'dead end' portion of the repository; 2) mitigation of seismic hazards by orienting repositories parallel to local and regional fault structures. In this paper we explore and discuss some of the key technologic, geologic and hydrologic elements that support the deep horizontal borehole safety case. The stalemate seen across the globe on the disposal of spent nuclear fuel and high-level waste can be broken. Deep Isolation offers a novel option for safe, secure, and permanent deep geological disposal of nuclear waste that can be developed as centralized repositories or adapted to smaller regional or site-specific repositories located near waste sources. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Testbed for Transmission Line Protection

Hardware in the loop (HIL) testing is crucial for designing and managing electric power grids. These grids are becoming larger and more complex. The importance for students to have safe and intuitive ways to interact with the devices associated with the power grids has never been more crucial. Since most of these tests involve high voltages, this can be a deterrent for instructors and students in undergraduate programs. HIL testing is a solution to these common issues. This method has become one of the most popular methods for testing these power systems. With the use of Western Michigan University’s (WMU) Real-Time Digital Simulator (RTDS) and SEL-421-7 protection relay, a HIL testbed has been created. These devices were interconnected using the communication protocol known as Generic Object-Oriented Substation Event (GOOSE). A simulated transmission line system was modeled in an RTDS software RSCAD as the basis for this testbed. This model simulated different types of faults that could occur in a transmission line while in operation. The SEL-421-7 relay is connected to the RSCAD simulation via GOOSE to protect our simulated transmission line. This testbed was set up to give students a clear understanding of how distance protection works as well as how the SEL-421-7 will react to various kinds of faults, in addition to how useful the RTDS can be when testing different power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Play-Based Exploration of CO 2 Storage in the Illinois Basin (Final Technical Report)

This report documents the results of "A Play-Based Exploration of CO₂ Storage in the Illinois Basin" (DE-FE0032366), a project funded by the U.S. Department of Energy Office of Fossil Energy and Carbon Management and conducted by the Illinois State Geological Survey (ISGS) at the University of Illinois Urbana-Champaign in partnership with Visage Energy. The project adapted play-based exploration (PBE), a systematic basin-scale evaluation methodology from the petroleum industry, to screen areas of Illinois for commercial geologic carbon storage (GCS) in Cambro-Ordovician strata. The traditional play concept was expanded to encompass three play element groups, subsurface geologic factors, surface features, and societal factors, yielding 24 play elements with defensible suitability criteria applied through a five-tier classification scheme. An integrated geospatial database was assembled from ISGS, MGSC, MRCI, NATCARB, and public data sources, supported by significant data-improvement work including correction of legacy well locations, digitization of more than 1,300 well construction records using the DOE CATALOG team's OGRRE tool, compilation of a statewide 2D seismic database, and production of a refined fault and fold geodatabase.

58 GEOSCIENCES↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Realistic Cost to Execute Practical Quantum Circuits using Direct Clifford+T Lattice Surgery Compilation

We report a resource estimation pipeline that explicitly compiles quantum circuits expressed using the Clifford+T gate set into a surface code lattice surgery instruction set. The cadence of magic state requests from the compiled circuit enables the optimization of magic state distillation and storage requirements in a post-hoc analysis. To compile logical circuits into lattice surgery operations, we build upon the open-source Lattice Surgery Compiler. The revised compiler operates in two stages: the first translates logical gates into an abstract, layout-independent instruction set; the second compiles these into local lattice surgery instructions that are allocated to hardware tiles according to a specified resource layout. The second stage retains logical parallelism while avoiding resource contention in the fault-tolerant layer, aiding realism. Additionally, users can specify dedicated tiles at which magic states are replenished, enabling resource costs from the logical computation to be considered independently from magic state distillation and storage. We demonstrate the applicability of our pipeline to large practical quantum circuits by providing resource estimates for the ground state estimation of molecules. Finally, we find that variable magic state consumption rates in real circuits can cause the resource costs of magic state storage to dominate unless production is varied to suit.

97 MATHEMATICS AND COMPUTING↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subsurface Characterization and Machine Learning Predictions at Brady Hot Springs: Preprint

Subsurface data analysis, reservoir modeling, and machine learning (ML) techniques have been applied to the Brady Hot Springs (BHS) geothermal field in Nevada, USA to further characterize the subsurface and assist with optimizing reservoir management. Hundreds of reservoir simulations have been conducted in TETRAD-G and CMG STARS to explore different injection and production fluid flow rates and allocations and to develop a training data set for ML. This process included simulating the historical injection and production since 1979 and prediction of future performance through 2040. ML networks were created and trained using TensorFlow based on multilayer perceptron (MLP), long short-term memory (LSTM), and convolutional neural network (CNN) architectures. These networks took as input selected flow rates, injection temperatures, and historical field operation data and produced estimates of future production temperatures. This approach was first successfully tested on a simplified single fracture doublet system, followed by the application to the BHS reservoir. Using an initial BHS dataset with 37 simulated scenarios, the trained and validated network predicted the production temperature for 6 production wells with the mean absolute percentage error of less than 8%. In a complementary analysis effort, the principal component analysis applied to 13 BHS geological parameters revealed that vertical fracture permeability shows the strongest correlation with fault density and fault intersection density. A new BHS reservoir model was developed considering the fault intersection density as proxy for permeability. This new reservoir model helps to explore under-exploited zones in the reservoir. A data gathering plan to obtain additional subsurface data was developed; it includes temperature surveying for three idle injection wells, at which the reservoir simulations indicate high bottom-hole temperatures. The collected data assist with calibrating the reservoir model and may lead to converting these wells to producers to access under-exploited zones in the reservoir. Data gathering activities are planned for the first quarter of 2021.

40 EE - Geothermal Technologies Office (EE-4G)↗

Geologic hydrogen: From natural occurrences to anthropogenic generation – A review of fundamentals, potential, challenges and prospects

Growing demand for hydrogen is exposing the environmental and economic limits of reforming-based and carbon-managed supply chains, while the scale-up of electrolytic capacity remains capital-constrained. Geologic hydrogen, defined as molecular H₂ generated and stored within the Earth's crust offers a complementary, potentially lower-cost resource, yet exploration is still ad hoc. This review (1) revisits a global inventory of confirmed hydrogen seeps and subsurface occurrences; (2) analyzes the controlling reactions, migration pathways, and trapping conditions governing these occurrences; (3) proposes a process-based geologic hydrogen system concept analogous to, yet distinct from, the petroleum system; and (4) evaluates potential geologic hydrogen systems within the United States as a representative case study. Here, we contrast natural systems powered by serpentinization, mantle degassing or radiolysis with anthropogenic systems that stimulate the same reactions or convert in-situ hydrocarbons. Stable hydrogen accumulations require generation rates that outpace combined physical, chemical and microbial losses; the Bourakébougou field (Mali) exemplifies a self-recharging, free-gas reservoir sustained by meteoric-water serpentinization beneath an efficient caprock. Prospective geologic hydrogen resources are likely to occur in regions where iron-rich lithologies, deep-seated faults, and low-permeability sealing formations coexist. Applying this principle, we highlight three promising hydrogen play types in U.S. geological terrains: ophiolite belts (Appalachian and Californian regions), the Midcontinent Rift and the Lake Superior banded‑iron formations. Multiphysics numerical models and positive-unlabeled machine-learning workflows help to accelerate play screening and de-risk future production; yet, reaction kinetics, stimulation strategies, and full techno-economic and life-cycle assessments remain pivotal knowledge gaps.

Anthropogenic hydrogen generation↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CarbonSAFE Phase II: Optimizing Alabama’s CO 2 Storage in Shelby County, Alabama (Project OASIS), Milestone M3 - Site Specific Drilling Report

The Phase II Storage Complex Feasibility project, entitled "Optimizing Alabama's CO 2 Storage in Shelby County, Alabama (Project OASIS)," is a part of the DOE/NETL's CarbonSAFE initiative. The Project is managed by the Southern States Energy Board (SSEB), and includes participation from Advanced Resources International, Inc. (ARI), Crescent Resource Innovation, Southern Company, Alabama A&M University, Auburn University, and Oklahoma State University. Project OASIS is working to establish the foundation for a commercial-scale geologic storage complex for CO 2 captured from Plant Gaston (home of the National Carbon Capture Center) and surrounding industrial sources of CO 2 located in Shelby County, Alabama. The Project objectives are: • Demonstrate that the subsurface saline formations at the storage complex can store commercial volumes of CO 2 safely and permanently. • Develop a comprehensive Community Benefits Plan. • Develop the infrastructure framework for a CO 2 storage hub. • Develop a rigorous risk registry and to conduct a comprehensive risk assessment. • Develop a monitoring plan. • Develop a comprehensive site characterization plan to support an Underground Injection Control Class VI Permit in a future Phase III program. • Evaluate the commercial viability of the project. Project OASIS is about 30 miles southeast of Birmingham, Alabama within a geologic province called the Valley and Ridge (Figure 1.1). The Valley and Ridge Province comprises a sequence of Paleozoic carbonate and clastic rocks that underwent structural deformation during the Alleghanian Orogeny. Storage prospects occur in relatively flat lying structural panels located between thrust faults. Available geologic studies related to hydrocarbon exploration suggest that Cambro-Ordovician carbonates and Cambrian clastic units offer multiple potential storage intervals, and that regional confining systems are present, such as the tectonically thickened Floyd-Parkwood Shale. The surface property is owned by a timber and land stewardship company, The Westervelt Company, Inc., who worked with the Project Team to select and prepare adequate sites for geologic assessment. The purpose of drilling the Westover Stratigraphic Test Well #2 was to collect geologic data to model the feasibility of commercial scale CO 2 injection and storage. This includes geological and geophysical evaluations, reservoir engineering analyses, and risk assessments.

20 FOSSIL-FUELED POWER PLANTS↗