At least 163 records · Page 9

DOE EV Data Collection - Maintenance Data

Maintenance data includes information on maintenance performed on the electric vehicles, including preventive maintenance, service calls, and availability of the vehicles. The parameters collected, and their definitions, will vary due to the differences in maintenance tracking systems that exist between fleets. Parameter definitions are detailed in the data dictionary, and specific vehicle information is available in the vehicle attributes table. Vehicle ID can be used as a key between maintenance data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FleetREDI Insight: Intrastate Coach Bus Dataset

Capturing real-world data is critical to improving efficiency and supporting technology advancements in commercial vehicles. FleetREDI’s insights provide detailed duty cycle information and highlight unique aspects of the given dataset. Each insight delivers a quick look at the collected data by summarizing the operation and identifying key findings of the initial analysis. This FleetREDI insight explores coach buses operating in Colorado. Coach buses are a primary mover for intrastate transit and are primarily used for longer trips with more comfortable seats and a restroom. All Aboard America! Holdings Inc. offers various fixed-service and charter routes across Colorado on its Bustang fleet out of its depot in Golden, Colorado. NLR installed logging devices and collected operational data on nine 40-foot Bustang motorcoaches operating on fixed routes from May through August 2022. Using NLR’s FleetREDI data platform, this dataset provides a summary of daily operation to help understand duty cycle characteristics. This includes daily distance, fuel use, and estimated engine-produced energy consumption for nine motorcoaches that operated more than 33,000 miles. These vehicles primarily operated on Interstate 25 and Interstate 70. ![FleetREDI interstate bus](FleetREDI-interstate-bus.jpg)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EV Champion Training Webinar 2: ZEV and EV Charging Planning [Slides]

The Electric Vehicle (EV) Champion Training Series, hosted by the National Renewable Energy Laboratory (NREL), is tailored for fleet managers, facility managers, and other stakeholders involved in the deployment of EVs and charging stations. This series equips participants with the skills and knowledge necessary to become subject matter experts in EV implementation. This is the second training in a four-part series and serves as an intermediate training. This training covers the first four steps in the ZEV Ready Center process, including how to identify and train your zero-emission vehicle (ZEV) team, align headquarters strategy with site-level planning, identify ZEV opportunities, and identify charging needs for your project sites. Participants will gain a solid foundation to support the effective deployment and management of EVs and their infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Overview of NLR Automated Mobility District Implementation Research - Phases I, II, and III. The Convergence of Automation, Electrification, and On-Demand Services: Enabling Resilient Automated Mobility Districts

A research program by the National Renewable Energy Laboratory has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings, referred to as Automated Mobility Districts (AMDs). An AMD emphasizes the deployment of automated vehicles (AV) passenger transport services within a dense urban setting and other major activity centers with intense passenger origin-destination demand patterns, such as those found in large business districts, airports, and university and medical campuses. Phase I and II surveyed 10 early deployment sites and subsequently collected and evaluated the lessons learned from these early deployment sites, with particular attention to fleet operations, impacts of service reliability, and vehicle technology evolution as the field of companies was being progressively winnowed by the challenges of full automation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Agent-Based, Bottom-Up Medium- and Heavy-duty Electric Vehicle Economics, Operation, Charging and Adoption (Research Performance Final Report)

This is the research performance final report for the project entitled: Agent-Based, Bottom-Up Medium- and Heavy-duty Electric Vehicle Economics, Operation, Charging and Adoption This project was able to achieve the DOE’s goals of developing new modeling tools to understand MDHD vehicle operation and adoption. The first modeling tool is a fleet-level techno-economic analysis model capable of estimating energy use and associated environmental and cost impacts for electrified and conventional vehicles of any MDHD vocation, using real-world cost and operations data, including approaches to optimizing schedules for charging and/or vehicle dispatch. The second modeling tool is a system-level, bottom-up, agent-based adoption model capable of generating geographically-resolved estimates of market projections for MDHD vehicles and charging infrastructure. These tools will be developed and published to serve dual purposes as analysis tools for researchers, and decision-support tools for decision makers within the MDHD system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Energy Management Program

The Federal Energy Management Program (FEMP) helps federal agencies manage their building and fleet energy use by providing training, tools, technical assistance, and funding.

DOE↗

Supercharging Your ZEV Transition: Using the ZEV Ready Planning Process

The ZEV Ready Framework is a step-by-step planning process for federal fleet electrification. The planning phase covers team coordination, training, policies, financial planning, and identifying candidates for zero-emission vehicles and electric vehicle supply equipment.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Sustainable Port Operations: Powered by NREL

Seaports are vital economic hubs that allow the United States to compete on a global scale. But the heavy vehicles and cargo equipment that enable their operations also emit harmful air pollutants and greenhouse gas emissions. For nearly two decades, National Renewable Energy Laboratory (NREL) researchers have worked toward comprehensive seaport decarbonization. They fuse world-class analysis with deep vehicle and transportation systems knowledge to guide strategic deployment of low- and zero-emissions vehicles, charging and refueling infrastructure, and grid improvements. Together, these capabilities can enable sustainable port operations. This fact sheet outlines major seaport and airport decarbonization capabilities across the laboratory, including: fleet research, energy data, and insights for decarbonization; comprehensive hydrogen infrastructure deployment; optimized charging through grid integration; strategic blueprinting for clean, optimized technology deployment; and integrating diversity, equity, inclusion, and accessibility considerations into decarbonization efforts.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Regulatory Coordination of Photophysical, Photochemical, and Biochemical Reactions in the Photosynthesis of Land Plants

Balance among the sequential photophysical, photochemical, and biochemical reactions of photosynthesis is needed for converting fleeting energy in light to stable energy in chemical bonds. Any imbalance acts as either a bottleneck for limiting photosynthetic efficiency or an agent for inducing structural and functional damage to photosynthetic apparatus. Not only must each reaction be carefully regulated, but regulatory processes must also be coordinated across the reactions. However, regulations of different stages of photosynthesis have rarely been studied jointly. Non-photochemical quenching (NPQ) and stomatal conductance (g s ) are key regulators of photophysical and biochemical reactions, respectively. Existing evidence suggests that the redox state of plastoquinone regulates g s and that the photochemical reactions are partially regulated by the ultrastructural dynamics of thylakoids induced by osmotic water fluxes in chloroplasts of land plants. To examine how these regulations are coordinated and feedback to each other, we simultaneously measured NPQ and gs and inferred the redox state of plastoquinone and the light-induced thylakoid swelling/shrinking on numerous C 3 and C 4 species. For all species measured, NPQ and gs covary with the redox states of the electron transport chain, particularly plastoquinone, and increase as thylakoid swelling is inferred. NPQ has the maximal sensitivity at the light intensity at which thylakoid is inferred to be fully swollen. Our findings suggest that plant energy and water use strategies are intimately linked by evolution, and studying the regulations of different photosynthetic stages as a whole can lead to new insights of the functioning of photosynthetic machinery in dynamic environments.

59 BASIC BIOLOGICAL SCIENCES↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Field validation of dynamic mechanical torque measurements using fiber-optic strain sensors for geared wind turbines

Abstract Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory’s Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors’ successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

A study on the impact of using a subchannel resolution for modeling of large break loss of coolant accidents

The nuclear industry is investigating the feasibility of transitioning from 18- to 24-month fuel cycles because of the positive impact it would have on the operational costs for the current fleet of light-water reactors. A challenge to making this change is the increased risk of fuel fragmentation, relocation, and dispersal (FFRD) due to the known potential for ceramic fuel to pulverize into fine particles at the higher discharge burnups. Previous work has been performed by the Nuclear Energy Advanced Modeling and Simulation program to assess FFRD risk in high-burnup cores using the BISON fuel performance code and a coarse mesh thermal hydraulics (T/H) solution for a loss-of-coolant accident (LOCA) using the TRACE system T/H code. Because of the importance of the T/H solution for FFRD assessment, this study seeks to investigate the impact of using higher-fidelity subchannel techniques for modeling of the LOCA transient. CTF was used to model a subregion of a high-burnup core that was depleted by the Virtual Environment for Reactor Applications (VERA) multiphysics core simulator. Both coarse-mesh and pin-resolved models were created in CTF, and a consistent coarse-mesh TRACE model was also developed to allow for benchmarking the code results. Further, a large-break loss-of-coolant accident (LBLOCA) reflood transient was simulated using these three models, and results were compared. Results showed some consistent differences between the CTF and TRACE coarse models, including a higher peak cladding temperature (PCT) prediction in CTF and later quenching in CTF; however, the transient clad temperature behavior was similar, and these differences are likely due to post-critical heat flux heat transfer modeling differences and minimum film boiling temperature model differences. The pin-resolved results indicate that the PCT in the lumped model is often under-predicted by as much as 70 °C and that PCT occurs at a different location than the high-power pin in the assembly. The lumped model predicts a difference of 10 °C or less between the average and hot pins in the assembly, whereas the pin-resolved model predicts a range of over 100 °C. These results indicate that higher-fidelity T/H results may have an impact on predicted core behavior during LOCA, which may be important to consider when assessing FFRD risk.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-burnup boiling water reactor steady-state operating conditions and fuel performance analysis

The primary operational costs for existing nuclear reactors are plant operation costs, maintenance costs, and fuel costs, all of which are influenced by the materials used and the design of the reactor core. Optimizing core design parameters—including burnup limits and enrichment levels—can lengthen cycles, reduce outages, reduce reload batch fractions and spent fuel storage requirements, and lower maintenance and operating expenses, thereby enhancing economic viability. Furthermore, developing higher-fidelity tools to simulate these parameters enables better identification of the available margin, improves overall plant safety, and improves the understanding a given plant’s responses to accident scenarios. Here, in the US, much of the research and development focus has traditionally been on pressurized water reactors (PWRs), but boiling water reactors (BWRs) comprise approximately one-third of the US reactor fleet. Modeling and simulation advances for BWRs and PWRs—particularly those achieved through the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program—are crucial to the long-term viability of the light–water reactor industry. A key research area of the high burnup and increased enriched fuel initiative is focused on addressing issues related to postulated loss-of-coolant accident (LOCA) scenarios. NEAMS has dedicated significant effort to enhancing tools to better support BWRs. A current focus is showcasing the BWR framework for high-burnup LOCA analysis. This high-fidelity steady-state analysis is a first step toward demonstrating a best-estimate, pin-by-pin high-burnup BWR LOCA analysis to assess full-core cladding rupture behavior for a representative BWR. The objective of this effort is to provide a modeling capability that will help elucidate and provide a best-estimate evaluation for cladding rupture susceptibility in BWRs. This modeling capability could then be used to prevent and/or mitigate cladding ruptures in postulated accident scenarios without penalizing operational parameters. Additionally, the results of this work will help identify strategies for finding additional margins or potentially limiting cladding ruptures through core design optimizations to enable more efficient core designs.

Capps, Nathan [Oak Ridge National Laboratory (ORNL↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗

A real-time energy and cost efficient vehicle route assignment neural recommender system

Here, this paper presents a neural network recommender system algorithm for assigning vehicles to routes based on energy and cost criteria. In this work, we applied this new approach to efficiently identify the most cost-effective medium and heavy duty truck (MDHDT) powertrain technology, from a total cost of ownership (TCO) perspective, for given trips. We employ a machine learning based approach to efficiently estimate the energy consumption of various candidate vehicles over given routes, defined as sequences of links (road segments), with little information known about internal dynamics, i.e. using high level macroscopic route information. A complete recommendation logic is then developed to allow for real-time optimum assignment for each route, subject to the operational constraints of the fleet. We show how this framework can be used to (1) efficiently provide a single trip recommendation with a top-k vehicles star ranking system, and (2) engage in more general assignment problems where n vehicles need to be deployed over m (m ≤ n) trips. This new assignment system has been deployed and integrated into the POLARIS. Transportation System Simulation Tool for use in research conducted by the Department of Energy's Systems and Modeling for Accelerated Research in Transportation (SMART) Mobility Consortium (SMART, 2024).

Energy consumption↗

The past, present, and future of peaking thermal power plants in the United States

Today's power systems rely on "peaker plants" to reliably serve load during peak demand periods. In this study we consider the present competitiveness of different peaking options, how much and what kinds of plants have provided U.S. peaking capacity, and potential future peaking fleet compositions. We explore how capital intensity impacts the breakeven capacity factor between two potential resources: combustion turbines (CTs) and combined cycle plants (CCs). CTs outcompete CCs below 12%-17% annual capacity factor at today's prices, but can shift with changes to fuel or start costs. Historically, gas CTs and petroleum steam plants most closely fit the role of peakers. Peaking capacity could grow from approximately 280 GW today to 460-770 GW in 2050 composed of a wider range of resources. We conclude by discussing implications of this shift, with a focus on the potential planning considerations for shifting to a greater utilization of CCs for peaking needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A census of fish passage facilities at US hydropower developments across the conterminous United States

Hydropower provides reliable and secure electricity and contributes significantly to the flexibility and stability of the US electricity grid. Hydropower dams generally are aquatic barriers and hazards to migratory fish in rivers. Fish passage facilities mitigate risks from hydropower to migratory fish, but information on these facilities is incomplete for the conterminous United States (CONUS). Here, we present the first CONUS-scale dataset of fish passage facilities at US hydropower developments in over 30 years. The existence of fish passage facilities (presence or absence) was specified for 1909 hydropower features, 390 of which had at least one facility. Most features had a single passage facility that provided passage in only one direction, with downstream being more common than upstream passage. Bypasses and ladders accounted for 60 % of the fish passage facility types. While we documented 659 fish passage facilities across CONUS, facilities were most common in the New England, Pacific Northwest, Mid-Atlantic, and Great Lakes regions. In general, fish passage facilities were more common at features that were closer to the ocean, at lower elevations, and at shorter dams, but not related to installed electrical generation capacity. Hydrologic sub-basins containing salmonids also contained the largest number of hydropower features, but the proportion of features with passage was generally higher in sub-basins containing multiple migratory taxa. This census provides valuable information on existing fish passage mitigation and is a benchmark to gauge progress toward a modernized hydropower fleet that provides affordable, reliable energy while protecting fishery resources and river ecosystems.

13 HYDRO ENERGY↗

An approach to combine neutron and ion irradiation data to accelerate material qualification for nuclear reactors

Next-generation nuclear power plants are generally characterized by higher operating temperatures, increased neutron fluences and energies, and distinct corrosive coolant environments versus the existing light water reactor fleet. Whether using existing materials in new environments, newly developed materials tailored for these environments, or new manufacturing methods, the traditional decades-long approach for materials qualification does not facilitate rapid deployment. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. Because microstructure has a large impact on bulk material properties, limited neutron irradiation data at lower damage levels can in principle be combined with accelerated ion testing results and modeling and simulation to form an accurate prediction of microstructure evolution and select properties under different neutron irradiation conditions and at higher damage levels. The objective of this work is to present a conceptual framework of specific steps to fulfill several technical challenges associated with qualifying materials for performance in radiation environments on an accelerated time frame. A brief review of the regulatory landscape for materials in nuclear environments is presented, followed by additional overviews to understand the current state of the art for correlation of materials properties across radiation environments using experimental and computational methodologies. Finally, the roles of academia, national laboratories, and industry in the advancement of this accelerated materials qualification framework are discussed as a path forward, with possible case studies presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗