Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Active Flow Control Activities at NASA Langley

NASA Langley continues to aggressively investigate the potential advantages of active flow control over more traditional aerodynamic techniques. This paper provides an update to a previous paper and describes both the progress in the various research areas and the significant changes in the NASA research programs. The goals of the topics presented are focused on advancing the state of knowledge and understanding of controllable fundamental mechanisms in fluids as well as to address engineering challenges. An organizational view of current research activities at NASA Langley in active flow control as supported by several projects is presented. On-center research as well as NASA Langley funded contracts and grants are discussed at a relatively high level. The products of this research are to be demonstrated either in bench-top experiments, wind-tunnel investigations, or in flight as part of the fundamental NASA R&D program and then transferred to more applied research programs within NASA, DOD, and U.S. industry.

Anders, Scott G.↗

Data Analysis for the NASA/Boeing Hybrid Laminar Flow Control Crossflow Experiment

The Hybrid-Laminar Flow Control (HLFC) Crossflow Experiment, completed in 1995. generated a large database of boundary layer stability and transition data that was only partially analyzed before data analysis was abruptly ended in the late 1990's. Renewed interest in laminar flow technologies prompted additional data analysis, to integrate all data, including some post-test roughness and porosity measurements. The objective is to gain new insights into the effects of suction on boundary layer stability. A number of challenges were encountered during the data analysis, and their solutions are discussed in detail. They include the effect of the probe vibration, the effect of the time-varying surface temperature on traveling crossflow instabilities, and the effect of the stationary crossflow modes on the approximation of wall location. Despite the low turbulence intensity of the wind tunnel (0.01 to 0.02%), traveling crosflow disturbances were present in the data, in some cases at amplitudes up to 1% of the freestream velocity. However, the data suggests that transition was dominated by stationary crossflow. Traveling crossflow results and stationary data in the presence of suction are compared with linear parabolized stability equations results as a way of testing the quality of the results.

Eppink, Jenna L.↗

Flow-Control Devices For Inlets Of Indraft Wind Tunnels

Report presents theoretical and experimental study of effects of antiturbulence flow-control devices in inlet of indraft wind tunnel upon nonuniformity of flow in test section of tunnel. Flow-control devices in question include vanes, screens, and honeycombs, placed in inlet upstream of contracting section of tunnel leading from inlet to test section.

Ross, James C.↗

Study of the application of advanced technologies to laminar flow control systems for subsonic transports. Volume 1: Summary

A study was conducted to evaluate the technical and economic feasibility of applying laminar flow control to the wings and empennage of long-range subsonic transport aircraft compatible with initial operation in 1985. For a design mission range of 10,186 km (5500 n mi), advanced technology laminar-flow-control (LFC) and turbulent-flow (TF) aircraft were developed for both 200 and 400-passenger payloads, and compared on the basis of production costs, direct operating costs, and fuel efficiency. Parametric analyses were conducted to establish the optimum geometry for LFC and TF aircraft, advanced LFC system concepts and arrangements were evaluated, and configuration variations maximizing the effectiveness of LFC were developed. For the final LFC aircraft, analyses were conducted to define maintenance costs and procedures, manufacturing costs and procedures, and operational considerations peculiar to LFC aircraft. Compared to the corresponding advanced technology TF transports, the 200- and 400-passenger LFC aircraft realized reductions in fuel consumption up to 28.2%, reductions in direct operating costs up to 8.4%, and improvements in fuel efficiency, in ssm/lb of fuel, up to 39.4%. Compared to current commercial transports at the design range, the LFC study aircraft demonstrate improvements in fuel efficiency up to 131%. Research and technology requirements requisite to the development of LFC transport aircraft were identified.

Sturgeon, R. F.↗

Feasibility and benefits of laminar flow control on supersonic cruise airplanes

An evaluation was made of the applicability and benefits of laminar flow control (LFC) technology to supersonic cruise airplanes. Ancillary objectives were to identify the technical issues critical to supersonic LFC application, and to determine how those issues can be addressed through flight and wind-tunnel testing. Vehicle types studied include a Mach 2.2 supersonic transport configuration, a Mach 4.0 transport, and two Mach 2-class fighter concepts. Laminar flow control methodologies developed for subsonic and transonic wing laminarization were extended and applied. No intractible aerodynamic problems were found in applying LFC to airplanes of the Mach 2 class, even ones of large size. Improvements of 12 to 17 percent in lift-drag ratios were found. Several key technical issues, such as contamination avoidance and excresence criteria were identified. Recommendations are made for their resolution. A need for an inverse supersonic wing design methodology is indicated.

Powell, A. G.↗

Preliminary design characteristics of a subsonic business jet concept employing laminar flow control

Aircraft configurations were developed with laminar flow control (LFC) and without LFC. The LFC configuration had approximately eleven percent less parasite drag and a seven percent increase in the maximum lift-to drag ratio. Although these aerodynamic advantages were partially offset by the additional weight of the LFC system, the LFC aircraft burned from six to eight percent less fuel for comparable missions. For the trans-atlantic design mission with the gross weight fixed, the LFC configuration would carry a greater payload for ten percent fuel per passenger mile.

Turriziani, R. V.↗

Wind Tunnel Experiment of Microjet-based Flow Control on a Multi-Element High-Lift Airfoil

A wind tunnel model was designed, manufactured, and tested to evaluate the potential of active aerodynamic flow control for multi-element airfoils. The active flow control system involves so-called microjets –small, low momentum, normal to the surface jets located near the trailing edge of the flap –for controlling the lift and improving the aerodynamic performance characteristics of airplane high-lift systems. The configuration selected for this test is the NLR7301 two-element airfoil and it was tested in the Oran W. Nicks Low-Speed Wind Tunnel at Texas A&M University at a chord Reynolds number of 2.0 million and Machnumber of 0.10. This paper presents wind tunnel results for the NLR7301 in the Flap 20 and Flap 30 configurations. The wind tunnel results include surface pressure distributions, lift and pitching moment, and flow visualizations.The results of this experiment validate the effectiveness of the microjet with regards to control of lift in the linear regime for multi-element airfoils.

ARMD↗

Implementation of Real-Time Feedback Flow Control Algorithms on a Canonical Testbed

This report summarizes the activities on "Implementation of Real-Time Feedback Flow Control Algorithms on a Canonical Testbed." The work summarized consists primarily of two parts. The first part summarizes our previous work and the extensions to adaptive ID and control algorithms. The second part concentrates on the validation of adaptive algorithms by applying them to a vibration beam test bed. Extensions to flow control problems are discussed.

Tian, Ye↗

Application of computational fluid dynamics to the study of vortex flow control for the management of inlet distortion

A study is presented to demonstrate that the Reduced Navier-Stokes code RNS3D can be employed effectively to develop a vortex generator installation that minimizes engine face circumferential distortion by controlling the development of secondary flow. The necessary computing times are small enough to show that similar studies are feasible within an analysis-design environment with all its constraints of costs and time. This study establishes the nature of the performance enhancements that can be realized with vortex flow control, and indicates a set of aerodynamic properties that can be utilized to arrive at a successful vortex generator installation design.

Anderson, Bernhard H.↗

Application of stability theory to laminar flow control - Progress and requirements

Paper briefly summarizes the current status of linear stability theory as applied to laminar flow control for aerodynamics. Results indicate that the conventional 'N factor' method of correlating stability theory and transition has a broad application range, including low- and high-speeds, two- and three-dimensional mean flow and TS, Gortler and crossflow disturbance modes. Linear theory is particularly applicable to the laminar flow control problem as, for system efficiency, control must be exercised and disturbances maintained in the linear regime. Current areas of concern for LFC, which require further stability theory research, include TS-crossflow interaction, combined disturbance fields (roughness, waviness, noise) and suction-induced disturbances. Some results on wave-interactions are presented.

Bushnell, D. M.↗

Lockheed laminar-flow control systems development and applications

Progress is summarized from 1974 to the present in the practical application of laminar-flow control (LFC) to subsonic transport aircraft. Those efforts included preliminary design system studies of commercial and military transports and experimental investigations leading to the development of the leading-edge flight test article installed on the NASA JetStar flight test aircraft. The benefits of LFC on drag, fuel efficiency, lift-to-drag ratio, and operating costs are compared with those for turbulent flow aircraft. The current activities in the NASA Industry Laminar-Flow Enabling Technologies Development contract include summaries of activities in the Task 1 development of a slotted-surface structural concept using advanced aluminum materials and the Task 2 preliminary conceptual design study of global-range military hybrid laminar flow control (HLFC) to obtain data at high Reynolds numbers and at Mach numbers representative of long-range subsonic transport aircraft operation.

Lange, Roy H.↗

Effects of laminar flow control on the performance of a large span-distributed-load flying-wing cargo airplane concept

The effects of laminar flow control (LFC) on the performance of a large span-distributed-load flying-wing cargo airplane concept having a design payload of 2.669 MN and range of 5.93 Mm were determined. Two configurations were considered. One employed laminarized flow over the entire surfaces of the wing and vertical tails, with the exception of the estimated areas of interference due to the fuselage and engines. The other case differed only in that laminar flow was not applied to the flaps, elevons, spoilers, or rudders. The two cases are referred to as the 100 percent and 80 percent laminar configurations, respectively. The utilization of laminar flow control results in reductions in the standard day, sea level installed maximum static thrust per engine from 240 kN for the non-LFC configuration to 205 kN for the 100 percent laminar configuration and 209 kN for the 80 percent case. Weight increases due to the LFC systems cause increases in the operating empty weights of approximately 3 to 4 percent. The design takeoff gross weights decrease approximately 3 to 5 percent. The FAR-25 takeoff field distances for the LFC configurations are greater by about 6 to 7 percent. Fuel efficiencies for the respective configurations are increased 33 percent and 23 percent.

Jernell, L. S.↗

Blended Wing Body Systems Studies: Boundary Layer Ingestion Inlets With Active Flow Control

A CFD analysis was performed on a Blended Wing Body (BWB) aircraft with advanced, turbofan engines analyzing various inlet configurations atop the aft end of the aircraft. The results are presented showing that the optimal design for best aircraft fuel efficiency would be a configuration with a partially buried engine, short offset diffuser using active flow control, and a D-shaped inlet duct that partially ingests the boundary layer air in flight. The CFD models showed that if active flow control technology can be satisfactorily developed, it might be able to control the inlet flow distortion to the engine fan face and reduce the powerplant performance losses to an acceptable level. The weight and surface area drag benefits of a partially submerged engine shows that it might offset the penalties of ingesting the low energy boundary layer air. The combined airplane performance of such a design might deliver approximately 5.5% better aircraft fuel efficiency over a conventionally designed, pod-mounted engine.

Geiselhart, Karl A.↗

Design and fabrication of large suction panels with perforated surfaces for laminar flow control testing in a transonic wind tunnel

Considerable progress has been made in the development of perforated suction surface material for laminar flow control applications. Electron-beam perforated titaniuum skin was used as the suction surface. Critical issues related to suction panel manufacturing were identified and largely resolved. The final product included fabrication of a 7-foot chord by 7-foot span perforated laminar flow control wind tunnel model. Techniques used can be adapted to modern aircraft production lines. The report includes details on panel instrumentation and other features required for testing in a transonic pressure tunnel.

Maddalon, D. V.↗

Experimental and Computational Validation of a Novel Particle Flow Control Valve for CSP Systems

Particle-based Concentrated Solar Power (CSP) systems most often utilize the state-of-the art slide gate mechanism for particle flow control. The slide-gate was found to have a sensitivity of 0.354 g/s-mm, a measure of mass flow rate over actuation position [1]. Particle-based CSP developers have noted that the slide gate is conducive to particle lodging, leaking, and difficulty actuating under particle pressure as well as differential expansion of the gate from thermal cycling. The goal of this work is to design, develop and test a novel particle flow control device that can operate without any hindrance from these shortcomings.

14 SOLAR ENERGY↗

A Robust Design Methodology for Optimal Microscale Secondary Flow Control in Compact Inlet Diffusers

It is the purpose of this study to develop an economical Robust design methodology for microscale secondary flow control in compact inlet diffusers. To illustrate the potential of economical Robust Design methodology, two different mission strategies were considered for the subject inlet, namely Maximum Performance and Maximum HCF Life Expectancy. The Maximum Performance mission maximized total pressure recovery while the Maximum HCF Life Expectancy mission minimized the mean of the first five Fourier harmonic amplitudes, i.e., 'collectively' reduced all the harmonic 1/2 amplitudes of engine face distortion. Each of the mission strategies was subject to a low engine face distortion constraint, i.e., DC60<0.10, which is a level acceptable for commercial engines. For each of these missions strategies, an 'Optimal Robust' (open loop control) and an 'Optimal Adaptive' (closed loop control) installation was designed over a twenty degree angle-of-incidence range. The Optimal Robust installation used economical Robust Design methodology to arrive at a single design which operated over the entire angle-of-incident range (open loop control). The Optimal Adaptive installation optimized all the design parameters at each angle-of-incidence. Thus, the Optimal Adaptive installation would require a closed loop control system to sense a proper signal for each effector and modify that effector device, whether mechanical or fluidic, for optimal inlet performance. In general, the performance differences between the Optimal Adaptive and Optimal Robust installation designs were found to be marginal. This suggests, however, that Optimal Robust open loop installation designs can be very competitive with Optimal Adaptive close loop designs. Secondary flow control in inlets is inherently robust, provided it is optimally designed. Therefore, the new methodology presented in this paper, combined array 'Lower Order' approach to Robust DOE, offers the aerodynamicist a very viable and economical way of exploring the concept of Robust inlet design, where the mission variables are brought directly into the inlet design process and insensitivity or robustness to the mission variables becomes a design objective.

Anderson, Bernhard H.↗