Laser Velocimeter Measurements of the Flow Within a Vane-Island Diffuser
A series of detailed non-intrusive laser velocimeter flow field surveys were performed to validate computational fluid dynamic (CFD) codes for rotating pump components. Three component laser-2-focus (L2F) laser velocimetry was used to acquire data within a flow passage of a diffuser at design flow conditions. The thirteen vane-island type diffuser was designed to allow diffusion in the axial direction. Multiple laser velocimeter surveys were performed throughout several diffuser passages and at multiple diffuser depths (hub to shroud). The axial (3D) component of the velocity at all locations was small. The radial and meridional velocity components nearest the diffuser hub increased in magnitude relative to the flow nearest the shroud as the flow progressed through the diffuser. A continuity check across the diffuser throat and based on the meridional velocity component yielded a match with a facility flow meter of 98.0%.