At least 163 records · Page 9

Impacts of caking on corn stover – An assessment of moisture content and consolidating pressure

Caking or time consolidation of powders is a serious problem which can hinder productivity and overall feasibility of various industrial processes. Here this study focuses on the impacts moisture content and consolidating pressures can have on 2 mm corn stover samples after undergoing a drying treatment at different times. Individually, moisture content and consolidating pressure did not exhibit any significant changes throughout the modified variable flow rate tests using the FT4 powder rheometer. However, applying both variables simultaneously yielded higher-than-usual energy outputs from the corn stover, indicative of biomass agglomeration due to the moisture and its subsequent evaporation while under pressure via the induced consolidating pressure. However, despite the increase in energy usage, time dried did not have a direct effect and demonstrated no trend.

36 MATERIALS SCIENCE↗

Multidisciplinary Constraints on the Thermal‐Chemical Boundary Between Earth's Core and Mantle

Abstract Heat flux from the core to the mantle provides driving energy for mantle convection thus powering plate tectonics, and contributes a significant fraction of the geothermal heat budget. Indirect estimates of core‐mantle boundary heat flow are typically based on petrological evidence of mantle temperature, interpretations of temperatures indicated by seismic travel times, experimental measurements of mineral melting points, physical mantle convection models, or physical core convection models. However, previous estimates have not consistently integrated these lines of evidence. In this work, an interdisciplinary analysis is applied to co‐constrain core‐mantle boundary heat flow and test the thermal boundary layer (TBL) theory. The concurrence of TBL models, energy balance to support geomagnetism, seismology, and review of petrologic evidence for historic mantle temperatures supports Q CMB ∼15 TW, with all except geomagnetism supporting as high as ∼20 TW. These values provide a tighter constraint on core heat flux relative to previous work. Our work describes the seismic properties consistent with a TBL, and supports a long‐lived basal mantle molten layer through much of Earth's history.

58 GEOSCIENCES↗

Evaluating aqueous flow battery electrolytes: a coordinated approach

Here, we outline some basic pitfalls in the electrochemical investigation of aqueous metal complexes and advocate for the use of bulk electrolysis in redox flow cells for electrolyte analysis. We demonstrate the methods of operation and performance of a lab scale redox flow battery (RFB), which is assembled from unmodified, commercially available material and cycled with a vanadium electrolyte in order to provide a comparative baseline of expected performance. Common misconceptions about the thermodynamic window for water splitting are addressed and further express the need to develop next-generation aqueous redox flow battery electrolytes. Although non-aqueous electrolytes are a popular approach, they suffer from distinct challenges that limit energy and power density in comparison with aqueous electrolytes. Expanding the scope of aqueous electrolytes to include metal–chelate complexes allows electrolytes to be as tailorable as organic species, while maintaining robust metal-based redox processes. A flow battery assembly and operation guide is provided to help facilitate the use of flow battery testing in the evaluation of next-generation electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can late dark energy transitions raise the Hubble constant?

Late times dark energy transitions at redshifts z << 0.1 can raise the predicted value of the Hubble constant to the SH0ES value, 74.03 ± 1.42 (km s –1 Mpc –1 ) or more, while providing an equally good fit as Λ CDM at 67.73±0.41 to higher redshift data, in particular from the cosmic microwave background and baryon acoustic oscillations. Here, these models however do not fully resolve the true source of tension between the distance ladder and high redshift observations: the local calibration of supernovae luminosities well out into the Hubble flow. When tested in this manner by transferring the SH0ES calibration to the Pantheon supernovae dataset, the ability of such transitions to raise the Hubble constant is reduced to 69.17 ± 1.09. Such an analysis should also be used when testing any dynamical dark energy model which can produce similarly fine features in redshift or local void models.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyzing Custom Proof Masses and Quantum Limits of a Manufacturable Cavity Optical Levitation Solution

This report details results of a one-year LDRD to understand the dynamics, figures of merit, and fabrication possibilities for levitating a micro-scale, disk-shaped dielectric in an optical field. Important metrics are the stability, positional uncertainty, and required optical power to maintain levitation. Much of the results are contained in a publication written by our academic alliance collaborators. Initial structures were grown at Sandia labs and a test fabrication flow was executed. Owing to our strength in VCSEL lasers, we were particularly interested in calculations and fabrication flows that could be compatible with a VCSEL light source.

42 ENGINEERING↗

Acetonitrile Destruction in ETF Feed Solutions by UV/OX and Persulfate (Final Report)

The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams that include condensates from the 242-A evaporator, leachate from the Environmental Restoration Disposal Facility (ERDF), as well as laboratory wastes and, in the future, will treat liquid effluents from the Hanford Waste Treatment and Immobilization Plant (WTP) and Integrated Disposal Facility (IDF) leachate. Liquid effluents from the WTP will have significant concentrations of acetonitrile. Acetonitrile is formed by reaction of nitrates and sugar in the WTP low activity waste (LAW) melters and is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed low activity waste (DFLAW) flow-sheet, testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the ETF, this creates a potential issue with the ETF waste acceptance criteria and, specifically, the ETF Delisting Modification treatability envelope limits. Consequently, there is a need to assess possible mitigation approaches, one of which involves identification and assessment of potential treatment processes to destroy the acetonitrile, which is the subject of the present report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scalable Fabrication of a Fibrous Amine-functionalized Matrix (FAM) Sorbent for Critical Mineral Recovery

We report a novel flat sheet Fibrous Amine-functionalized Matrix (FAM) sorbent platform designed for efficient and selective capture of CM from dilute solutions. The FAM sorbent features crosslinked amine microfilms coated onto/within a glass fiber matrix, providing fast mass transfer and excellent mechanical stability. Systematic batch and flow-through tests with FAM revealed rapid metal uptake kinetics and high capacity for representative species, achieving ~90 mg/g of Gallium, ~100 mg/g of Cobalt, and ~90 mg/g for Neodymium. Moreover, multiple eluents, including mineral acids and complexing agents, enabled highly effective desorption of adsorbed metals, demonstrating the feasibility of regenerating FAM sorbents. Importantly, tests with authentic coal ash leachate demonstrated strong selectivity toward U.S. Department of Energy (DOE)-listed CM and rare earth elements over abundant base cations, confirming the robustness of FAM in realistic complex solutions. The flat sheet geometry was amenable to scaling into durable spiral wound modules, highlighting the potential for future regeneration and reuse. This work establishes FAM sorbents as a promising platform for the recovery of CM from wastewaters, advancing both resource sustainability and environmental stewardship.

critical mineral recovery↗

Control of Cement Timing, Mineralogy, and Texture on Hydro-chemo-mechanical Coupling from CO2 Injection into Sandstone: A Synthesis

Carbon capture, utilization, and storage (CCUS) has been widely applied to enhance oil recovery (CO2-EOR). A thorough investigation of the impact of injecting CO2 into a heterogeneous reservoir is critical to understanding the overall reservoir robustness and storage performance. We conducted fifteen flow-through tests on Morrow B sandstone that allowed for chemical reactions between a CO2-rich brackish solution and the sandstones, and four creep/flow-through tests that simultaneously allowed for chemical reactions and stress monitoring. From fluid chemistry and X-ray computed tomography, we found that the dissolution of disseminated cements and the precipitation of iron-rich clays did not significantly affect the permeability and geomechanical properties. Minor changes in mechanical properties from Brazilian and creep tests indicated that the matrix structure was well-supported by early diagenetic quartz overgrowth cement and the reservoir’s compaction history at deep burial depths. However, one sample experienced a dissolution of poikilotopic calcite, leading to a permeability increase and significant tensile strength degradation due to pore opening, which overcame the effect of the early diagenetic cements. We concluded that the Morrow B sandstone reservoir is robust for CO2 injection. Most importantly, cement timing, the abundance and texture of reactive minerals, and the reservoir’s burial history are critical in predicting reservoir robustness and storage capacity for CO2 injection.

Wu, Zhidi (ORCID:0000000338869492)↗

Heat Transfer of an Integrated Counterflow Ceramic Heat Exchanger

The ceramic-based heat exchanger is one of the leading contenders for high-efficiency concentrating solar power plants using a molten salt heat transfer fluid and a supercritical carbon dioxide Brayton power cycle operating at temperatures above 700 °C due to the excellent resistance of ceramics to corrosion, oxidation, erosion, creep, and fouling. In the present study, the thermal performance of a ceramic silicon carbide prototype heat exchanger, with semi-elliptical heat transfer channels, integrated header channels, and a counterflow configuration fabricated by using binder jetting additive manufacturing, was experimentally investigated. Experimental heat transfer tests of the prototype were conducted at high temperatures and under various test fluid flow rates and inlet temperatures. The experimental heat transfer rates compared favorably with simulation predictions.

Yu, Wenhua (ORCID:0000000219457014)↗

PV High Wind User Test Facility

The creation of a PV high wind test facility at the NREL Flatirons Campus that will enable private and public research efforts aimed at storm hardening PV systems. The facility will be instrumented to monitor effects of high wind conditions on modules and other array components. These in-field tests will coordinate with flow models, wind tunnel testing, validation of PV aeroelastic design codes, and post-testing module and system component analysis.

14 SOLAR ENERGY↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Intensified Catalytic Conversion of CO2 into High Value Chemicals

The utilization of CO2 produced from power generation plants as a feedstock for creating new valuable products offers a strategy to reduce GHG emissions, offset carbon capture costs, and facilitate the rebalancing of the carbon cycle. After considering the thermodynamic requirement of potential products from CO2 utilization and their market size, formic acid is a desirable target that offers widespread utility in industrial chemical production and chemical energy storage as a liquid fuel. To effectively utilize CO2 from power generation plants, UK proposes an enhanced bimetallic oxide carbon utilization process (EBOCU) that enables electrochemical CO2 conversion to formic acid. The UK intensified electrocatalytic process combines three main components: 1) a novel bimetallic oxide electrocatalyst; 2) a stable electrochemical reactor using robust electrodes; and 3) a pressurized electrochemical reactor. The output from this project showed the economic viability of producing high-value formic acid from CO2 to both offset the cost associated with post-combustion CCS and reduce GHG emissions. This project developed and screened a series engineered catalysts to selectively reduce CO2 directly to formic acid. The best performing catalyst based on formic acid production, stability, and Faradaic efficiency, was immobilized on carbon electrodes, and tested inside a flow through reactor. After lab-scale testing was completed, the experimental data was used to perform a Life-Cycle Analysis (LCA) and conduct an Initial Technical and Economic Feasibility Study. The LCA showed a pathway to a net negative CO2 utilization process with the incorporation of renewable energy, while the TEA showed the potential to produce formic acid below the current commercial price. The UK EBOCU process was successfully demonstrated at the TRL3 level and has a clear pathway to further development and contribution to the nation’s ambitious decarbonization goals.

20 FOSSIL-FUELED POWER PLANTS↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence P - Raw Data

Sequence P: Wake Flow Visualization, Upwind (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 15 m/s. Yaw angles of 0° to –60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The aluminum blade tip designed to contain a smoke generator was installed, and counterweights were installed in the non-instrumented blade tip to compensate. The turbine was positioned at the appropriate yaw angle, and the smoke generator was ignited remotely. The campaign duration was 3 minutes for all tests except P1000000, which was 2 minutes. The file name convention was the standard format except for P10000A0, which indicated a 3° pitch angle. File P1000000 used a 12° pitch angle. After these two campaigns were collected, it was determined that all subsequent data should be collected with a 3° pitch angle. Pressure data were not acquired during this sequence, so all associated data values were flagged as not applicable by setting the measured values in the data file to 0.000 Pa. Corresponding pressure data are available from Sequence H for the 3° pitch angle test points. Flow visualization data obtained from wall- and ceiling-mounted video cameras were recorded to videotape. The camera locations and calibration procedures are described in Appendix J.