Search NASA⌕ Search

SEARCH · Search NASA

Results for “fracture monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

150 records · Page 9

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗

Advanced imaging of the macrostructure and microstructure of bone

Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Musculoskeletal↗

Improving Adhesive Bondline Time of Flight Predictions During Autoclave Cure Utilizing Machine Learning

Composite materials are increasingly being used in aerospace applications due to their superior strength-to-weight ratio compared to commonly used metals. A current limitation to widespread adoption is the certification of adhesively bonded joints. One approach to improving adhesive bonding in composites is accurately measuring the thickness of adhesive bondlines in composite laminates. Precise bondline thickness control is essential for aerospace applications where adhesive layer thickness directly affects joint fracture properties and structural performance. This study focused on implementing machine learning techniques to determine the ultrasonic time of flight (directly correlated to thickness) in adhesive bondlines throughout autoclave cure cycles. A high-temperature (use up to 180°C) ultrasonic scanning system was deployed in an autoclave to provide time of flight data through composite panels. Three experiments were conducted on the curing of 305 mm × 305 mm unidirectional composite panels. In the first experiment, a piecewise function was fit for the temperature correction factor to account for changing autoclave temperatures. Due to deficiencies in the first calibration experiment, a second experiment was run, and the results were used to train a machine learning model. The revised experiment, in combination with the machine learning model, significantly increased the accuracy of the bondline time of flight predictions (~14% error reduced to <1%). Data was processed using the Regression Learner Application in MATLAB®, with a Support Vector Machine selected for the model. The result was a machine learning algorithm capable of reliably quantifying ultrasonic time of flight through adhesive bondlines. The third experiment provided independent test data for the machine learning model, demonstrating that the model produces accurate predictions from data beyond its training set.

Machine Learning↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗