Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effect of pictorial display configuration on the frequency of control reversals during aircraft landing approaches

A fixed-base simulator study to determine the effect of increased pictorial display realism on the frequency of control reversals made with an inside-out landing display was conducted. Display conditions included the effects of collimation and scale (head-up versus head-down presentation), horizon symbology (simple line versus white-black sky-ground surfaces), and ground plane realism (computer generated perspective versus a TV picture of a realistic model). The number of control reversals was moderately high on all displays. Control reversals to roll disturbances occurred nearly twice as frequently as reversals to either pitch or lateral rate disturbances. Though there were no significant differences among the numbers of small control reversals for the different displays, there was some evidence that this conclusion may not apply to large control reversals.

Lincoln, R.↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stability-Constrained Learning for Frequency Regulation in Power Grids With Variable Inertia

The increasing penetration of converter-based renewable generation has resulted in faster frequency dynamics, and low and variable inertia. As a result, there is a need for frequency control methods that are able to stabilize a disturbance in the power system at timescales comparable to the fast converter dynamics. This paper proposes a combined linear and neural network controller for inverter-based primary frequency control that is stable at time-varying levels of inertia. We model the time-variance in inertia via a switched affine hybrid system model. We derive stability certificates for the proposed controller via a quadratic candidate Lyapunov function. We test the proposed control on a 12-bus 3-area test network, and compare its performance with a base case linear controller, optimized linear controller, and finite-horizon Linear Quadratic Regulator (LQR). Our proposed controller achieves faster mean settling time and over 50% reduction in average control cost across 100 inertia scenarios compared to the optimized linear controller. Unlike LQR which requires complete knowledge of the inertia trajectories and system dynamics over the entire control time horizon, our proposed controller is real-time tractable, and achieves comparable performance to LQR.

data-driven control↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optical Injection Locking of a VCSEL in an OEO

Optical injection locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface- emitting laser (VCSEL) that is an active element in the frequency-control loop of an opto-electronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency resonance. This particular optical-injection- locking scheme is expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. Inasmuch as the microwave power circulating in the frequency-control loop is a dynamic frequency-control variable (and, hence, cannot be stabilized), there arises a need for another means of stabilizing the wavelength. The present optical-injection-locking scheme satisfies the need for a means to stabilize the wavelength against microwave- power fluctuations. It is also expected to afford stabilization against temperature and current fluctuations. In an experiment performed to demonstrate this scheme, wavelength locking was observed when about 200 W of the output power of a commercial tunable diode laser was injected into a commercial VCSEL, designed to operate in the wavelength range of 795+/-3 nm, that was generating about 200 microW of optical power. (The use of relatively high injection power levels is a usual practice in injection locking of VCSELs.)

Strekalov, Dmitry↗

Separation of Frequency and Amplitude Modulation Contributions Due to External Vibration on a SAW Resonator

Surface SAW resonators (SAWR) are widely used in radio-frequency (RF) communications, frequency-control, and sensing applications. External vibration-induced modulations of a SAWR’s RF response can be detrimental in communications and frequency-control as it generates undesired spurious signals and unwanted phase noise. In sensing applications, vibration-induced response can either be a primary measurand or an undesired spurious signal that reduces sensor accuracy and precision. Therefore, characterization of vibration-induced modulations is important to improve device performance in all the applications listed above. This paper presents an in-phase and quadrature signal analysis technique to demodulate a SAWR RF signal exposed to external vibrations and separate the contributions of amplitude modulation (AM) and frequency modulation (FM). A SAWR was mounted in a cantilever configuration and exposed to external mechanical vibrating signals using a vibration generator. The SAWR was excited close to its resonant frequency using a RF synthesizer and its echo response was measured using a vector signal analyzer. The experimental results and findings reported in this paper confirm that the I-Q analysis developed in this work is effective not only to determine the frequency and spectral amplitude of a mechanical vibrating signal on a SAWR, but also to separate the AM and FM contributions. Here, this analysis contributes to the quantification and understanding of induced external vibrations on SAWRs used in contemporary communications, frequency control, and sensing applications.

42 ENGINEERING↗

On the application of a frequency domain controller design methodology to non-minimum phase and unstable systems

A frequency-domain design methodology was developed for controller synthesis maximizing the allowable size of an unknown-but-bounded disturbance while satisfying prespecified control and output constraints. The design technique, which accounts for bandwidth limitations, is based on mapping time-domain constraints into the frequency domain. Application of this technique to non-minimum-phase and/or unstable systems is presented. A non-minimum-phase, unstable SIMO (single-input/multiple-output) system is examined, and the results are compared to those obtained by the set-theoretic (ST) approach. The comparison shows that this methodology can yield controllers that reject step disturbances larger than those obtained by the ST method.

Sobhani, Massoud↗

FIND: A Synthetic weather generator to control drought Frequency, Intensity, and Duration

Water systems worldwide are experiencing climate change-induced shifts in drought properties like frequency, intensity, and duration, affecting water security and reliability. To develop and test effective drought preparedness plans, researchers often use synthetic weather generators to create hydrological scenarios that explore drought variability beyond historical records. Existing weather generators typically allow users to adjust streamflow statistics like percentiles or temporal correlation but do not directly control drought properties of frequency, intensity, and duration. To fill this gap, we propose FIND (Frequency, INtensity, and Duration) synthetic weather generator. FIND incorporates a standardized drought index to directly and in dependently control drought frequency, intensity, and duration in generated streamflow time series while preserving observed hydrological variability. Use cases for FIND include i) water systems analysis applications that seek to train and test drought strategies under historical and plausible future drought conditions, and ii) bottom-up vulnerability studies relating system vulnerability outcomes to specific changes in drought properties of frequency, intensity, and duration. Here, we demonstrate FIND’s versatility through three experiments: replicating historically observed drought properties, generating streamflow scenarios for multiple sites preserving correlation between their drought conditions, and generating a set of scenarios with direct and independent changes in drought properties. FIND source code is openly available for applications beyond the scope of this paper.

42 ENGINEERING↗

Multifrequency control pulses for multilevel superconducting quantum circuits

Superconducting quantum circuits, such as the superconducting phase qubit, have multiple quantum states that can interfere with ideal qubit operation. The use of multiple frequency control pulses, resonant with the energy differences of the multistate system, is theoretically explored. An analytical method to design such control pulses is developed, using a generalization of the Floquet method to multiple frequency controls. This method is applicable to optimizing the control of both superconducting qubits and qudits and is found to be in excellent agreement with time-dependent numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Smart Grid Asset Control Strategies for Providing Ancillary Services

With large-scale plans to integrate renewable generation driven mainly by state-level renewable portfolio requirements, more resources will be needed to compensate for the uncertainty and variability associated with intermittent generation resources. Distributed assets can be used to mitigate the concerns associated with renewable energy resources and to keep costs down. Under such conditions, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive but also technically difficult. It is therefore important to explore how a sufficient proportion of the loads could assume a routine role in primary frequency control to maintain the stability of the system at an acceptable cost. The main objective of this project is to develop a novel hierarchical distributed framework for frequency based load control. The framework involves two decision layers. The top decision layer determines the optimal gain for aggregated loads for each load bus. The gains are computed using decentralized robust control methods, and will be broadcast to the corresponding participating loads every control period. The second layer consists of a large number of heterogeneous devices, which switch probabilistically during contingencies so that aggregated power change matches the desired amount according to the most recently received gains. The simulation results show great potential to enable systematic design of demand-side primary frequency control with stability guarantees on the overall power system. The proposed design systematically accounts for the interactions between the total load response and bulk power system frequency dynamics. It also guarantees frequency stability under a wide range of time varying operating conditions. The local device-level load response rules fully respect the device constraints (such as temperature setpoint, compressor time delays of HVACs, or arrival and departure of the deferrable loads), which are crucial for implementing real load control programs. The promise of autonomous, Grid Friendly™ response by smart appliances in the form of under-frequency load shedding was demonstrated in the GridWise Olympic Peninsula Demonstration in 2006. Each controller monitored the power grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances responded reliably to each shallow under-frequency event, which was an average of one event per day and shed their loads for the durations of these events. Another objective of this project was to perform extensive simulation studies to investigate the impact of a population of Grid Friendly™ Appliances (GFAs) on the bulk power system frequency stability. The GFAs considered in this report are represented as demonstration units with water heaters individually modeled.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A single-photon polarization-frequency controlled-NOT gate

We develop a high-fidelity controlled-NOT gate between photonic polarization and frequency, leveraging direction-dependent electro-optic phase modulation in a fiber Sagnac loop. This design could facilitate massively parallelizable entanglement distillation with polarization-frequency resources in lightwave networks.

Lu, Hsuan-Hao [ORNL] (ORCID:0000000340090787)↗

Microwave Radar Sensor Modules

Systems and methods for detecting biometrics using microwave radar sensor modules are disclosed. Integrated microwave sensor modules can include a transmitter unit configured to generate at least one continuous wave transmit signal based upon at least one frequency control signal, a receiver unit configured to utilize a cancellation path to cancel contributions to a return signal based upon at least one cancellation path control signal, and a microcontroller unit that includes a processor, a memory containing a microcontroller application, where the microcontroller application configures the processor to generate at least one frequency control signal to generate least one CW transmit signal having a plurality of frequencies, generate at least one cancellation path control signal to automatically adjust the cancellation path in real time, receive at least one demodulated signal, digitize the at least one demodulated signal, and update the at least one frequency control and cancellation path control signals.

Lux, James Paul↗

Fundamental Frequency Switching Control of Seven-Level Hybrid Cascaded H-bridge Multilevel Inverter

This paper presents a cascaded H-bridge multilevel inverter that can be implemented using only a single dc power source and capacitors. Standard cascaded multilevel inverters require n dc sources for 2n + 1 levels. Without requiring transformers, the scheme proposed here allows the use of a single dc power source (e.g., a battery or a fuel cell stack) with the remaining n-1 dc sources being capacitors, which is referred to as hybrid cascaded H-bridge multilevel inverter (HCMLI) in this paper. It is shown that the inverter can simultaneously maintain the dc voltage level of the capacitors and choose a fundamental frequency switching pattern to produce a nearly sinusoidal output. HCMLI using only a single dc source for each phase is promising for high-power motor drive applications as it significantly decreases the number of required dc power supplies, provides high-quality output power due to its high number of output levels, and results in high conversion efficiency and low thermal stress as it uses a fundamental frequency switching scheme. This paper mainly discusses control of seven-level HCMLI with fundamental frequency switching control and how its modulation index range can be extended using triplen harmonic compensation.

30 DIRECT ENERGY CONVERSION↗

Supercapacitor to Provide Ancillary Services With Control Coordination

This paper proposes a dynamic frequency support scheme of a supercapacitor energy storage system (SCESS) in coordination with run-of-the-river-based pumped storage hydropower (PSH) to enhance the short-term frequency stability in a power system that has a high penetration of renewable energy. To achieve this, the proposed coordinated frequency controller (CFC) enables the SCESS and PSH plant to provide the frequency response. The CFC scheme employs a dynamic droop characteristic in parallel with an integral controller and a distribution function. The dynamic droop characteristic determines the power production for frequency regulation employing a variable gain, which varies with the total capacity of the frequency control units and magnitude of the system frequency error with time; the gain increases with the frequency error, and thereby, arresting the frequency nadir at a higher level than in the conventional droop characteristic. In addition, the distribution function dispatches the power from the dynamic droop and integral controller to the control units in proportion to their headrooms; furthermore, the distribution function considers a sudden loss of generation from an SCESS by its operational constraint during the frequency support. Thus, the proposed dynamic frequency support scheme can enhance the short-term frequency stability for a frequency event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic effects during the action of the pump noise on bistable self-modulation oscillations in a solid-state ring laser

Nonlinear radiation dynamics of a solid-state ring laser is studied in the region of laser parameters corresponding to the parametric resonance between the self-modulation and relaxation oscillations. Bistable regions are found in which, apart from the self-modulation regime of the first kind, a stable quasi-periodic self-modulation regime exists. Temporal and spectral emission parameters of counterpropagating waves are considered in the bistable self-modulation generation regimes. The effect of noise on the bistable self-modulation oscillations is studied. It is shown that during the interaction of noise, spectral peaks split at relaxation and self-modulation frequencies. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗