Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency scan testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

THREE-DIMENSIONAL STRUCTURE OF MICROWAVE SOURCES FROM SOLAR ROTATION STEREOSCOPY VERSUS MAGNETIC EXTRAPOLATIONS

We use rotation stereoscopy to estimate the height of a steady-state solar feature relative to the photosphere, based on its apparent motion in the image plane recorded over several days of observation. The stereoscopy algorithm is adapted to work with either one- or two-dimensional data (i.e., from images or from observations that record the projected position of the source along an arbitrary axis). The accuracy of the algorithm is tested on simulated data, and then the algorithm is used to estimate the coronal radio source heights associated with the active region NOAA 10956, based on multifrequency imaging data over seven days from the Siberian Solar Radio Telescope near 5.7 GHz, the Nobeyama Radio Heliograph at 17 GHz, as well as one-dimensional scans at multiple frequencies spanning the 5.98-15.95 GHz frequency range from the RATAN-600 instrument. The gyroresonance emission mechanism, which is sensitive to the coronal magnetic field strength, is applied to convert the estimated radio source heights at various frequencies, h(f), to information about magnetic field versus height B(h), and the results are compared to a magnetic field extrapolation derived from photospheric magnetic field observations obtained by Hinode and Michelson Doppler Imager. We found that the gyroresonant emission comes from heights exceeding the location of the third gyrolayer irrespective of the magnetic extrapolation method; implications of this finding for coronal magnetography and coronal plasma physics are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooperative Adsorption of Trehalose to DPPC Monolayers at the Water-Air Interface Studied with Vibrational Sum Frequency Generation

A combination of surface tension, surface-specific vibrational spectroscopy, and differential scanning calorimetry experiments were performed to examine the ability of lipid films to enrich interfacial organic content by attracting soluble, neutral saccharides from bulk aqueous solution. This “cooperative adsorption” hypothesis has been proposed as a possible source of the high organic fractions found in sea spray aerosols and is believed to be responsible for cryoprotection in some organisms. Experiments described in this work show that the neutral disaccharide trehalose (Tre) is drawn to lipid films comprised of dipalmitoylphosphatidylcholine (DPPC), a saturated lipid that is a major component of most eukaryotic cells. The effects of Tre on DPPC monolayer structure and organization were tested with tightly packed monolayers in the two-dimensional solid phase (40 Å2/molecule) and more expanded monolayers in the two dimensional liquid condensed phase (55 Å2/molecule). Surface tension data show that DPPC monolayer behaviour remains largely unchanged until Tre bulk concentrations are sufficiently high (= 50 mM). In contrast, surface specific vibrational sum frequency spectra show that when Tre bulk concentrations are = 10 mM, DPPC monolayers in their liquid condensed state (55 Å2/molecule) became more ordered, implying relatively strong noncovalent interactions between the two species. Tre also induces changes in DPPC bilayer behaviour as evidenced by a gel to liquid crystalline phase transition temperature that increases with increasing Tre concentration. This result suggests that Tre associates with the DPPC headgroups in very specific ways leading to partial dehydration. Together, these results support the cooperative adsorption mechanism under some circumstances, namely that there is a minimum aqueous phase Tre concentration required to induce observable structural changes in a lipid monolayer, and that these effects are most pronounced with DPPC monolayers in their liquid condensed state compared to a tightly packed 2-dimensional solid.

Link, Katie A.↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

Brillouin optical reflectometer with a Brillouin active filter

A new scheme of a fibre-optic Brillouin reflectometer is experimentally studied, in which the spectral line of spontaneous Brillouin scattering is selected by an active Brillouin filter represented by the tested fibre itself. To improve the reflectometer characteristics, a cyclic code and Raman amplification of the scattering signal are applied. With an averaging time of 5 min, scanning of 25 km of fibre with a spatial resolution of 4 m and a sampling resolution of 1 m are provided. The root-mean-square deviation in determining the Brillouin frequency is less than 1.1 MHz. The reflectometer sensitivity is evaluated with respect to the temperature changes and mechanical deformation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Submillimeter and Radio Astronomy Research and Analysis Program

This program entitled "Infrared Submillimeter and Radio Astronomy Research and Analysis Program" with NASA-Ames Research Center (ARC) was proposed by the Smithsonian Astrophysical Observatory (SAO) to cover three years. Due to funding constraints only the first year installment of $18,436 was funded, but this funding was spread out over two years to try to maximize the benefit to the program. During the tenure of this contact, the investigators at the SAO, Drs. Wesley A. Traub and Nathaniel P. Carleton, worked with the investigators at ARC, Drs. Jesse Bregman and Fred Wittebom, on the following three main areas: 1. Rapid scanning SAO and ARC collaborated on purchasing and constructing a Rapid Scan Platform for the delay arm of the Infrared-Optical Telescope Array (IOTA) interferometer on Mt. Hopkins, Arizona. The Rapid Scan Platform was tested and improved by the addition of stiffening plates which eliminated a very small but noticeable bending of the metal platform at the micro-meter level. 2. Star tracking Bregman and Wittebom conducted a study of the IOTA CCD-based star tracker system, by constructing a device to simulate star motion having a specified frequency and amplitude of motion, and by examining the response of the tracker to this simulated star input. 3. Fringe tracking. ARC, and in particular Dr. Robert Mah, developed a fringe-packet tracking algorithm, based on data that Bregman and Witteborn obtained on IOTA. The algorithm was tested in the laboratory at ARC, and found to work well for both strong and weak fringes.

Traub, Wesley A.↗

False-Positive Results and Incidental Findings with Annual CT or PET/CT Surveillance in Asymptomatic Patients with Resected Stage III Melanoma

Objective: The aim of this study was to quantify false-positive and incidental findings from annual surveillance imaging in asymptomatic, American Joint Committee on Cancer stage III melanoma patients. Methods: This was a cohort study of patients treated at Melanoma Institute Australia (2000–2015) with baseline computed tomography (CT) or positron emission tomography (PET)/CT imaging and at least two annual surveillance scans. False-positives were defined as findings suspicious for melanoma recurrence that were not melanoma, confirmed by histopathology, subsequent imaging, or clinical follow-up, while incidental findings were defined as non-melanoma-related findings requiring further action. Outcomes of incidental findings were classified as ‘benign’ if they resolved spontaneously or were not seriously harmful; ‘malignant’ if a second malignancy was identified; or ‘other’ if potentially harmful. Results: Among 154 patients, 1022 scans were performed (154 baseline staging, 868 surveillance) during a median follow-up of 85 months (interquartile range 56–112); 57 patients (37%) developed a recurrence. For baseline and surveillance imaging, 124 false-positive results and incidental findings were identified in 81 patients (53%). The frequency of these findings was 5–14% per year, and an additional 181 tests, procedures, and referrals were initiated to investigate these findings. The diagnosis was benign in 109 findings of 124 findings (88%). Fifteen patients with a benign finding underwent an unnecessary invasive procedure. Surveillance imaging identified distant metastases in 20 patients (13%). Conclusion: False-positive results and incidental findings occur in at least half of all patients undergoing annual surveillance imaging, and the additional healthcare use is substantial. These findings persist over time. Clinicians need to be aware of these risks and discuss them with patients, alongside the expected benefits of surveillance imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

fatigue testing machines↗

Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2 -treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however the accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2 O 5 , NbO and NbN (1-x) O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.

36 MATERIALS SCIENCE↗

An RF link analysis of MSBLS during ALT

An analysis of the microwave scanning beam landing system (MSBLS) ground station to orbiter radio frequency (RF) link was made to determine if the expected signal levels will be compatible with orbiter receiver capabilities. Of primary interest was whether or not loss of data will occur due to interference caused by the orbiter 101 nose boom which provides additional air data during the approach and landing test. The results of the analysis indicate that a small amount of data loss may occur due to the proximity of the MSBLS antennas and the nose boom. Tabulated data of antenna radiation patterns are given.

Speir, R. E.↗

High-frequency Electrocardiogram Analysis in the Ability to Predict Reversible Perfusion Defects during Adenosine Myocardial Perfusion Imaging

Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.

Tragardh, Elin↗

35-45 Giga Hertz Transceiver System for Phase and Magnitude Detection

Nondestructive evaluation (NDE) is the science and practice of examining an object in a way that the object's usefulness is not adversely affected. Different types of NDE methods exist but this thesis is based on microwave and millimeter wave NDE using imaging techniques. Microwave NDE is based on illuminating the object under test with a microwave signal and studying the various properties of the reflected signal from the object. This reflected signal contains some information about the inner structure of the object under test. This information may be contained in several parameters including the phase and magnitude of the reflected signal. The goal of this project is to design and build a Q-band coherent transceiver that is capable of measuring the reflected signal's phase and magnitude so that an image of the object under test may be reconstructed. From the several techniques that can be used to construct an image of the object under test, techniques of interest to this work include synthetic aperture focusing technique (SAFT) and microwave holography. The transceiver system should have the ability to sweep a large portion of Q-band frequency range in small frequency steps as quick as possible while the detected phase and magnitude of the reflected signal is very accurate. Several different designs were studied and the final schematic diagram of the transceiver system was determined. One of the most important modules that was designed, implemented and tested in the laboratory was an accurate phase/magnitude detector circuit. The compared results of the scans using the transceiver system and vector network analyzer (VNA) showed that this transceiver system has a great potential to replace a VNA for the purpose of microwave and millimeter wave imaging.

Beni, Aman Aflaki↗

Effect of Multi-Walled Carbon Nanotubes on Viscoelastic Properties of PP/Reed Flour Composites

The objective of this investigation was to evaluate the influence of multi-wall carbon nanotubes (MWCNTs) on the dynamic mechanical properties of polypropylene (PP)/reed flour (RF) composites. The experimental samples were prepared through the melt mixing of PP/RF at 50% weight ratios, with various amounts of MWCNTs (0, 1, 2, 3 and 5 phr) in a twin-screw extruder, then the samples made by injection molding. The amount of maleic anhydride grafted polypropylene (PP-g-MA) as a coupling agent was fixed at 2 phr for all formulations. Dynamic mechanical analysis (DMA) tests were carried out to investigate the viscoelastic behavior of nanocomposites. The dynamic mechanical properties such as storage modulus (Eʹ), loss modulus (Eʺ), and damping coefficient (tan δ) of nanocomposites were investigated in the temperature range of −80 to 160 °C at a step of 5 °C and frequency of 1 Hz. The morphology of the specimens was characterized using field emission scanning electron microscope (FE-SEM) technique. Results indicated that the storage modulus of samples was found to increase with incorporation of MWCNTs while damping properties registered a decrease, owing to the reinforcing effect of CNTs into the composites. Moreover, CNTs addition leads to a positive shift in glass transition temperature (T{sub g}), which is explained on the molecular mobility of the polymer chains behavior. Additionally, the minimum adhesion factor is related to samples containing 2 phr MWCNTs which provides the best interaction between polymer and fibers. FE-SEM micrographs showed a predominantly homogeneous CNTs distribution through the composites; however, some aggregates were observed at higher CNTs fractions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of bond line discontinuities in a high-Mn TWIP steel pipe welded by HF-ERW

In this work, the microstructure and defects in a high-frequency electrical resistance welded (HF-ERW) pipe of high-Mn twinning-induced plasticity (TWIP) steel were characterized. The microstructure of the base metal and the bond line were examined using both optical microscopy and scanning electron microscopy. The features of the bond line were similar to those of conventional steel. Simultaneously, the circumferential ductility was evaluated via a flaring test. It was concluded that the deterioration of the circumferential ductility in a high-Mn TWIP steel pipe was caused by irregular shaped oxide defects and a penetrator that had been formed during welding. Specifically, the penetrator, which is composed of MnO and Mn{sub 2}SiO{sub 4}, was found to be the most influential on the circumferential ductility of the welded pipe. The penetrator was analyzed using both an electron probe micro analyzer and transmission electron microscopy, and the formation sequence of the penetrator was evaluated. - Highlights: •This study focused on applying the HF-ERW process to the seam welding of expandable pipe using TWIP steels. •For improvement of the circumferential ductility, deterioration factors were characterized. •Penetrator which would mainly deteriorate the circumferential ductility consisted of round MnO and Mn{sub 2}SiO{sub 4}. •Metallurgical evidence of existing theory regarding the mechanism of defect formation during the HF-ERW was characterized.

36 MATERIALS SCIENCE↗

Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H{sub 2}O), glycerol (C{sub 3}H{sub 8}O{sub 3}) and diiodomethane (CH{sub 2}I{sub 2}) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase in surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

36 MATERIALS SCIENCE↗

Phase aligner for the Electronically Scanned Thinned Array Radiometer (ESTAR) instrument

A prototype Phase Aligner (PA) or the Electronically Scanned Thinned Array Radiometer instrument has been designed and tested. Implemented in a single Xilinx XC3042PC84-125 Field Programmable Gate Array (FPGA), it is a dual-port register file which allows independent storage and phase coherent retrieval of antenna array data by the Central Processing Unit (CPU). It has dimensions of 4 x 20 bits and can be used at clock frequencies as high as 25 MHz. The ESTAR is a passive synthetic-aperture radiometer designed to sense soil moisture and ocean salinity at L-band.

Chren, William A., Jr.↗

Delamination Detection Using Guided Wave Phased Arrays

This paper presents a method for detecting multiple delaminations in composite laminates using non-contact phased arrays. The phased arrays are implemented with a non-contact scanning laser Doppler vibrometer (SLDV). The array imaging algorithm is performed in the frequency domain where both the guided wave dispersion effect and direction dependent wave properties are considered. By using the non-contact SLDV array with a frequency domain imaging algorithm, an intensity image of the composite plate can be generated for delamination detection. For the proof of concept, a laboratory test is performed using a non-contact phased array to detect two delaminations (created through quasi-static impact test) at different locations in a composite plate. Using the non-contact phased array and frequency domain imaging, the two impact-induced delaminations are successfully detected. This study shows that the non-contact phased array method is a potentially effective method for rapid delamination inspection in large composite structures.

Tian, Zhenhua↗

Overview of the NASA SETI Program

The NASA Search of Extraterrestrial Intelligence (SETI) program plan is to scan the microwave window from 1 to 10 GHz with existing radio telescopes and sophisticated signal processing equipment looking for narrow band features that might represent artificial signals. A microwave spectrometer was built and is being field tested. A pattern recognition computer to search for drifting continuous wave signals and pulse trains in the output spectra is being designed. Equipment to characterize the radio frequency interference environment was also built. The plan is to complete the hardware and software by FY-88. Then, with increased funding, this equipment will be replicated in Very Large Scale Integration form. Observations, both a complete sky survey and a search fo nearby solar type stars, will begin in about 1990. The hypothesis that very powerful signals exist or that signals are being beamed at us will be tested. To detect the kinds of signals radiated at distances of 100 light years will require a collecting area kilometers in diameter.

Oliver, B. M.↗

Image feature extraction using Gabor-like transform

Noisy and highly textured images were operated on with a Gabor-like transform. The results were evaluated to see if useful features could be extracted using spatio-temporal operators. The use of spatio-temporal operators allows for extraction of features containing simultaneous frequency and orientation information. This method allows important features, both specific and generic, to be extracted from images. The transformation was applied to industrial inspection imagery, in particular, a NASA space shuttle main engine (SSME) system for offline health monitoring. Preliminary results are given and discussed. Edge features were extracted from one of the test images. Because of the highly textured surface (even after scan line smoothing and median filtering), the Laplacian edge operator yields many spurious edges.

Finegan, Michael K., Jr.↗