Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency scan testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-D-207-06: Clinical Validations of Shading Correction for Cone-Beam CT Using Planning CT as a Prior

Purpose: Current cone-beam CT (CBCT) images contain severe shading artifacts mainly due to scatter, hindering their quantitative use in current radiation therapy. We have previously proposed an effective shading correction method for CBCT using planning CT (pCT) as prior knowledge. In this work, we investigate the method robustness via statistical analyses on studies of a large patient group and compare the performance with that of a state-of-the-art method implemented on the current commercial radiation therapy machine -- the Varian Truebeam system. Methods: Since radiotherapy patients routinely undergo multiple-detector CT (MDCT) scans in the planning procedure, we use the high-quality pCT as “free” prior knowledge for CBCT image improvement. The CBCT image with no correction is first spatially registered with the pCT. Primary CBCT projections are estimated via forward projections of the registered image. The low frequency errors in the projections, which stem from mainly scatter, are estimated by filtering the difference between original line integral and the estimated scatter projections. The corrected CBCT image is then reconstructed from the scatter corrected projections. The proposed method is evaluated on 40 cancer patients. Results: On all patient images, we compare errors on CT number, spatial non-uniformity (SNU) and image contrast, using pCT as the ground truth. T-tests show that our algorithm improves over the Varian method on CBCT accuracies of CT number and SNU with 90% confident. The average CT number error is reduced from 54.8 HU on the Varian method to 40.9 HU, and the SNU error is reduced from 7.7% to 3.8%. There is no obvious improvement on image contrast. Conclusion: Large-group patient studies show that the proposed pCT-based algorithm outperforms the Varian method of the Truebeam system on CBCT shading correction, by providing CBCT images with higher CT number accuracy and greater image uniformity.

60 APPLIED LIFE SCIENCES↗

Morphological Degradation of Oxygen Evolution Reaction-Electrocatalyzing Nickel Selenides at Industrially Relevant Current Densities

We investigated electrodeposited nanoparticulate nickel selenide (pre)catalysts that transform into nickel oxides/ oxyhydroxides under oxygen evolution reaction conditions in alkaline solutions. Previous studies of this transformation were conducted at lower current densities than those of industrial relevance (≥1 A cm −2 ). We used ultramicroelectrodes (UMEs) to achieve such current densities, benefiting from their small size, ensuring low absolute currents and low ohmic drop but high current densities. Morphological degradation of the catalyst material was only observed at current densities exceeding 1 A cm −2 but not for smaller ones. Using X-ray absorption, Xray photoemission spectroscopy, and X-ray diffraction, we confirmed that the degradation was accompanied by the literature-known transformation of nanoparticulate Ni 3 Se 2 (bulk)/NiSe (surface) into nickel oxyhydroxide. The transformation of the precatalyst goes along with a significant improvement in the charge transfer kinetics observed by decreasing Tafel slopes with ongoing experimental time extracted from cyclic voltammetry (CV) experiments and electrochemical impedance spectroscopy (EIS) in the high-frequency range. However, these kinetic improvements are accompanied by limitations in mass transport concluded from decreasing current responses at high overpotentials in CVs and increasing impedance in the low-frequency range of the EIS spectra after extended CV cycling. These mass transport limitations originated from morphological degradations at the UME exceeding 1 A cm −2 which we proved by applying identical location scanning electron microscopy. This has not been reported in studies that have been limited to lower current densities before. Our findings showcase how UMEs can be used to study (pre)catalysts (herein nickel selenides) under current densities of industrial relevance in the absence of ohmic drop-related ambiguities, combined with in-depth materials characterization studies, e.g., identical location microscopy and advanced spectroscopic methods. This approach enables direct evaluation and comparison of catalyst materials and thus demonstrates how to overcome long-standing limitations of electrocatalyst design and testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Study on Heat Transfer and Pressure Drop of In-House Synthesized Graphene Oxide Nanofluids

In this work, first, graphene oxide nanosheets were synthesized in-house according to the modified Hummers method, and these nanosheets were used to prepare graphene oxide nanofluids at two concentrations. Then the thermo-physical properties of nanofluids characterized using X-ray diffraction analysis, a scanning electron microscope, and UV-Vis spectrophotometry. The particle size distribution was investigated using dynamic light scattering. Then, a fundamental study was conducted on the thermal-hydraulic characteristics of graphene oxide nanofluids flowing through a straight copper tube. An experimental setup was developed to find the heat transfer characteristics and pressure drop of nanofluids in the test section consisting of a copper tube with constant heat flux. The flow regimes and associated pressure drop and heat transfer characteristics at varying flow rate were investigated at three different heat flux conditions of 7.4, 9.1, and 12.6 kW/m 2 . Due to the increase in viscosity, flowrate and Reynolds number decreased from 0.01 wt.% to 0.1 wt.% of graphene oxide nanofluids at constant pump frequency. Experimental data obtained for water was validated with the findings from the literature, and the correlations were formulated for the Nusselt number and Reynolds number by considering the multiple regression analysis. The convective heat transfer coefficient for graphene oxide at 0.01 wt.% was higher when compared to graphene oxide at 0.1 wt.% and water. Finally, the variation of Nusselt number with the heat flux and velocity was insignificant.

36 MATERIALS SCIENCE↗

Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C{sup 4+} ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8–10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C{sup 4+}, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

07 ISOTOPE AND RADIATION SOURCES↗

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens↗

Automated flaw detection scheme for cast austenitic stainless steel weld specimens using Hilbert-Huang transform of ultrasonic phased array data

The objective of this work is to develop processing algorithms to detect and localize flaws using ultrasonic phased-array data. Data was collected on cast austenitic stainless stell (CASS) weld specimens onloan from the U.S. nuclear power industry' Pressurized Walter Reactor Owners Group (PWROG) traveling specimen set. Each specimen consists of a centrifugally cast stainless stell (CCSS) pipe section welded to a statically cst(SCSS) or wrought (WRSS) section. The paper presents a novel automated flaw detection and localization scheme using low frequency ultrasonic phased array inspection singals from the weld and heat affected zone of the based materials. The major steps of the overall scheme are preprocessing and region of interest (ROI) detection followed by the Hilbert-Huang transform (HHT) of A-scans in the detected ROIs. HHT offers time-frequency-energy distribution for each ROI. The Accumulation of energy in a particular frequency band is used as a classification feature for the particular ROI.

36 MATERIALS SCIENCE↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

NEAR-FIELD CHARACTERIZATION OF RECONFIGURABLE NARROWBAND ANTENNA IN THE PROXIMITY OF THE HUMAN BODY

Reconfigurable antennas have been suggested recently for use in various mobile systems. These systems are usually operated in the vicinity of human body, leading to mutual interaction with body tissues. A nondestructive evaluation method is developed to characterize a reconfigurable antenna designed to cover the GSM-900/DCS-1800 bands. Modeling based on FDTD is performed of the antenna in free space and in proximity to the human head. Results reveal frequency shift, and variations in the matching and bandwidth, depending on antenna orientation with respect to the head. Experimental setup is also used to characterize the SAR values in human head. A six-degree-of-freedom robot is implemented to scan a head phantom using specialized sensors and head simulating liquids. The developed system provides a tool for guiding the design of the new category of reconfigurable antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Optimization for Nonrigid Nano-Tomography

Resolution level and reconstruction quality in nano-computed tomography (nano-CT) are in part limited by the stability of microscopes, because the magnitude of mechanical vibrations during scanning becomes comparable to the imaging resolution, and the ability of the samples to resist radiation induced deformations during data acquisition. In such cases, there is no incentive in recovering the sample state at different time steps like in time-resolved reconstruction methods, but instead the goal is to retrieve a single reconstruction at the highest possible spatial resolution and without any imaging artifacts. Here we propose a distributed optimization solver for tomographic imaging of samples at the nanoscale. Our approach solves the tomography problem jointly with projection data alignment, nonrigid sample deformation correction, and regularization. Projection data consistency is regulated by dense optical flow estimated by Farneback's algorithm, leading to sharp sample reconstructions with less artifacts. Synthetic data tests show robustness of the method to Poisson and low-frequency background noise. We accelerated the solver on multi-GPU systems and validated the method on three nano-imaging experimental data sets.

97 MATHEMATICS AND COMPUTING↗

SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.

60 APPLIED LIFE SCIENCES↗

Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

42 ENGINEERING↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

99 GENERAL AND MISCELLANEOUS↗

Detection of defects buried in metallic samples by scanning microwave microscopy

This paper reports the local detection of buried calibrated metal defects in metal samples by a new experimental technique, scanning microwave microscopy. This technique combines the electromagnetic measurement capabilities of a microwave vector network analyzer with the subnanometer-resolution capabilities of an atomic force microscope. The network analyzer authorizes the use of several frequencies in the range 1-6 GHz, allowing three-dimensional tomographical investigation, which is useful for the detection of bulk defects in metal materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Portable Vibro-acoustic Testing System for In Situ Microstructure Characterization and Metrology

Portable Vibro-acoustic Testing System for In situ Microstructure Characterization and Metrology James A. Smith, Corrie I. Nichol Idaho National Laboratory, Idaho Falls ID Mostafa Fatemi, Mayo Clinic, Rochester MN There is a need in research reactors like the INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by INL [1] for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA is a three-dimensional (3D) imaging modality based on ultrasound-stimulated acoustic emission. VA uses the force caused by the beating of two frequencies to generate an acoustic emission signal. Due to absorption or reflection, the energy density in the object at an acoustic focal point changes to produce a “radiation force.” This force locally vibrates the object, which results in an acoustic field that depends on the characteristics of the object at that point. This acoustic field is detected for every point in the object; the resulting data is used to make an image of the object’s mechanical properties. This technology is fundamentally different from traditional ultrasound imaging. More specifically, VA is: (a) based on the “radiation force,” a nonlinear phenomenon in sound propagation, and (b) sensitive to both high and low frequency dynamic responses of the object. The combination of these two response types provides information about characteristics of the object beyond what is possible by traditional ultrasound imaging. High spatial resolution is achieved, since the radiation force is localized to the focal point of the ultrasound beam. Low-frequency information, which is a representative of structural characteristics, is gained through the radiation force mechanism at a low (beat) frequency. This paper will report on the development of a portable scanning that can be set up to characterize materials and component in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discus the design of the portable system. 1. Smith, J. A., and Kunerth, D. C., “Vibro-acoustic Sensors for Materials Characterization and Related Methods and Systems,” Patent Application 13226280, 09/06/2011.

36 MATERIALS SCIENCE↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

Scanning tunneling shot-noise spectroscopy in Kondo systems

Using a large- N theory in combination with the Keldysh nonequilibrium Green's function formalism, we investigate the current, differential conductance, zero-frequency shot noise, and Fano factor as measured by scanning tunneling shot-noise spectroscopy (STSNS) using a scanning tunneling microscope (STM) near single Kondo impurities and in Kondo lattices. We show that the Fano factor F exhibits a characteristic bias dependence arising from Kondo screening that is similar to the Kondo resonance observed in the differential conductance. Moreover, the line shape of F is strongly dependent on the ratio of the tunneling amplitudes for electron tunneling from the STM tip into the conduction band and electronic levels of the magnetic adatoms. We demonstrate that the Fano factor can be enhanced or suppressed due to interference effects and as such, is not only a sensitive probe for the correlation effects arising from Kondo screening, but also for quantum interference between tunneling electrons. We identify a correlation between the form of the differential conductance and the Fano factor that could be tested in future STSNS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature mechanical properties of superconducting radio frequency cavity materials

Low temperature mechanical behaviors have been investigated for the constituent materials of superconducting radio frequency cavities. Test materials consist of small grain Nb, single crystal Nb, large grain Nb (bicrystal), Ti45Nb-Nb weld joint (e-beam welded), and Ti-316L bimetal joint (explosion welded). The strength of all test metals displayed strong temperature dependence and the Ti-316L bimetal showed the highest strength and lowest ductility among the test materials. The fracture toughness of the small grain Nb metals decreased with decreasing test temperature and reached the lower shelf values (30 40 MPa m) at or above 173 K. The Ti45Nb base and Ti45Nb-Nb weld metals showed much higher fracture toughness than the small grain Nb. An extrapolation and comparison with existing data showed that the fracture toughness of the small grain Nb metals at 4 K was expected to be similar to those at 173 K and 77 K. The results from optical photography at a low magnification and fractography by a scanning electron microscope were consistent with corresponding mechanical properties.

36 MATERIALS SCIENCE↗