Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Long-distance contribution to {Delta}{Gamma}{sub s} of the B{sub s}-B{sub s} system

We estimate the long-distance contribution to the width difference of the B{sub s}-B{sub s} system, based mainly on two-body D{sub s}{sup (*)}D{sub s}{sup (*)} modes and three-body D{sub s}{sup (*)}D{sup (*)}K{sup (*)} modes (and their CP conjugates). Some higher cs resonances are also considered. The contribution to {Delta}{Gamma}{sub s}/{Gamma}{sub s} by two-body modes is (10.2{+-}3.0)%, slightly smaller than the short-distance result of (13.3{+-}3.2)%. The contribution to {Delta}{Gamma}{sub s}/{Gamma}{sub s} by D{sub s0}*(2317), D{sub s1}(2460), and D{sub s1}(2536) resonances is negligible. For the three-body D{sub s}{sup (*)}D{sup (*)}K{sup (*)} modes, we adopt the factorization formalism and model the form factors with off-shell D{sub s}{sup (*)} poles, the D{sub sJ}(2700) resonance, and nonresonant contributions. These three-body modes can arise through current-produced or transition diagrams, but only SU(3)-related D{sub u,d}{sup (*)}D{sup (*)}K modes from the current diagram have been measured so far. The pole model results for D{sub u,d}*D{sup (*)}K agree well with the data, while D{sub u,d}D{sup (*)}K rates agree with the data only within a factor of 2 to 3. All measured D{sub u,d}{sup (*)}D{sup (*)}K rates can be reproduced by including nonresonant contributions. The total {Delta}{Gamma}{sub s}/{Gamma}{sub s} obtained is (16.7{+-}8.5)%, which agrees with the short-distance result within uncertainties. For illustration, we also demonstrate the effect of D{sub sJ}(2700) in modes with D{sup (*)}K{sup *}. In all scenarios, the total {Delta}{Gamma}{sub s}/{Gamma}{sub s} remain consistent with the short-distance result. Our results indicate that (a) the operator product expansion in the short-distance picture is a valid assumption, (b) approximating the B{sub s}{yields}D{sub s}{sup (*)}D{sub s}{sup (*)} decays to saturate {Delta}{Gamma}{sub s} has a large correction, (c) the effect of three-body modes cannot be neglected, and (d) in addition to the D{sub s} and D{sub s}* poles, the D{sub sJ}(2700) resonance also plays an important role in three-body modes. Future experiments are necessary to improve the estimation of {Delta}{Gamma}{sub s} from the long-distance point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE STRUCTURE AND SPECTRAL FEATURES OF A THIN DISK AND EVAPORATION-FED CORONA IN HIGH-LUMINOSITY ACTIVE GALACTIC NUCLEI

We investigate the accretion process in high-luminosity active galactic nuclei (HLAGNs) in the scenario of the disk evaporation model. Based on this model, the thin disk can extend down to the innermost stable circular orbit (ISCO) at accretion rates higher than 0.02 M-dot{sub Edd} while the corona is weak since part of the coronal gas is cooled by strong inverse Compton scattering of the disk photons. This implies that the corona cannot produce as strong X-ray radiation as observed in HLAGNs with large Eddington ratio. In addition to the viscous heating, other heating to the corona is necessary to interpret HLAGN. In this paper, we assume that a part of accretion energy released in the disk is transported into the corona, heating up the electrons, and is thereby radiated away. For the first time, we compute the corona structure with additional heating, fully taking into account the mass supply to the corona, and find that the corona could indeed survive at higher accretion rates and that its radiation power increases. The spectra composed of bremsstrahlung and Compton radiation are also calculated. Our calculations show that the Compton-dominated spectrum becomes harder with the increase of energy fraction (f) liberating in the corona, and the photon index for hard X-ray (2-10 keV) is 2.2 < {Gamma} < 2.7. We discuss possible heating mechanisms for the corona. Combining the energy fraction transported to the corona with the accretion rate by magnetic heating, we find that the hard X-ray spectrum becomes steeper at a larger accretion rate and the bolometric correction factor (L{sub bol}/L{sub 2-10keV}) increases with increasing accretion rate for f < 8/35, which is roughly consistent with the observational results.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherent to incoherent cross section ratio for 59.54 keV gamma rays at scattering angle of 110°

The coherent (Rayleigh) to incoherent (Compton) scattering cross-section ratio of elements, in the range 13 ≤ Z ≤ 82, are determined experimentally for 59.54 keV incident gamma photons. An HPGe (High purity germanium) semiconductor detector is employed, at scattering angle of 110°, to record the spectra originating from interactions of incident gamma photons with the target under investigation. The intensity ratio of Rayleigh to Compton scattered peaks observed in the recorded spectra, and corrected for photo-peak efficiency of gamma detector and absorption of photons in the target and air, along with the other required parameters provides the differential cross-section ratio. The measured values of cross-section ratio are found to agree with theoretical predictions based upon non-relativistic form factor, relativistic form factor, modified form factor and S-matrix theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emergency Control Aircraft System Using Thrust Modulation

A digital longitudinal Aircraft Propulsion Control (APC system of a multiengine aircraft is provided by engine thrust modulation in response to comparing an input flightpath angle signal (gamma)c from a pilot thumbwheel. or an ILS system with a sensed flightpath angle y to produce an error signal (gamma)e that is then integrated (with reasonable limits) to generate a drift correction signal to be added to the error signal (gamma)e after first subtracting a lowpass filtered velocity signal Vel(sub f) for phugoid damping. The output error signal is multiplied by a constant to produce an aircraft thrust control signal ATC of suitable amplitude to drive a throttle servo for all engines. each of which includes its own full-authority digital engine control (FADEC) computer. An alternative APC system omits sensed flightpath angle feedback and instead controls the flightpath angle by feedback of the lowpass filtered velocity signal Vel(sub f) which also inherently provides phugoid damping. The feature of drift compensation is retained.

Burken, John J.↗

IMAGING REDSHIFT ESTIMATES FOR BL LACERTAE OBJECTS

We have obtained high dynamic range, good natural seeing i' images of BL Lacertae objects (BL Lacs) to search for the active galactic nucleus host and thus constrain the source redshift. These objects are drawn from a sample of bright flat-spectrum radio sources that are either known (via recent Fermi Large Area Telescope observations) gamma-ray emitters or similar sources that might be detected in continuing gamma-ray observations. All had spectroscopic confirmation as BL Lac sources, but no redshift solution. We detected hosts for 25/49 objects. As these galaxies have been argued to be standard candles, our measured host magnitudes provide redshift estimates (ranging from 0.2 to 1.0). Lower bounds are established on the redshifts of non-detections. The mean of the fit redshifts (and lower limits) is higher than those of spectroscopic solutions in the radio-loud and gamma-ray-loud parent samples, suggesting corrections may be needed for the luminosity function and evolution of these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams

Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuously taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Activated Au foils by 2{pi}{beta}+2{pi}{beta}-{gamma} Coincidence Counting and EGS5 Monte Carlo Calculation

Neutron activation analysis using Au foil is a common and important method for measurement of thermal neutron fluence. To determine the activity of Au foil experimentally, Kawada et al. proposed 2{pi}{beta}+2{pi}{beta}-{gamma} coincidence counting. This method is based on 4{pi}{beta}-{gamma} coincidence counting but a 4{pi}{beta} detector is divided into two 2{pi}{beta} detectors those are independently operated in the method. In this research the correction factors in 2{pi}{beta}+2{pi}{beta}-{gamma} coincidence counting were obtained by measurement and simulation. The activities obtained by these correction factors were in good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X(3872) in Effective Field Theory

If the X(3872) resonance is a shallow boundstate of a the charm mesons D{sup 0}D-bar*{sup 0} and D*{sup 0}D-bar{sup 0}, it can be described by an effective theory of nonrelativistic D mesons coupled to nonrelativistic pions (X-EFT). In this talk, I give a brief overview of the X(3872), followed by a short review of X-EFT. I end my talk with results from calculations of the the next-to-leading-order correction to the partial decay width {gamma}[X{yields}D{sup 0}D-bar{sup 0}{pi}{sup 0}], and the decay of X(3872) to P-wave quarkonia.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zγ production at NNLO including anomalous couplings

In this paper we present a next-to-next-to-leading order (NNLO) QCD calculation of the processes $pp\rightarrow l^+l^-\gamma$ and $pp\rightarrow \nu\bar\nu\gamma$ that we have implemented in MCFM. Our calculation includes QCD corrections at NNLO both for the Standard Model (SM) and additionally in the presence of $Z\gamma\gamma$ and $ZZ\gamma$ anomalous couplings. We compare our implementation, obtained using the jettiness slicing approach, with a previous SM calculation and find broad agreement. Focusing on the sensitivity of our results to the slicing parameter, we show that using our setup we are able to compute NNLO cross sections with numerical uncertainties of about $0.1\%$, which is small compared to residual scale uncertainties of a few percent. We study potential improvements using two different jettiness definitions and the inclusion of power corrections. At $\sqrt{s}=13$ TeV we present phenomenological results and consider $Z\gamma$ as a background to $H\to Z\gamma$ production. Here, we find that, with typical cuts, the inclusion of NNLO corrections represents a small effect and loosens the extraction of limits on anomalous couplings by about $10\%$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The beam filling error in the Nimbus 5 electronically scanning microwave radiometer observations of Global Atlantic Tropical Experiment rainfall

A comparison of rain rates retrieved from the Nimbus 5 electronically scanning microwave radiometer brightness temperatures and observed from shipboard radars during the Global Atlantic Tropical Experiment (GATE) phase I shows that the beam filling error is the major source of discrepancy between the two. When averaged over a large scene (the GATE radar array, 400 km in diameter), the beam filling error is quite stable, being 50 percent of the observed rain rate. This suggests the simple procedure of multiplying retrieved rain rates by 2 (correction factor). A statistical model of the beam filling error is developed by envisioning an idealized instrument field-of-view that encompasses an entire gamma distribution of rain rates. A modeled correction factor near 2 is found for rain rate and temperature characteristics consistent with GATE conditions. The statistical model also suggests that the correction factor varies from 1.5 to 2.5 for suppressed to enhanced tropical convective regimes, and decreases to 1.5 as the freezing level and average depth of the rain column decreases to 2.5 km.

Short, David A.↗

Extending Fermi -LAT and H.E.S.S. limits on gamma-ray lines from dark matter annihilation

Gamma-ray lines from dark matter annihilation (χχ → γX, where X = γ, h, Z) are always accompanied, at lower energies, by a continuum gamma-ray spectrum stemming both from radiative corrections (X = γ) and from the decay debris of the second particle possibly present in the final state (X = h, Z). This model-independent gamma-ray emission can be exploited to derive novel limits on gamma-ray lines that do not rely on the line feature. Although such limits are not expected to be as stringent as those based on the line feature, they can be used to probe the existence of gamma-ray lines for dark matter masses beyond the largest energies accessible to current telescopes. In this report we use continuous gamma-ray searches from Fermi-LAT observations of Milky Way dwarf spheroidal galaxies and from H.E.S.S. observations of the Galactic halo to extend the limits on the annihilation cross-sections into monochromatic photons to dark matter masses well beyond 500 GeV (Fermi-LAT) and 20 TeV (H.E.S.S.). In this large-mass regime, our results provide the first constraints on gamma-ray lines from dark matter annihilation.

79 ASTRONOMY AND ASTROPHYSICS↗

Coulomb excitation of {sub 28}{sup 68}Ni{sub 40} at 'safe' energies

The B(E2;0{sup +}{yields}2{sup +}) value in {sup 68}Ni has been measured using Coulomb excitation at safe energies. The {sup 68}Ni radioactive beam was postaccelerated at the CERN on-line isotope mass separator (ISOLDE) facility to 2.9 MeV/u and directed to a {sup 108}Pd target. The emitted {gamma} rays were detected by the MINIBALL detector array. Not only directly registered but also indirectly deduced information on the nucleus emitting the {gamma} ray was used to perform the Doppler correction, leading to a larger center-of-mass angular range to infer the excitation cross section. The obtained value of 2.8{sub -1.0}{sup +1.2}x10{sup 2}e{sup 2} fm{sup 4} is in good agreement with the value measured at intermediate energy Coulomb excitation, confirming the low 0{sup +}{yields}2{sup +} transition probability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First cosmology results using type Ia supernovae from the Dark Energy Survey: the effect of host galaxy properties on supernova luminosity

ABSTRACT We present improved photometric measurements for the host galaxies of 206 spectroscopically confirmed type Ia supernovae discovered by the Dark Energy Survey Supernova Program (DES-SN) and used in the first DES-SN cosmological analysis. For the DES-SN sample, when considering a 5D (z, x1, c, α, β) bias correction, we find evidence of a Hubble residual ‘mass step’, where SNe Ia in high-mass galaxies (>1010M⊙) are intrinsically more luminous (after correction) than their low-mass counterparts by $\gamma =0.040\pm 0.019$ mag. This value is larger by 0.031 mag than the value found in the first DES-SN cosmological analysis. This difference is due to a combination of updated photometric measurements and improved star formation histories and is not from host-galaxy misidentification. When using a 1D (redshift-only) bias correction the inferred mass step is larger, with $\gamma =0.066\pm 0.020$ mag. The 1D−5D γ difference for DES-SN is $0.026\pm 0.009$ mag. We show that this difference is due to a strong correlation between host galaxy stellar mass and the x1 component of the 5D distance-bias correction. Including an intrinsic correlation between the observed properties of SNe Ia, stretch and colour, and stellar mass in simulated SN Ia samples, we show that a 5D fit recovers γ with −9 mmag bias compared to a +2 mmag bias for a 1D fit. This difference can explain part of the discrepancy seen in the data. Improvements in modelling correlations between galaxy properties and SN is necessary to ensure unbiased precision estimates of the dark energy equation of state as we enter the era of LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of &#x3C7; c 1 and &#x3C7; c 2 production with s = 7 TeV p p collisions at ATLAS

CERN-LHC. The prompt and non-prompt production cross-sections for the chi_c1 and chi_c2 charmonium states are measured in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector at the LHC using 4.5 fb-1 of integrated luminosity. The chi_c states are reconstructed through the radiative decay chi_c --> J/psi + gamma (with J/psi --> mu+ mu-) where photons are reconstructed from gamma --> e+ e- conversions. The differential cross sections for both prompt and non-prompt production of the chi_c1 and chi_c2 states are measured as a function of both J/psi and chi_c pT. The fraction of prompt J/psi produced in feed-down from radiative chi_c decays is also measured in addition to the production rate of chi_c2 relative to chi_c1, for both prompt and non-prompt chi_c production. The measurements have not been corrected for the chi_c --> J/psi + gamma and J/psi --> mu+ mu- branching fractions. All measurements are made within the fiducial region ABS(YRAP(J/PSI)) < 0.75.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Digital pile-up rejection for plutonium experiments with solution-grown stilbene

A solution-grown stilbene detector was used in several experiments with plutonium samples including plutonium oxide, mixed oxide, and plutonium metal samples. Neutrons from different reactions and plutonium isotopes are accompanied by numerous gamma rays especially by the 59-keV gamma ray of 241Am. Identifying neutrons correctly is important for nuclear nonproliferation applications and makes neutron/gamma discrimination and pile-up rejection necessary. Each experimental dataset is presented with and without pile-up filtering using a previously developed algorithm. The experiments were simulated using MCNPX-PoliMi, a Monte Carlo code designed to accurately model scintillation detector response. Collision output from MCNPX-PoliMi was processed using the specialized MPPost post-processing code to convert neutron energy depositions event-by-event into light pulses. The model was compared to experimental data after pulse-shape discrimination identified waveforms as gamma ray or neutron interactions. We show that the use of the digital pile-up rejection algorithm allows for accurate neutron counting with stilbene to within 2% even when not using lead shielding

Bourne, M. M.↗

Scale-up of high specific activity 186g Re production using graphite-encased thick 186 W targets and demonstration of an efficient target recycling process

Production of high specific activity 186g Re is of interest for development of theranostic radiopharmaceuticals. Previous studies have shown that high specific activity 186g Re can be obtained by cyclotron irradiation of enriched 186 W via the 186 W(d,2n) 186g Re reaction, but most irradiations were conducted at low beam currents and for short durations. In this paper, enriched 186 W metal targets were irradiated at high incident deuteron beam currents to demonstrate production rates and contaminants produced when using thick targets. Full-stopping thick targets, as determined using SRIM, were prepared by uniaxial pressing of powdered natural abundance W metal or 96.86% enriched 186 W metal encased between two layers of graphite flakes for target material stabilization. An assessment of structural integrity was made on each target preparation. To assess the performance of graphite-encased thick 186 W metal targets, along with the impact of encasing on the separation chemistry, targets were first irradiated using a 22 MeV deuteron beam for 10 min at 10, 20, and 27 μA, with an estimated nominal deuteron energy of 18.7 MeV on the 186 W target material (after energy degradation correction from top graphite layer). Gamma-ray spectrometry was performed post EOB on all targets to assess production yields and radionuclidic byproducts. The investigation also evaluated a method to recover and recycle enriched target material from a column isolation procedure. Material composition analyses of target materials, pass-through/wash solutions and recycling process isolates were conducted with SEM, FTIR, XRD, EDS and ICP-MS spectrometry. Finally, to demonstrate scaled-up production, a graphite-encased 186 W target made from recycled 186 W was irradiated for ~2 h with 18.7 MeV deuterons at a beam current of 27 μA to provide 0.90 GBq (24.3 mCi) of 186g Re, decay-corrected to the end of bombardment. ICP-MS analysis of the isolated 186g Re solution provided data that indicated the specific activity of 186g Re in this scaled-up production run was 2.6±0.5 GBq/μg (70±10 Ci/mg).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Manufacturing techniques studies of ceramics by neutron and γ-ray radiography

In this study, the aim was to evaluate capabilities and constraints of radiographic imagery using thermal neutrons and gamma-rays as tools to identify the type of technique employed in ceramics manufacturing especially that used in prehistoric Brazilian pottery from Acre state. For this purpose, radiographic images of test objects made with clay of this region using both techniques - palette and rollers - have been acquired with a system comprised of a source of gamma-rays or thermal neutrons and a corresponding X-ray or neutron-sensitive Imaging Plate as detector. For the neutrongraphy samples were exposed to a thermal neutron flux of order of 10{sup 5}n.cm{sup −2}.s{sup −1} for 3 minutes at main port of Argonauta research reactor of the Instituto de Engenharia Nuclear - IEN/CNEN. The radiographic images using γ-rays from {sup 165}Dy (95 keV) and {sup 198}Au (412 keV) both produced at this reactor, have been acquired under an exposure time of a couple of hours. After acquisition, images have undergone a treatment to improve their quality through enhancement of their contrast, a procedure involving corrections of the beam divergence, sample shape and averaging of the attenuation map profile. Preliminary results show that difference between manufacturing techniques is better identified by radiography using low energy γ-rays from {sup 165}Dy rather than neutrongraphy or γ-rays from {sup 198}Au. Nevertheless, disregarding the kind of employed radiation, it should be stressed that feasibility to apply the technique is tightly tied to homogeneity of the clay itself and tempers due to their different attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗