Search NASA⌕ Search

SEARCH · Search NASA

Results for “geothermal location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Complementary Subsurface Characterization Methods to Develop a Geologic Model for the EGS Collab Experiment, Sanford Underground Research Facility

The EGS (Enhanced Geothermal Systems) Collab project was performed within the Sanford Underground Research Facility (SURF) with a goal of understanding processes and evaluation of models related to hydraulic stimulation of rock at depth. The present work deals with the development of Testbed 2 where experiments were conducted at a depth of 1.25 km and were located within a well-characterized testbed in a metamorphic, amphibolite host rock. A total of eleven boreholes varying in length between 10.6 m and 81.2 m were continuously cored to develop the testbed. In addition to the continuous coring of the amphibolite host rock, geophysical instrumentation supporting electrical resistivity tomography (ERT), microearthquake (MEQ) detection, and optical fiber providing distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) were installed in the monitoring boreholes, all of which produced a comprehensive complementary suite of characterization and monitoring technologies. Pre-stimulation characterization of the groundwater conditions identified only two hydraulically significant fractures, neither of which transects the central portion of the testbed. Flow and pressure monitoring indicated low preexisting pore pressure conditions likely affected by the mine openings.

15 GEOTHERMAL ENERGY↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Utah FORGE: Updated Seismic Event Catalogue from the April, 2022 Stimulation of Well 16A(78)-32

These are revised catalogs, related to the April, 2022 well 16A(78)-32 stimulation (phases 1,2, & 3), provided by Geo Energie Suisse (GES) that include additional events at the start of Stage 1 and some tidying up of some locations. These catalogs also include events for additional events that were auto-located to provide a larger dataset for statistical analyses, like b-value calculations. The actual auto-locations have been removed to prevent spurious location plots being created. Times are recorded in UTC (Coordinate Universal Time), and the coordinate reference system is UTM Zone 12N, NAD83.

15 GEOTHERMAL ENERGY↗

Thermal Characterization and Exhumation of Northwest San Juan Basin Area, NM

The San Juan Basin (SJB), located in southwestern Colorado northwestern New Mexico, containing Paleozoic through middle Cenozoic strata, formed as a partitioned basin approximately 80 Ma in response to the Laramide orogeny. The SJB is a commercially mature, petroleum-producing basin, and currently being explored for CCUS and geothermal resources. Modern heat flow within the SJB is spatially variable with higher geothermal gradients in its northern and eastern portions. The temporal history of the basin thermal history is essential for understanding capacity for carbon storage and geothermal exploration. We present thermochronometric analyses of two surface and two subsurface samples to constrain spatial-temporal thermal evolution of the northwestern San Juan Basin. Apatite (U-Th)/He thermochronometric analyses were conducted on Cliff House and Kirtland Formation outcrops and subsurface samples of the Ojo Alamo and Pictured Cliffs Formations from a DOE funded, CCUS project pilot-well. In addition, vitrinite reflectance data and 1D basin modelling constrain possible time-temperature pathways of the samples in an area where no previous studies have constrained the uplift/exhumation of the Hogback Monocline using thermochronometry. Modeling suggests that elevated subsurface temperatures developed simultaneously with regional late Oligiocene volcanism in the San Juan Volcanic field and timing of maximum burial in the SJB. Late Miocene to Pliocene cooling/exhumation through the apatite (U-Th)/He partial retention zone support stratigraphic evidence of the Colorado Plateau uplift, possibly regional epeirogenic uplift driven by mantle processes.

02 PETROLEUM↗

Shallow Geothermal Resources for Cooling Applications at the University of Hawai‘i

Scientists at Berkeley Lab have teamed up with The University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s (DOE’s) Energy Transitions Initiative Partnership Project (ETIPP) to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology for building cooling, energy efficiency, and emissions reduction applications in Hawai’i. The team is assessing the data necessary to model the feasibility of deploying this technology, the actual models that will be used, and what hurdles need to be overcome to install a demonstration case. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project, and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, making it crucial to select sites with large enough values of these properties. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Both closed-loop and open-loop systems are being investigated. Another option being considered is using cool seawater as the source of chill. Currently work is progressing on two fronts. A hydrogeologic model for a closed-loop system is being developed for the Stan Sheriff Center at the UH Manoa campus, where a subsurface karst system immediately downgradient of the borefield may provide efficient removal of heated groundwater. The team will also develop a technoeconomic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air conditioning system. At the state scale, geographic information system (GIS) layers of various attributes relevant for GHE are being combined to develop an overall favorability map for employing GHE in Hawai‘i.

Doughty, C↗

Autonomous extraction of millimeter-scale deformation in InSAR time series using deep learning

Systematically characterizing slip behaviours on active faults is key to unraveling the physics of tectonic faulting and the interplay between slow and fast earthquakes. Interferometric Synthetic Aperture Radar (InSAR), by enabling measurement of ground deformation at a global scale every few days, may hold the key to those interactions. However, atmospheric propagation delays often exceed ground deformation of interest despite state-of-the art processing, and thus InSAR analysis requires expert interpretation and a priori knowledge of fault systems, precluding global investigations of deformation dynamics. Here, we show that a deep auto-encoder architecture tailored to untangle ground deformation from noise in InSAR time series autonomously extracts deformation signals, without prior knowledge of a fault’s location or slip behaviour. Applied to InSAR data over the North Anatolian Fault, our method reaches 2 mm detection, revealing a slow earthquake twice as extensive as previously recognized. We further explore the generalization of our approach to inflation/deflation-induced deformation, applying the same methodology to the geothermal field of Coso, California.

58 GEOSCIENCES↗

Directional Cooling-Induced Fracturing Westerly Granite Test Results

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission is an animation of the AEs, a graphic displaying the temperature changes, and the measured data.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Phase 1a Tensor Strainmeter Data for the April, 2022 Stimulation of Well 16A(78)-32

Data from two Tensor Optical Fiber Strainmeters that were operational during Stages 1, 2, and 3 of the April, 2022 stimulation of well 16A(78)-32. Each csv file contains data from each stimulation stage (stage1, stage2, stage3) for both Phase 1a strainmeter installations (FS01, formerly FS-C, and FS02, formerly FS1-2) in human-readable comma-separated value text files. There are two header lines in each file describing the data contained in that column along with their units, respectively. Data have been decimated from 2 to 1 Hz to match the Pason data found in the linked GDR dataset below (16A78-32 Stimulation Pason Data). These files contain the time series spanning the same time interval as the Pason data as well as ambient data for 5 hours before the stimulation and 5 hours following shut in. The station locations were chosen based on their proximity to the borehole seismometers owned and operated by the University of Utah. See README.txt for more information.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Updated FMI Fracture Log from Well 16A(78)-32

This dataset consists of an Excel spreadsheet detailing the fracture picks from a reinterpretation of the formation micro-imaging (FMI) log from Utah FORGE well 16A(78)-32. The provided information details fracture location, geometry, and type. Also included here is a link to the original raw and processed FMI logs, as well as other data from the 2021 well logging.

15 GEOTHERMAL ENERGY↗

A Geospatial Cost Comparison of CO2 Plume Geothermal (CPG) Power and Geologic CO2 Storage

CO 2 Plume Geothermal (CPG) power plants can use gigatonne-levels of CO 2 sequestration to generate electricity, but it is unknown if the resources that support low-cost CPG power align with the resources that support low-cost CO 2 sequestration. Here, we estimate and compare the geospatially-distributed cost of CPG and CO 2 storage across a portion of North America. We find that the locations with lowest-cost CO 2 storage are different than the locations with lowest-cost CPG. There are also locations with low-cost CO 2 storage (<$5/tCO 2 ) that do not support CPG power generation due to insufficient reservoir transmissivity or temperature. Thus, CPG development may require electricity prices that are greater than the levelized cost of electricity (LCOE) to offset the increased cost of sequestration. We introduce the “Additional Cost of Electricity (ACOE)” metric to account for this cost and add it to the LCOE to calculate breakeven electricity prices that are required for CPG development. We find that breakeven prices are lower when new CO 2 injection wells are drilled specifically for CPG (i.e., “greenfield” CPG development) compared to if only existing CO 2 sequestration injection wells are used (i.e., “brownfield” CPG development). This is because comparatively few wells are needed for sequestration-only, and the increased power capacity from having more CPG wells outweighs the increased costs from more drilling. We also find that sequestered CO 2 could be used to approximately triple the United States geothermal electricity power capacity via a single CPG “sweet spot” in South Dakota, but that breakeven electricity price for this development is on the order of $200/MW e h.

15 GEOTHERMAL ENERGY↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

Utah FORGE Raw Microgravity Composite Data: Updated 10/2021.

This is a microgravity dataset from the Utah FORGE site near Milford, Utah. This composite dataset was updated in October, 2021 and contains data from December 17th, 2018 through September 24th, 2021. The data includes the GPS location of the measurement, date of the measurement, name of the station, relative difference in gravity, and coordinates of the station. This data was generated by the Utah Geological Survey.

15 GEOTHERMAL ENERGY↗

Utah FORGE: GES Well 16A(78)-32 and Well 16B(78)-32 Stimulation Seismic Event Catalogs

This dataset contains seismic event catalogs from the hydraulic stimulation of wells 16A(78)-32 and 16B(78)-32 at the Utah FORGE site in April 2024. The data was collected by Geo Energy Suisse (GES) using a variety of seismic monitoring technologies, including 3-component (3C) geophones and distributed acoustic sensing (DAS) systems. These technologies were deployed across several locations, including wells 16A, 16B, and Delano-1, with sensor arrays at multiple depths to capture microseismic activity during the stimulations. The catalogs provide both real-time and manually checked seismic event locations, with detailed parameters such as trigger conditions, velocity models, and data acquisition settings. The dataset includes information on the stimulation stages, event rates, and hydraulic injection conditions for each well, with a report detailing the data acquisition configuration and seismic event location methodologies. Users will need to reference the included report for a complete understanding of the sensor network, data processing techniques, and accuracy considerations.

15 GEOTHERMAL ENERGY↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗

Context and mitigation of lost circulation during geothermal drilling in diverse geologic settings

Lost circulation is one of the most common and expensive problems facing geothermal energy development, representing up to 30% of drilling costs. We examined drilling records from four geothermal fields—McGinness Hills in central Nevada, Don A. Campbell and Steamboat Hills in western Nevada, and Puna Geothermal Venture on the Big Island of Hawai'i— to identify geologies most prone to lost circulation, as well as common mitigation strategies. Depths of lost circulation events varied, but their frequency often increased in the production interval. Lost circulation commonly occurred near fault intersections, and heavily faulted fields like McGinness Hills and Don A. Campbell showed secondary mineralization within approximately 100 m (328 ft) or less of where circulation was lost. Lost circulation mitigation strategies included using locally available materials (e.g., cotton seed hulls) as well as more expensive proprietary lost circulation materials, cement plugs above the reservoir, and drilling blind with aerated, polymer-based mud in the production zone. Addressing lost circulation using a well thought out decision-making approach and materials above the reservoir will save time and cost, and provide needed well integrity. Mitigation often requires a series of steps, typically applied from perceived least expensive to most, and are dependent on the severity and location in the well where circulation was lost and availability of materials. Placing cement plugs can cure lost circulation events, however these plugs are often expensive, time-consuming, and may not be successful.

15 GEOTHERMAL ENERGY↗

Utah FORGE Composite Raw Gravity Data 2021

This is a composite raw gravity dataset of the Utah FORGE area taken over time from December 2018 to to June 2021. The data shows differences in local gravity at different location across Utah FORGE. Included with the gravity data is the NAD83 UTM coordinates of each station in meters. More detailed information can be found in the readme included in the data resource.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗

Cooling-induced reactivation of distant faults during long-term geothermal energy production in hot sedimentary aquifers

Deep geothermal energy (DGE) represents an opportunity for a sustainable and carbon-free energy supply. One of the main concerns of DGE is induced seismicity that may produce damaging earthquakes, challenging its widespread exploitation. It is widely believed that the seismicity risk can be controlled by using doublet systems circulating water to minimize the injection-induced pressure changes. However, cold water reinjection may also give rise to thermal stresses within and beyond the cooled region, whose potential impacts on fault reactivation are less well understood. Here, we investigate by coupled thermo-hydro-mechanical modeling the processes that may lead to fault reactivation in a hot sedimentary aquifer (HSA) in which water is circulated through a doublet. We show that thermal stresses are transmitted much ahead of the cooled region and are likely to destabilize faults located far away from the doublet. Meanwhile, the fault permeability mainly controls the fault reactivation timing, which entails the importance of employing appropriate characterization methods. This investigation is crucial for understanding the mechanisms controlling induced seismicity associated with DGE in a HSA and allows the success of future DGE projects.

15 GEOTHERMAL ENERGY↗