Search NASA⌕ Search

SEARCH · Search NASA

Results for “germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

RASA Field Performance at US International Monitoring Stations

This report attempts to collate, analyze, and summarize RASA performance over time at each of 11 US operated IMS stations. The performance over time was compared to routine maintenance operations. The data, in general, were summarized into a set analyzed almost exclusively in Excel. The data set allows for further probing into RASA performance over time. The data set would permit data to be routinely added for continued analysis. In general, all RASA systems ran within the CTBTO mandated the MDA requirements over their current lifetime of operations. The largest impacts to performance appeared to arise from variabilities of Germanium gamma detectors as they were replaced. It is noted that the air volumes of samples were not provided and had to be assumed to be constant over the period analyzed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Coincidence Counting for Improving Minimal Detectable Activity of 110m Ag in Single Particle Gamma Analysis

Post-irradiation examination (PIE) of fuel particles from the fourth Advanced Gas Reactor Fuel Development and Qualification (AGR) Program irradiation (AGR-5/6/7) is being performed at Oak Ridge National Laboratory (ORNL). Tristructural isotropic (TRISO)-coated particles and associated compacts for the AGR-5/6/7 experiment fabricated by BWX Technologies Nuclear Operations Group were formed into a graphite matrix compact and irradiated at the Advanced Test Reactor at Idaho National Laboratory. At ORNL, particles are deconsolidated from the graphite matrix compact and individually scanned for emitted gamma rays with the Irradiated Microsphere Gamma Analyzer (IMGA). The IMGA system comprises a single high purity germanium (HPGe) detector, an automated particle handling vacuum system, and an ORTEC DSPEC-50 digital spectrometer for gamma ray analysis. IMGA quantifies gamma ray-emitting fission product inventories of individual TRISO particles, and these inventories can be compared with the measured average inventories per particle and radionuclide inventories predicted by AGR-5/6/7 physics calculations to determine if a particle experienced radionuclide release. Details on IMGA data collection methods can be found in the literature. The TRISO particle’s SiC layer provides structural support, as well as a barrier for fission product release during irradiation or subsequent safety testing. A weakened or compromised SiC layer can be identified by the release of radionuclides, such as 137 Cs, which is detected by IMGA. However, select radionuclides, such as 90 Sr, 110 mAg, and 154 Eu have been shown to migrate through an intact SiC layer. Measurement of the radionuclide 110 mAg is significant as its release has been shown to be particularly sensitive to in-reactor conditions (e.g., temperature) with broad variable particle to-particle release behaviors observed within a single compact. As such, 110 mAg activity is often used for particle selection for comprehensive PIE as bounding 110 mAg retention particles are hypothesized to represent limits in particle behaviors within a compact. As TRISO particle fuel PIE activities continue over time, IMGA measurements of the 110 mAg inventory are eventually hindered because of its relatively short half-life (~250 days). As the fuel ages from its end of irradiation (EOI) date, the measurement uncertainty and minimum detectable activity (MDA) of 110m Ag increase because the detector background continuum begins to dominate. For particles from the second AGR irradiation experiment (AGR-2), the 110m Ag MDA was above 20% of the calculated average particle inventory after approximately five half-lives, and 110m Ag activity was no longer measurable with IMGA after approximately seven half-lives. Therefore, coincidence counting approaches have been explored to determine feasibility of leveraging new approaches to overcome limitations associated with increasing MDA over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The GammaSpec Package for Automated Gamma-ray Analysis (V.1.0)

This report describes the GammaSpec package, a tool developed to automate the analysis and comparison of gamma-ray spectra. The goal of this tool is to drastically reduce, or even eliminate, currently time consuming processes for comparing large sets of gamma-ray measurements. There are a number of potential applications for this work throughout the laboratory, but particularly within Global Security. Current work flows where large numbers of measured spectra must be compared for anomolies and outliers often consist of loading and visually inspecting individual spectra, or utilizing small-batch tools. One such example is the PeakEasy tool also developed at LANL. PeakEasy has a robust and tested feature set for calibrating, identifying, and fitting gamma-ray spectra. However it’s intention was not for batch processing and automated comparison of large numbers of spectra. This tool is not intended to replace PeakEasy in an analyzers arsenal, but to instead augment it. The intention here is to automate the isolation of spectra of particular interest, which can then be studied in further detail. This report is arranged as follows. Section 2 lays out the design goals and desired functionality of the package. Section 3 describes the algorithms developed and chosen to accomplish those goals. Section 4 describes the primary interaction with the tool, as well as it’s resulting output. Following these sections, results are presented from a set of example datasets from High Purity Germanium (HPGe) detectors in Sec. 5. Finally, the current status is summarized in Sec. 6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGN AND VALIDATION OF A GAMMA-RAY SCANNING SYSTEM FOR MEASURING IRRADIATED NUCLEAR FUEL (ABSTRACT)

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Angular Correlations of Gamma Rays from Fission Product Solution

Fission products from photon-induced fission are routinely used at Idaho National Laboratory as part of nuclear forensics activities. Typically, the focus is on fission products with relatively large fission yields (Ba-140, Mo-99, etc.). The nuclear data associated with the well-known isotopes have small uncertainties, and many have well-known angular correlations between emitted gamma-rays, if applicable. However, for isotopes with smaller fission yields or less intense gamma-ray emission intensities, the nuclear decay schemes and gamma-ray emission intensities may be less well-known. The Germanium Rotational Measurements for Angular Correlation (GeRMAC) system was designed to use two high-purity germanium (HPGe) detectors in a coincidence counting set-up but allows one of the HPGe detectors to rotate at a constant distance from a radioactive source, changing the relative angle between the two HPGe detectors. Angular correlations can then be determined from the relative photopeak areas between two gamma-rays emitted as part of the same nuclear decay. By recording the HPGe spectra in list mode, the angular correlations of gamma-rays emitted from complex sources, consisting of multiple isotopes, can be measured simultaneously and the individual isotope emissions can be isolated. Using the GeRMAC system, a multi-isotope fission product source, produced with photon-induced fission of U-238, was measured using a single rotational arc (180 degrees) to obtain the angular correlation between gamma-rays emitted by the large number of fission products contained in the solution with an angular accuracy of 1 degree. In particular, La-140 (38 gamma rays) and Nd-147 (26 gamma rays) are of interest to the nuclear forensics community.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Measurements of Irradiated Low Enriched Fuel with a Gamma-Ray Scanning System (ANIMMA 2023 Conference Presentation)

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This article documents the modeling, benchmarking measurements, and the calculated number of fissions per gram in the SERTTA-A rodlet which was previously irradiated at TREAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

Revisiting the dark matter interpretation of excess rates in semiconductors

In light of recent results from low-threshold dark matter detectors, we revisit the possibility of a common dark matter origin for multiple excesses across numerous direct detection experiments, with a focus on the excess rates in semiconductor detectors. We explore the interpretation of the low-threshold calorimetric excess rates above 40 eV in the silicon SuperCDMS Cryogenic Phonon Detector and above 100 eV in the germanium EDELWEISS Surface detector as arising from a common but unknown origin, and demonstrate a compatible fit for the observed energy spectra in both experiments, which follow a power law of index α = 3.4 3 - 0.06 + 0.11 . Despite the intriguing scaling of the normalization of these two excess rates with approximately the square of the mass number A 2 , we argue that the possibility of common origin by dark matter scattering via nuclear recoils is strongly disfavored, even allowing for exotic condensed matter effects in an as-yet unmeasured kinematic regime, due to the unphysically large dark matter velocity required to give comparable rates in the different energy ranges of the silicon and germanium excesses. We also investigate the possibility of inelastic nuclear scattering by cosmic ray neutrons, solar neutrinos, and photons as the origin, and quantitatively disfavor all three based on known fluxes of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of collective modes of excitations in 59 Co, 59 Ni, and 61 Co and the influence of the $g_{9/2}$ orbital

High-spin states in 59 Co (Z = 27), 59 Ni (Z = 28), and 61 Co have been populated by the fusion evaporation reactions, 48 Ti( 14 C, p2n ) 59 Co, 48 Ti( 14 C, 3 n ) 59 Ni, and 50 Ti( 14 C, p2n ) 61 Co. The 9 MV tandem accelerator at the John D. Fox Laboratory, Florida State University (FSU) was used to accelerate the 14 C beam and the deexciting γ rays were detected by the FSU detector array consisting of six high-purity germanium (HPGe) clover detectors and three single crystals. Directional correlation of the $γ$ rays deexciting oriented states (DCO ratios) and polarization asymmetry measurements helped to establish spin and parities of the excited states whenever possible. The level scheme of 59 Co has been expanded with the inclusion of positive-parity states up to 31/2 + at around 11 MeV. The 59 Ni positive-parity states known from previous study were verified with modifications to some of the spins and parities. On the other hand, the negative-parity states were extended to 31/2 at an excitation energy of 12 MeV. No new transition was observed for 61 Co, but one of the major bands has been reassigned as consisting of positive-parity states by reason of this study. Importantly, excitations observed within the f 7/2 , p 3/2 , f 5/2 , and p 1/2 orbitals, and also across the N = 40 subshell closure into the g 9/2 orbital was established by comparison with large-scale shell-model calculations for the three nuclei studied.

59 ≤ A ≤ 89↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗