Search NASA⌕ Search

SEARCH · Search NASA

Results for “gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The half-mass radius of MaNGA galaxies: effect of IMF gradients

Gradients in the stellar populations (SP) of galaxies – e.g. in age, metallicity, stellar initial mass function (IMF) – can result in gradients in the stellar-mass-to-light ratio, M * / L . Such gradients imply that the distribution of the stellar mass and light is different. For old SPs, e.g. in early-type galaxies at z ∼ 0, the M * / L gradients are weak if driven by variations in age and metallicity, but significantly larger if driven by the IMF. A gradient which has larger M * / L in the centre increases the estimated total stellar mass ( M * ) and reduces the scale which contains half this mass ( R e,* ), compared to when the gradient is ignored. For the IMF gradients inferred from fitting MILES simple SP models to the H β, 〈Fe〉, [MgFe], and TiO 2SDSS absorption lines measured in spatially resolved spectra of early-type galaxies in the MaNGA survey, the fractional change in R e,* can be significantly larger than that in M * , especially when the light is more centrally concentrated. The R e,* – M * correlation which results from accounting for IMF gradients is offset to smaller sizes by 0.3 dex compared to when these gradients are ignored. Comparisons with ‘quiescent’ galaxies at higher z must account for evolution in SP gradients (especially age and IMF) and in the light profile before drawing conclusions about how R e,* and M * evolve. Here, the implied merging between higher z and the present is less contrived if R e,* / R e at z ∼ 0 is closer to our IMF-driven gradient calibration than to unity.

79 ASTRONOMY AND ASTROPHYSICS↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

Strong gradient neoclassical transport in the plateau regime

Strong gradient regions in tokamaks such as the pedestal or internal transport barriers are regions of reduced turbulence where neoclassical transport can play a dominant role. In pedestals, gradient lengths comparable to the ion poloidal gyroradius have been measured. Standard neoclassical theory can miss important strong gradient effects in these regions because it assumes that the gradient length scales of density, temperature and potential are larger than the ion poloidal gyroradius. We extend plateau regime neoclassical theory into regions of gradients of the order of the ion poloidal gyroradius to capture strong gradient effects on transport processes in the pedestal and internal transport barriers. The fundamental idea behind our new framework is to keep a scale separation between the orbit widths and the gradient length scales by performing a large aspect ratio expansion. In the plateau regime, strong gradients cause poloidal variation that is in–out as well as up–down asymmetric. We study two different test cases assuming either radial force balance or the absence of turbulence and show that strong gradient effects can enhance or reduce standard neoclassical theory predictions in the plateau regime in strong gradient regions.

fusion plasma↗

Nonlinear verification of a linear critical gradient model for energetic particle transport by Alfven eigenmodes

Here, a “stiff transport” critical gradient model of energetic particle (EP) transport by EPdriven Alfven eigenmodes (AEs) is verified against local nonlinear gyrokinetic simulations of a well-studied beam-heated DIII-D discharge 146102. A greatly simplifying linear “recipe” for the limiting EP-density gradient (critical gradient) is considered here. In this recipe, the critical gradient occurs when the AE linear growth rate, driven mainly by the EP gradient, exceeds the ion temperature gradient (ITG) or trapped electron mode (TEM) growth rate, driven by the thermal plasma gradient, at the same toroidal mode number (n) as the AE peak growth, well below the ITG/TEM peak n. This linear recipe for the critical gradient is validated against the critical gradient determined from far more expensive local nonlinear simulations in the gyrokinetic code GYRO, as identified by the point of transport runaway when all driving gradients are held fixed. The reduced linear model is extended to include the stabilization from equilibrium E×B velocity shear. The nonlinear verification unambiguously endorses one of two alternative recipes proposed in Ref. 1: the EP-driven AE growth rate should be determined with rather than without added thermal plasma drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ORIGIN AND EVOLUTION OF THE ABUNDANCE GRADIENT ALONG THE MILKY WAY DISK

Based on a simple model of the chemical evolution of the Milky Way disk, we investigate the disk oxygen abundance gradient and its time evolution. Two star formation rates (SFRs) are considered, one is the classical Kennicutt-Schmidt law ({psi} = 0.25{sigma}{sup 1.4} {sub gas}, hereafter C-KS law), another is the modified Kennicutt law ({upsilon} = {alpha}{sigma}{sup 1.4} {sub gas}(V/r), hereafter M-KS law). In both cases, the model can produce some amount of abundance gradient, and the gradient is steeper in the early epoch of disk evolution. However, we find that when C-KS law is adopted, the classical chemical evolution model, which assumes a radially dependent infall timescale, cannot produce a sufficiently steep present-day abundance gradient. This problem disappears if we introduce a disk formation timescale, which means that at early times, infalling gas cools down onto the inner disk only, while the outer disk forms later. This kind of model, however, will predict a very steep gradient in the past. When the M-KS law is adopted, the model can properly predict both the current abundance gradient and its time evolution, matching recent observations from planetary nebulae and open clusters along the Milky Way disk. Our best model also predicts that outer disk (artificially defined as the disk with R{sub g} {>=} 8 kpc) has a steeper gradient than the inner disk. The observed outer disk gradients from Cepheids, open clusters, and young stars show quite controversial results. There are also some hints from Cepheids that the outer disk abundance gradient may have a bimodal distribution. More data is needed in order to clarify the outer disk gradient problem. Our model calculations show that for an individual Milky Way-type galaxy, a better description of the local star formation is the M-KS law.

99 GENERAL AND MISCELLANEOUS↗

OPTICAL-NEAR-INFRARED COLOR GRADIENTS AND MERGING HISTORY OF ELLIPTICAL GALAXIES

It has been suggested that merging plays an important role in the formation and the evolution of elliptical galaxies. While gas dissipation by star formation is believed to steepen metallicity and color gradients of the merger products, mixing of stars through dissipation-less merging (dry merging) is believed to flatten them. In order to understand the past merging history of elliptical galaxies, we studied the optical-near-infrared (NIR) color gradients of 204 elliptical galaxies. These galaxies are selected from the overlap region of the Sloan Digital Sky Survey (SDSS) Stripe 82 and the UKIRT Infrared Deep Sky Survey (UKIDSS) Large Area Survey (LAS). The use of optical and NIR data (g, r, and K) provides large wavelength baselines, and breaks the age-metallicity degeneracy, allowing us to derive age and metallicity gradients. The use of the deep SDSS Stripe 82 images makes it possible for us to examine how the color/age/metallicity gradients are related to merging features. We find that the optical-NIR color and the age/metallicity gradients of elliptical galaxies with tidal features are consistent with those of relaxed ellipticals, suggesting that the two populations underwent a similar merging history on average and that mixing of stars was more or less completed before the tidal features disappeared. Elliptical galaxies with dust features have steeper color gradients than the other two types, even after masking out dust features during the analysis, which can be due to a process involving wet merging. More importantly, we find that the scatter in the color/age/metallicity gradients of the relaxed and merging feature types decreases as their luminosities (or masses) increase at M > 10{sup 11.4} M{sub Sun} but stays large at lower luminosities. Mean metallicity gradients appear nearly constant over the explored mass range, but a possible flattening is observed at the massive end. According to our toy model that predicts how the distribution of metallicity gradients changes as a result of major dry merging, the mean metallicity gradient should flatten by 40% and its scatter becomes smaller by 80% per a mass-doubling scale if ellipticals evolve only through major dry merger. Our result, although limited by a number statistics at the massive end, is consistent with the picture that major dry merging is an important mechanism for the evolution for ellipticals at M > 10{sup 11.4} M{sub Sun }, but is less important at the lower mass range.

79 ASTRONOMY AND ASTROPHYSICS↗

Gradient-Informed Design Optimization of Select Nuclear Systems

In this work, we present a gradient-informed design optimization of nuclear reactor core components based on neutronics objectives with both continuous and discrete materials. The main argument in favor of using gradient-informed design optimization is that it scales well with increasing dimensionality of the design space. First, a challenge problem with 121 free parameters is solved with a gradient-informed method and then with a genetic algorithm. Then, a challenge problem to optimize the flux profile of a simplified assembly with eight axial zones is solved. Both challenge problems are solved using directly calculated derivatives from Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) in the SCALE package. Furthermore, we demonstrate how a discrete optimization problem—selection of materials for 121 voxels—can be lifted into a continuous problem with mixed materials. In the continuous space, adjoint-based gradients are well-defined, and gradient descent is applicable. Then, a forcing function is introduced that with the selection of an appropriately sized hyperparameter can be used to guide the optimized continuous solution back into a discrete solution. This paper presents an account of the challenges that were faced when applying a gradient-informed optimization algorithm using a Monte Carlo calculation to estimate the gradient information and compares a gradient descent optimization method to a genetic algorithm optimization of the same geometry. Overall, this work demonstrates the potential use of adjoint-based gradient calculations in design optimization of nuclear systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synergetic Strengthening of Grain Refinement and Texture in Gradient Zircaloy-4 by Surface Mechanical Rolling Treatment

A Zircaloy-4 rod was subjected to surface mechanical rolling treatment (SMRT) to form a gradient structure, and the evolution of the resulting sub-grain-boundary property and texture across the gradient structure was characterized using electron backscattered diffraction. Dual-gradient structures in grain size and orientation were formed; the grain size was refined from several microns at the center to approximately 400 nm at the topmost surface. Texture analysis revealed that the c-axis gradually tilted from a random orientation toward the parallel-to-radial direction on the radial–tangential plane. The SMRT-induced formation of the dual-gradient microstructure is attributed to the formation of gradient distributions of stress and strain, which resulted in various deformation mechanisms (twinning and dislocation) being active at different depths. During the SMRT process, twinning and dislocations were activated to refine the grains. When the dual-gradient microstructure formed, twinning was mainly activated at the subsurface near the matrix, whereas dislocations were activated across the entire gradient. The geometrically necessary dislocation density increased with decreasing depth and then slightly decreased near the surface. The synergetic strengthening of the dual-gradient microstructure resulted in a gradient distribution of the microhardness near the surface. Thus, the Zircaloy-4 rod exhibited a good combination of strength and ductility.

36 MATERIALS SCIENCE↗

Binary Electroosmotic-Pump Nanoflow Gradient Generator for Miniaturized High-Performance Liquid Chromatography

High-performance liquid chromatography (HPLC) plays an important role in biotechnology, and a majority of chromatographic separations use gradient elution. While gradient generators can be built in different formats, binary pumps or quaternary pumps are most frequently used for gradient generator constructions. We have recently developed a high-pressure electroosmotic pump (EOP); the pump can be manufactured at a cost of a few hundred dollars. However, it is challenging to use this pump to deliver a gradient eluent directly. In this study, we first improve the monolith preparation by applying a pressure to the monomer solution during polymerization. We assemble a binary EOP gradient generator and discuss the relationship between the gradient profile and voltage applied to the EOP. Here we demonstrate the feasibility of the binary EOP gradient generator for generating a smooth and reproducible nanoflow gradient. After integration of the gradient generator into a miniaturized HPLC system, we use the HPLC system for separating peptide mixtures from trypsin-digested proteins. Lastly, the performance comparison between the above miniaturized HPLC system and an Agilent 1200 HPLC system exhibits comparable efficiencies, resolutions, and peak capacities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

60 APPLIED LIFE SCIENCES↗

Examination of stiff ion temperature gradient mode physics in simulations of DIII-D H-mode transport

A systematic evaluation of gyrokinetic and gyrofluid model predictions of ion temperature gradient (ITG) stability and transport using parameters from DIII-D high confinement mode (H-mode) plasmas has been performed. The nonlinear CGYRO code is used to make the gyrokinetic predictions, and the quasilinear TGLF model for the corresponding gyrofluid predictions. The assessments are made at three radii (normalized toroidal flux ρtor = 0.4, 0.55, and 0.7) in three different plasma scenarios with varying levels of neutral beam heating and torque. For each of the nine cases (3 radii × 3 scenarios) considered, ITG turbulence is found to be the dominant long-wavelength instability and transport mechanism. The inclusions of both transverse magnetic fluctuations and dynamic fast beam ions are stabilizing for all cases considered, with strongest effects seen at ρor = 0.4 where the fast ion population and normalized plasma pressure β = 2μ0nT/B2 are highest. The further inclusion of parallel magnetic fluctuations does not have a meaningful impact on the ITG turbulence in these scenarios, but does destabilize (in combination with fast ions) new high-frequency instabilities at ρtor = 0.4 in the high power scenarios. In each case the linear and nonlinear ITG critical gradients are predicted to be lower than the measured ITG scale lengths and their associated uncertainties. Inclusion of equilibrium flow shear in the transport predictions generally leads to an upshift in effective critical gradient rather than a qualitative change in the predicted stiffness, with stronger responses typically seen in the gyrokinetic predictions than in the gyrofluid results. However, in most cases these upshifted gradients still remain below the measured values and their uncertainties. Although the predicted critical gradients are below the measured gradients, both models predicted flux-matching gradients consistent with measured values in six of the nine cases considered, with no clear systematic over- or underprediction. Thus, while the experimental ion temperature profiles do not appear to be closely pinned to the ITG critical gradient, both gyrokinetic and gyrofluid models are able to accurately match the measured gradients reasonably well in most cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient Ensemble-Based Stochastic Gradient Methods for Optimization Under Geological Uncertainty

Ensemble-based stochastic gradient methods, such as the ensemble optimization (EnOpt) method, the simplex gradient (SG) method, and the stochastic simplex approximate gradient (StoSAG) method, approximate the gradient of an objective function using an ensemble of perturbed control vectors. These methods are increasingly used in solving reservoir optimization problems because they are not only easy to parallelize and couple with any simulator but also computationally more efficient than the conventional finite-difference method for gradient calculations. In this work, we show that EnOpt may fail to achieve sufficient improvement of the objective function when the differences between the objective function values of perturbed control variables and their ensemble mean are large. On the basis of the comparison of EnOpt and SG, we propose a hybrid gradient of EnOpt and SG to save on the computational cost of SG. We also suggest practical ways to reduce the computational cost of EnOpt and StoSAG by approximating the objective function values of unperturbed control variables using the values of perturbed ones. We first demonstrate the performance of our improved ensemble schemes using a benchmark problem. Results show that the proposed gradients saved about 30–50% of the computational cost of the same optimization by using EnOpt, SG, and StoSAG. As a real application, we consider pressure management in carbon storage reservoirs, for which brine extraction wells need to be optimally placed to reduce reservoir pressure buildup while maximizing the net present value. Results show that our improved schemes reduce the computational cost significantly.

58 GEOSCIENCES↗

Comparing linear ion-temperature-gradient-driven mode stability of the National Compact Stellarator Experiment and a shaped tokamak

One metric for comparing confinement properties of different magnetic fusion energy configurations is the linear critical gradient of drift wave modes. The critical gradient scale length determines the ratio of the core to pedestal temperature when a plasma is limited to marginal stability in the plasma core. The gyrokinetic turbulence code GS2 was used to calculate critical temperature gradients for the linear, collisionless ion temperature gradient (ITG) mode in the National Compact Stellarator Experiment (NCSX) and a prototypical shaped tokamak, based on the profiles of a JET H-mode shot and the stronger shaping of ARIES-AT. While a concern was that the narrow cross section of NCSX at some toroidal locations would result in steep gradients that drive instabilities more easily, it is found that other stabilizing effects of the stellarator configuration offset this so that the normalized critical gradients for NCSX are competitive with or even better than for the tokamak. For the adiabatic ITG mode, NCSX and the tokamak had similar adiabatic ITG mode critical gradients, although beyond marginal stability, NCSX had larger growth rates. However, for the kinetic ITG mode, NCSX had a higher critical gradient and lower growth rates until a/L{sub T} Almost-Equal-To 1.5 a/L{sub T,crit}, when it surpassed the tokamak's. A discussion of the results presented with respect to a/L{sub T} vs. R/L{sub T} is included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Long-gradient separations coupled to tandem MS were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional LC-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in LOQ for target proteins in human female serum. Based on at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in non-depleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or sub-ng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and ELISA measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM offers at least 3 times higher multiplexing capacity than conventional LC-SRM due to ~3-fold increase in average peak widths for a 300-min gradient compared to a 45-min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Shi, Tujin↗

Single Molecule Spectroscopy Studies of Acid–Base Chemical Gradients Using Nile Red as a Probe of Local Surface Acidity

Single molecule spectroscopy studies of local acidity along bifunctional acid-base gradients are reported. Gradients are prepared by directional vapor phase diffusion and subsequent reaction of 3-aminopropyl-trimethoxysilane with a uniform silica film. Gradient formation is confirmed by spectroscopic ellipsometry and by static water contact angle measurements. X-ray photoelectron spectroscopy is used to characterize the nitrogen content and degree of nitrogen protonation along the gradient. Nile Red is employed as the probe dye in single molecule spectroscopy studies of these gradients. While Nile Red is well-known for its solvent sensitivity, it is used here, for the first time, to sense the acid/base properties of the film in two-color wide-field fluorescence imaging experiments. The data reveal broad bimodal distributions of Nile Red emission spectra that vary along the gradient direction. The single-molecule results are consistent with solution-phase ensemble acid/base studies of the dye. The former reveal a gradual transition from a surface dominated by basic aminosilane sites at the high-amine end of the gradient to one dominated by acidic silanol sites at the low-amine end. The sub-diffraction-limited spatial resolution afforded by superlocalization of the single molecules reveals spatial correlations in the acid/base properties of the gradient over ~ 200 nm distances. Furthermore, these studies provide data relevant to the use of aminosilane-modified silica in bifunctional, cooperative chemical catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gradient Limitations in Room Temperature and Superconducting Acceleration Structures

Accelerating gradient is a key parameter of the accelerating structure in large linac facilities, like future Linear Collider. In room temperature accelerating structures the gradient is limited mostly by breakdown phenomena, caused by high surface electric fields or pulse surface heating. High power processing is a necessary procedure to clean surface and improve the gradient. In the best tested X-band structures the achieved gradient is exceed 100 MV/m in of {approx}200 ns pulses for breakdown rate of {approx}10{sup -7}. Gradient limit depends on number of factors and no one theory which can explain all sets of experimental results and predict gradient in new accelerating structure. In paper we briefly overview the recent experimental results of breakdown studies, progress in understanding of gradient limitations and scaling laws. Although superconducting rf technology has been adopted throughout the world for ILC, it has frequently been difficult to reach the predicted performance in these structures due to a number of factors: multipactoring, field emission, Q-slope, thermal breakdown. In paper we are discussing all these phenomena and the ways to increase accelerating gradient in SC cavity, which are a part of worldwide R and D program.

43 PARTICLE ACCELERATORS↗

Ground and excited state gradients with end-to-end differentiable semiempirical quantum chemistry

Accurate and efficient gradients of molecular energy with respect to nuclear degrees of freedom are essential for geometry optimization and molecular dynamics, including simulations that go beyond the Born–Oppenheimer regime. A common approach involves deriving analytical formulas for new electronic structure methods, which is often conceptually difficult and requires tedious coding. Here, we implement analytical, semi-numerical, and automatic differentiation (AD)-based gradient pathways for semiempirical Hamiltonian models in the PYSEQM software package, leveraging both graphics processing unit (GPU) and central processing unit (CPU) architectures. We further extend these capabilities to excited states calculated using the configuration interaction singles and time-dependent Hartree–Fock ansätze. We benchmark wall time, peak memory usage, and accuracy across three molecular families of varying chemical complexity, including systems of up to a thousand atoms. For ground-state simulations, analytical and AD gradients achieve near-identical GPU runtimes, while semi-numerical gradients are slower on GPU but remain competitive on CPU. For excited states, both analytical and custom AD approaches using implicit differentiation show similar performance and low memory requirements, whereas gradients with full AD are memory-limited. AD gradients match analytical ones in accuracy across all tested systems, aided by a quaternion-based diatomic frame rotation for two-center quantities that ensures smooth energy surfaces. Overall, automatic differentiation emerges as a practical alternative to analytical gradients in semiempirical quantum chemistry, offering high accuracy while allowing seamless integration in AI-driven workflows and popular packages, such as PyTorch and JAX. Our results provide actionable guidance for selecting optimal gradient strategies in large-scale ground- and excited-state molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗