Search NASA⌕ Search

SEARCH · Search NASA

Results for “graphite and composite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Intercalated graphite fiber composites as EMI shields in aerospace structures

The requirements for electromagnetic interference (EMI) shielding in aerospace structures are complicated over that of ground structures by their weight limitations. As a result, the best EMI shielding materials must blend low density, high strength, and high elastic modulus with high shielding ability. In addition, fabrication considerations including penetrations and joints play a major role. The EMI shielding properties are calculated for shields formed from pristine and intercalated graphite fiber/epoxy composites and compared to preliminary experimental results and to shields made from aluminum. Calculations indicate that EMI shields could be fabricated from intercalated graphite composites which would have less than 12 percent of the mass of conventional aluminum shields, based on mechanical properties and shielding properties alone.

Gaier, James R.↗

Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Propellant tanks↗

Scaling effects in the static large deflection response of graphite-epoxy composite beams

Scaling effects in the large deflection response of graphite-epoxy composite beams was investigated. Eight different scale model beams ranging from 1/6 to full-scale were subjected to an eccentric axial compressive load to promote large bending deformations and failures. Beams having laminate stacking sequences including unidirectional, angle ply, cross ply, and quasi-isotropic were tested to examine a wide variety of composite response and failure modes. The model beams were loaded under scaled test conditions until catastrophic failure. Data acquired included load, end displacement, and strain measurements, and qualitative failure measurements. The experimental data is compared to a large rotation beam analysis and a finite element model analysis. Results from the tests indicate that the beam response becomes nonlinear. Failure modes are consistent between scale models within a laminate family, however, a significant scale effect is observed in strength of the scaled beams.

Jackson, Karen E.↗

Application of In Situ Fiberization for fabrication of improved strain isolation pads and graphite epoxy composites

The feasibility of applying the in situ fiberization process to the fabrication of strain isolation pads (SIP) for the Space Shuttle and to the fabrication of graphite-epoxy composites was evaluated. The ISF process involves the formation of interconnected polymer fiber networks by agitation of dilute polymer solutions under controlled conditions. High temperature polymers suitable for SIP use were fiberized and a successful fiberization of polychloro trifluoroethylene, a relatively high melting polymer, was achieved. Attempts to fiberize polymers with greater thermal stability were unsuccessful, apparently due to characteristics caused by the presence of aromaticity in the backbone of such materials. Graphite-epoxy composites were fabricated by interconnecting two dimensional arrays of graphite fiber with polypropylene IS fibers with subsequent epoxy resin impregnation. Mechanical property tests were performed on laminated panels of this material to evaluate intralaminar and interlaminar shear strength, and thus fracture toughness. Test results were generally unpromising.

Rosser, R. W.↗

The effects of microcracking on the thermal expansion of graphite-epoxy composites

A study of the effects of thermal environment and microcracking in graphite epoxy composites was made. Research indicates that microcracking does affect the thermal expansion of composite laminates. The amount of reduction in thermal expansion was a function of the crack density. A maximum reduction of approximately 25% occurred in a quasi-isotropic specimen with a crack density of 2.05 mm 1 in the 90 deg plies. Laminate analysis with appropriate reductions in E sub 2 and Alpha sub 2 of the damaged plies appears to be capable of modeling the observed

Bowles, D. E.↗

Effects of matrix toughness on fatigue response of graphite fiber composite laminates

The effect of the matrix toughness on the fatigue response of graphite-fiber-composite laminates was investigated by comparing the fatigue-response results, obtained using the test method of Bakis et al. (1989), for two graphite-epoxy specimens subjected to constant-amplitude fully-reversed loading, namely, (0/ +45/90/ -45)s4 AS4/PEEK samples with drilled center holes and T300-5208 samples. It was found that, although similar matrix damage modes were observed in the two materials, several significant differences occurred in the S-N data and in stiffness data taken over the lives of the two materials, especially at high cyclic stresses.

Simonds, Robert A.↗

Toughening of graphite-epoxy composites by interlaminar perforated Mylar films

Fracture and notch strength tests of graphite-epoxy composites showed that unidirectional lay-ups generally exhibit longitudinal cracking before failure, whereas multidirectional lay-ups fail transversely with little longitudinal cracking. A simple qualitative analysis suggested that the higher matrix shear stresses in unidirectional materials cause the longitudinal cracking, and that this cracking was responsible for the high toughness of unidirectional composites. In a series of comparative tests, the interlaminar strength of multi-directional composites was reduced by placing perforated Mylar films between laminae; tests on notched and slotted specimens showed that the interlaminar films promoted delamination and longitudinal cracking near the notches and that, as a result, toughness, notch strength, and impact strength were substantially increased.

Elber, W.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites are discussed. In particular, the types of weaves and the resin contents were chosen for comparison. The types of weaves selected are plain weave, satin weave, and tridirectional weave. The composites made of the fabrics are compared to composites made from unidirectional tapes under static and fatigue loading. During static loading, acoustic emission events were monitored. Also, examinations of fracture surfaces and polished sections both away from the fracture surface, and of virgin specimens under an electron microscope are discussed.

Hanagud, S.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites have been discussed in this report. In particular the types of weaves and the resin contents have been chosen for comparison. The types of weaves selected are plain weaves, satin weave and tri-directional weave. The composites made of these fabrics have been compared to composites made from unidirectional tapes under static and fatigue loading. During static loading acoustic emission events have been monitored. Also, examinations of fracture surface and polished sections of specimens away from the fracture surface under an electron microscope have been discussed.

Hanagud, S.↗

Scale effects on the transverse tensile strength of graphite epoxy composites

The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.

Obrien, T. Kevin↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.

Williams, J. H., Jr.↗

Modeling and Characterization of a Graphite Nanoplatelet/Epoxy Composite

A micromechanical modeling procedure is developed to predict the viscoelastic properties of a graphite nanoplatelet/epoxy composite as a function of volume fraction and nanoplatelet diameter. The predicted storage and loss moduli from the model are compared to measured values from the same material using Dynamical Mechanical Analysis, nanoindentation, and tensile tests. In most cases, the model and experiments indicate that for increasing volume fractions of nanoplatelets, both the storage and loss moduli increase. Also, in most cases, the model and experiments indicate that as the nanoplatelet diameter is increased, the storage and loss moduli decrease and increase, respectively.

Odegard, Gregory M.↗

Measuring Ultrasonic Acoustic Velocity in a Thin Sheet of Graphite Epoxy Composite

A method for measuring the acoustic velocity in a thin sheet of a graphite epoxy composite (GEC) material was investigated. This method uses two identical acoustic-emission (AE) sensors, one to transmit and one to receive. The delay time as a function of distance between sensors determines a bulk velocity. A lightweight fixture (balsa wood in the current implementation) provides a consistent method of positioning the sensors, thus providing multiple measurements of the time delay between sensors at different known distances. A linear fit to separation, x, versus delay time, t, will yield an estimate of the velocity from the slope of the line.

Source record↗

Flammabilities Of Graphite-Reinforced Composites

Report describes tests and comparisons of flammabilities, thermal properties, and selected mechanical properties of composite materials made of epoxy and other matrices reinforced by graphite fibers. Composites also compared with baseline epoxy/fiberglass composite. Considers such properties as limiting oxygen index, smoke evolution, products of thermal degradation, total heat release, heat-release rate, loss of mass, spread of flames, resistance to ignition, and thermal stability.

Kourtides, Demetrius A.↗

Effect of lightning strike on bromine intercalated graphite fiber/epoxy composites

Laminar composites were fabricated from pristine and bromine intercalated pitch based graphite fibers. It was found that laminar composites could be fabricated using either pristine or intercalated graphite fibers using standard fabrication techniques. The intercalated graphite fiber composites had electrical properties which were markedly improved over both the corresponding pitch based and polyacrylonitrile (PAN) based composites. Despite composites resistivities more than an order of magnitude lower for pitch based fiber composites, the lightning strike resistance was poorer than that of the Pan based fiber composites. This leads to the conclusion that the mechanical properties of the pitch fibers are more important than electrical or thermal properties in determining the lightning strike resistance. Based on indicated lightning strike tolerance for high elongation to failure materials, the use of vapor grown, rather than pitch based graphite fibers appears promising.

Gaier, James R.↗

Ultrasonic evaluation of the strength of unidirectional graphite-polyimide composites

An acoustic-ultrasonic method is described that was successful in ranking unidirectional graphite-polyimide composite specimens according to variations in interlaminar shear strength. Using this method, a quantity termed the stress wave factor was determined. It was found that this factor increases directly with interlaminar shear strength. The key variables in this investigation were composite density, fiber weight fraction, and void content. The stress wave factor and other ultrasonic factors that were studied were found to provide a powerful means for nondestructive evaluation of mechanical strength properties.

Vary, A.↗