At least 163 records · Page 9

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Secure Time Synchronization in Power Grids and Network HIL Synchrophasor Testing

Reliable and secure time synchronization underpins the monitoring and control functions of modern power grids. As GPS-based timing infrastructures grow more susceptible to spoofing and jamming, their vulnerabilities pose escalating risks to grid stability. This work investigates a secure, resilient timing framework that can serve as an alternative or redundant source for power grids, with a particular focus on synchrophasorbased applications. A candidate timing system architecture is evaluated to guarantee trustworthy time dissemination, even in degraded conditions. A network hardware-in-the-loop testing of two synchrophasors validates the concepts, demonstrating enhanced timing integrity, improved detection of timing anomalies, and sustained observability during adverse timing events.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

MARVEL Instrumentation, Control, and Software Considerations

This paper details the various I&C considerations and design decisions made throughout the MARVEL (Micro-reactor Applications Research Validation and Evaluation) project, including sensor and actuator selection, safety-related functionality, digital control hardware and software, and testing methodologies. Key challenges such as managing radiation, temperature, and space constraints are discussed, along with the trade-offs between using standard equipment and custom solutions. The successful integration of off-the-shelf components, the emphasis on minimizing safety-related instrumentation, and the lessons learned from prototyping and testing are highlighted. The authors aim to provide insights that can benefit future micro-reactor designs and emphasize the importance of real-world testing in advancing reactor technology.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

From Atoms to Wheels: The Role of Multi-Scale Modeling in the Future of Transportation Electrification

Traditionally, prototype hardware is built for validation testing to ensure battery systems design changes meet vehicle-level requirements, which is expensive both in cost and time. Virtual engineering (VE) of battery systems for electric vehicle (EV) propulsion offers a reduced-cost alternative to the traditional development process and uses multi-scale modeling to virtually probe the impact of design changes in a particular part on the overall performance of the system. This allows for rapid iteration over multiple design spaces, without committing to build hardware. This perspective article discusses current trends in VE for EV applications and proposes improvements to accelerate EV adoption.

Garrick, Taylor R. (ORCID:0000000322518129)↗

Digital Image Correlation as an Experimental Modal Analysis Capability

Digital image correlation (DIC) is an established test technique in several fields including quasi-static displacement measurements. Recently there has been growing interest in using DIC to measure structural dynamic response and even extract modal parameters from that information. Although high-speed cameras have become more ubiquitous, there are no commercial end-to-end packages for modal analysis based on image data, particularly when combined with traditional data acquisition systems. As such, the practitioner is left to develop several key data processing capabilities, hardware interface equipment, and testing practices themselves. This work highlights several practical aspects that have been encountered while establishing DIC as a viable modal testing capability in a laboratory environment.

47 OTHER INSTRUMENTATION↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Citation network datasets for benchmarking spiking graph neural networks on experimental neuromorphic hardware

Spiking neural networks (SNNs) running on neuromorphic computers offer an energy-efficient alternative for AI tasks. Recently, spiking graph neural networks (S-GNNs) have been shown to produce encouraging results on benchmark citation network datasets such as Cora, CiteSeer, and PubMed for node classification tasks. These S-GNNs were run on SNN simulators only because they contain up to tens of thousands of neurons and up to millions of synapses, translating poorly to neuromorphic hardware. Therefore, in this paper, we create a suite of benchmark datasets from the CiteSeer dataset that can be accommodated on current neuromorphic hardware platforms. Our contribution consists of a collection of three datasets. First, we have an induced subgraph of CiteSeer, which we call MiniSeer, containing 2110 papers, 3604 binary features, and 6 topics. Second, MicroSeer is a very small dataset consisting of 84 papers, 1227 features, and 6 topics. Lastly, BiteSeer is a collection of 15 binary classification datasets. We present creation of these datasets along with accuracies, running times, and spike counts when simulated. We believe that our results in this paper will be used by the neuromorphic community to benchmark, test, and develop neuromorphic hardware and simulators.

Zhu, Kevin [George Mason University, Virginia]↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Cyber-Attack Detection for Photovoltaic Farms Based on Power-Electronics-Enabled Harmonic State Space Modeling

Here in this paper, a physics-data-based detection method is proposed to detect a variety of cyber-attacks in Photovoltaic (PV) farms using the power electronics-enabled harmonic state space (HSS) models, which, to our knowledge, is original. At the device level, HSS-based detection is developed to monitor harmonic vectors of individual PV converter with minimum sensor measurements, thus improving accuracy and robustness compared to Kalman Filter-based detection. At the system level that involves multiple PV converters, a clustering approach is developed to investigate attack propagation and accurately locate attack sources within a PV farm. The proposed approach is one of the first attempts to address PV security through interaction between the device and system, maximizing the accuracy and robustness at different levels. To verify the feasibility, a comprehensive attacks model is built, including single attack, coordinated attacks, and replay attacks. Besides, the impacts of irradiance changes are taken into consideration in the test scenarios. With the real-time data acquisition and hardware-in-the-loop testbed, comprehensive test results are provided to verify the feasibility of the proposed detection methodology.

42 ENGINEERING↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

High strain rate nanoindentation testing: Recent advancements, challenges and opportunities

Recent advancements in electronics have renewed the interest in high strain rate nanoindentation testing, resulting in the development of new high strain rate nanoindentation test equipment and test methodologies. Here, in this work, the current state-of-the-art in high strain rate nanoindentation testing is critically reviewed, with focus on three key aspects - the testing equipment's dynamic mechanical and electronic response, test methodology, and post-processing of raw data to obtain hardness and strain rate. The challenges in instrument hardware design and post-test data analysis are discussed, along with optimal strain rate window for accurate high strain rate measurements. Specific focus will be on instrumented high strain rate testing using self-similar indenters at strain rates in excess of 100 s -1 , wherein load and depth of penetration into the sample are both measured or applied.

36 MATERIALS SCIENCE↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Scattering phase shift in quantum mechanics on quantum computers

Here, we investigate the feasibility of extracting infinite volume scattering phase shift on quantum computers in a simple one-dimensional quantum mechanical model, using the formalism established in the work by Guo and Gasparian [Phys. Rev. D 108, 074504 (2023)] that relates the integrated correlation functions for a trapped system to the infinite volume scattering phase shifts through a weighted integral. The system is first discretized in a finite box with periodic boundary conditions, and the formalism in real time is verified by employing a contact interaction potential with exact solutions. Quantum circuits are then designed and constructed to implement the formalism on current quantum computing architectures. To overcome the fast oscillatory behavior of the integrated correlation functions in real-time simulation, different methods of postdata analysis are proposed and discussed. Test results on IBM hardware show that good agreement can be achieved with two qubits, but complete failure ensues with three qubits due to two-qubit gate operation errors and thermal relaxation errors.

Guo, Peng [Dakota State Univ., Madison, SD (United↗

Evaluation of phase shifts for nonrelativistic elastic scattering using quantum computers

Simulations of scattering processes are essential in understanding the physics of our universe. Computing relevant scattering quantities from ab initio methods is extremely difficult on classical devices because of the substantial computational resources needed. Here, this work reports the development of an algorithm that makes it possible to obtain phase shifts for generic nonrelativistic elastic scattering processes on a quantum computer. This algorithm is based on extracting phase shifts from the direct implementation of the real-time evolution. The algorithm is improved by a variational procedure making it more accurate and resistant to the quantum noise. The reliability of the algorithm is first demonstrated by means of classical numerical simulations for different potentials and later tested on existing quantum hardware, specifically on IBM quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Network Reconfiguration and Scheduling With Hardware-in-the-Loop Validation for Improved Microgrid Resilience

With the increased occurrence of various major extreme weather events, power outages and prompt power system restorations have recently drawn more attention to the resilience and recovery of power systems. From the perspective of a more resilient power delivery at the distribution grid, system restoration using network topology reconfiguration together with optimal scheduling of distributed energy resources are adopted in this paper. The proposed optimization model aims at minimizing the total load shedding cost and other operational costs, in which linearized topological constraints borrowed from graph theory and linearized DistFlow models are respectively used to maintain the radial network topology and power flow balance after system contingencies. To demonstrate the applicability of the proposed strategy, a real-world case study of a networked three-microgrid system in Adjuntas, Puerto Rico, is used with the consideration of different independent/interconnected microgrid scenarios, contingencies, and fairness settings. Furthermore, hardware-in-the-loop testing is conducted for the same three-microgrid network, where the closely matched results with the simulated ones have validated the effectiveness of the proposed restoration strategy, which is now ready to move one step forward towards field deployment. Finally, to test the proposed restoration strategy in a larger networked system, the modified IEEE-33 bus test distribution system is considered, and the results show a more resilient power delivery for critical loads under three and four line outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗