Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Exploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City

Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city-scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single-layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super-cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super-cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super-cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super-cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city-scale is urgent for sustainable urban planning.

54 ENVIRONMENTAL SCIENCES↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Projection Analysis for ATR Irradiation of the AFC-FAST Experiment

Analyses of the Advanced Fuels Campaign Fission Accelerated Steady-state Test (AFC-FAST) in the Advanced Test Reactor are presented. A detailed methodology was employed to better account for uncertainties in the planned power and duration of sequential reactor loading cycles. By performing coupled depletion analyses at multiple power levels and durations, the differences in experiment heating outputs can be found. The effects of these uncertainties upon multiple experiment configurations were assessed in an effort to streamline the process of planning for and documenting future irradiations. In conclusion, the data generated from this work have been used to help inform assumptions on subsequent projections to perform only a nominal case depletion.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distributed Energy Resources Disaster Matrix

This issue brief explores how different distributed energy resources (DERs) are impacted by various types of natural disasters to assist stakeholders in evaluating the technology options best able to meet their resilience priorities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theory-guided Design of Refractory MPEAs for High-Temperature, Harsh-Service Conditions

Focusing on novel materials for harsh-service environments (oxidation, corrosion, and load), durability, higher operational temperature, and direct impact on power-generation technology, the goal was, using a quantitative theory-guided design approach integrated with high-throughput synthesis and characterization for validation, to accelerate by 50% the development of high temperature, refractory-based multi-principal element alloys (MPEAs) materials platforms (with co-designed oxidation-resistant, self-healing coatings) that demonstrate phase-stable operation with desired properties at 10-20% higher temperatures in oxidizing environments over state-ofthe- art systems (like Ni-stainless steels, i.e., Haynes 282 – used in critical gas turbine applications, and refractory TZM, i.e., molybdenum-rich Mo99.4-Ti0.5-Zr0.08-C0.02 in wt%). Notably, refractory MPEAs may achieve higher operational temperatures with superior creep strength and offer 50-100% larger thermal conductivity (140-170 W/m-K) than Ni-based systems, potentially eliminating active cooling, reducing system weight, complexity, and cost. Achieving this goal addresses DOE material challenges in energy generation and efficiency (higher-temperature operation), reduced lifecycle energy (waste-heat recovery), and accelerating materials development in support of AMO’s Strategic Plan and QTR goals. DOE’s Advanced Manufacturing Office (AMO) goal of reducing industrial energy intensity and GHG emissions is addressed by development of coated refractory MPEAs exhibiting 20%+ higher operational temperature (direct increase of Carnot efficiency), higher melting temperatures (better phase stability), superior creep strength (better lifetime with creep rate lower by factor of 10), larger (50-100%) thermal conductivity (improved cooling without active cooling), reduced complexity (single-phase alloys), self-healing coating (reliable oxidation-resistance) and cost.

36 MATERIALS SCIENCE↗

Analysis of Frost Formation and Novel Defrost Techniques for Commercial Refrigeration Applications

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test a heat exchanger defrosting approach using radiant energy, including ultraviolet-C, -B, and -A. A preliminary test conducted at Oak Ridge National Laboratory demonstrated the concept of ultraviolet-based defrosting, which melts frost on the fin surface of a heat exchanger without increasing its overall temperature, thereby offering a new defrosting method that does not interrupt heat exchanger operation. Building on this key finding, this CRADA outlines a plan for upgrading the test equipment and for further testing to bridge the gap between the concept and its feasibility for industrial applications. This report also provides a brief review of existing defrosting technologies, the current state of the experimental system, and future parametric experiment plans.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Activation of Thermal Insulation and Contamination Prevention

The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of insulating materials in the Molten Chloride Reactor Experiment and to foster safer work environments through informed decision-making and strategic planning. It was written to resolve a gating comment from the core heating system preliminary design review. The largest dose expected from the considered insulation materials is about 0.1 mrem per year from Pyrogel. Although Cerablanket stood out among the insulation materials for encouraging ALARA practices, it has a higher thermal conductivity. At low power levels, focusing on reducing the generation of dust from ERD activities may be more effective for reducing the potential spread of contamination than changing the insulating material type. However, regardless of the material chosen, PPE and safety conscious procedural practices can help reduce the production and spread of activated dust––thus minimizing the radiological hazard to workers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Impacts of the Inflation Reduction Act on Consumer Energy Expenditures

The Inflation Reduction Act introduced or expanded a suite of federal tax credits for clean electricity generation and customer adoption of electric (and other highly efficient) end-use equipment. These incentives are expected to drive changes in both the electricity generation mix and demand for electricity (especially for space heating and light-duty vehicles), which are highly interconnected. In this session, Caitlin Murphy, Group Manager and Senior Analyst in NREL's Strategic Energy Analysis Center, will present findings from her team's recent state-level analysis on the combined effects of various IRA incentives on customer expenditures for electricity, natural gas, and gasoline. She will present and explain the regional variations observed in their analysis, based on interactions between end-use equipment cost and performance and projections for future energy prices.

air source heat pump↗

Advanced Modular Sub-Atmospheric Hybrid Heat Engine (Phase 1 Final Report)

The Phase 1 Final Report describes the results of the work completed during the “Advanced Modular Sub-Atmospheric Hybrid Heat Engine” project. The objectives of Phase 1 work were to develop a conceptual design of the turbine-based modular hybrid heat engine (MHHE), including thermodynamic cycle analysis, define the nominal engine component boundary conditions, identify technology gaps, and develop a detailed test plan to address these gaps through bench scale testing in a potential subsequent Phase 2 project. To achieve the project objective, the following activities were performed in Phase 1 work: (1) Market analysis and primary fuel selection, (2) Conceptual design and integrated layout development, (3) Design support and key components characterization, (4) Planning to move technology to pre-commercial demonstration.

42 ENGINEERING↗

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Consumer Guide to Residential Renewable Energy

Learn how installing residential renewable energy systems, such as geothermal heat pumps and wind or solar energy systems, can save energy, lower utility bills, and earn homeowners money. This fact sheet from Energy Saver includes information on how to start planning to install renewable energy systems at home.

residential renewable energy, geothermal heat pump↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Boundary Layer Height Variation over the Savannah River Site during a Heat Wave

With the number of heat waves expect to increase in both in their severity and frequency in the coming years, an insight into their impact on planetary boundary layer (PBL) heights is essential for one development of future emergency and safety plans. Using High-Resolution Rapid Refresh (HRRR) atmospheric model output, an analysis is done on the effects a heat wave has on PBL heights and temperature inversions across the Savannah River Site (SRS). This study showed that due to its adjacency to anthropogenic land use, SRS experiences a non-negligible gradient in its PBL height, with higher heights to the northwest. The singular location PBL heigh measurement and forecasts for SRS do not account for this gradient, which has potential implications on pollutant and smoke dispersion onsite. During a heat wave this gradient is present but PBL heights are less impacted than surrounding developed areas, possibly attributable to the woody wetlands that surround the Savannah River's banks. Additionally, the heat wave appears to strongly enhance the nocturnal temperature inversions that the site and surrounding areas experience. This is possibly due to increased stability from higher pressure conditions, which are often associated with heat waves. This influence on nocturnal inversions, however, is limited to their intensity, leaving their timing relatively unaltered. The impact a heat wave has on PBL heights and temperature inversions across SRS is seen to be more dependent on adjacent land use and features rather than the unique land use types onsite.

54 ENVIRONMENTAL SCIENCES↗

Qualification and Commissioning of Helium Flow Loop Experiment for Blanket Design Measurements

Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent and planned hydrodynamic instability experiments on indirect-drive implosions on the National Ignition Facility

At National Ignition Facility (NIF), yield amplification due to alpha particle heating approached ~3 in the highest performing inertial confinement fusion (ICF) implosions, while yield amplification of ~15-30 is needed for ignition. Hydrodynamic instabilities are a major factor in degradation of implosions while understanding and mitigation of the instabilities are critical to achieving ignition. This article describes recent and planned hydrodynamic instability experiments with several focused platforms that have been developed to directly measure these instabilities in all phases of ICF implosions. Measurements of ripple-shock generation at OMEGA laser have indicated initial seeds for the instabilities in three ablators - plastic (CH), beryllium, and high-density carbon (HDC). Hydrodynamic Growth Radiography (HGR) platform was used to measure instability growth at the ablation front in the acceleration phase of implosions. This platform used pre-imposed 2-D perturbations for growth factor measurements at different perturbation wavelengths and was also used to measure growth of “native roughness” modulations, fill tubes, and capsule support membranes or “tents”. Also, in the acceleration phase several new experimental platforms have been or are being developed to measure instability growth at the ablator-ice interface. In the deceleration phase of implosions, “self-emission” and “self-backlighting” platforms were developed to measure perturbations near peak compression. This article reviews recent progress and results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗