Search NASA⌕ Search

SEARCH · Search NASA

Results for “heavy ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The non-Z-squared response of the heavy nuclei cosmic ray detector on HEAO-3

A combination of ion chambers and Cerenkov radiators similar to the Heavy Nuclei Experiment flown on HEAO-3 was calibrated at the Bevalac heavy-ion accelerator using beams of Mn-25 nuclei at kinetic energies up to about 1700 MeV/nucleon and Au-79 nuclei up to about 1000 MeV/nucleon. The data show only a small deviation (about 2-3 charge units at Au) from the Z-squared scaling used previously (Binns et al., 1981, 1982, 1983) to analyze the HNE data. Although at lower energy, the calibration indicates that the published relative abundances of the Sn-50/Ba-56 group and the published upper-limit actinide abundances are not likely to be significantly affected by non-Z-squared effects.

Garrard, T. L.↗

Bragg Curve, Biological Bragg Curve and Biological Issues in Space Radiation Protection with Shielding

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-LET gamma or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal since biological effects are influenced by the track structure of both primary and secondary particles. Therefore, the biological Bragg curve is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. To achieve a Bragg curve distribution, we exposed cells to energetic heavy ions with the beam geometry parallel to a monolayer of fibroblasts. Qualitative analyses of gamma-H2AX fluorescence, a known marker of DSBs, indicated increased clustering of DNA damage before the Bragg peak, enhanced homogenous distribution at the peak, and provided visual evidence of high linear energy transfer (LET) particle traversal of cells beyond the Bragg peak. A quantitative biological response curve generated for micronuclei (MN) induction across the Bragg curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono-to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results, along with other biological concerns, show that space radiation protection with shielding can be a complicated issue.

Honglu, Wu↗

Single-Event Effect Testing of the Linear Technology LTC6103HMS8#PBF Current Sense Amplifier

The LTC6103HMS8#PBF (henceforth abbreviated as LTC6103) current sense amplifier from Linear Technology was tested for both destructive and non-destructive single-event effects (SEE) using the heavy-ion cyclotron accelerator beam at Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Effects (BASE) facility. During testing, the input voltages and output currents were monitored to detect single event latch-up (SEL) and single-event transients (SETs).

single-event effects (SEE)↗

Simulations and Observations of Heating of Auroral Ion Beams

In the auroral zone, quasi-static parallel electric fields produce beams of ionospheric ions (e.g., H(+), He(+) and 0(+)), which flow outward into the magnetosphere, providing a significant source of ions for the ring current and plasma sheet. Because the velocities to which these beams are accelerated is dependent on the mass of the ions, differential flows between the various ion species can develop which are unstable to an ion-ion streaming instability. Particle simulations and observations from DE 1 are used to investigate the heating of the ion beams produced by this instability. It is shown that there is net transfer of energy from the light ions to the heavy ions, with the heavy ions reaching maximum velocities near the beam velocity of the light ions. Bulk heating of the heavy ions occurs when their relative density is low while high-energy tails are produced when their relative density is high. The heating is primarily parallel to the magnetic field if the difference in the heavy and light ion beam velocities is subsonic while both perpendicular and parallel heating can occur if it is supersonic. In the latter case, very strong heating of an intermediate ion's species such as He(+) can also occur. Comparison with observations shows features consistent with heating via the ion-ion instability including perpendicular heating in the supersonic regime and parallel heating in the subsonic regime and a change in the heating between these regimes as the ratio of the H(+) beam speed to the local sound speed is observed to decrease. This heating is, however, not always observed in association with enhanced wave emissions. This lack of waves is attributed to reabsorption of the waves as the ions become heated.

Winglee, R. M.↗

Second Report of the Nuclear Data Subcommittee of the Nuclear Science Advisory Committee

The central importance of the nuclear data curated by the US Nuclear Data Program (USNDP) for clean energy generation, national security, nonproliferation, medical applications, and space exploration as well as basic science was described in a prior report issued by the DOE/NSF Nuclear Science Advisory Committee subcommittee on Nuclear Data (NSAC-ND) in September 2022. In this report, we present a set of fourteen (14) recommendations that will enhance and advance DOE-NP's stewardship of nuclear data. The first three recommendations focus on the existing core USNDP capabilities, namely: 1) Support the nuclear structure evaluation workforce to improve the currency, consistency, and accessibility of the Evaluated Nuclear Structure Data File (ENSDF); 2) Enhance nuclear reaction evaluation within the USNDP in support of the Evaluated Nuclear Data File (ENDF) through expansion of the workforce and integration of high-performance computing, automation, and machine learning and; 3) Continue atomic mass evaluation in support AME and NUBASE databases. This is followed by eight (8) recommendations representing new cross-cutting initiatives involving both measurement and evaluation to address outstanding nuclear data needs. These new initiatives require a highly trained, diverse workforce that includes personnel with expertise from both inside and outside the nuclear physics community from which evaluators have traditionally been recruited. As such, many of these initiatives are accomplished via a Topical Nuclear Data Collaborations (TNDC). A TNDC is made up of domestic and international stakeholders, subject matter and nuclear data experts, and nuclear data evaluators and features a workforce development plan to ensure that nuclear data evaluators maintain currency in the relevant applications and are seen as equity partners in the endeavor. These include: 1) Establish a coordinated effort to improve evaluation and modeling in nuclear astrophysics for stellar dynamics, multi-messenger astronomy and nucleosynthesis; 2) Initiate a TNDC to develop and maintain nuclear structure evaluation beyond discrete states, including nuclear level densities, photon strength functions and photonuclear data for improved reaction modeling, and exploring nuclear structure at finite temperature; 3) Create a TNDC to perform correlated fission data evaluation, including cross sections, fragment yields, v(A), v(E n ) for nuclear energy, national security, nonproliferation and basic science; 4) From a panel of subject matter experts to establish and annually update a roster of key decay data to nurture its accelerated dissemination including both measurement and evaluation for targeted high-value nuclides for national security, nonproliferation and medical applications; 5) Comprehensive, consistent neutron-induced structure and reaction data for nuclear energy, national security, nonproliferation and planetary nuclear spectroscopy; 6) Charged-particle stopping powers for detector design, space effects and ion beam therapy; 7) High-energy reactions for space exploration and medical nuclide production, and; 8) The creation of an infrastructure for open data and data preservation for use by the entire nuclear physics community. All told, these initiatives require approximately $6.5M increase in NP support of the USNDP in fiscal year 2023 dollars and would require at least 3-5 years to carry out due to the length of time needed to recruit and train new nuclear data researchers. This relatively modest investment would help ensure that the fruits of the nuclear data research carried out by DOE-NP and its collaborators would be brought to bear to address some of the most important needs of our nation and the world. To ensure effective execution of this plan, we present an overview of recruitment, training, and retention goals for the USNDP, the centerpiece of which is a mutually agreed upon code of conduct. Finally, we identify the facility and instrumentation needed to perform the recommended experimental activities. This includes a short review of target fabrication capabilities, reactors, neutron beam, light- and heavy-stable ion, gamma-ray, high-energy and radioactive ion beam facilities. Lastly, a more complete appendix of experimental facilities previously compiled is included with new input provided for 6 facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interplanetary particle beams

This paper reviews observations of interplanetary particle beams of the kind that frequently accompany a solar flare. It is shown that the most frequently observed beams are beams of electrons which are associated with radio bursts of type III, but occasionally with flares and X-ray bursts. Although the main features of these beams and their associated plasma waves and radio bursts are known, uncertainties remain in terms of the correlation between electron beams and filamentary structures, the relative importance of the quasi-linear and the nonlinear wave emissions as the dominant process, and the mechanism of conversion of some of the Langmuir wave energy into radio emissions. Other particle beams discussed are those composed of protons, neutrons, He ions, or heavy ions. While most of these beams originate from sun flares, the source of some of particle beams may be the earth, Jupiter, or other planets as well as comets.

Dulk, G. A.↗

Current and future uses of accelerators in particle astrophysics

Beams of artificially accelerated heavy ions, protons, antiprotons, electrons, and positrons currently available at (and planned for) numerous facilities around the world are a valuable resource to the Cosmic Ray community. Such beams have been used to test detector concepts, calibrate balloon-borne and space flight experiments and to measure fundamental nuclear physics parameter necessary for the interpretation of Cosmic Ray data. As new experiments are flown the quality and extent of Cosmic Ray measurements will continue to improve. It will be necessary to increase activity at ground based accelerators in order to test/calibrate these new instruments and to maintain (or possibly improve) the ability to interpret these data. In this area, the newly formed Transport Collaboration, supported by NASA, will be providing new nuclear interaction cross section measurements for beams with Z less than or = 58 and supporting new instrument calibrations at the Lawrence Berkeley Laboratory Bevalac accelerator.

Guzik, T. G.↗

Heavy Ion Minibeam Therapy: Side Effects in Normal Brain

The purpose of this work was to investigate whether minibeam therapy with heavy ions might offer improvements of the therapeutic ratio for the treatment of human brain cancers. To assess neurotoxicity, we irradiated normal juvenile rats using 120 MeV lithium-7 ions at an absorbed integral dose of 20 Gy. Beams were configured either as a solid parallel circular beam or as an array of planar parallel minibeams having 300-micron width and 1-mm center-to-center spacing within a circular array. We followed animals for 6 months after treatment and utilized behavioral testing and immunohistochemical studies to investigate the resulting cognitive impairment and chronic pathologic changes. We found both solid-beam therapy and minibeam therapy to result in cognitive impairment compared with sham controls, with no apparent reduction in neurotoxicity using heavy ion minibeams instead of solid beams under the conditions of this study.

60 APPLIED LIFE SCIENCES↗

Partial-Transmission Scintillation Detector for Ions

Only outer portion of ion beam sampled to prevent unnecessary energy losses. Measurement device allows only periphery of beam to pass through scintillation material. Total flux in uniform beam inferred from peripheral flux. Device provides readings without reducing energy of ions in middle of beam. Measurement device developed for ion beams used in studies of how fast heavy ions affect integrated-circuit chips.

Malone, C. J.↗

Linear instabilities in multicomponent plasmas and their consequences for the auroral zone

Ion conics are commonly observed along auroral-zone field lines and involve all major terrestrial ion species, including H, He, and O. It is believed that low-frequency plasma waves, driven unstable by field-aligned currents, transversely heat the ion distributions via wave-particles interactions, creating the ion conics. Considered here are low-frequency oblique electrostatic instabilities found in a mixed plasma that includes an electron beam streaming through a background of electrons, H and O. The addition of O not only modifies the lower hybird frequency, but allows the existence of an ion-ion (Buchsbaum) hybrid mode with a frequency between the H and O gyrofrequencies. Because of its low frequency, the ion-ion hybrid instability can be effective in transversely heating heavy ions. When the electron beam drift speed is greater than 3 times the background electron thermal velocity and the electron gyrofrequency to plasma frequency ratio is less than 10, the lower hybrid instability dominates. However, for ratios greater than 20, which is a condition commonly found in the auroral-zone nightside region, the ion-ion instability has the largest growth rates; in these regions, heavy ion transverse heating can occur. When the ratio is between 10 and 20, the H to O density ratio determines which instability dominates.

Schriver, David↗

Illuminating early-stage dynamics of heavy-ion collisions through photons at RHIC BES energies

Heavy-ion collisions at $\sqrt {^SNN}$~10 GeV probe the QCD phase diagram at large baryon densities. Because the longitudinal Lorentz contraction is small at these collision energies, understanding the dynamics during the early phase of the collision is essential for the subsequent modeling of the system evolution and for constraining the QGP transport properties at finite baryon densities. Direct photons provide undistorted information on early-stage dynamics. We model relativistic heavy-ion collisions at RHIC Beam Energy Scan energies with a hybrid dynamical approach consisting of a 3D-Glauber initial state followed by viscous hydrodynamics and hadronic transport (MUSIC + UrQMD). The implemented thermal photon emission takes into account the enhancement from finite baryon chemical potentials. We show that direct photon spectra and their anisotropic flow coefficients have a strong sensitivity to the early stage of heavy-ion collisions. Thus, they provide constraints on QGP dynamics complementary to those obtained from hadronic observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A state of the art Lambertson septum magnet of the RHIC beam injection system

The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system. This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet.

43 PARTICLE ACCELERATORS↗

Performance of laser ion source LION operated at Brookhaven National Laboratory

LION is a laser ion source that has been in operation at Brookhaven National Laboratory (BNL) to provide heavy ions for NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). It is the first laser ion source to supply stable ion beams for a long-term operation for users at a large accelerator facility in the world. LION is located at the upstream end of the heavy ion accelerator complex at BNL and supplies singly charged ion beams of various ion species. LION has been in operation since 2014 and is planned to be upgraded in 2024. This paper summarizes the operational performance achieved by LION.

43 PARTICLE ACCELERATORS↗

Search for the chiral magnetic effect in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV with the STAR forward event plane detectors

A decisive experimental test of the Chiral Magnetic Effect (CME) is considered one of the major scientific goals at the Relativistic Heavy-Ion Collider (RHIC) towards understanding the nontrivial topological fluctuations of the Quantum Chromodynamics vacuum. In heavy-ion collisions, the CME is expected to result in a charge separation phenomenon across the reaction plane, whose strength could be strongly energy dependent. The previous CME searches have been focused on top RHIC energy collisions. In this Letter, we present a low energy search for the CME in Au+Au collisions at $\sqrt{s_{NN}}$ = 27 GeV. We measure elliptic flow scaled charge-dependent correlators relative to the event planes that are defined at both mid-rapidity |η| < 1.0 and at forward rapidity 2.1 < |η| < 5.1. We compare the results based on the directed flow plane ( $Ψ$ 1 ) at forward rapidity and the elliptic flow plane ( $Ψ$ 2 ) at both central and forward rapidity. The CME scenario is expected to result in a larger correlation relative to $Ψ$ 1 than to $Ψ$ 2 , while a flow driven background scenario would lead to a consistent result for both event planes. In 10-50% centrality, results using three different event planes are found to be consistent within experimental uncertainties, suggesting a flow driven background scenario dominating the measurement. We obtain an upper limit on the deviation from a flow driven background scenario at the 95% confidence level. This work opens up a possible road map towards future CME search with the high statistics data from the RHIC Beam Energy Scan Phase-II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pickup Ion Velocity Distributions at Titan: Effects of Spatial Gradients

The principle source of pickup ions at Titan is its neutral exosphere, extending well above the ionopause into the magnetosphere of Saturn or the solar wind, depending on the moon's orbital position. Thermal and nonthermal processes in the thermosphere generate the distribution of neutral atoms and molecules in the exosphere. The combination of these processes and the range of mass numbers, 1 to over 28, contribute to an exospheric source structure that produces pickup ions with gyroradii that are much larger or smaller than the corresponding scale heights of their neutral sources. The resulting phase space distributions are dependent on the spatial structure of the exosphere as well as that of the magnetic field and background plasma. When the pickup ion gyroradius is less than the source gas scale height, the pickup ion velocity distribution is characterized by a sharp cutoff near the maximum speed, which is twice that of the ambient plasma times the sine of the angle between the magnetic field and the flow velocity. This was the case for pickup H(sup +) ions identified during the Voyager 1 flyby. In contrast, as the gyroradius becomes much larger than the scale height, the peak of the velocity distribution in the source region recedes from the maximum speed. Iri addition, the amplitude of the distribution near the maximum speed decreases. These more beam like distributions of heavy ions were not observed from Voyager 1 , but should be observable by more sensitive instruments on future spacecraft, including Cassini. The finite gyroradius effects in the pickup ion velocity distributions are studied by including in the analysis the possible range of spatial structures in the neutral exosphere and background plasma.

Hartle, R. E.↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic /approximately 100-keV/ tailward-directed ion beam outside the Jovian plasma boundary

The hot plasma instrument on the Voyager-2 spacecraft measured a nearly monoenergetic (100 keV) ion beam several hours after crossing the Jovian plasma boundary on the nightside of the planet. The beam, deduced to consist primarily of heavy ions, persisted for about four hours and originated from the general direction of Jupiter. The energy density of the beam was about several times the energy density of the magnetic field (beta greater than 1). This beam, a product of an as yet not understood Jovian plasma acceleration mechanism, provides a dramatic example of the energetic dynamics of Jupiter's magnetosphere.

Krimigis, S. M.↗

RF deflecting cavity for fast radioactive ion beams

Abstract The Facility for Rare Isotope Beams (FRIB) will be a new scientific user facility that produces rare-isotope beams for experiments from the fragmentation of heavy ions at energies of 100–200 MeV/u. During the projectile fragmentation, the rare isotope of interest is produced along with many contaminants that need to be removed before the beam reaches detectors. At FRIB, this is accomplished with a magnetic projectile fragment separator. However, to achieve higher beam purity, in particular for proton-rich rare isotopes, additional purification is necessary. RadiaBeam in collaboration with Michigan State University (MSU) has designed a 20.125 MHz radiofrequency (RF) fragment separator capable of producing a 4 MV kick with 18 cm aperture in order to remove contaminant isotopes based on their time of flight. In this paper, we will discuss the RF and engineering design considerations of this separator cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗