Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Modelling of a space-based Ronchi ruling experiment for high-precision astrometry

An end-to-end modelling program for an astrometric telescope employing a Ronchi ruling has been developed. The program models the aberrated images formed anywhere in the field-of-view. It then determines apparent centroids by simulating the motion of a Ronchi ruling across the field. Photo-electron statistics are included. A 6-term plate-constant model is used to determine the apparent motion of a target star within a reference frame as the object is re-observed through both ideal and perturbed optics. The modelling code is accurate at the submicroarcsecond level. optics. The modelling code is accurate at the submicroarcsecond level.

Shaklan, S.↗

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

A High-Precision, Fast-Response Airborne CO2 Analyzer for In Situ Sampling From the Surface to the Middle Stratosphere

Two in situ CO2 analyzers have been developed for deployment on the NASA ER-2 aircraft and on stratospheric balloons. The ER-2 instrument has had more than 150 flights during 21 deployments from 1992 to 2000, resulting in a dataset with nearly pole-to-pole coverage that includes data from all seasons in both hemispheres except austral summer. In-flight calibrations show that the typical long-term (i.e. flight-to-flight) precision of the instruments is better than plus or minus 0.1 ppmv. The flight standards are traceable to standards held by the Scripps Institute of Oceanography and the National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory. The balloon instrument has had 8 balloon flights since September 1996, providing the first in situ observations of CO2 above approx. 21 km. In addition, the balloon instrument has been flown onboard a Cessna Citation II aircraft for sampling between the surface and 10 km. In this paper, the instrumentation and calibration procedures for both instruments are described in detail. An intercomparison of the two instruments during the Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) project showed that, on average, the instruments agreed to within 0.05 ppmv.

Daube, B. C., Jr.↗

Fabrication and Metrology of High-Precision Foil Mirror Mounting Elements

During the period of this Cooperative Agreement, MIT (Massachusetts Institute of Technology) developed advanced methods for applying silicon microstructures for the precision assembly of foil x-ray optics in support of the Constellation-X Spectroscopy X-ray Telescope (SXT) development effort at Goddard Space Flight Center (GSFC). MIT developed improved methods for fabricating and characterizing the precision silicon micro-combs. MIT also developed and characterized assembly tools and several types of metrology tools in order to characterize and reduce the errors associated with precision assembly of foil optics. Results of this effort were published and presented to the scientific community and the GSFC SXT team. A bibliography of papers and presentations is offered.

Schattenburg, Mark L.↗

High Precision Wavelength Monitor for Tunable Laser Systems

A solid-state apparatus for tracking the wavelength of a laser emission has a power splitter that divides the laser emission into at least three equal components. Differing phase shifts are detected and processed to track variations of the laser emission.

Mark E Froggatt↗

Dynamics and Origin of Extra-solar Planetary Systems and Microlensing Detection of Extra-solar Planets

We compare a space-based microlensing search for planets, with a ground based microlensing search originally proposed by D. Tytler (Beichman, et al. 1996). Perturbations of microlensing light curves when the lens star has a planetary companion are sought by one wide angle survey telescope and an array of three or four followup narrow angle telescopes distributed in longitude that follow events with high precision, high time resolution photometry. Alternative ground based programs are considered briefly. With the four 2 meter telescopes distributed in longitude in the southern hemisphere in the Tytler proposal, observational constraints on a ground-based search for planets during microlensing events toward the center of the galaxy are severe. Probably less than 100 events could be monitored per year with high precision, high time resolution photometry with only about 42% coverage on the average regardless of how many events were discovered by the survey telescope. Statistics for the occurrence and properties for Jupiter-mass planets would be meaningful but relatively meager four years after the program was started, and meaningful statistics for Earth-mass planets would be non existent. In contrast, the 14,500 events in a proposed 4 year space based program (GEST = Galactic Exoplanet Survey Telescope) would yield very sound statistics on the occurrence, masses and separations of Jupiter-mass planets, and significant constraints on similar properties for Earth-mass planets. The significance of the Jupiter statistics would be to establish the frequency of planetary systems like our own, where terrestrial planets could exist inside the orbits of the giants.

Peale, S. J.↗

ST7-DRS: A Step Towards Drag-free and High-precision Formation Control

The Space Technology 7 Disturbance Reduction System (ST7-DRS) is an in-space technology demonstration within NASA's New Millennium Program. ST7-DRS is designed to validate system-level technologies that are required for future gravity missions (including the planned LISA gravitational-wave observatory) and for future formation-flying interferometer missions (including the planned MAXIM black-hole imager). ST7-DRS is based around a freely-floating test mass contained within a spacecraft structure that will shield this test mass from all external forces (aside from gravity). The spacecraft position will be continuously controlled, such that the spacecraft, itself, will remain centered about this test mass, essentially flying in formation with it. Colloidal micro-thrusters will be used to control the spacecraft s position to within a few nanometers, over time scales of tens to thousands of seconds. In order to detect the residual acceleration noise on the main test mass, a second test mass will be flown alongside the first, within the same physical spacecraft structure. This test mass will serve as a cross-reference for the first, and will also be used as a reference for the spacecraft's attitude control. The spacecraft's attitude will be controlled to an accuracy of a few milli-arc-seconds, also utilizing the colloidal micro-thrusters. ST7-DRS will consist of an instrument package (containing the test masses) and a set of micro-thrusters, which will be attached to the European Space Agency s SMART-2 spacecraft, set to launch in November 2007.

Houghton, M.↗

Methods for semi-automated indexing for high precision information retrieval

OBJECTIVE: To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. DESIGN: Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. PARTICIPANTS: Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. MEASUREMENTS: Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. RESULTS: Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). SUMMARY: Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.

Evaluation Studies↗

High Precision Metrology on the Ultra-Lightweight W 50.8 cm f/1.25 Parabolic SHARPI Primary Mirror using a CGH Null Lens

For potential use on the SHARPI mission, Eastman Kodak has delivered a 50.8cm CA f/1.25 ultra-lightweight UV parabolic mirror with a surface figure error requirement of 6nm RMS. We address the challenges involved in verifying and mapping the surface error of this large lightweight mirror to +/-3nm using a diffractive CGH null lens. Of main concern is removal of large systematic errors resulting from surface deflections of the mirror due to gravity as well as smaller contributions from system misalignment and reference optic errors. We present our efforts to characterize these errors and remove their wavefront error contribution in post-processing as well as minimizing the uncertainty these calculations introduce. Data from Kodak and preliminary measurements from NASA Goddard will be included.

Antonille, Scott↗

Kinematics of a New High Precision Three Degree-of-Freedom Parallel Manipulator

Closed-form direct and inverse kinematics of a new three degree-of-freedom (DOF) parallel manipulator with inextensible limbs and base-mounted actuators are presented. The manipulator has higher resolution and precision than the existing three DOF mechanisms with extensible limbs. Since all of the manipulator actuators are base-mounted; higher payload capacity, smaller actuator sizes, and lower power dissipation can be obtained. The manipulator is suitable for alignment applications where only tip, tilt, and piston motions are significant. The direct kinematics of the manipulator is reduced to solving an eighth-degree polynomial in the square of tangent of half-angle between one of the limbs and the base plane. Hence, there are at most sixteen assembly configurations for the manipulator. In addition, it is shown that the sixteen solutions are eight pairs of reflected configurations with respect to the base plane. Numerical examples for the direct and inverse kinematics of the manipulator are also presented.

Tahmasebi, Farhad↗

Cryogenic System for Interferometry of High-precision Optics at 20 K: Design and Performance

This report describes the facility and experimental methods at the Goddard Space Flight Center Optics Branch for the measurement of the surface figure of cryogenically-cooled spherical mirrors using standard phase-shifting interferometry, with a standard uncertainty below 2nm rms. Two developmental silicon carbide mirrors were tested: both were spheres with radius of curvature of 600 mm, and clear apertures of 150 mm. The mirrors were cooled within a cryostat, and the surface figure error measured through a fused-silica window. The GSFC team developed methods to measure the in-situ SFE at 20 K with a combined standard uncertainty below 2 nm rms and the change in SFE with temperature (the cryochange) with a combined standard uncertainty of 0.25 -- 0.75 nm rms. This paper will present the measurement facility, methods, and uncertainty analysis.

Blake,Peter↗

High Precision Piezoelectric Linear Motors for Operations at Cryogenic Temperatures and Vacuum

The use of an electromechanical device for optically positioning a mirror system during the pre-project phase of the Pluto Fast Flyby mission was evaluated at JPL. The device under consideration was a piezoelectric driven linear motor functionally dependent upon a time varying electric field which induces displacements ranging from submicrons to millimeters with positioning accuracy within nanometers.

piezoelectric linear motor electromechanical optic↗