Search NASA⌕ Search

SEARCH · Search NASA

Results for “hollow cathodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, insert position, emission current, cathode temperature, orifice diameter, and mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes. The results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages are also presented.

Mirtich, M. J.↗

Investigation of hollow cathode performance for 30-cm thrusters

A parametric investigation of 6.35 mm diameter mercury hollow cathodes was carried out in a bell jar. The parameters that were varied were the amount of initial emissive mix, the insert position, the emission current, the cathode temperature, the orifice diameter, and the mercury flow rate. Flow characteristic curves and performance as a function of time were obtained for the various cathodes of interest. Also presented are the results of a 3880 hr life test of a main cathode run at 15 amps emission current with no noticeable changes in keeper and collector voltages.

Mirtich, M. J.↗

Atlas of the spectrum of a platinum/neon hollow-cathode reference lamp in the region 1130-4330 A

The spectrum of a platinum hollow-cathode lamp containing neon carrier gas was recorded photographically and photoelectrically with a 10.7 m normal-incidence vacuum spectrograph. Wavelengths and intensities were determined for about 5600 lines in the region 1130-4330 A. An atlas of the spectrum is given, with the spectral lines marked and their intensities, wavelengths, and classifications listed. Lines of impurity species are also identified. The uncertainty of the photographically measured wavelengths is estimated to be +/- 0.0020 A. The uncertainty of lines measured in the photoelectric scans is 0.01 A for wavelengths shorter than 2030 A and 0.02 A for longer wavelengths. Ritz-type wavelengths are given for many of the classified lines of Pt II with uncertainties varying from +/- 0.0004 to +/- 0.0025 A. The uncertainty of the relative intensities is estimated to be about 20 percent.

Sansonetti, Jean E.↗

Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor

A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.

Soulas, George C.↗

High pressure working mode of hollow cathode arc discharges

The behavior of high pressure cathotrons is discussed. Methods of preheating either the gas or the cathode itself are detailed together with various geometries for the hollow cathode. Three special configurations were tested, and the results are analyzed.

Minoo, H.↗

A 5,000 hour xenon hollow cathode life test

A cathode life test voluntary terminated after 5024 hours of operation at 25 A is reported. The cathode including a 6.35-mm diameter by 57.12-mm long molybdenum tube with a nominal wall thickness of 0.38 mm is described along with a test facility and start-up procedure. It is shown that over the time of the experiment, the cathode-orifice diameter eroded from 1.80 mm to 2.08 mm, which corresponds to a ratio of the emission current to the orifice diameter at the end of the test of 12.0 A/mm. Tungsten deposits on the interior surface of the insert are detected in post-test analyses, and complete depletion of the original impregnate is suggested by X-ray diffraction analyses. A cathode-jet phenomenon in which energetic ions are produced during hollow-cathode operation at emission currents above 20 A is confirmed.

Brophy, John R.↗

Hollow cathode characteristics in high current discharges

Current and potential distributions have been measured in various large hollow cathodes for currents from 0.9 to 7 kA and mass flows from 0.001 to 16 g/sec. For a variety of cavity diameters and shapes, all operated at 7 kA and 4 g/sec, the cathode current attaches over 0.6 cm of the cavity near the open end, where the electric field is less than 10 V/cm. However, for a fixed cathode configuration, the current conduction pattern is sensitive to both the current and the mass flows. For a given current, a range of mass flows is determined for maximum current penetration into the cavity, with the extent of penetration increasing as current decreases. Spectroscopic and photographic studies of AII radiance and electron densities within the cavity indicate a corresponding distribution of highly conducting plasma.

Krishnan, M.↗

A phenomenological model describing orificed, hollow cathode operation

A phenomenological model is presented which describes the emission processes occurring within the orificed, hollow cathode. The model defines a region of ion production inside the cathode and assumes that the cathode emission current can be accounted for by considering the ion and electron currents which cross the boundary of this region. Most of the current (approximately 72%) comes from electrons produced by field-enhanced, thermionic emission from a well-defined emission surface at the downstream end of the insert which circumscribes the ion product region. The electrons produced at the emission surface feed the ionization process in the region of ion production; the rest of the current (approximately 28%) is carried by the ions produced in the process. Moving at the Bohm velocity, these ions leave the production volume; they then complete the current path by being collected at various cathode potential surfaces, including the emission surface. The model establishes the ratio of ion to electron currents at the emission surface on the basis of the energy balance at that surface. Experimental results corroborating the principal assumptions of the model are presented and discussed.

Siegfried, D. E.↗

Hollow cathode startup using a microplasma discharge

Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

Aston, G.↗

An investigation of conducted and radiated emissions from a hollow-cathode plasma contactor

An investigation conducted on the electrical interference induced by the operation of a hollow-cathode plasma contractor in a ground-based facility is described. The types of electrical interference, or noise, which are important to Space Station Freedom designers are classified as either conducted or radiated emissions. The procedures required to perform conducted and radiated emission measurements on a plasma contactor are examined. The experimental data obtained are typically examined in the frequency domain (i.e. amplitudes of the noise fluctuations versus frequency). Results presented indicate the conducted emissions, which are the current fluctuations from the contactor into the space station wiring, are affected by operating parameters such as expellant flow rate and discharge current. The radiated emissions, which are the electromagnetic waves induced and emitted by the contactor, appear to be influenced by the contactor emission current. Other experimental results suggest possible sources which are responsible for the observed noise. For example, the influence of the plasma environment downstream from the contactor on noise emission levels is described. In addition, a brief discussion is given on the correlation between conducted and radiated emissions and the mechanisms through which both are influenced by the plasma downstream of the contactor.

Buchholtz, Brett W.↗

The Effect of a Hall Thruster-Like Magnetic Field on Operation of a 25-A Class Hollow Cathode

The effect of applying a Hall thruster-like magnetic field to a 25-A class hollow cathode is experimentally characterized. A magnetic simulator that approximated the magnetic field of NASA's HERMeS Hall thruster was used to apply magnetic fields of strengths that varied from 0 to 1.25 of the nominal HERMeS value Bnom. Cathode operation was characterized by parameters such as the discharge voltage, voltage and current oscillation magnitudes, and ion energy spectra. It was found that the application of the magnetic field profoundly affected the operation of the cathode. For the nominal xenon flow rate of 14.7 sccm, when increasing the magnetic field from 0 Bnom to 1.25 Bnom, the discharge voltage increased from 20 V to 40 V and the cathode orifice plate temperature increased from 934 ºC to 987 ºC. Oscillations of the discharge voltage, discharge current, and keeper voltage all remained relatively quiescent. However, the ion energy spectra changed profoundly between conditions, with little ion population above 50 V at 0 Bnom, yet a high-energy ion tail extending above 150 V at the 1.25 Bnom case. These high-energy ions appeared without an increase in the oscillation levels, indicating that previous cathode mode definitions may not apply with the Hall thruster-like magnetic field. The implications of these results on existing cathode operational mode definitions, component-level cathode testing, and operation in a Hall thruster are discussed.

Hall, Scott J.↗

Argon hollow cathode

An interest in alternate propellants for ion-bombardment thrusters, together with ground applications of this technology, has prompted consideration of argon. Several variations of conventional hollow cathode designs were tried, but the bulk of the testing used a hollow tube with an internal tungsten emitter and an orifice at one end. The optimum cathode tube diameter was found to be in the range of 1.0-2.5 cm, somewhat larger than those used for cesium and mercury. Optimum orifice diameter depended on operating conditions, and varied from 0.5 to 5 mm. Biasing the internal emitter negative relative to the cathode chamber reduced the external coupling voltage and should therefore improve orifice lifetime. The expected effect of this bias on emitter lifetime was less clear. Lifetime tests were not conducted as part of this investigation, but several designs show promise of long lifetime in specific applications.

Rehn, L. A.↗

Hollow-Cathode Source Generates Plasma

Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

Deininger, W. D.↗

Fundamental principles of hollow-cathode-discharge operations in space and the design of a rocket-borne demonstration

The issue of hollow-cathode operations in space is treated from the point of view of fundamental principles of plasma interactions and their control over currents involving the device, the spaceborne vehicle, and the ambient space plasma. Particular attention is given to collective plasma processes, the effects of the ambient magnetic field, and the high probability of plasma turbulence triggered by hallow cathode operations. The paper presents a rocket payload and experiment scenario designed for accommodation on a Black Brant booster, launched from a midlatitude site to an apogee in excess of 400 km.

Szuszczewicz, Edward P.↗

Process for thermal imaging scanning of a swaged heater for an anode subassembly of a hollow cathode assembly

A process for thermal imaging scanning of a swaged heater of an anode subassembly of a hollow cathode assembly, comprising scanning a swaged heater with a thermal imaging radiometer to measure a temperature distribution of the heater; raising the current in a power supply to increase the temperature of the swaged heater; and measuring the swaged heater temperature using the radiometer, whereupon the temperature distribution along the length of the heater shall be less than plus or minus 5 degrees C.

Patterson, Michael J.↗

Characterization of the NEXT Hollow Cathode Inserts After Long-Duration Testing

Hollow dispenser cathode inserts are a critical element of electric propulsion systems, and should therefore be well understood during long term operation to ensure reliable system performance. This work destructively investigated cathode inserts from the NEXT long-duration test which demonstrated 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The characterization methods used include scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction. Microscopy analysis has been performed on fractured surfaces, emission surfaces, and metallographically polished cross-sections of post-test inserts and unused inserts. Impregnate distribution, etch region thickness, impregnate chemical content, emission surface topography, and emission surface phase identification are the primary factors investigated.

Mackey, Jonathan A.↗